• 제목/요약/키워드: Surgical valves

검색결과 67건 처리시간 0.022초

Single and Multiple Valve Surgery in Native Valve Infective Endocarditis

  • Kim, Tae Sik;Na, Chan-Young;Oh, Sam Sae;Kim, Jae Hyun;Yie, Gil Soo;Han, Jung Wook;Chae, Min Cheol
    • Journal of Chest Surgery
    • /
    • 제46권4호
    • /
    • pp.256-264
    • /
    • 2013
  • Background: Surgical treatment of infective endocarditis (IE) remains a challenge, especially in cases of multiple valve surgery. We evaluated the clinical outcomes of native valve IE and compared the outcomes of single valve surgery with those of multiple valve surgery. Materials and Methods: From 1997 to 2011, 90 patients underwent surgery for native valve IE; 67 patients with single valve surgery (single valve group) and 23 patients with multiple valve surgery (multiple valve group). The mean follow-up duration was $73.1{\pm}47.4$ months. Results: The surgical mortality in the total cohort was 4.4%. The overall survival (p=0.913) and valve-related event-free survival (p=0.204) did not differ between the two groups. The independent predictor of postoperative complications was New York Heart Association class (p=0.001). Multiple valve surgery was not a significant predictor of surgical mortality (p=0.225) or late mortality (p=0.936). Uncontrolled infection, urgent or emergency surgery, and postoperative complications were identified as independent predictors of valve-related morbidity, excluding multiple valve surgery (p=0.072). Conclusion: In native valve IE, multiple valve surgery as a factor was not an independent predictor of mortality and morbidity. The number of surgically corrected valves in native IE seems to be unrelated to perioperative and long-term outcomes.

심장판막증의 외과적 치료 (Clinical Analysis of Cardiac Valve Surgery)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제18권3호
    • /
    • pp.446-455
    • /
    • 1985
  • A total and consecutive 156 patients have undergone cardiac valve surgery including 13 closed mitral commissurotomy, 13 open mitral commissurotomy, one mitral annuloplasty, 75 mitral valve replacement, one aortic annuloplasty, 24 aortic valve replacement, 3 tricuspid valve replacement, 25 double valve replacement and one triple valve replacement. 155 prosthetic valves were replaced in a period between September 1976 and August 1985. There were 68 males and 88 females with age range from 8 to 69 yrs [mean 36.5 yr]. Out of replaced valves, 61 was tissue valve including 54 Carpentier-Edwards, and 4 was mechanical valves including 74 St. Jude Medical, and the position replaced was 101 valves for mitral, 46 for aortic and 8 for tricuspid. Single valve replacement in 102 cases, double valve replacement in 25 cases [17 for AVR+MVR, and 8 for MVR+TVR], and only one case was noted in the triple valve replacement. Early mortality within 30 days after operation was noted in 11 cases [7%]; 7 after MVR, 2 after DVR, and each one after open mitral commissurotomy and mitral annuloplasty. Cause of death was valve thrombus, cerebral air embolism, low output syndrome, uncontrollable arrhythmia, parapneumonic sepsis, acute cardiac tamponade and left atrial rupture. 7 late deaths were noted during the follow-up period from 1 to 104 months [average 48 month]; three due to valve and left atrial thrombus formation, two due to CVA from overdose of warfarin, and each one due to congestive heart failure and chronic constrictive pericarditis, Anticoagulants after prosthetic valve replacement were maintained with warfarin, dipyridamole and aspirin to the level of around 50% of normal prothrombin time in 79 cases, and Ticlopidine with aspirin in 47 cases to compare the result of each group. There were 11 major thromboembolic episodes including 3 deaths in the warfarin group. Two cases of CVA due to overdose of warfarin was noted in the warfarin group. In the ticlopidine group, there was only one left atrial thrombus confirmed at the time of autopsy. Among the survived 138 cases, nearly all cases[136 cases] were included in NYHA functional class I and II during the follow-up period. In conclusion, surgical treatment of the cardiac valve disease in 156 clinical cases revealed excellent result with acceptable operative risk and late mortality. Prevention of thrombus formation with anti-platelet aggregator Ticlopidine has better result than warfarin group presently with no specific side effect such as bleeding or gastrointestinal trouble.

  • PDF

A Knife Penetrating the Right Ventricle, Interventricular Septum, and 2 Valves: A Case Report

  • Megan Minji Chung;Stephanie Nguyen;Isao Anzai;Hiroo Takayama
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.456-459
    • /
    • 2023
  • Penetrating chest trauma may result in significant intracardiac injury. A traumatic ventricular septal defect is a rare complication that requires surgical management, particularly if heart failure ensues. We report a case of delayed repair of an outlet-type ventricular septal defect and perforation of the aortic and pulmonary valve leaflets following a stab wound. This report highlights diagnostic and surgical considerations and also presents an opportunity to review the conotruncal anatomy, which may be relatively unfamiliar to many adult cardiac surgeons.

