• Title/Summary/Keyword: Surveillance imaging

Search Result 100, Processing Time 0.03 seconds

Outpatient Radioablation Therapy for Thyroid Cancer Patients with Minimal Radiation Exposure to the Family Members (갑상선암 환자의 방사선옥소 외래치료시 가족 구성원의 방사선량 측정)

  • Park, Hee-Myung;Jang, Jung-Woong;Yang, Hee-Chul;Kim, Young-Gook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.218-225
    • /
    • 2007
  • Purpose: Postoperative thyroid remnant radioablation therapy is necessary to reduce the recurrence and mortality rates as well as to prepare the patients for a proper long term surveillance of well-differentiated thyroid cancers. The radiation safety rules of the government require the patient to be isolated in a hospital if the expected radiation exposure to the family members would be greater than 5 mSv (500 mRem). The purpose was to measure the radiation received by the family members of patients who received large doses of NaI-131. Material and Methods: We have administered 12 therapy doses ranging from 3.70-5.55 GBq (100 to 150 mCi) to 11 patients, and released them immediately if they met the radiation safety criteria. Informed consent was obtained from the subjects prior to the therapy, and each of them agreed to follow written radiation safety instructions. TLD badges were used to measure the radiation dose received by the family members and the room adjacent to the patient's bed room during the first 72 hours. Results: The average dose received by the family members who spent the most time in the closest distance with the patients was 0.04 mSv with a range of 0.01-0.17 mSv. Even the highest dose was only about 3% of the limit set by the government. The average radiation dose to the outer wall of the patient's room was 0.15 mSv. Conclusion: It is concluded that I-131 ablation therapy can be administered to outpatients safely to thyroid cancer patients who meet the established radiation safety criteria and follow the instructions.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Clinical Outcome in Gamma Knife Radiosurgery for Metastatic Brain Tumors from the Primary Breast Cancer : Prognostic Factors in Local Treatment Failure and Survival

  • Choi, Seung Won;Kwon, Do Hoon;Kim, Chang Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.4
    • /
    • pp.329-335
    • /
    • 2013
  • Objective : Brain metastases in primary breast cancer patients are considerable sources of morbidity and mortality. Gamma knife radiosurgery (GKRS) has gained popularity as an up-front therapy in treating such metastases over traditional radiation therapy due to better neurocognitive function preservation. The aim of this study was to clarify the prognostic factors for local tumor control and survival in radiosurgery for brain metastases from primary breast cancer. Methods : From March 2001 to May 2011, 124 women with metastatic brain lesions originating from a primary breast cancer underwent GKRS at a tertiary medical center in Seoul, Korea. All patients had radiosurgery as a primary treatment or salvage therapy. We retrospectively reviewed their clinical outcomes and radiological responses. The end point of this study was the date of patient's death or the last follow-up examination. Results : In total, 106 patients (268 lesions) were available for follow-up imaging. The median follow-up time was 7.5 months. The mean treated tumor volume at the time of GKRS was 6273 $mm^3$ (range, 4.5-27745 mm3) and the median dose delivered to the tumor margin was 22 Gy (range, 20-25 Gy). Local recurrence was assessed in 86 patients (216 lesions) and found to have occurred in 36 patients (83 lesions, 38.6%) with a median time of 6 months (range, 4-16 months). A treated tumor volume >5000 $mm^3$ was significantly correlated with poor local tumor control through a multivariate analysis (hazard risk=7.091, p=0.01). Overall survival was 79.9%, 48.3%, and 15.3% at 6, 12, and 24 months, respectively. The median overall survival was 11 months after GKRS (range, 6 days-113 months). Multivariate analysis showed that the pre-GKRS Karnofsky performance status, leptomeningeal seeding prior to initial GKRS, and multiple metastatic lesions were significant prognostic factors for reduced overall survival (hazard risk=1.94, p=0.001, hazard risk=7.13, p<0.001, and hazard risk=1.46, p=0.046, respectively). Conclusion : GKRS has shown to be an effective and safe treatment modality for treating brain metastases of primary breast cancer. Most metastatic brain lesions initially respond to GKRS, though, many patients have further CNS progression in subsequent periods. Patients with poor Karnofsky performance status and multiple metastatic lesions are at risk of CNS progression and poor survival, and a more frequent and strict surveillance protocol is suggested in such high-risk groups.

