• Title/Summary/Keyword: Suspended Particulate

Search Result 263, Processing Time 0.03 seconds

The Application of CMB Model for Particulate Source Apportionment (분진오염원 할당을 위한 CMB모형의 적용)

  • 정장표;정창용
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.393-402
    • /
    • 1994
  • It is necessary to examine the source contributions and the relationship between a receptor and sources for the resonable controlling of air pollution level of suspended particulate matters. Therefore, in this study, profiles of sources contributing to the concentration of suspended particulate matters, were developed and CMB model was applied to obtain information of source contributions and feasibility of CMB model application. According to the propose of this study, twenty-seven chemical species such as the elements, anions, and total carbon of thirty-six PMl0 and TSP data sets sampled at the Pomch'on receptor site in Pusan for a 24-hr period from May to Aug. 1992, were analyzed and three (transportation, soil, marine) different source profiles were developed through the field measurement. Applying CMB model to transportation, soil, marine, the results of source contribution by CMB model showed that the case with TSP was more suitable for CMB model than that with PMl0. And the average contribution of transportation source to TSP and PMlo concentration at Pomch'on receptor was calculated as 90.66 ㎍/m3(64%) and 23.27 ㎍/m3(39%), resfiectively, which showed that the contribution by transportation was dominant. The validation of CMB model was performed by means of the results of contributions from marine source for the wind direction sectors.

  • PDF

Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area (대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성)

  • 백성옥;송희봉
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF

Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area (서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.2
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

A Study on the Indoor Air Pollution of Singing Room and PC Room (노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구)

  • 이주상;원정일;이철민;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.

Temporal Variation of Particulate Matters and PAHs in Seoul (서울지역에서 대기 중 분진 및 입자상 PAHs 농도의 시간적 분포 특성)

  • 송은주;이유진;최지예;이지이;김용표
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.341-342
    • /
    • 2003
  • 대기 중의 부유분진 (suspended particulate matters)은 대기오염을 측정하는 일반지표 중의 한 항목으로, 보통 대기의 단위부피당 질량으로 그 오염정도를 판단하고 있다. 대기 중 부유분진은 입경별 농도분포에 따라 통해 오염원의 특성을 파악할 수 있고, 여러 오염원에서 배출되어지는 여러 화학물질들로 구성되어 있기 때문에 인체 위해성 측면에서 많은 관심의 대상이 되어 왔다. 또한 다환방향족탄화수소 (Polycyclic Aromatic Hydrocarbons, PAHs)는 환경에 존재하는 중요한 발암물질이자 돌연변이 유도체이다.(중략)

  • PDF

Trace Metals of Suspended Particulate Matters in the Keum River (금강 부유물중 미량 금속의 함량과 이동)

  • 최만식;이창복
    • 한국해양학회지
    • /
    • v.30 no.5
    • /
    • pp.371-381
    • /
    • 1995
  • To investigate the concentrations and transport patterns of particulate metals in river suspended matters, eighteen samples were collected from a fixed station located in the upper part of the Keum River through one year, and analysed for major elements (AI, Fe, P, Mn) and trace elements (Cr, Co, Ni, Cu, Zn, Cd, Pb, U). The contents of metals in suspended particulate matters (SPM) varied greatly with season and SPM load; maximum value in winter with low SPM level and minimum value in flood period and in spring Yangtze SPMs. The different trace metal level between rivers of Korea and China may be caused by the different geology of drainage basin(U) and by the different extent of anthropogenic input (Mn, Pb). Most of all particulate metals (>70%) except Mn, P and Cd were transported in the flood period with high water discharge and high suspended load. The magnitude of each transport phase (dissolved, non-detrital and detrital metals) was compared. The portions of labile metals (dissolved plus non-detrital metals) in the aquatic environment were in the range of 50%(Co) to 92%(Mn) of total metal transport and in the rank of Mn>Cd, U>Cu>Zn>Ni>Pb>Co.

  • PDF

Atmospheric Concentration and Size Distribution of Airborne Particulates, Benzopyrene and Heavy Metals (대기(大氣) 중 Benzopyrene 및 중금속(重金屬)의 농도(濃度)와 입경분포(粒徑分布))

  • Heo, Moon-Young;Kweon, Chang-Ho;Yu, Ki-Seon;Choi, Seong-Kyu;Kweon, Chang-Ho;Kim, Kyeong-Ho;Sohn, Dong-Hun
    • YAKHAK HOEJI
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 1990
  • Total suspended particulate (TSP) in the atmosphere was collected and size-fractionated by Andersen high volume air sampler for the past two years (Mar. 1987-Feb. 1989) in Seoul. The concentrations of several polycyclic aromatic hydrocarbons and heavy metals were determined to investigate the atmospheric concentrations, seasonal variations and its relationship with the size distribution of suspended particulate matter. The arithmetic mean concentration of total suspended particulate was $229.48\;{\mu}g/m^3$. The concentrations of heavy metals were $2971.94\;ng/m^3$ for Fe, $767.75\;ng/m^3$ for Zn, $765.80\;ng/m^3$ for Pb, $218.40\;ng/m^3$ for Cu, $129.91\;ng/m^3$ for Mn, respectively. And the concentration of PAHs were $3.23\;ng/m^3$ for benzo(a)pyrene, $2.71\;ng/m^3$ for benzo(k)fluoranthene, $4.53\;ng/m^3$ for benzo(ghi)perylene, respectively. The mass-size distribution of TSP was lowest in the particle size range $1.1-3.3\;{\mu}m$ increased as the particle size increased or decreased. But PAHs, Pb and Zn abounded in particles below $2.0\;{\mu}m$, while Fe and Mn abouned in particles above $2.0\;{\mu}m$. TSP and its chemical compositions showed the seasonal variations. The concentrations of anthrophogenic origin like TSP, PAH and heavy metals in the fine particles were highest in winter and lowest in summer. PAH and Ph analyzed showed significant correlations with each other and with TSP concentration in fine particles, indicating that the particles in which they are contained have a similar behavior in the atmosphere.

