• 제목/요약/키워드: Surgical stabilization

검색결과 103건 처리시간 0.026초

흉·요추 불안정성 척추 손상 환자에서 전방 감압술과 전방기기 및 Surgical Titanium Mesh를 이용한 내고정술 (장기적 추적 검사 결과) (Anterior Decompression and Internal Fixation with Anterior Instrument and Surgical Titanium Mesh in Thoracolumbar Unstable Spine Injuries (Long-term Follow-up Results))

  • 박환민;이승명;조하영;신호;정성헌;송진규;장석정
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권1호
    • /
    • pp.58-65
    • /
    • 2000
  • Objective : Thoracolumbar junction is second most common level of injury next to cervical spine. The object of this study is to study the usefulness of surgical titanium mesh instead of bone graft, as well as to evaluate the correction of spinal deformity and safety of early ambulation in patients with injury at thoracolumbar junction. Patients and Methods : This review included 51 patients who were operated from July 1994 to December 1997. The injured spine is considered to be unstable, if it shows involvement of two or more columns, translatory displacement more than 3.5mm, decrease more than 35% in height of vertebral body and progression of malalignment in serial X-ray. The decision to operate was determined by (1) compression of spinal cord or cauda eguina, (2) unstable fracture, (3) malalignment and (4) fracture dislocation. The procedure consisted of anterior decompression through corpectomy and internal fixation with anterior instrument and surgical titanium mesh which was impacted with gathered bone chip from corpectomy. Results : Fifty-one patients were followed up for at least 12 months. The main causes of injury were fall and vehicle accident. The twelfth thoracic and the first and the second lumbar vertebrae were frequently involved. Complete neural decompression was possible under direct vision in all cases. Kyphotic angulation occurred in a patient. Radiologic evaluation showed correction of deformity and no distortion or loosening of surgical titanium mesh with satisfactory fixation postoperatively. Conclusions : We could obtain neurological improvement, relief of pain, immediate stabilization and early return to normal activities postoperatively. Based on these results, authors recommend anterior decompression and internal fixation with surgical titanium mesh in thoracolumbar unstable spine injuries.

  • PDF

자가 이식을 이용한 매복 견치의 치험례: 증례보고 (AUTOTANSPLANTATION OF IMPACTED MAXILLARY CANINES: CASE REPORTS)

  • 고윤식;김지연;박기태
    • 대한소아치과학회지
    • /
    • 제38권4호
    • /
    • pp.435-440
    • /
    • 2011
  • 상악 견치의 매복은 소아치과 의사가 흔히 접할 수 있는 맹출장애이며, 이를 방치하였을 경우 인접치의 치근 흡수, 낭종 형성 등의 임상적인 문제점을 유발할 수 있다. 이에 대한 치료는 간단한 유치 발치에서부터 매복치아의 교정적 견인, 외과적 자가이식 등 다양한 방법을 고려할 수 있다. 이 중 자가 이식은 매복치아가 교정적 견인술을 시행하기 어려운 위치에 존재하거나 재위치 시키는데 실패했을 경우에 매복치아의 발거에 앞서 고려할 수 있으며, 그 예후는 치근의 완성도, 환자연령, 외과적 술식, 근관치료 시기, 치아고정 기간 등에 의해 결정된다. 본 두 증례들은 혼합치열기 말기에 상악 견치가 매복된 환자에서 그 매복 위치가 자발적인 맹출 유도나 교정적 견인 및 배열이 어렵다고 판단된 경우이며, 자가 이식 후 근관치료와 교정 치료를 시행하고 현재까지 성공적으로 유지되고 있어 보고하는 바이다.

A Contrast Nephropathy in a Preterm Infant Following Preoperative Embolization of Giant Sacrococcygeal Teratoma

  • Lee, Byong Sop
    • Childhood Kidney Diseases
    • /
    • 제21권1호
    • /
    • pp.26-30
    • /
    • 2017
  • Newborn infants with huge and highly vascular sacrococcygeal teratoma (SCT) are frequently subjected to renal hypoperfusion secondary to high-output cardiac failure. Any underlying renal dysfunction is a significant risk factor for the development of contrast-induced nephropathy (CIN). However, reports on CIN in infants are rare. I report here a case of a premature infant born at 28 weeks and 3 days of gestation with a huge SCT who survived preoperative embolization and surgical resection but presented with persistent non-oliguric renal failure that was suggestive of CIN. During radiological intervention, a contrast medium had been administered at about 10 times the manufacturer-recommended dose for pediatric patients. Despite hemodynamic stabilization and normalization of urine output immediately following surgery, the patient's serum creatinine and cystatin-C levels did not return to baseline until 4 months after birth. No signs of reflux nephropathy were observed in follow-up imaging studies. Dosing guidelines for the use of a contrast medium in radiological interventions should be provided for infants or young patients.

Clinical Experience of Traumatic C7-T1 Spondyloptosis

  • Lee, Dong-Geun;Hwang, Soo-Hyun;Lee, Chul-Hee;Kang, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.127-129
    • /
    • 2007
  • Two unusual cases of traumatic spondyloptosis of the cervical spine at the C7-T1 level are reported. One patient was treated with a single-stage combined anterior-posterior and anterior operation to achieve realignment of the cervical spondyloptosis, decompression of the spinal cord and keep of a three-column stabilization of the spine. The other patient was treated with conservative management that consisted of a rigid neck collar and pain control for two months. The patients were managed successfully and both had good neurological outcomes. We present here a summary of the clinical presentations, the surgical technique and results, and a review of the relevant literature.