Laser Tracking Analysis of Space Debris using SOLT System at Mt. Gamak (감악산 SOLT 시스템을 이용한 우주잔해물 레이저추적 성능분석)

  • Lim, Hyung-Chul;Park, Jong-Uk;Kim, Dong-Jin;Seong, Kipyung;Ka, Neung-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.830-837
    • /
    • 2015
  • Space debris has been a major issue recently for the space-active nations because its growing population is expected to increase the collision risk with operational satellites. Radar and electro-optical system has been used for space debris surveillance, which may cause unnecessary anti-collision manoeuvers due to their low tracking accuracy. So an additional tracking system is required to improve the predicted orbit accuracy and then to jude the anti-collision maneouvers more efficiently. The laser tracking system has been considered as an alternative to decrease these unnecessary manoeuvers. Korea Astronomy and Space Science Institute has been developing a space object laser tracking system which is capable of laser tracking for satellites with retro-reflectors and for space debris using high power laser, and satellite imaging using adaptive optics. In this study, the tracking capability is analyzed for space debris using high power laser based on link budget, false alarm probability and signal detection probability.

A Case Report of Intraductal Carcinoma Detected in a Patient Undergoing Surveillance for Benign Breast Mass (유방 양성 종괴 추적 관찰 환자에게서 발견된 관상피내암 증례 보고)

  • Il-Bong Moon;Jong-Gil Kwak;Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.743-749
    • /
    • 2023
  • Breast ductal carcinoma in situ(DCIS) refers to cases in which breast epithelial cells have become malignant but are still limited to normal ducts, and has been increasing rapidly in recent years. In this case, a two-year follow-up revealed findings on mammography and ultrasonography that indicated a small mass classified as BI-RADS Category 3, However far from typical malignant tumor these findings were. In the second year of follow-up, a hypoechoic mass with an indistinct boundary of the right breast in the 6 o'clock direction, on mammography appeared to be about 2.1×1.3 cm in size, and biopsy diagnosed it as ductal carcinoma. Since ductal endothelial cancer has no characteristic clinical findings and can show positive clinical and imaging findings in the early stages, regular follow-up is considered important for early diagnosis, and detection of ductal endothelial cancer through mammography and ultrasound is important for improving the prognosis of all breast cancer patients. During the initial examination conducted four years ago, we reported cases of intra ductal cancer in which asymmetric shading, microcalcification, and branched mass, indicative of intra ductal cancer, were observed during follow-up. It is advisable to concurrently explore methods for reducing X-ray dosage to mitigate potential side effects of contrast medium.

Sonographic Assessment of the Extent of Extrathyroidal Extension in Thyroid Cancer

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1187-1195
    • /
    • 2020
  • Objective: This study aimed to determine the sonographic features suggestive of extrathyroidal extension (ETE) of thyroid cancers. Materials and Methods: We retrospectively reviewed the sonographic images of 1656 consecutive patients who had undergone thyroidectomy in 2017. The diagnostic performance of sonographic features suggestive of ETE was evaluated using operation and histopathologic reports. Sonographic features for gross ETE to the strap muscle and minor ETE were assessed for thyroid cancer abutting the anterolateral thyroid capsule. Sonographic features for tracheal invasion were assessed according to whether the angle between the tumor and the trachea was an acute, right, or obtuse angle. Sonographic features for recurrent laryngeal nerve (RLN) invasion were assessed based on the association between the tumor and tracheoesophageal groove (TEG) as preserved normal tissue, abutting or protruding into the TEG. Results: ETE was observed in 783 patients (47.3%), including 123 patients with gross ETE (7.4% [strap muscle, n = 97; RLN, n = 24; and trachea, n = 14]) and 660 patients with minor ETE (39.9%). Regarding the diagnosis of gross and minor ETE to the strap muscle, sonographic features of replacement of the strap muscle and capsular disruption showed the highest positive predictive value (75.9% and 58.5%, respectively). Thyroid cancer forming an obtuse angle with the trachea had the highest sensitivity for the diagnosis of tracheal invasion (85.7%), and thyroid cancer protrusion into the TEG showed the highest sensitivity for the diagnosis of RLN (83.3%). Conclusion: Sonography is considered beneficial in the diagnosis of ETE to the strap muscle, trachea, and RLN. Assessment of ETE is important for the accurate staging of thyroid cancer, which in turn determines the extent of surgery or whether active surveillance is appropriate or not.

