• Title/Summary/Keyword: Surgical device

Search Result 274, Processing Time 0.026 seconds

Fabrication of implant-associated obturator after extraction of abutment teeth: a case report (지대치 발거 후 임플란트 연관 상악 폐색장치 제작 증례보고)

  • Ki-Yeol Jang;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.229-236
    • /
    • 2023
  • Maxillary bone defects may follow surgical treatment of benign and malignant tumors, trauma, and infection. Palatal defects often lead to problems with swallowing and pronunciation from the leakage of air into the nasal cavity and sinus. Obturators have been commonly used to solve these problems, but long-term use of the device may cause irritation of the oral mucosa or damage to the abutment teeth. Utilizing implants in the edentulous area for the fabrication of the obturators has gained attention. This case report describes a patient, who had undergone partial resection of the maxilla due to adenocarcinoma, in need of a new obturator after losing abutment teeth after long-term use of the previous obturator. Implants were placed in strategic locations, and an implant-retained maxillary obturator was fabricated, showing satisfactory results in the rehabilitation of multiple aspects, including palatal defect, masticatory function, swallowing, pronunciation, and aesthetics.

Local Ablation for Hepatocellular Carcinoma: 2024 Expert Consensus-Based Practical Recommendations of the Korean Liver Cancer Association

  • Seungchul Han;Pil Soo Sung;Soo Young Park;Jin Woong Kim;Hyun Pyo Hong;Jung-Hee Yoon;Dong Jin Chung;Joon Ho Kwon;Sanghyeok Lim;Jae Hyun Kim;Seung Kak Shin;Tae Hyung Kim;Dong Ho Lee;Jong Young Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.9
    • /
    • pp.773-787
    • /
    • 2024
  • Local ablation for hepatocellular carcinoma (HCC), a non-surgical option that directly targets and destroys tumor cells, has advanced significantly since the 1990s. Therapies with different energy sources, such as radiofrequency ablation, microwave ablation, and cryoablation, employ different mechanisms to induce tumor necrosis. The precision, safety, and effectiveness of these therapies have increased with advances in guiding technologies and device improvements. Consequently, local ablation has become the first-line treatment for early-stage HCC. The lack of organized evidence and expert opinions regarding patient selection, pre-procedure preparation, procedural methods, swift post-treatment evaluation, and follow-up has resulted in clinicians following varied practices. Therefore, an expert consensus-based practical recommendation for local ablation was developed by a group of experts in radiology and hepatology from the Research Committee of the Korean Liver Cancer Association in collaboration with the Korean Society of Image-guided Tumor Ablation to provide useful information and guidance for performing local ablation and for the pre- and post-treatment management of patients.

The In-hospital Clinical Outcomes of Extracorporeal Life Support after Adult Cardiovascular Surgery (성인 심혈관 수술 후 시행한 체외순환보조의 조기 임상결과)

  • Yie, Kil-Soo;Na, Chan-Young;Oh, Sam-Sae;Kim, Jae-Hyun;Ryu, Se-Min;Park, Sung-Min;Cho, Seong-Joon
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.464-472
    • /
    • 2009
  • Background: We analyzed the clinical results and the factors for survival of patients who underwent extracorporeal life support system after adult cardiovascular surgery. Material and Method: We retrospectively reviewed the medical record of 44 patients (1.6% of the total adult cardiovascular surgical cases) who underwent the use of a ventricular assisted device or extracorporeal membrane oxygenation from January 2002 to August 2008. There were 32 (72.7%) males and their mean age was 61.7$\pm$14.9(range: 20$\sim$73) years old. The mean duration of extracorporeal life support system was 5.3$\pm$3.0 (range: 1$\sim$12) days. Result: Of these 44 patients, 24 (54.5%) patients were successfully weaned from the extracorporeal device. Eighteen (40.9%) survivors were able to be discharged from the hospital. Complications were noted in 38 patients (86.4%). An emergency operation, no usage of a concomitant intraaortic balloon pump and major complications during use of the extra corporeal life support system such as bleeding, flow instability and renal failure were identified as significant risk factors for poor survival on univariated analysis. Owing to educational support and a continuous renal replacement therapy system, the clinical outcomes of these patients have improved since 2006. On multivariated analysis, renal failure and bleeding during extracorporeal life support were significant risk factors for poor survival. Conclusion: Although using. extracorporeal life support systems after adult cardiovascular surgery revealed acceptable clinical results, determining the optimal treatment strategy and further well designed larger studies are needed to improve the survival rate of patients who undergo extracorporeal life support after adult cardiovascular surgery.

