• Title/Summary/Keyword: Surgical stability

Search Result 267, Processing Time 0.025 seconds

Use of Bovine-derived bone mineral (Bio-Oss Collagen$^{(R)}$) in surgical treatment of peri-implantitis: A case report (임상가를 위한 특집 3 - Peri-implantitis의 regeneration therapy 증례 보고)

  • Cho, Young Jae
    • The Journal of the Korean dental association
    • /
    • v.51 no.12
    • /
    • pp.650-657
    • /
    • 2013
  • The aim of this study was to achieve healing of Peri-implantitis defects and hard tissue augmentation using a bovine-derived bone mineral on the defect site. Two patients were treated with the surgical approach. With a full muco-periosteal flap elevation, the implant surfaces were exposed and granulation tissue removed around the implant and between the threads. Each surface of the contaminated implant was prepared with the air-abrasive device(PerioFlow$^{(R)}$) for decontamination. Bovine-derived bone mineral(Bio-Oss collagen$^{(R)}$) was then used to fill the defects and muco-periosteal flaps sutured to achieve transmucosal healing. Radiographs and clinical photographs were taken before and after 6 months of healing and an estimate of bone fill was assessed. Within the limits of the present case report, a surgical approach in treatment of peri-implantitis defects using a collagen form of bovine bone mineral was visited. Although limited, the two cases showed the stability and biocompatibility of a bovine-derived bone mineral and effectiveness of air-abrasive device(PerioFlow$^{(R)}$) as a decontamination method.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Arthroscopic Revision ACL Reconstruction (전방십자인대 재재건술)

  • Ahn Jin-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.20-27
    • /
    • 2003
  • It is reported that approximately 100,000 anteior cruciate ligament (ACL) reconstructions are performed in the United States each year. Recurrent instability because of graft failure is estimated to occur in from 0.7$\%$ to 8$\%$ of reconstruction. Recently revision ACL reconstruction is likely to become more common as the number of primary reconstructions continues to increase. Arthroscopic revision ACL surgery with adequate graft for failed ACL reconstruction was successful in objectively and subjectively improving stability. However, considering the most common causes of failure after ACL reconstruction were errors in surgical technique, it is important that the primary ACL reconstruction should be performed with correct surgical technique. Therefore author reviewed the causes of failure of reconstruction to prevent the failure of reconstruction and described the surgical technique of revision ACL reconstruction.

  • PDF

EVALUATION OF THE AVAILABILITY OF SURGICAL TREATMENT OBJECTIVE(STO) USING SUBMENTOVERTEX(SMV) VIEW (이하두정 방사선 사진을 이용한 악교정수술 계획의 유용성에 대한 평가)

  • Kim, Bum-Soo;Kim, Jong-Wan;Kim, Young-Kyun;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.324-328
    • /
    • 2009
  • Submentovertex(SMV) projection shows the base of skull, positions of mandibular condyle and zygomatic arches. We would like to investigate how to use SMV and evaluate its availability for the construction of the plan for orthognathic surgery of mandible prognathism and asymmetry. Preoperative Surgical Treatment Objective(STO) using SMV was performed to 12 patients, who visited to Seoul National University Bundang Hospital with chief complaints like mandible prognathism or asymmetry from Dec 2007 to Feb 2009. Surgical splint was made of stone model repositioned according to STO using SMV. We estimate the change in skeletal midline and the stability of occlusion through superposition between preoperative and postoperative SMV. It was effective on the amount of mandible movement and the correction of mandibular asymmetry, while the facial asymmetry involved with maxilla was excluded. It was concluded that STO using SMV is available and predictable method for not only the setback of prognathic mandible but also the correction of mandible asymmetry accurately.

Open Intramedullary Nail with Tension Band Sutures on Proximal Humeral Fracture (상완골 근위부 골절에 시행한 긴장 대 봉합을 동반한 관혈적 골수강내 고정술)

  • Park, Jin-Young;An, Jin-Woo;Lee, Sung-Churl
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.149-160
    • /
    • 2003
  • Purpose: to determine the results after open intramedullary nailing and tension band suture technique in proximal humerus fracture for improving the stability and decreasing the complications. Materials and Method: Authors reviewed 27 patients treated by open intramedullary nailing and tension band suture technique. Mean follow-up period was 39 months (24-59months). Surgical neck fracture were 6 cases, surgical neck fracture with shaft fracture were 3 cases, three part fracture with greater tuberosity fracture were 17 cases, four part fracture was 1 case and fracture and dislocation were 2 cases Results: We got the bony union in 26 cases. Average pain scale was 1 point (0-6), Neer score was 86 point(45-99) and ASES score was 85 point(40-100). We separate all cases in two groups based on age (65 years), L-spine t-score (-2.5) and Neer classification (2 and 3 part). There is no significance in pain scale, Neer score and ASES score between each group. Conclusion: As a method of surgical treatment on severe proximal humeral fractures, we recommend intramedullary nailing and tension band suture technique and it may have particular advantages in early exercise and satisfactory functional outcome.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Shoulder Injuries in Throwing Athletes (Throwing athletes에서 어깨 관절의 손상)

