• 제목/요약/키워드: Suspended particles

검색결과 353건 처리시간 0.021초

잉크젯 프린팅 기술을 이용한 나노 금속잉크의 인쇄회로기판용 미세배선 형성 (Micro Patterning of Nano Metal Ink for Printed Circuit Board Using Inkjet Printing Technology)

  • 박성준;서상훈;정재우
    • 한국정밀공학회지
    • /
    • 제24권5호
    • /
    • pp.89-96
    • /
    • 2007
  • Inkjet printing has become one of the most attractive manufacturing techniques in industry. Especially inkjet printing technology will soon be part of the PCB (Printed Circuit Board) fabrication processes. Traditional printing on PCB includes screen printing and photolithography. These technologies involve high costs, time-consuming procedures and several process steps. However, by inkjet technology manufacturing time and production costs can be reduced, and procedures can be more efficient. PCB manufacturers therefore willingly accept this inkjet technology to the PCB industry, and are quickly shifting from conventional to inkjet printing. To produce the printed circuit board by the inkjet technology, it must be harmonized with conductive nano ink, printing process, system, and inkjet printhead. In this study, micro patterning of conductive line has been investigated using the piezoelectric printhead driven by a bipolar voltage signal is used to dispense 20-40 ${\mu}m$ diameter droplets and silver nano ink which consists of 1 to 50 nm silver particles that are homogeneously suspended in an organic carrier. To fabricate a conductive line used in PCB with high precision, a printed line width was calculated and compared with printing results.

터널폐수 재이용을 위한 통합형 멤브레인 시스템의 적용 (Feasibility of a two step microfiltration and reverse osmosis membrane system for reuse of tunnel wastewater)

  • 이재현;정세욱;김영모
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.779-785
    • /
    • 2013
  • This study investigated the applicability of a two step microfiltration(MF) and reverse osmosis(RO) membrane system for reuse of tunnel wastewater. In this two step process, the MF system first treated only micropollutants in tunnel wastewater such as suspended solids(SS) and heavy metals, achieving less than 0.2 NTU turbidity, less than 1.1 mg/L chemical oxygen demand($COD_{Mn}$) and less than 0.8 mg/L total manganese(Mn). The RO system then removed over 95 % of the remaining pollutnats and particles, resulting in less than 0.02 NTU turbidity, less than 0.5 mg/L chemical oxygen demand($COD_{Mn}$), less than 0.04 mg/L total nitrogen(T-N) and less than 0.01 mg/L total phosphorus(T-P). In particular, addition of an RO system could lead to markedly reduced high salt concentrations in tunnel wastewater, approaching almost zero. Thus, reclaimed water using the combined membrane system could satisfy current South Korean regulations concerning wastewater reuse(turbidity ${\leq}2.0$ NTU; T-N ${\leq}10mg/L$; T-P ${\leq}0.5mg/L$; Salinity ${\leq}250mg{\cdot}Cl/L$).

Micro-LIF measurement of microchannel flow

  • Kim Kyung Chun;Yoon Sang Youl
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.65-74
    • /
    • 2004
  • Measurement of concentration distributions of suspended particles in a micro-channel is out of the most crucial necessities in the area of Lab-on-a-chip to be used for various bio-chemical applications. One most feasible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been successfully achieved so far due to various limitations in the light illumination and fluorescence signal detection. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having five(5) microns thickness by use of a micro focus laser line generator. The laser sheet beam illuminates an exact plane of concentration measurement field to increase the signal to noise ratio and considerably reduce the depth uncertainty. Nile Blue A was used as fluorescent dye for the present LIF measurement. The enhancement of the fluorescent intensity signals was performed by a solvent mixture of water $(95\%)$ and ethanol (EtOH)/methanol (MeOH) $(5\%)$ mixture. To reduce the rms errors resulted from the CCD electronic noise and other sources, an expansion of grid size was attempted from $1\times1\;to\;3\times3\;or\;5\times5$ pixel data windows and the pertinent signal-to-noise level has been noticeably increased accordingly.