Hancock 판막의 임상적 평가 (Clinical evaluation of the Hancock porcine xenograft valve)

  • 김종환
    • Journal of Chest Surgery
    • /
    • 제20권2호
    • /
    • pp.281-288
    • /
    • 1987
  • A total and consecutive 163 patients underwent cardiac valve replacement using the Hancock porcine xenograft cardiac valves from 1 976 to 1984. Of 198 substitute valves, 177 were the Hancock valves. One hundred twenty-nine patients[79.1%] had single valve replacement: MVR 118, AVR 8 and TVR 3; 33[20.3%] had double valve replacement: MVR+AVR 27 and MVR+TVR 6; and a single case had triple valve replacement. Other surgical procedures were added in 34 patients. The operative mortality rate within 30 days of surgery was 6.1%, and it was, however, 4.2%, with single MVR. Late mortality rate was 6.7% or 1.95%/patient-year of a linealized mortality rate. Early survivors of 153 patients were followed up for a total of 565.1 patient-years [a mean of 44.3*27.1 months]. The linealized annual complication rates were: 1.95% emboli/patient-year, 0.89% bleeding/patient-year 1.24% endocarditis/patient-year, and 4.25% overall failure/patient-year. Primary tissue failure occurred at a rate of 1.59%/patient-year. The actuarial survival rates including operative mortality were 87.0*4.1% and 77.3*6.6% at 5 and 11 years after surgery respectively. The probability of freedom from thromboembolic complication of 89.2*3.4% at 5 years after surgery lasted unchanged upto 11 years. The probability of freedom from overall valve failure was 81.3*4.5% at postoperative 5 years, and it dropped down to 26.2*19.4% at 11 years, although the latter was statistically insignificant because of a small number of patients entering into the years approaching the follow-up end. However, the probability of freedom from the primary tissue failure was 81.3*10.6% at postoperative 9 years, which coincides closely with the speculated rate of tissue degeneration of about 20% in 10 years. These clinical results confirm the low thrombogenicity of the Hancock porcine valve and the reasonable failure rate of tissue degeneration.

  • PDF

Early Outcomes of Sutureless Aortic Valves

  • Hanedan, Muhammet Onur;Mataraci, Ilker;Yuruk, Mehmet Ali;Ozer, Tanil;Sayar, Ufuk;Arslan, Ali Kemal;Ziyrek, Ugur;Yucel, Murat
    • Journal of Chest Surgery
    • /
    • 제49권3호
    • /
    • pp.165-170
    • /
    • 2016
  • Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was $71.15{\pm}8.60years$. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was $56.9{\pm}9.93$. The CPB time was $96.51{\pm}41.27minutes$ and the cross-clamping time was $60.85{\pm}27.08minutes$. The intubation time was $8.95{\pm}4.19hours$, and the intensive care unit and hospital stays were $2.89{\pm}1.42days$ and $7.86{\pm}1.42days$, respectively. The mean quantity of drainage from chest tubes was $407.69{\pm}149.28mL$. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was $687.24{\pm}24.76days$. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

선천성 대동맥판막하 막상협착증 치험 2례 (Surgical Correction of Discrete Membranous Suaorti Stenosis)

  • 송인기
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.532-536
    • /
    • 1990
  • We experienced surgical correction of 2 cases of discrete membranous subaortic stenosis. Case 1 was 19 years old male patient. His complaints were fatigue, exertional dyspnea, syncope and angina for 8 years. Ejection. systolic murmur was heard at the second right intercostal space and diastolic murmur was heard at the apex. A thrill was palpated over the second right intercostal space and area of the carotid artery. 2-D echo, cardiac cath and left ventriculogram revealed discrete membranous subaortic stenosis and VSD. Complete excision of discrete membrane without mymectomy was done. VSD was closed with dacron patch and aortic valve was replaced with St. Jude medical valve. Case 11 was 16 years old female whose complaints were exertional dyspnea and syncope. Ejection systolic murmur was heard at second right intercostal space, but diastolic murmur was not heard. A thrill was palpated over the second right intercostal space and the area of carotid artery. 2-D echo, cardiac cath and left ventriculogram revealed discrete membranous subaortic stenosis. Complete excision of fibrous tissue and myotomy were made and aortic valve was replaced with St. Jude medical valve. Operative finding was followed: both aortic valves showed deformity of leaflets. Subaortic region had a thickened central fibrous body from which the ridge protruded. Both patient`s postoperative course were uneventful and short-term follow-up results were good except soft systolic murmur at the aortic area.