Lumbo-sacro-pelvic Fixation Using Iliac Screws for the Complex Lumbo-sacral Fractures

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권6호
    • /
    • pp.495-498
    • /
    • 2007
  • Fractures of lumbo-sacral junction involving bilateral sacral wings are rare. Posterior lumbo-sacral fixation does not always provide with sufficient stability in such cases. Various augmentation techniques including divergent sacral ala screws, S2 pedicle screws and Galveston rods have been reported to improve lumbo-sacral stabilization. Galveston technique using iliac bones would be the best surgical approach especially in patients with bilateral comminuted sacral fractures. However, original Galveston surgery is technically demanding and bending rods into the appropriate alignment is time consuming. We present a patient with unstable lumbo-sacral junction fractures and comminuted U-shaped sacral fractures treated by lumbo-sacro-pelvic fixation using iliac screws and discuss about the advantages of the iliac screws over the rod system of Galveston technique.

Minimally Invasive Stabilization with Percutaneous Screws Fixation of APC-3 Pelvic Ring Injury

  • Kim, Beom-Soo;Oh, Jong-Keon;Cho, Jae-Woo;Yeo, Do-Hyun;Cho, Jun-Min
    • Journal of Trauma and Injury
    • /
    • 제32권1호
    • /
    • pp.60-65
    • /
    • 2019
  • Pelvic fractures are associated with life-threatening injuries and high rates of morbidity and mortality. Management of internal blood loss associated with unstable pelvic ring injuries is paramount during the initial period. The reconstruction of the pelvic ring is of importance because it is a major contributor to the stability of the pelvic ring. We report the case of a 25-year-old man who had an unstable pelvic ring fracture combined with rupture of an obturator artery and had a successful and satisfactory treatment using minimally invasive surgery with percutaneous antegrade screw fixation.

The Vestibuloplasty Using Non-eugenol-based Non-zinc Oxide Oral Dressing Material

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of Korean Dental Science
    • /
    • 제14권1호
    • /
    • pp.46-50
    • /
    • 2021
  • This study describes a patient with insufficient vestibular depth who was operated with a vestibuloplasty using a non-eugenol-based non-zinc oxide oral dressing material. Partial thickness flap was elevated on recipient. After stabilization of apical positioned flap, the dressing material was applied on the recipient site with additional fixation by suture. The patient presented minimal discomfort such as in pain, food impaction and management of oral hygiene. Adequate vestibular depth without relapse was observed until 4 weeks after surgery. The vestibuloplasty with the oral dressing material may be an option for obtaining proper vestibular depth without complications.

외상환자의 치료에서 외상 전문간호사 도입 결과 (Outcomes for Employment of a Trauma Clinical Nurse Specialist in the Treatment of Trauma Patients)

  • 정윤중;김영환;김태현;금민애;마대성;경규혁;김정재;홍석경
    • Journal of Trauma and Injury
    • /
    • 제25권4호
    • /
    • pp.254-260
    • /
    • 2012
  • Purpose: Ongoing treatment and care, as well as initial stabilization, are required for trauma patients. With increasing number of sickest trauma patients and shortage of surgeons, the need for advanced practice nurse to provide and coordinate trauma care has been greater. The purpose of this study is to analyze the effect of hiring a trauma clinical nurse specialist and its influence on the treatment of trauma patients. Methods: Based on the employment of the clinical nurse specialist in December 2010, the patients were divided into two groups: patients admitted from January 1, 2010 to November 30, 2010 and patients admitted from December 1, 2010 to December 31, 2011. Retrospectively, data were collected using electronic medical records. The general characteristics, clinical courses, and ICU re-admission rates, collaboration (transfers to other departments and collaborative surgery) were compared. Results: To have a clinical nurse specialist on the trauma team resulted in a statistically significant reductions in the length of general ward hospital stay (p<0.05), the ICU re-admission rate, (p<0.03), the lead-time before transfer to other departments (p<0.05). Conclusion: The clinical nurse specialist, as a professional practitioner, improved the quality of treatment through early detection and management of problems. In addition, as a coordinator, the clinical nurse specialist maintained a cooperative relationship with multi-disciplinary medical personnel. The trauma clinical nurse specialist contributed to the treatment of trauma patients positively through a decrease in ICU re-admission rate and length of hospital stay.

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

A Biomechanical Comparison among Three Surgical Methods in Bilateral Subaxial Cervical Facet Dislocation

  • Byun, Jae-Sung;Kim, Sung-Min;Choi, Sun-Kil;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권2호
    • /
    • pp.89-95
    • /
    • 2005
  • Objective: The biomechanical stabilities between the anterior plate fixation after anterior discectomy and fusion (ACDFP) and the posterior transpedicular fixation after ACDF(ACDFTP) have not been compared using human cadaver in bilateral cervical facet dislocation. The purpose of this study is to compare the stability of ACDFP, a posterior wiring procedure after ACDFP(ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation. Methods: Ten human spines (C3-T1) were tested in the following sequence: the intact state, after ACDFP(Group 1), ACDFPW(Group 2), and ACDFTP(Group 3). Intervertebral motions were measured by a video-based motion capture system. The range of motion(ROM) and neutral zone(NZ) were compared for each loading mode to a maximum of 2.0Nm. Results: ROMs for Group 1 were below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation without significances. Group 2 produced additional stability in axial rotation of ROM and in flexion of NZ than Group 1 with significance. Group 3 provided better stability than Group 1 in bending and axial rotation, and better stability than Group 2 in bending of both ROM and NZ. There was no significant difference in extension modes for the three Groups. Conclusion: ACDFTP(Group 3) demonstrates the most effective stabilization followed by ACDFPW(Group 2), and ACDFP(Group 1). ACDFP provides sufficient strength in most loading modes, ACDFP can provide an effective stabilization for bilateral cervical facet dislocation with a brace.