  • PDF

반응기촉매 교체작업시 최적 환기조건에 대한 수치해석적 연구 (A numerical Study on Optimum Ventilation Conditions for the Task of Exchange Catalyst)

  • 윤장근;임용순;신미수
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.190-199
    • /
    • 2018
  • Objectives: The purpose of this case study is to assess the current airflow and find the ideal ventilation conditions in tank reactors for minimizing the possibility of exposure respiratory dusts(size of $2.5{\mu}m$, $10{\mu}m$) when workers exchange catalysts in the tank reactors. Methods: A Numerical study was performed to determine ideal ventilation conditions, We considered two sizes of airborne respiratory particles($2.5{\mu}m$, $10{\mu}m$) at 12points from the bottom of tank reactor. We changed input & output ventilation conditions and analyzed the particle motion in the tank reactor. The star-ccm+, computational fluid dynamics tool was used to predict air & particle flow patterns in the tank reactor and a numerical simulation was achieved by applying the realized ${\kappa}-{\varepsilon}$ turbulence model and the Lagrangian particle tracking method. Results: From the results, the increase of recirculation air had a significant impact on removing dusts because they are removed by HEPA filter. To the contrary, Increasing the clean air quantity or changing the input position of clean air is not good for workers because it causes the exit of respiratory dusts through workers' entrance or cause it to remail suspended in the air in the workplace tank.

Composition and Size Variation of Airborne Fungal Spores in the Asian Dust Events (2000 ~ 2001)

  • Yeo, Hwan-Goo;Kim, Jong-Ho
    • 환경생물
    • /
    • 제20권4호
    • /
    • pp.294-299
    • /
    • 2002
  • PM (Particulate Matter) samples contained fungal spores were collected in the ambient air of Seosan, west Korea, in springtime of 2000 and 2001. PM concentrations were $199.8\mu{g}\;m^{-3}$ in the 1st Asian Dust Storm period (March, 23 ~ 24) and $249.4\mu{g}\;m^{-3}$ in the 2nd period (April, 7~9), 2000. Compared with the concentrations in 2000, relatively low PM concentration ($157.3\mu{g}\;m^{-3}$ ) was measured in the Asian Dust Storm period (April, 24 ~ 20) of 2001. Although there were somewhat differences for the total PM concentrations among the three periods, majorities of the PM were composed of coarse particles sized about 5 ~ 6 $\mu{m}$ over the periods of the two years. Diverse molds grown from fungal aerosols were observed in the PM samples and identified at the genus level. All the genera, Fusarium, Aspergillus, Penicillium, Basipetospora, Epicoccum and Monotospora are hyphomycetes in the division Fungi imperfecti (Deuteromycota). Especially, morphologically more diversified mycelia of hyphomycetes were grown on the fine PM sample (1.1 ~ 2.1 $\mu{m}$) than coarse PM samples in the periods of 2000. Furthermore, some molds were grown on even the background PM sample less than 0.43 $\mu{m}$ in the period of 2001. It was thought that some kinds of ultra fine sized fungal spores were transported by the Asian Dust Storm and suspended in the ambient air of study area during the events.

조류와 유기화합물의 동시제거를 위한 흡착 - DAF 복합공정 (Adsorption-DAF Hybrid Process for the Simultaneous Removal of Algae and Organic Compounds)

  • 이재욱;곽동희;최승필;정흥조
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.208-214
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density floc particles such as algal, color-alum and clay-alum flocs produced from low turbidity water. The removal of taste and odor-causing organics (2-mthylisoboneol and geosmin) originating from algae in drinking water is a local and worldwide concern. Although DAF has been effectively applied for the removal of suspended solid, its application for the treatment of dissolved organic carbon is very limited. In this study, a new hybrid system consisting of adsorption and DAF processes was introduced for the simultaneous removal of algae and taste and odor-causing organics. Powdered activated carbon (PAC) was used as an adsorbent. In this proposed system, the major concern of eliminating the spent PAC from the system was also addressed. It was found that zeta potential of algae and PAC was increased with coagulant dosage, and the removal efficiency in DAF was also enhanced up to 90~95% under the given experimental conditions. Based on this study, the hybrid process was found to be a promising technology for the simultaneous removal of algae and dissolved organic pollutants.

