• Title/Summary/Keyword: Surveillance imaging

Search Result 105, Processing Time 0.036 seconds

Spaceborne SAR System Design and Performance Analysis (위성 영상 레이다(SAR)시스템 설계와 성능분석)

  • Gwak, Yeong-Gil;Jeong, Cheol-Ho
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.26-39
    • /
    • 2006
  • A synthetic aperture radar (SAR) system can provide all-weather, day and night imaging capability, and thus, is very useful in surveillance for both civil and military applications. In this paper, the X-band spaceborne SAR system design procedure is introduced with the key design parameters for mission and system requirements characterized by the small satellite platform. The SAR imaging mode design technique is presented, and the design results are analyzed for standard mode performance evaluation. In line with the system requirements, the X-band SAR payload and ground reception/processing sub-systems are presented with the key design results and image applications examples. The designed small satellite SAR system shows the wide range of imaging capability, and proves to be an effective surveillance system in light-weight, high-performance and cost-effective points of view.

  • PDF

Metastatic Mature Teratoma and Growing Teratoma Syndrome in Patients with Testicular Non-Seminomatous Germ Cell Tumors

  • Daniel B. Green;Francisco G. La Rosa;Paul G. Craig;Francesca Khani;Elaine T. Lam
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1650-1657
    • /
    • 2021
  • Metastatic mature teratoma is a common radiologic and histopathologic finding after chemotherapy for metastatic non-seminomatous germ cell tumors. The leading theory for these residual tumors is the selective chemotherapy resistance of teratomas versus the high chemotherapy sensitivity of the embryonal components. Growing teratoma syndrome is a relatively rare phenomenon defined as an enlarging residual mass histologically proven to be a mature teratoma in the setting of normal serum tumor markers. Metastatic mature teratomas should be resected because of their malignant potential and occasional progression to growing teratoma syndrome with the invasion of the surrounding structures. CT is the preferred imaging modality for post-chemotherapy surveillance and should cover all sites of potential metastatic disease. This article reviews the clinical, pathologic, and multimodality imaging features of metastatic mature teratomas in patients with primary testicular non-seminomatous germ cell tumors.

Application of Police Video Equipment for Fighting Crime and Legal Trends (범죄 대응을 위한 경찰 영상장비의 활용과 법 동향)

  • Lee, Hoon;Lee, Won-Sang
    • Informatization Policy
    • /
    • v.25 no.2
    • /
    • pp.3-19
    • /
    • 2018
  • With the introduction of video cameras into law enforcement, a great deal of police organizations have adopted the technology in their routine crime prevention activities. The up-to-date systems of ambient surveillance energized by CCTV, police wearable cameras, drones, and thermal imaging devices enable the police to thoroughly monitor public spaces as well as to rigorously arrest on-scene criminals. These efforts to improve the level of surveillance are often met with public resistance raising concerns over citizens' rights to privacy. Recent studies on the use of police video equipment have constantly raised the issues related to the lack of applicable legal provisions, risk of personal information and privacy infringement as well as security vulnerabilities. In this regard, the present study attempted to review the public surveillance methods currently used by law enforcement agencies worldwide within the context of public safety and individual rights to privacy. Furthermore, the present study also discussed the legal boundaries of police use of video equipment to address public concerns over privacy issues.

Role of Multiparametric Prostate Magnetic Resonance Imaging before Confirmatory Biopsy in Assessing the Risk of Prostate Cancer Progression during Active Surveillance

  • Joseba Salguero;Enrique Gomez-Gomez;Jose Valero-Rosa;Julia Carrasco-Valiente;Juan Mesa;Cristina Martin;Juan Pablo Campos-Hernandez;Juan Manuel Rubio;Daniel Lopez;Maria Jose Requena
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.559-567
    • /
    • 2021
  • Objective: To evaluate the impact of multiparametric magnetic resonance imaging (mpMRI) before confirmatory prostate biopsy in patients under active surveillance (AS). Materials and Methods: This retrospective study included 170 patients with Gleason grade 6 prostate cancer initially enrolled in an AS program between 2011 and 2019. Prostate mpMRI was performed using a 1.5 tesla (T) magnetic resonance imaging system with a 16-channel phased-array body coil. The protocol included T1-weighted, T2-weighted, diffusion-weighted, and dynamic contrast-enhanced imaging sequences. Uroradiology reports generated by a specialist were based on prostate imaging-reporting and data system (PI-RADS) version 2. Univariate and multivariate analyses were performed based on regression models. Results: The reclassification rate at confirmatory biopsy was higher in patients with suspicious lesions on mpMRI (PI-RADS score ≥ 3) (n = 47) than in patients with non-suspicious mpMRIs (n = 61) and who did not undergo mpMRIs (n = 62) (66%, 26.2%, and 24.2%, respectively; p < 0.001). On multivariate analysis, presence of a suspicious mpMRI finding (PI-RADS score ≥ 3) was associated (adjusted odds ratio: 4.72) with the risk of reclassification at confirmatory biopsy after adjusting for the main variables (age, prostate-specific antigen density, number of positive cores, number of previous biopsies, and clinical stage). Presence of a suspicious mpMRI finding (adjusted hazard ratio: 2.62) was also associated with the risk of progression to active treatment during the follow-up. Conclusion: Inclusion of mpMRI before the confirmatory biopsy is useful to stratify the risk of reclassification during the biopsy as well as to evaluate the risk of progression to active treatment during follow-up.

