• 제목/요약/키워드: Surrogate standard recoveries

검색결과 4건 처리시간 0.015초

대기 중 다환방향족탄화수소(PAHs)의 측정.분석 신뢰도 향상에 관한 고찰 (Study on Improvement in Reliability of Measurement and Analysis for Polycyclic Aromatic Hydrocarbons in the Atmosphere)

  • 이민도;임용재;이상욱;공부주;이상덕;한진석
    • 한국대기환경학회지
    • /
    • 제23권5호
    • /
    • pp.515-525
    • /
    • 2007
  • In this study, various techniques for measurement and analysis of PAHs in the ambient air were verified in order to select a more reliable method. Sampling and analysis of PAHs were done by the EPA TO-13a method. QA/QC of the measurement was conducted to minimize errors in sampling and analyzing processes. The linearity of calibration curve of the PAH standards was good ($R^2{\geq}0.99$). Audit accuracy was evaluated using 5 internal standards of PAHs ($Naphthalene-d_8,\;Acenaphthene-d_{10},\;Phenanthrene-d_{10},\;Chrysene-d_{12},\;Perylene-d_{12}$). Relative standard deviations of the internal standard of the PAHs were ranged from 6.22% for $acenaphthene-d_{10}$ to 8.11% for $chrysene-d_{12}$. To evaluate the surrogate recoveries, two field surrogate standards of PAHs ($fluoranthene-d_{10},\;benzo(a)pyrene-d_{12}$) and two extract surrogate standards of the PAHs ($fluorene-d_{10},\;pyrene-d_{12}$) were spiked into all samples before field sampling and sample extraction, respectively. Recoveries of field the surrogate standards ranged from $80.4{\pm}12.2%$ for $fluoranthene-d_{10}$ to $66.2{\pm}12.8%$ for $benzo(a)pyrene-d_{12}$. Extraction recoveries of the surrogate standards ranged from $70.4{\pm}10.2%$ for $fluorene-d_{10}$ to $77.6{\pm}10.8%$ for $pyrene-d_{10}$. The detection limit of benzo(a)pyrene among 16 PAHs standards for quantitation was 20 pg.

Determination of Icing Inhibitors (Ethylene Glycol Monomethyl Ether and Diethylene Glycol Monomethyl Ether) in Ground Water by Gas Chromatography-Mass Spectrometry

  • Shin, Ho-Sang;Jung, Dong-Gyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.806-808
    • /
    • 2004
  • A gas chromatography/mass spectrometric assay method has been developed for the simultaneous determination of icing inhibitors, ethylene glycol monomethyl ether and diethylene glycol monomethyl ether in ground water contaminated with JP-8. Ethylene glycol monobutyl ether and ethylene glycol monoethyl ether were used as the internal standard and surrogate, respectively. 100 mL of ground water was extracted twice with 20 mL of methylene chloride. The extract was concentrated to dryness, dissolved with 100 ${\mu}$L of methanol and analyzed by GC-MS (SIM). The use of an Innowax column gave the peaks good chromatographic properties, and the extraction of these compounds from samples gave recoveries of about 50% with small variations. The method detection limits of the target compounds were in a range of 0.5-0.8 ng/mL in ground water.

LC-MS/MS를 이용한 해수 및 수산용수 중 플루오로퀴놀론계 항생제 동시 분석법 정립 (Simultaneous Analysis of Prohibited Antibiotics (Fluoroquinolones) in Seawater and Effluents Released by Aquaculture Using LC-MS/MS)

  • 이미경;이인석;최민규;이성규;이원찬
    • 한국수산과학회지
    • /
    • 제56권4호
    • /
    • pp.428-437
    • /
    • 2023
  • A simultaneous analytical method was developed and validated for the analysis of prohibited fluoroquinolone (FQ) antibiotics including norfloxacin, ofloxacin, and pefloxacin, released by aquaculture in seawater and effluents. The samples were filtered, and extracts were obtained using a solid phase extraction cartridge with methanol (MeOH). The extracts were concentrated, and analyzed using ultra-performance liquid chromatography-tandem mass spectrometry. Two different columns and four different mobile phases were compared to achieve optimal separation and sensitivity for target compounds. Typical validation parameters including linearity, recovery of surrogate standard, instrument detection limit (IDL), limit of quantification (LOQ), and method detection limit (MDL) were evaluated. The linearity of calibration curves was over 0.999. Recoveries of surrogate ranged from 87.6% to 113%. The LOQ of target compounds was approximately 3-8 times lower than those reported in previous studies. The IDL and MDL were 0.06-0.57 and 0.06-0.37 ng/L, respectively. Seven effluent samples collected from an aquaculture located in Jeju were analyzed; however, not all target compounds were detected in the samples, suggesting that the banned antibiotics were not used. Overall, this established method was able to simultaneously analyze the three FQ antibiotics, and may be useful for monitoring prohibited antibiotics in the fishery industry.

Determination of trace icing Inhibitors (ether type) in free-floating fuels by gas chromatography-mass spectrometry

  • Shin, Ho-Sang;Ahn, Hye-Sil;Jung, Dong-Gyun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.196-200
    • /
    • 2003
  • A gas chromatography/mass spectrometric assay method was developed for the simultaneous determination of ethylene glycol monomethyl ether (EGME) and diethylene glycol monomethyl ether (DEGME) in spilled aviation fuels. Ethylene glycol monobutyl ether (EGBE) and ethylene glycol monoethyl ether (EGEE) were used as internal standard and surrogate, respectively. The sample preparation consists of back-extraction with 7 mL of methylene chloride after extraction of 50 mL of fuel with 2 mL of water. The extract was concentrated to dryness and dissolved with 100L of methanol and analyzed by CC-MS (SIM). The peaks had good chromatographic properties by using semi-polar column and the extraction of these compounds from fuel also gave high recoveries of 75 and 85 % with small variations for EGME and DEGME, respectively. Method detection limits were 1.3 ng/mL for EGME and 1.0 ng/mL for DEGME in spilled fuel. The method may be useful for fuel-type differentiation between kerosene and JP-8, which may originate from the storage tank.

  • PDF