  • PDF

Quantitative Source Estimation of Particulate Matters in Suwon Area Using the Target Transformation Factor Analysis Based on Size Segregation Scheme (입경 분류에 입각하여 목표변환 인자분석법을 이용한 수원지역 분진 오염원의 정량적 기여도 추정)

  • 김동술;이태정
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.44-50
    • /
    • 1993
  • The suspended particulate matters had been collected by a cascade impactor having 9 size fragnated stages for 2 years (Dec. 1989 to Nov. 1991) in Kyung Hee University-Suwon Campus. The particulate matters were then collected on each stage by membrane filters. The weight concentration on each stage was estimated by a microbalance and further chemical element concentrations were determined by an XRF system. The study focused on developing of a receptor model using the TTFA (target transformation factor analysis) to apportion aerosol mass with the 30 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 13 element variables. Even though a couple of sources could not be identified, three to five sources were extracted from each aerosol size-range, and then 9 statistical source profiles were generated. Finally, source contribution of particulate matters on each size-range could be estimated in Suwon area.

  • PDF

A Study on the Sediment Flux in Gwangyang Bay during Spring Tide, March 2003 (2003년 3월 대조기 광양만 부유퇴적물의 유 · 출입에 관한 연구)

  • KIM Seok Yun;LEE Byoung Kwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.511-516
    • /
    • 2004
  • As a preliminary study on the sediment flux, concentrations of suspended particulate matter and current speeds were measured at three inlets of Gwangyang Bay during one tidal cycle of a spring tide of March 2003. The suspended sediment flux rate $(g/m^{2}/s)$ at the mouth of Seomjin River (St. K1) was observed to be higher throughout surface layer during ebb tide $(14.3\;g/m^{2}/s)$ and throughout near-bottom layer during the flood tide $(23.2\;g/m^{2}/s),$ resulting in a net upstream-ward transport of$0.9{\times}10^{3}kg/m$ during 13 period. At the inlet toward Yeosu Bay (St. K2), a relatively low rate ($(5.0-6.7\;g/m^{2}/s)$ of sediment flux occurred throughout the water column compared to St. K1, with a depth-integrated net transport of $5.6{\times}10^{3}kg/m$ toward the outer reaches of Gwangyang Bay inlet. At St. K3 located at Gwangyang Bay-side of Noryang Strait, the outward flux toward the Jinju Bay was observed to be dominant during the flood tide $(16.2-23.2\;g/m^{2}/s)$, especially through the mid and near bottom layer, compared to the inward flux throughout the whole water column during the ebb tide $(13.1-19.7\;g/m^{2}/s).$ The net transport at St. K3 was calculated to be $4.0{\times}10^{3}kg/m$ toward the outside of Gwangyang Bay. The outward net transport of suspended sediment at all three inlets seems to be consistent with a trend of bottom sediment texture, which suggests a net movement of sediment from a relatively coarse and poorly sorted inner-bay toward a relatively fine and better sorted outer-bay environment.

Effects of Mixed Characteristics of Oily Soil on Detergency of PET Fabric in Oily/Particulate Soil Mixed System (지용성/고형오구의 혼합오염계에서 지용성오구의 혼합특성에 따른 PET직물의 세척성)

  • Kang, In-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.10
    • /
    • pp.1242-1251
    • /
    • 2011
  • This study investigates the effect of mixed characteristics of oily soil such as mixed ratio, polarity of oily soil on contact angle of fabric, removal of oily and particulate soil from PET fabric in oily/particulate soil mixed system. The contact angle of fabric in the surfactant solution with suspended oily soil was examined as a fundamental environment of detergency of soil from fabrics. Detergency was investigated as function of mixed ratios of oily/ particulate soil, type of oily soil, surfactants concentration, surfactant type and temperature of detergency in surfactant solution. The contact angle of fabric in surfactant solution sharply increased with mixing nonpolar oily soil; in addition, the contact angle slightly increased with increasing contents of oily soil and decreased with increasing surfactant concentration. The removal of oily and particulate soil from fabric was higher in the solution mixed with polar versus nonpolar oily soil. The detergency increased with increasing surfactant concentration and the increased temperature of surfactants solution that were relatively improved in NPE compared to DBS solutions, The results indicated that the detergency of oily and particulate soil showed a similar trend in oily/ particulate mixed soil systems. The general contact angle of fabric was well related with the detergency of oily and particulate soil in oily/particulate mixed soil system, therefore, the primary factor determining the detergency of soil in oily/particulate mixed soil system may be the contact angle of fabric caused by wettability.