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Subjective Imaging Effect Assessment for Intelligent Imaging Terminal Design: a Method for Engineering Site

  • Liu, Haoting;Lv, Ming;Yu, Weiqun;Guo, Zhenhui;Li, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.3
    • /
    • pp.1043-1064
    • /
    • 2020
  • A kind of Subjective Imaging Effect Assessment (SIEA) method and its applications on intelligent imaging terminal design in engineering site are presented. First, some visual assessment indices are used to characterize the imaging effect: the image brightness, the image brightness uniformity, the color image contrast, the image edge blur, the image color difference, the image saturation, the image noise, and the integrated imaging effect index. A linear weighted function is employed to carry out the SIEA computation and the Analytic Hierarchy Process (AHP) technique is used to estimate its weights. Second, a SIEA software is developed. It can play images after the settings of assessment index or assessment reaction time, etc. Third, two cases are used to illustrate the application effects of proposed method: the image enhancement system design for surveillance camera and the imaging environment perception system design for intelligent lighting terminal. A Prior Sequential Stimulus (PSS) experiment is proposed to improve the evaluation stability of SIEA method. Many experiment results have shown the proposed method can realize a stable system design or parameters setting for the intelligent imaging terminal in engineering site.

Congenital Absence of the Bilateral Internal Carotid Arteries: a Case Report

  • Noh, Jihoon;Kang, Hyunkoo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.3
    • /
    • pp.193-196
    • /
    • 2021
  • Congenital absence of the bilateral internal carotid arteries (ICA) is a very rare occurrence. Recognition of this rare anomaly is important, when considering intracranial endovascular interventions in the event of thromboembolic events with revascularization, transsphenoidal surgery, and the surveillance and detection of associated cerebral aneurysms. We report a case of a 25-year-old man who presented with headache since 2 years ago, and was incidentally discovered to have a congenital bilateral absence of ICAs.

Anomalous Origin of the Coronary Artery from the Pulmonary Artery in Children and Adults: A Pictorial Review of Cardiac Imaging Findings

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1441-1450
    • /
    • 2021
  • Anomalous origin of the coronary artery from the pulmonary artery is a rare and potentially fatal congenital heart defect. Up to 90% of infants with an anomaly involving the left coronary artery die within the first year of life if left untreated. Patients who survive beyond infancy are at risk of sudden cardiac death. Cardiac CT and MRI are increasingly being used for the accurate diagnosis of this anomaly for prompt surgical restoration of the dual coronary artery system. Moreover, life-long imaging surveillance after surgery is necessary for these patients. In this pictorial review, multimodal cardiac imaging findings of this rare and potentially fatal coronary artery anomaly are comprehensively discussed, and representative images are provided to facilitate the understanding of this anomaly.

A New 3D Active Camera System for Robust Face Recognition by Correcting Pose Variation

  • Kim, Young-Ouk;Jang, Sung-Ho;Park, Chang-Woo;Sung, Ha-Gyeong;Kwon, Oh-Yun;Paik, Joon-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1485-1490
    • /
    • 2004
  • Recently, we have remarkable developments in intelligent robot systems. The remarkable features of intelligent robot are that it can track user, does face recognition and vital for many surveillance based systems. Advantage of face recognition when compared with other biometrics recognition is that coerciveness and contact that usually exist when we acquire characteristics do not exist in face recognition. However, the accuracy of face recognition is lower than other biometric recognition due to decrease in dimension from of image acquisition step and various changes associated with face pose and background. Factors that deteriorate performance of face recognition are many such as distance from camera to face, lighting change, pose change, and change of facial expression. In this paper, we implement a new 3D active camera system to prevent various pose variation that influence face recognition performance and propose face recognition algorithm for intelligent surveillance system and mobile robot system.

  • PDF

Performance Characteristics of the High Resolution, X-band Small Stellite SAR System Design (X 밴드 고해상도 소형 위성탑재 SAR 체계설계와 성능특징)

  • 곽영길
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1258-1270
    • /
    • 2000
  • A synthetic aperture radar (SAR) system is able to provide all-weather, day-and-night, high resolution imaging capability in the wide area of interest, and thus is extremely useful in surveillance for both civil and military applications. In this paper, the X-band high-resolution spaceborne SAR system design is described with the key design parameters for the mission and system requirement characterized by the small satellite platform. The SAR imaging mode design technique is presented, and the standard imaging mode design results are analyzed with respect to image quality performance. In line with the system requirement, X-band SAR payload and ground reception/processing subsystems are designed and the key design results are demonstrated with the outstanding performance characteristics. The designed small satellite SAR system shows the wide range of imaging capability, and proves to be an effective surveillance systems in the light weight, high performance and cost-effective points of view.

  • PDF