Impact of Skeletal Muscle Loss and Visceral Obesity Measured Using Serial CT on the Prognosis of Operable Breast Cancers in Asian Patients

  • Mi-ri Kwon;Eun Sook Ko;Min Su Park;Woo Kyoung Jeong;Na Young Hwang;Jae-Hun Kim;Jeong Eon Lee;Seok Won Kim;Jong Han Yu;Boo-Kyung Han;Eun Young Ko;Ji Soo Choi;Ko Woon Park
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.159-171
    • /
    • 2022
  • Objective: This study aimed to investigate the impact of baseline values and temporal changes in body composition parameters, including skeletal muscle index (SMI) and visceral adipose tissue area (VAT), measured using serial computed tomography (CT) imaging on the prognosis of operable breast cancers in Asian patients. Materials and Methods: This study retrospectively included 627 Asian female (mean age ± standard deviation [SD], 53.6 ± 8.3 years) who underwent surgery for stage I-III breast cancer between January 2011 and September 2012. Body composition parameters, including SMI and VAT, were semi-automatically calculated on baseline abdominal CT at the time of diagnosis and follow-up CT for post-treatment surveillance. Serial changes in SMI and VAT were calculated as the delta values. Multivariable Cox regression analysis was used to evaluate the association of baseline and delta SMI and VAT values with disease-free survival. Results: Among 627 patients, 56 patients (9.2%) had breast cancer recurrence after a median of 40.5 months. The mean value ± SD of the baseline SMI and baseline VAT were 43.7 ± 5.8 cm2/m2 and 72.0 ± 46.0 cm2, respectively. The mean value of the delta SMI was -0.9 cm2/m2 and the delta VAT was 0.5 cm2. The baseline SMI and VAT were not significantly associated with disease-free survival (adjusted hazard ratio [HR], 0.983; 95% confidence interval [CI], 0.937-1.031; p = 0.475 and adjusted HR, 1.001; 95% CI, 0.995-1.006; p = 0.751, respectively). The delta SMI and VAT were also not significantly associated with disease-free survival (adjusted HR, 0.894; 95% CI, 0.766-1.043; p = 0.155 and adjusted HR, 1.001; 95% CI, 0.989-1.014; p = 0.848, respectively). Conclusion: Our study revealed that baseline and early temporal changes in SMI and VAT were not independent prognostic factors regarding disease-free survival in Asian patients undergoing surgery for breast cancer.

Prediction of Decompensation and Death in Advanced Chronic Liver Disease Using Deep Learning Analysis of Gadoxetic Acid-Enhanced MRI

