• Title/Summary/Keyword: Surgical device

Search Result 271, Processing Time 0.034 seconds

The flip-flap puzzle flap: Another recycling option

  • Gandolfi, Silvia;Carloni, Raphael;Gilleron, Matthieu;Bonmarchand, Albane;Auquit-Auckbur, Isabelle
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.176-180
    • /
    • 2019
  • Post-traumatic soft tissue defects sometimes require sequential flap coverage to achieve complete healing. In the era of propeller flaps, which were developed to reduce donor site morbidity, Feng et al. introduced the concept of the free-style puzzle flap, in which a previously harvested flap becomes its own donor site by recycling the perforator. However, when a perforator cannot be found with a Doppler device, we suggest performing a new type of flap, the flip-flap puzzle flap, which combines two concepts: the free-style puzzle flap and the flip-flap flap described by Voche et al. in the 1990s. We present the cases of three patients who achieved complete healing through this procedure.

Remote Reading of Surgical Monitor's Physiological Readings: An Image Processing Approach

  • Weerathunga, Haritha;Vidanage, Kaneeka
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.7
    • /
    • pp.308-314
    • /
    • 2022
  • As a result of the global effect of infectious diseases like COVID-19, remote patient monitoring has become a vital need. Surgical ICU monitors are attached around the clock for patients in critical care. Most ICU monitor systems, on the other hand, lack an output port for transferring data to an auxiliary device for post-processing. Similarly, strapping a slew of wearables to a patient for remote monitoring creates a great deal of discomfort and limits the patient's mobility. Hence, an unique remote monitoring technique for the ICU monitor's physiologically vital readings has been presented, recognizing this need as a research gap. This mechanism has been put to the test in a variety of modes, yielding an overall accuracy of close to 90%.

Laser Application and Nursing in the Field of Gynecology

  • Kim, Kyunghee
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.201-206
    • /
    • 2021
  • The recent development of new surgical techniques using lasers has increased the opportunities for open surgery involving minimal manipulation and faster and more accurate removal of lesions. The increasing use of laser technology requires nurses to play an extensive role. As assistants, nurses play an important role in maintaining the efficacy and safety of the laser device. In addition, they are also responsible for providing pre-and post-operative care to patients. Therefore, nurses should be aware of how to proceed with operative laser treatment for all surgical procedures and the steps for maintaining safety prior to, during, and after laser treatment. This review provides in-depth knowledge for nurses undertaking continuing education on lasers and patient care in the field of gynecology.

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

The Effect of Forward Head Posture Correctional Device During Computer Work (컴퓨터 작업 시 전방머리자세 교정장치의 효과)

  • Yi, Chung-Hwi;Yoo, Won-Gyu;Kim, Min-Hee
    • Physical Therapy Korea
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Work-related musculoskeletal disorder has been associated with long hours of computer work and prolonged periods of static posture. In clinical settings, postural correction is a common treatment approach for individuals with neck, shoulder, and back pain. This study was designed to identify the effect of Forward Head Posture Correctional Device during computer work. Twelve healthy adults (mean age, 27.4 yrs; mean height, 165.0cm mean weight, 65.8 kg) participated in the study. They had no medical history of neurological or surgical problems with their upper extremity. The subjects were asked to perform Head Forward Posture under the guidance of physical therapists and the measured angles were analyzed using a 3-D motion analysis system. Markers were placed on the C7 spinous process, tragus of the ear and forward head angle was between the line from the tragus to the C7 line and the Y-axis at the C7. The statistical significance of difference between, "without" and "with" correctional device was tested by paired t-test. A level of significance was set at ${\alpha}$=.05. In comparison of the computer work between "without" and "with" correctional device, Forward Head Angle was showed significant difference (p<.05). In conclusion, the range of Forward Head Angle was significantly decreased during computer work with the correctional device. Further research is needed to understand the nature of motor control problems in deep muscles in patients with neck, shoulder, and back pain.

  • PDF

A Theoretical Study and Implementation of Spinal Traction System (척추견인 시스템의 인체 역학적 견인력에 대한 이론적 고찰 및 구현에 관한 연구)

  • Chang, Hojong;Lee, Song Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.19-25
    • /
    • 2014
  • According to recent data more than 80% of people suffer from back pain, due to an aging and a poor posture, at least once in their life time, and 7~10% of them have chronic spine illness. Researchers over the years have studied on various spinal traction devices that utilize the force of traction, and have also reported clinical test results. However, most existing devices are too complicated and too expensive. In order to solve these problems, we have developed a new device in which the frame moves up and down and at the same time tilting angle of the frame is adjusted. We have analyzed the forces applied on the body as a function of tilting angle. And the result shows that the new device has achieved the force of traction, which is known to be effective for spinal rehabilitation.

Pelvic Actinomycosis Mimicking Malignancy of the Uterus: a Case Report

  • Shin, Dahye;Hwang, Jiyoung;Hong, Seong Sook;Lee, Eun Ji;Kim, Yon Hee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.136-141
    • /
    • 2019
  • Pelvic actinomycosis is an uncommon infectious disease. It induces a chronic, suppurative illness characterized by an infiltrative and granulomatous response and, thus, the clinical and radiologic findings may mimic other inflammatory and neoplastic conditions. A 56-year-old female with a long-standing intrauterine device was diagnosed with pelvic actinomycosis manifesting as a large uterine mass with locally infiltrative spread into surrounding tissue that mimicked uterine malignancy. Actinomyces israelii infection was confirmed with a surgical specimen, and the patient was treated with antibiotic medication. Pelvic actinomycosis must be included in the differential diagnoses of patients with an infiltrative pelvic mass extending across tissue planes or in patients with findings of multiple microabscesses, particularly in a patient with an intrauterine device, even the lesion primarily involves the uterus.

Levoatrial Cardinal Vein: Occluder Embolization and Complication Management

  • Mercan, Ilker;Akyuz, Muhammet;Guven, Baris;Isik, Onur
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.214-217
    • /
    • 2021
  • In rare cases, levoatrial cardinal vein may occur as an isolated condition without additional congenital anomalies. Depending on the direction and flow of the shunt, this pathology may produce symptoms; alternatively, it may be asymptomatic, as in the case presented in this study. In asymptomatic cases, complications, such as paradoxical embolism and brain abscess, can arise later. In the 11-year-old patient whose case is presented here, the levoatrial cardinal vein was asymptomatic and incidentally detected. The percutaneous closure method was applied first. However, by 16 hours after the procedure, the occluder device had embolized to the iliac artery. Emergency surgery was performed; first, the occluder device was removed, and levoatrial cardinal vein ligation was then performed via a mini-thoracotomy. The symptoms, diagnosis, and treatment modalities of isolated levoatrial cardinal vein are discussed in the context of this case described herein.

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.