• Title/Summary/Keyword: Surveillance imaging

Search Result 105, Processing Time 0.02 seconds

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

Clinical Application of $^{18}F-FDG$ PET in Cervix Cancer (자궁경부암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Oh, So-Won;Kim, Seok-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.101-109
    • /
    • 2008
  • Cervix cancer is one of common gynecological cancers in the world, and staged with FIGO or TNM system. However, these clinical staging systems lack information about lymph node or distant metastases, thus imaging modalities are considered to make an appropriate therapeutic plan and enhance overall survival rate. In this context, FDG PET is recommended to pre-treatment stating and prognosis prediction, for it could noninvasively evaluate the status of lymph nodes, especially abdominal paraaortic nodes which are closely related with prognosis. Moreover, the degree of FDG uptake is correlated with prognosis. Although there is no consistent method for surveillance of cervix cancer, FDG PET seems a very important tool in detecting tumor recurrence because it is much more advantageous than conventional imaging modalities such as MRI for discerning recurrent tumor from fibrosis caused by radiation or surgery. Furthermore, FDG PET could be used to evaluate treatment response. On the other hand, recently introduced PET/CT is expected to play an ancillary role to FIGO staging by adding anatomical information, and enhance diagnostic performance of PET by decreasing false positive findings.

Correlation of CT Perfusion Images with VEGF Expression in Solitary Brain Metastases

  • Zhang, Jian-Hua;Wang, Ming-Sheng;Pan, Hai-Hong;Li, Shu-Feng;Wang, Zhong-Qiu;Chen, Wang-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1575-1578
    • /
    • 2012
  • Objectives: To obtain permeability surface (PS) values using multi-slice helical CT perfusion imaging and to evaluate the spatial distribution correlation between PS values and vascular endothelial growth factor (VEGF) expression in solitary brain metastases. Methods: Imaging was performed on 21 patients, PS values being calculated from the central, border and peripheral parts of tumours. VEGF expression was determined by immunohistochemical staining. Results: Rim enhancement was found in 16 cases, the border of the tumour featuring PS elevation with high VEGF expression in 13 cases. In the 5 cases with nodular enhancement, the border and the central part had high permeability and VEGF expression was high in all cases, the correlation being significant (P<0.01). Conclusion: VEGF expression in brain metastases positively correlates with PS values from CT perfusion imaging, so that the latter can be used in the surveillance of angiogenic activity in brain metastases.

Thermal Imaging Fire Detection Algorithm with Minimal False Detection

  • Jeong, Soo-Young;Kim, Won-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.5
    • /
    • pp.2156-2170
    • /
    • 2020
  • This paper presents a fire detection algorithm with a minimal false detection rate, intended for a thermal imaging surveillance environment, whose properties vary depending on temporal conditions of day or night and environmental changes. This algorithm was designed to minimize the false detection alarm rate while ensuring a high detection rate, as required in fire detection applications. It was necessary to reduce false fire detections due to non-flame elements occurring when existing fixed threshold-based fire detection methods were applied. To this end, adaptive flame thresholds that varied depending on the characteristics of input images, as well as the center of gravity of the heat-source and hot-source regions, were analyzed in an attempt to minimize such non-flame elements in the phase of selecting flame candidate blocks. Also, to remove any false detection elements caused by camera shaking, one of the most frequently raised issues at outdoor sites, preliminary decision thresholds were adaptively set to the motion pixel ratio of input images to maximize the accuracy of the preliminary decision. Finally, in addition to the preliminary decision results, the texture correlation and intensity of the flame candidate blocks were averaged for a specific period of time and tested for their conformity with the fire decision conditions before making the final decision. To verify the fire detection performance of the proposed algorithm, a total of ten test videos were subjected to computer simulation. As a result, the fire detection accuracy of the proposed algorithm was determined to be 94.24%, with minimum false detection, demonstrating its improved performance and practicality compared to previous fixed threshold-based algorithms.

Moving Target Detection based on Frame Subtraction and Morphological filter with Drone Imaging (프레임 감산과 형태학적 필터를 이용한 드론 영상의 이동표적의 검출)

  • Lee, Min-Hyuck;Yeom, SeokWon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.4
    • /
    • pp.192-198
    • /
    • 2018
  • Recently, the use of drone has been increasing rapidly in many ways. A drone can capture remote objects efficiently so it is suitable for surveillance and security systems. This paper discusses three methods for detecting moving vehicles using a drone. We compare three target detection methods using a background frame, preceding frames, or moving average frames. They are subtracted from a current frame. After the frame subtraction, morphological filters are applied to increase the detection rate and reduce the false alarm rate. In addition, the false alarm region is removed based on the true size of targets. In the experiments, three moving vehicles were captured by a drone, and the detection rate and the false alarm rate were obtained by three different methods and the results are compared.

Foreground Extraction in Thermal Videos Based on Selective Histogram Bins (선택적 히스토그램 빈 기반 열화상 영상 전경 추출)

  • Yu, Gwang-Hyun;Zaheer, Muhammd Zaigham;Kim, Jin-Young;Sin, Do-Seong
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.757-770
    • /
    • 2018
  • Foreground extraction is the most significant step in thermal imaging based surveillance systems. This step needs to be efficient in terms of time and memory consumption in order for the system to provide real time results but usually this efficiency reciprocates with the accurateness of the ROI detection. In this study, novel selective histogram bins based two background & foreground separation approaches for thermal videos processing have been proposed which exploit the temporal-consistency property of the thermal images in a given environment and can save over 80% memory than their simplest counterpart temporal median filtering.