  • Lee Kwang-Won
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.119-126
    • /
    • 2003
  • The shoulder is a complex joint and, by virtue of having a large range of motion, is inherently unstable, relying on the surrounding soft tissue structures for stability. The bony joint consists of the glenoid, acromion, and humoral head, while the soft tissues include the glenoid labrum, the glenohumeral ligaments. and coracoacromial ligament as well as the muscles of the rotator cuff, the long head of the biceps, and the scapulothoracic muscles. Dysfunction in any one of these components can cause shoulder problems. The throwing motion involves a series of phases that stress to their limits the dynamic and static restraints of the glenohumeral and scapulothoracic joints. . Therefore, maintaining a balance of proper biomechanical forces is essential to avoiding shoulder injuries in throwing athletes. Over the last decade, signficant advances have been made in the study and understanding of the shoulder mechanics, and pathophysiology of injury. Additionally, advances in surgical techniques, particularly arthroscopy , have aided in the diagnosis of and the developement of less invasive surgical treatments for injuries that do not respond to nonoperative measures. In this article, we reviewed the pathophysiology of injuries , diagnostic techniques, and surgical management of shoulder injuries in throwing athletes .

  • PDF

Surgical Treatment of the Acute Acromioclavicular Joint Dislocation with a LIGASTIC Artificial Ligament (LIGASTIC 인공인대를 이용한 급성 견봉 쇄골 탈구의 수술적 치료)

  • Choi Sun-Jin;Kim Sang-Hyo;Park Han-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.135-140
    • /
    • 2005
  • Purpose: To find out the early results after surgical treatment of the acute acromioclavicular dislocation with LIGASTIC artificial ligament. Material and Method: 6 patients who were diagnosed as acute acomioclavicular joint dislocation and treated with LIGASTIC artifical ligament through March 2005 to July 2005. The radiologic and clinical results using Imatani evaluation system were analyzed. Results: By clinical evaluation, 4 cases(67%) were excellent and 2 cases(33%) were good. By radiologic evaluation, 3 cases(50%) were excellent and 3 cases(50%) were good. All cases showed satisfactory results. Till the final follow up, there were no complication. Conclusion: Surgical treatment of the acute acromioclavicular dislocation with LIGASTIC articifial ligament is simple, but provides enough stability for early postoperative rehabilitation, decreases arthritis of acomioclavicular joint and there is no burden of removal of the fixture, so it is thought as a very effective surgery.

Real time control special quality research for $CO_2$ laser's output change rate stability for accumulation style surgical operation rehabilitation of ventriculus that use Photosensor (Photosensor를 이용한 재활 치료형을 위한 $CO_2$ laser 의 출력변동율 안정을 위한 실시간 제어특성 연구)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1015-1016
    • /
    • 2006
  • The important parameters deciding the fluctuation of Accumulation style surgical operation of ventriculus laser beam are smoothing capacitor, frequency and he characteristics of laser resonator. In this thesis, we control the fluctuation of medical $CO_2C$ laser in realtime by changing Duty-Ratio of IGBT and switching frequency with fixed the smoothing capacitor to improve the fluctuation of laser beam. We detect the light on laser resonator using a CdS photo sensor to improve ripple factor of laser beam and feedback fluctuated signals refined by a band pass filter into the control circuit to stabilize fluctuation actively. There is much to be desired in the realtime controlling technique of the light on Accumulation style surgical operation of ventriculus laser discharge tube in electrical signal. We propose switching control technique with microprocessor and photo sensing technique by controlling switch devices optimum operation and feedback signals detected by a photo sensor into the laser power supply in order to improve ripple factor of the $CO_2$ laser beam.

  • PDF

Mandibular midline osteotomy for correction of bimaxillary transverse discrepancy: a technical note

  • Mrunalini Ramanathan;Rie Sonoyama-Osako;Yukiho Shimamura;Taro Okui;Takahiro Kanno
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.3
    • /
    • pp.107-113
    • /
    • 2023
  • Bimaxillary transverse width discrepancies are commonly encountered among patients with dentofacial deformities. Skeletal discrepancies should be diagnosed and managed appropriately with possible surgical corrections. Transverse width deficiencies can present in varieties of combinations involving the maxilla and mandible. We observed that in a significant proportion of cases, the maxilla is normal, and the mandible showed deficiency in the transverse dimension after pre-surgical orthodontics. We designed novel osteotomy techniques to enhance mandibular transverse width correction, as well as simultaneous genioplasty. Chin repositioning along any plane is applicable concomitant with mandibular midline arch widening. When there is a requirement for larger widening, gonial angle reduction may be necessary. This technical note focuses on key points in management of patients with transversely deficient mandible and the factors affecting the outcome and stability. Further research on the maximum amount of stable widening will be conducted. We believe that developing evidence-based additional modifications to existing conventional surgical procedures can aid precise correction of complex dentofacial deformities.