Arthroscopic Double-Bundle Reconstruction of Anterior Cruciate Ligament (관절경을 이용한 전방 십자 인대의 이중 다발 재건술)

  • Jung, Young-Bok;Park, Se-Jin;Jung, Ho-Joong;Yoo, Jae-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Purposes: The purpose of this study was to report surgical technique of double bundle anterior cruciate ligament(ACL) reconstruction and to compare the short-term clinical results between arthroscopic single-bundle and double-bundle ACL reconstruction. Materials and Methods: From May 2005 to May 2006, ninety-eight patients were underwent ACL reconstruction. We designed prospective study with sixty-one patients who were revealed isolated ACL injury. We serially checked clinical and radiologic data preoperatively and postoperatively. We compared single-bundle with double-bundle ACL reconstruction patients with preoperative datas and postoperatively 1-year data. There were 30 single bundle reconstruction and 31 double bundle reconstruction. Stability was assessed objectively by anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer. The clinical results were assessed by IKDC(International Knee Documentation Committee) and OAK(Orthopadische Arbeitsgruppe Knie) scores. Also, we evaluated postoperative thigh circumference and range of motion. All of operations were done by only one surgeon. Results: At single-bundle reconstruction group, preoperative AP instability which was checked by $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer was $7.9{\pm}3.3$ and $7.4{\pm}2.0$, respectively. At double-bundle reconstruction group, it was $8.3{\pm}3.5$ and $7.9{\pm}3.2$, respectively. Residual AP laxity checked at 1 year after operation was $1.9{\pm}1.2$ and $2.2{\pm}1.6$ in single-bundle reconstruction group, and $1.1{\pm}0.9$ and $1.0{\pm}1.0$ in double-bundle reconstruction group. So, double-bundle reconstruction had better results in both anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer, and there were significant differences in statistics. But, clinical results such as IKDC(International Knee Documentation Committee) scores, OAK(Orthopadische Arbeitsgruppe Knie) scores, thigh circumference and range of motion had no significant difference between two groups. Conclusions: On the basis of stability, the side-to-side anterior laxity of double-bundle ACL reconstruction was significantly better than that of single-bundle reconstruction, although there were no significant differences in the other clinical measures among them.

  • PDF

Postcardiotomy Ventricular Support with Biomedicus Pump (Biomedicus pump를 이용한 개심술후 심실보조)

  • Kim, Won-Gon;Lee, Chang-Ha;Kim, Ki-Bong;Ahn, Hyuk;Rho, Ryang-Joon
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1218-1222
    • /
    • 1996
  • The reported incidence of postcardiotomy cardiogenic shock not responding to conventional therapy is still 0.1 to 0.8%. For this group of patients, more aggressive form of circulatory support must be employed. Centrifugal pumps are a ventricular assist device most commonly used on this purpose, due to low cost and easy availability. Currently, however, clinical experience of centrifugal pumps as a ventricular assist device is rarely reported in Korea. From January 1992 to January 1996, 2986 patients underwent cardiac operations on cardiopulmonary bypass at Seoul National University Hospital. Refractory postcardiotomy cardiac failure requring ventricular support with a Biomedicus centrifugal pump developed in ten of these patients. There were eight men and two women, ranged in age from nine years to 77 years with a mean of 50$\pm$20 years. The primary surgical procedures consisted of isolated coronary revascularization in four patients, combined coronary revascularization and aortic valve replacement in two, aortic dissection repair in two, pulmonary embolectomy in one, and heart transplantation in one. Of the ten patients, five had left ventricular assistance, one had right ventricular assistance, and four had biventricular assistance. Duration of ventricular assistance ranged from 24 to 175 hours, with a mean of 76$\pm$51 hours. Seven patients were weaned from ventricular assistance, and four of them discharged. The causes of death for nonsurvivors were progressive cardiac failure in two patients and multiorgan failure, intractable ventricular fibrillation, irreversible brain injury, and mechanical problem, respectively, in the other four. Survival was not predicted by time on cardiopulmonary bypass, aortic cross-clamp time, or duration of ventricular support. Major complications included bleeding(7), renal failure(6), infection(3) and neurologic complication(2). These results indicate that a centrifugal pump can provide reasonably satisfactory short-term circulatory support.

  • PDF

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

Postoperative Complications after Preoperative Chemoradiotherapy Combined with Hyperthermia in Locally Advanced Rectal Cancer (국소 진행성 직장암의 수술전 동시 화학방사선치료와 온열치료병합시 수술후 부작용)

  • Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • We investigated whether regional hyperthermia (HT) increased post-surgical complications in patients with locally advanced rectal cancer treated with preoperative concurrent chemoradiotherapy (CCRT). Between 1996 and 2007, 205 patients treated with preoperative CCRT and curative surgery were evaluable for the analysis of acute and late toxicities. A total dose of 39.6 Gy or 45 Gy was delivered concurrently with one or two cycles of chemotherapy (5-fluorouracil, leucovorin). Eighty-eight patients received regional HT twice a week using an 8-MHz radiofrequency capacitive heating device. Surgery was performed 4~6 weeks after the completion of preoperative CCRT. The median age was 59 years (range, 18~83) and the median follow-up period was 61months (range, 2~191). The 5-year overall survival and complication-free survival rate of all patients was 77.4% and 73.7%, respectively. Early leakage, delayed leakage, anastomotic stricture, fistula, and small bowel obstruction occurred in 1.0%, 2.9%, 1.5%, 5.9%, and 17.1%, respectively. HT did not increase all kinds of complications. The 5-year complication-free survival rate was 71.8% in the non-HT group and 76.3% in the HT group (p=0.293). Regional HT did not increase postoperative complications in patients with locally advanced rectal cancer treated with preoperative CCRT followed by curative surgery.