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • 한국GIS학회:학술대회논문집
    • /
    • 한국GIS학회 2004년도 GIS/RS 공동 춘계학술대회 논문집
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

$PM_{10}$개인노출과 공중이용시설내 농도에 관한 연구 (Personal Exposure to $PM_{10}$ and its Concentration in Public Facilities)

  • 김만구;정영림;임양석
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.185-190
    • /
    • 1998
  • $PM_{10}$ concentrations were measured In underground stores located In 4 major cities, Chunchon, Wonju, Donghae and Sockcho, In Kangwon-Do using scattering light Integated type digital dust indicator. Per- sonal exposure to $PM_{10}$ for two women(housekeeper and gaduate students and a man(undergraduate student) were measured also. The dimensional conversion factors for mass concentrations(K) showed some difference among un- derground stores which were 2.0, 2.7, 3.4, 2.6 mg/$m^2$.CPM In chunchon, Wonju, Donghae and Sockcho, respectively. Average PMlo concentrations at underground stores were 178mg/$m^2$ in Chunchon, 141mg$m^2$ in Wonju, 125 mg/$m^2$ Donghe and 59mg/$m^2$) Sockcho. The portion of $PM_{10}$ In total suspended particles was about 50~60% as deight The exposure of graduate student, housekeeper and undergraduate to $PM_{10}$ during 12 hours were 1004. 3 (mg/$m^2$) .hr, 907.0 (mg/$m^2$) hr and 691.2 (mg/$m^2$) hr, respectively. Personal exposure to $PM_{10}$ showed very different according to heP activity pattern and they had more than 90 % of their $PM_{10}$ exposure at Indoor environment.

  • PDF

미세부유사의 수력학적 연구 활용을 위한 흡착성 방사성표지물로서의 99mTc 제조기법 연구 (Reserach of a Labelling Technique for Using 99mTc as an Adsorbable Radiotracer for Hydrodynamics Studies of Fine Sediments in Suspension)

  • 정성희;김종범;문진호;홍영돈
    • 방사선산업학회지
    • /
    • 제4권1호
    • /
    • pp.13-17
    • /
    • 2010
  • The radioisotope labelling study was carried out for the sediment transport investigation. The fate of suspended solid materials is deeply related to the harbour siltation and the shoreline deformation that take place as a result of the artificial development of coastal area. In the experiment, $^{99m}TcO_4{^-}$ was chemically reduced and labelled in such a way that the labelled particles have the similar settling characteristics with the natural sediment. The radioisotope labelling techniques can be widely used for the natural resource exploration where the hydraulic dynamics of underground water and surface water are of importance.

황산법을 이용한 루틸형 TiO2 분말의 제조 및 특성 평가 (Synthesis and Characterization of Rutile TiO2 Powder by the Sulfuric Acid Method)

  • 최순옥;조지희;김원용;임성환
    • 대한금속재료학회지
    • /
    • 제50권7호
    • /
    • pp.523-530
    • /
    • 2012
  • We investigated the experimental method that uses the homogeneous precipitation method to prepare mica flakes-coated rutile-type titania pearlescent pigment with urea as a precipitant. $TiO_2$ particles exhibit a high reflection of lights and optical properties with chemical stabilities, so they are appropriate for coating on luminescent pigments (mica). The coating principle of mi ca coated titania with various thicknesses was analyzed by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and tested by spectrophotometer. Mica with a particle size in the range of $40-60{\mu}m$ was suspended in water, and metal sulphates and urea were added to the mixture, which was heated to boiling. The change in pH was continuously followed. The metal oxide and crystal structure were affected by the conditions of $TiOSO_4$ concentration and reaction time with a sintering temperature the range of $800-1100^{\circ}C$.