  • Subin Heo;Seung Soo Lee;So Yeon Kim;Young-Suk Lim;Hyo Jung Park;Jee Seok Yoon;Heung-Il Suk;Yu Sub Sung;Bumwoo Park;Ji Sung Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1269-1280
    • /
    • 2022
  • Objective: This study aimed to evaluate the usefulness of quantitative indices obtained from deep learning analysis of gadoxetic acid-enhanced hepatobiliary phase (HBP) MRI and their longitudinal changes in predicting decompensation and death in patients with advanced chronic liver disease (ACLD). Materials and Methods: We included patients who underwent baseline and 1-year follow-up MRI from a prospective cohort that underwent gadoxetic acid-enhanced MRI for hepatocellular carcinoma surveillance between November 2011 and August 2012 at a tertiary medical center. Baseline liver condition was categorized as non-ACLD, compensated ACLD, and decompensated ACLD. The liver-to-spleen signal intensity ratio (LS-SIR) and liver-to-spleen volume ratio (LS-VR) were automatically measured on the HBP images using a deep learning algorithm, and their percentage changes at the 1-year follow-up (ΔLS-SIR and ΔLS-VR) were calculated. The associations of the MRI indices with hepatic decompensation and a composite endpoint of liver-related death or transplantation were evaluated using a competing risk analysis with multivariable Fine and Gray regression models, including baseline parameters alone and both baseline and follow-up parameters. Results: Our study included 280 patients (153 male; mean age ± standard deviation, 57 ± 7.95 years) with non-ACLD, compensated ACLD, and decompensated ACLD in 32, 186, and 62 patients, respectively. Patients were followed for 11-117 months (median, 104 months). In patients with compensated ACLD, baseline LS-SIR (sub-distribution hazard ratio [sHR], 0.81; p = 0.034) and LS-VR (sHR, 0.71; p = 0.01) were independently associated with hepatic decompensation. The ΔLS-VR (sHR, 0.54; p = 0.002) was predictive of hepatic decompensation after adjusting for baseline variables. ΔLS-VR was an independent predictor of liver-related death or transplantation in patients with compensated ACLD (sHR, 0.46; p = 0.026) and decompensated ACLD (sHR, 0.61; p = 0.023). Conclusion: MRI indices automatically derived from the deep learning analysis of gadoxetic acid-enhanced HBP MRI can be used as prognostic markers in patients with ACLD.

A Study on the Density Analysis of Multi-objects Using Drone Imaging (드론 영상을 활용한 다중객체의 밀집도 분석 연구)

  • WonSeok Jang;HyunSu Kim;JinMan Park;MiSeon Han;SeongChae Baek;JeJin Park
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.69-78
    • /
    • 2024
  • Recently, the use of CCTV to prevent crowd accidents has been promoted, but research is needed to compensate for the spatial limitations of CCTV. In this study, pedestrian density was measured using drone footage, and based on a review of existing literature, a threshold of 6.7 people/m2 was selected as the cutoff risk level for crowd accidents. In addition, we conducted a preliminary study to determine drone parameters and found that the pedestrian recognition rate was high at a drone altitude of 20 meters and an angle of 60°. Based on a previous study, we selected a target area with a high concentration of pedestrians and measured pedestrian density, which was found to be 0.27~0.30 per m2. The study shows it is possible to measure risk levels by determining pedestrian densities in target areas using drone images. We believe drone surveillance will be utilized for crowd safety management in the near future.

Accuracy Analysis of Target Recognition according to EOC Conditions (Target Occlusion and Depression Angle) using MSTAR Data (MSTAR 자료를 이용한 EOC 조건(표적 폐색 및 촬영부각)에 따른 표적인식 정확도 분석)

  • Kim, Sang-Wan;Han, Ahrim;Cho, Keunhoo;Kim, Donghan;Park, Sang-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.457-470
    • /
    • 2019
  • Automatic Target Recognition (ATR) using Synthetic Aperture Radar (SAR) has been attracted attention in the fields of surveillance, reconnaissance, and national security due to its advantage of all-weather and day-and-night imaging capabilities. However, there have been some difficulties in automatically identifying targets in real situation due to various observational and environmental conditions. In this paper, ATR problems in Extended Operating Conditions (EOC) were investigated. In particular, we considered partial occlusions of the target (10% to 50%) and differences in the depression angle between training ($17^{\circ}$) and test data ($30^{\circ}$ and $45^{\circ}$). To simulate various occlusion conditions, SARBake algorithm was applied to Moving and Stationary Target Acquisition and Recognition (MSTAR) images. The ATR accuracies were evaluated by using the template matching and Adaboost algorithms. Experimental results on the depression angle showed that the target identification rate of the two algorithms decreased by more than 30% from the depression angle of $45^{\circ}$ to $30^{\circ}$. The accuracy of template matching was about 75.88% while Adaboost showed better results with an accuracy of about 86.80%. In the case of partial occlusion, the accuracy of template matching decreased significantly even in the slight occlusion (from 95.77% under no occlusion to 52.69% under 10% occlusion). The Adaboost algorithm showed better performance with an accuracy of 85.16% in no occlusion condition and 68.48% in 10% occlusion condition. Even in the 50% occlusion condition, the Adaboost provided an accuracy of 52.48%, which was much higher than the template matching (less than 30% under 50% occlusion).