  • PDF

Prognosis of Unrepaired Ascending Aorta after the Surgical Replacement of Bicuspid Aortic Valves

  • Hong Ju Shin;Wan Kee Kim;Dong Kyu Kim;Ho Jin Kim;Joon Bum Kim
    • Journal of Chest Surgery
    • /
    • 제56권4호
    • /
    • pp.255-261
    • /
    • 2023
  • Background: The surgical threshold for bicuspid aortic valve (BAV)-related aortopathy is a matter of debate due to its uncertain etiology and prognosis. This study investigated the prognosis of unrepaired BAV aortopathy in patients undergoing surgical aortic valve replacement (SAVR). Methods: We retrospectively analyzed data from 720 patients (age, 60.8±11.5 years; 246 women) who underwent SAVR for BAV disease without aortic repair between 2005 and 2020 at Asan Medical Center. The clinical endpoints were defined as occurrences of sudden death, aortic dissection or rupture, and elective aortic repair. To estimate postoperative changes in the dimensions of the unrepaired aorta, the individual annual aortic expansion rate was calculated. Multiple linear regression models were used to evaluate the risk of aortic expansion. Results: The mean ascending aortic diameter was 39.5±4.6 mm, and 299 patients (41.5%) had a baseline ascending aorta diameter >40 mm. During 70.0±68.3 months of follow-up, the mean annual aortic expansion rate was 0.39±1.96 mm/yr, no aortic dissection or rupture was observed, and sudden deaths were reported in 12 patients (0.34% per person-year). Linear regression analysis revealed no significant correlation between the baseline ascending aortic diameter and postoperative aortic expansion (R2=0.004, β=-0.84, p=0.082). Conclusion: In selected patients undergoing SAVR for a BAV (<55 mm), the risk of adverse aortic events was very low. As this observation contradicts current practice guidelines advocating for proactive aortic replacement in dilated ascending aortas measuring >45 mm, the study results need further validation by studies involving larger populations or randomized controlled trials.

판막질환을 동반한 관상정맥동 천정결손 증후군 - 수술 치험 1례 - (Unroofed Coronary Sinus Syndrome with Valvular Disease - Report of A Case -)

  • 박성달
    • Journal of Chest Surgery
    • /
    • 제23권1호
    • /
    • pp.162-168
    • /
    • 1990
  • Unroofed coronary sinus syndrome is an uncommon anomaly which is caused by incomplete formation of the left atriovenous fold and it is usually associated with persistent left superior vena cava. It may be diagnosed by cardiac catheterization and cineangiography but, if it is not diagnosed, it can bring out significant complications due to right to left shunt, such as brain abscess, cerebral embolism, transient ischemic attack, arterial desaturation and there will reduced patient`s life expectancy. Therefore corrective operation was needed. A case of unroofed coronary sinus syndrome which combines with valvular heart disease was experienced at the department of thoracic & cardiovascular surgery of Kosin medical college. The patient was 49 years old female and she complained dyspnea on exertion for 2 yrs. Cardiac catheterization with cineangiography and both superior venacavogram were performed for diagnosis and she was diagnosed as unroofed coronary sinus syndrome combined with mitral and tricuspid regurgitation. Surgical correction was accomplished by reroofing of coronary sinus with pericardial patch, closure of atrial septal defect and annuloplasty of both atrioventricular valves. Postoperative results were satisfactory and course of recovery was uneventful. We report a case of unroofed coronary sinus syndrome with review.

  • PDF

The Prognostic Significance of Patient-Prosthesis Mismatch after Aortic Valve Replacement

  • Nardi, Paolo;Russo, Marco;Saitto, Guglielmo;Ruvolo, Giovanni
    • Journal of Chest Surgery
    • /
    • 제51권3호
    • /
    • pp.161-166
    • /
    • 2018
  • Patient-prosthesis mismatch (PPM) is a controversial issue in current clinical practice. PPM has been reported to have a negative impact on patients' prognosis after aortic valve replacement in several studies, showing increased all-cause and cardiac mortality. Moreover, a close relationship has recently been described between PPM and structural valve deterioration in biological prostheses. In patients at risk for PPM, several issues should be considered, and in the current era of cardiac surgery, preoperative planning should consider the different types of valves available and the various surgical techniques that can be used to prevent PPM. The present paper analyses the state of the art of the PPM issue.

St. Jude Medical 기계판의 임상적 연구 (Surgical Experience on St. Jude Medical Valve Replacement)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제21권2호
    • /
    • pp.283-290
    • /
    • 1988
  • St. Jude Medical cardiac valve replacement was performed in 90 consecutive patients from Jan. 1984 to Dec. 1987. 54 had mitral, 12 had aortic and 24 had multiple valve replacement. Follow up extended for 1 to 47 months[mean 17.1 month] with a cumulative period of 1351 months. The overall actuarial survival rate at 4 years was 87.1% and overall hospital mortality was 6.7%. The linearlized incidence of thrombotic obstruction, thromboembolism, valve failure was 0.8% / pt. yr. each. The lower incidence of valve related mortality or morbidity was statistically significant. The performance of the St. Jude Medical mechanical valve was excellent compared to other substitute valves and has low incidence of thromboembolism or valve failure.

  • PDF