An Improved ViBe Algorithm of Moving Target Extraction for Night Infrared Surveillance Video

  • Feng, Zhiqiang;Wang, Xiaogang;Yang, Zhongfan;Guo, Shaojie;Xiong, Xingzhong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.12
    • /
    • pp.4292-4307
    • /
    • 2021
  • For the research field of night infrared surveillance video, the target imaging in the video is easily affected by the light due to the characteristics of the active infrared camera and the classical ViBe algorithm has some problems for moving target extraction because of background misjudgment, noise interference, ghost shadow and so on. Therefore, an improved ViBe algorithm (I-ViBe) for moving target extraction in night infrared surveillance video is proposed in this paper. Firstly, the video frames are sampled and judged by the degree of light influence, and the video frame is divided into three situations: no light change, small light change, and severe light change. Secondly, the ViBe algorithm is extracted the moving target when there is no light change. The segmentation factor of the ViBe algorithm is adaptively changed to reduce the impact of the light on the ViBe algorithm when the light change is small. The moving target is extracted using the region growing algorithm improved by the image entropy in the differential image of the current frame and the background model when the illumination changes drastically. Based on the results of the simulation, the I-ViBe algorithm proposed has better robustness to the influence of illumination. When extracting moving targets at night the I-ViBe algorithm can make target extraction more accurate and provide more effective data for further night behavior recognition and target tracking.

Proposal for Research Model of High-Function Patrol Robot using Integrated Sensor System (통합 센서 시스템을 이용한 고기능 순찰 로봇의 연구모델 제안)

  • Byeong-Cheon Yoo;Seung-Jung Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.77-85
    • /
    • 2024
  • In this dissertation, a we designed and implemented a patrol robot that integrates a thermal imaging camera, speed dome camera, PTZ camera, radar, lidar sensor, and smartphone. This robot has the ability to monitor and respond efficiently even in complex environments, and is especially designed to demonstrate high performance even at night or in low visibility conditions. An orbital movement system was selected for the robot's mobility, and a smartphone-based control system was developed for real-time data processing and decision-making. The combination of various sensors allows the robot to comprehensively perceive the environment and quickly detect hazards. Thermal imaging cameras are used for night surveillance, speed domes and PTZ cameras are used for wide-area monitoring, and radar and LIDAR are used for obstacle detection and avoidance. The smartphone-based control system provides a user-friendly interface. The proposed robot system can be used in various fields such as security, surveillance, and disaster response. Future research should include improving the robot's autonomous patrol algorithm, developing a multi-robot collaboration system, and long-term testing in a real environment. This study is expected to contribute to the development of the field of intelligent surveillance robots.

Prior to Breast MRI Guidelines in Korea, Where Were We?

  • Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.35-42
    • /
    • 2021
  • Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.

Usefulness of Endoscopic Imaging to Visualize Regional Alterations in Acid Secretion of Noncancerous Gastric Mucosa after Helicobacter pylori Eradication

  • Uno, Kaname;Iijima, Katsunori;Abe, Yasuhiko;Koike, Tomoyuki;Takahashi, Yasushi;Ara, Nobuyuki;Shimosegawa, Tooru
    • Journal of Gastric Cancer
    • /
    • v.16 no.3
    • /
    • pp.152-160
    • /
    • 2016
  • Purpose: Endoscopic diagnosis of gastric cancer (GC) that emerges after eradication of Helicobacter pylori may be affected by unique morphological changes. Using comprehensive endoscopic imaging, which can reveal biological alterations in gastric mucosa after eradication, previous studies demonstrated that Congo red chromoendoscopy (CRE) might clearly show an acid non-secretory area (ANA) with malignant potential, while autofluorescence imaging (AFI) without drug injection or dyeing may achieve early detection or prediction of GC. We aimed to determine whether AFI might be an alternative to CRE for identification of high-risk areas of gastric carcinogenesis after eradication. Materials and Methods: We included 27 sequential patients with metachronous GC detected during endoscopic surveillance for a mean of 82.8 months after curative endoscopic resection for primary GC and eradication. After their H. pylori infection status was evaluated by clinical interviews and $^{13}C$-urea breath tests, the consistency in the extension of corpus atrophy (e.g., open-type or closed-type atrophy) between AFI and CRE was investigated as a primary endpoint. Results: Inconsistencies in atrophic extension between AFI and CRE were observed in 6 of 27 patients, although CRE revealed all GC cases in the ANA. Interobserver and intraobserver agreements in the evaluation of atrophic extension by AFI were significantly less than those for CRE. Conclusions: We demonstrated that AFI findings might be less reliable for the evaluation of gastric mucosa with malignant potential after eradication than CRE findings. Therefore, special attention should be paid when we clinically evaluate AFI findings of background gastric mucosa after eradication (University Hospital Medical Information Network Center registration number: UMIN000020849).