• Title/Summary/Keyword: Suspension insulator

Search Result 83, Processing Time 0.033 seconds

Development of Live-line Insulator Inspection Robot System for both Suspension and Tension Insulator Strings (현수/내장애자련 겸용 활선애자 점검로봇 시스템 개발)

  • Park, Joon-Young;Lee, Jae-Kyung;Oh, Ki-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1239-1244
    • /
    • 2011
  • In our previous paper, we developed an insulator inspection robot system for a suspension insulator string in the 345kV power transmission line. However, this robot cannot be applied to a tension insulator string, because its constituent insulators are different in diameter and height from those of a suspension insulator string. To solve this problem, we developed a new live-line insulator inspection robot system that is applicable to both suspension and tension insulator strings. We confirmed its effectiveness through live-line performance tests.

A study on the safety of the Environment Corrosion of Suspension Insulater of a Catenary Trolley Wire Systems (카테나리 전차선로 현수애자의 환경부식에 따른 안전성 연구)

  • Lee, Jae-Bong;So, Sun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.864-874
    • /
    • 2007
  • Suspension insulator in Catenary Trolley Wire Systems must have two characteristics, electric insulation and mechanical endurance. Because suspension insulator is used in supporting and insulating position between power supply parts and earth conducted supporting parts. The insulator's electric characteristics can be influenced by surface pollution and damage from the environment such as humidity, dust, smoke, salt. etc. And, the insulating parts can be electrically short. These electrically damaged insulator can cause serious accidents that have far-reaching effect. So appropriate management basis of suspension insulator is needed. And we present appropriate cleaning and the changing period of suspension insulator on the basis of actual data.

  • PDF

The aging test method of insulator and development prospect of polymer insulator (배전용애자의 경년시험방법과 폴리머애자의 개발 동향)

  • Song, I.K;Kim, S.J.;Kim, J.Y.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1791-1793
    • /
    • 1996
  • This paper describes Thermal-Mechanical performance and Ultimate Mechanical-Strength test for the purpose of aging analysis of suspension insulator. The temperature difference of insulator surface according to the aging of suspension insulator brought out about $2^{\circ}C$ to $7-8^{\circ}C$ difference comparing with the atmospheric temperature. Quality standard and Mechanical-Strength of used suspension insulator deteriorate more remarkably than that of new suspension insulator. It is required that Thermal-Mechanical performance test standard be revised in the future. And it is described about the development prospect of polymer insulators

  • PDF

A Study on the aging characteristics of Suspension insulators (현수애자의 경년변화 특성에 관한 연구)

  • 송일근;김상준;김주용;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.4
    • /
    • pp.85-92
    • /
    • 1996
  • This paper describes thermal-mechanical performance and ultimate mechanical-strength test for the purpose of aging analysis of suspension insulator. The temperature of insulator surface according to the aging of suspension insulator was rised about 2[$^{\circ}C$] to 7~8[$^{\circ}C$] difference comparing with the atmospheric temperature. The autoclave expansion of portland cement at the specimen that had much puncture insulator(autoclave measuring value : 0.37[%]) was higher than those of a little puncture insulator (autoclave measuring value : 0.1[ %] ). Quality standard and mechanical-strength of used suspension insulator deteriorate more remarkably than those of new suspension insulator. It is required that thermal-mechanical performance test standard be revised in the future.

  • PDF

Analysis of Dielectric Characteristics of 400kN Suspension Insulator Using FEM (FEM을 이용한 400kN 현수애자의 절연특성 해석)

  • Choe, Jae-Gu;Kim, Ik-Su;Mun, In-Uk;Seo, Hyeong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.80-84
    • /
    • 2002
  • This paper presents some of the results of current research on 400kN Suspension Insulator Design. In this paper, authors carried out 2-dimensional field calculation in order to analyse dielectric characteristics of the insulator unit and 3-dimensional field calculation in order to analyse dielectric characteristics of the insulator strings. And the results of puncture tests of insulators were compared with the required field intensity of the insulator As results, it was found that electric field on the insulator unit is severest between two triple junctions, dielectric characteristics of insulator strings are much influenced by the surrounding configuration and the manufactured insulators have good results of puncture tests.

Development of Robot System for Automatic Cleaning and Inspection of Live-line Suspension Insulator Strings and Its Application (활선 현수애자련 자동 청소 및 점검용 로봇시스템의 개발과 적용)

  • Park, Joon-Young;Cho, Byung-Hak;Byun, Seung-Hyun;Lee, Jae-Kyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.66-75
    • /
    • 2007
  • To prevent an insulator failure, an automatic cleaning and inspection robot was developed for suspension insulator strings. The robot autonomously moves along the insulator string using the clamps installed on its two moving frames. Especially, unlike the existing cleaning robots using jets of water, the robot system adopts a dry cleaning method using rotating brushes and a circular motion guide. In addition, a mechanized brush bristles and a voltage-balancing contactor are devised to increase cleaning efficiency and to prevent arc generation under live-line conditions, respectively. We confirmed its effectiveness through experiments.

Characteristics of the Solid-core Station Post Insulators for the Reliability Estimation (변전소용 애자의 신뢰성 평가를 위한 특성 분석)

  • Kim, Chan-Young;Song, Il-Keun;Kim, Ju-Yong;Lee, Byung-Sung;Jung, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.149-151
    • /
    • 2001
  • This paper presents the results of characteristics of the solid-core and suspension insulators for the reliability estimation. The various analytic techniques. such as ICP, XRD, SEM, EDS, were applied for the purpose. The alumina content of solid-core insulator was less than that of suspension insulator The cristobolite was crystallized only in solid-core insulator. The average pore size of solid-core insulator was larger than that of suspension insulator. However, the numbers of pore were fewer in the solid-core insulator.

  • PDF

A Study on Electric Field Analysis for 300 kN Suspension Insulator Design (300 kN 현수애자의 설계를 위한 전계해석에 관한 연구)

  • Kim, I.S.;Choi, J.G.;Moon, I.W.;Jang, W.Y.;Joo, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2047-2050
    • /
    • 1999
  • This paper presents some of the results of current research on 300 kN Suspension Insulator Design. In this paper, authors first used 2-dimensional field calculation to solve the electric field distribution of an insulator unit and insulator strings, and then 3-dimensional field calculation in order to overcome the shortcomings of 2-dimensional field calculation in which an axis-symmetrical coordinate has been used. And, it was found that the environmental configuration of 300 kN Suspension Insulator String gives great roles to the field distribution of the insulators.

  • PDF

Solid Core Suspension Disc Insulators Preventing Puncture Caused by Steep Front Surge Voltage

  • Sangkasaad, Samruay
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.165-170
    • /
    • 2003
  • This paper presents development of solid core suspension disc insulators (cap and cap suspension disc insulator) for replacing cap and pin suspension disc insulators in overhead transmission and distribution lines which expose to lightning discharges. By this means the punctured problem caused by steep front surge voltage created by lightning discharge on the lines can be solved. The solid core suspension insulator was designed and constructed based on the dimensions of conventional suspension disc insulators (cap and pin insulators). The insulators are made of alumina porcelain. The electrical and mechanical characteristics of the solid core suspension insulators were carried out. The puncture test was performed in the air by applying steep front impulse voltage with amplitude about 2.5 per unit of 50% flashover (CFO) of the insulator unit at negative standard lightning impulse $1.2/50\;\mu\textrm{s}$ with steepness up to $9200\;kV/\mu\textrm{s}$. The testing results show that solid core suspension disc insulators are not punctured eventhough the steepness of the steep front impulse voltage was increased up to $9200\;kV/\mu\textrm{s}$.