Influence of Heat Treatment Conditions on Temperature Control Parameter ((t1) for Shape Memory Alloy (SMA) Actuator in Nucleoplasty (수핵성형술용 형상기억합금(SMA) 액추에이터 와이어의 열처리 조건 변화가 온도제어 파라미터(t1)에 미치는 영향)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Yang, Young-Gyu;Kim, Tae-Young;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.619-628
    • /
    • 2010
  • Shape Memory Alloy (SMA) has recently received attention in developing implantable surgical equipments and it is expected to lead the future medical device market by adequately imitating surgeons' flexible and delicate hand movement. However, SMA actuators have not been used widely because of their nonlinear behavior called hysteresis, which makes their control difficult. Hence, we propose a parameter, $t_1$, which is necessary for temperature control, by analyzing the open-loop step response between current and temperature and by comparing it with the values of linear differential equations. $t_1$ is a pole of the transfer function in the invariant linear model in which the input and output are current and temperature, respectively; hence, $t_1$ is found to be related to the state variable used for temperature control. When considering the parameter under heat treatment conditions, $T_{max}$ was found to assume the lowest value, and $t_1$ was irrelevant to the heat treatment.

Ultrasound-guided Core Needle Biopsy in Diagnosis of Soft Tissue Masses (연부조직 종물의 진단에서 초음파 유도하 중심부 침생검)

  • Kim, Jeung-Il;Youn, Myung-Soo;Cheon, Sang-Jin;Choi, Gyung-Un;Lee, Tae-Hong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.113-119
    • /
    • 2004
  • Purpose: To determine the utility of sonographically guided percutaneous core needle biopsy to diagnose musculoskeletal soft tissue masses. Methods: A prospective study was performed in 55 patients referred for image-guided needle biopsy of primary or recurrent soft tissue masses and bone lesion or suspected solitary metastasis with extraosseous masses. Tissue samples were obtained with a 14-gauge or 18-gauge cutting needle coupled to an automated biopsy device under local anesthesia and sonographic guidance. Statistical analysis was based on 49 biopsies confirmed by successful clinical treatment (11 cases) or surgical resection (38 cases). Results: An accurate diagnosis was obtained in 47 (97%) of 49 biopsies; sensitivity was 95%, and specificity was 100%. The method did not yield sufficient tissue to establish a diagnosis in 6 cases. Considering all 55 biopsies, high-quality specimens were obtained in 87%. There were no serious complications. Conclusions: Sonographically guided core needle biopsy is accurate and safe, in soft tissue masses and bone tumors with extraosseous masses in the appendicular skeleton. In such patients, the sonographically guided procedure is the most prompt and effective method for obtaining tissue samples.

  • PDF

Efficacy of minimal invasive cardiac output and ScVO2 monitoring during controlled hypotension for double-jaw surgery

  • Kim, Seokkon;Song, Jaegyok;Ji, Sungmi;Kwon, Min A;Nam, Dajeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.6
    • /
    • pp.353-360
    • /
    • 2019
  • Background: Controlled hypotension (CH) provides a better surgical environment and reduces operative time. However, there are some risks related to organ hypoperfusion. The EV1000/FloTrac system can provide continuous cardiac output monitoring without the insertion of pulmonary arterial catheter. The present study investigated the efficacy of this device in double jaw surgery under CH. Methods: We retrospectively reviewed the medical records of patients who underwent double jaw surgery between 2010 and 2015. Patients were administered conventional general anesthesia with desflurane; CH was performed with remifentanil infusion and monitored with an invasive radial arterial pressure monitor or the EV1000/FloTrac system. We allocated the patients into two groups, namely an A-line group and an EV1000 group, according to the monitoring methods used, and the study variables were compared. Results: Eighty-five patients were reviewed. The A-line group reported a higher number of failed CH (P = 0.005). A significant correlation was found between preoperative hemoglobin and intraoperative packed red blood cell transfusion (r = 0.525; P < 0.001). In the EV1000 group, the mean arterial pressure (MAP) was significantly lower 2 h after CH (P = 0.014), and the cardiac index significantly decreased 1 h after CH (P = 0.001) and 2 h after CH (P = 0.007). Moreover, venous oxygen saturation (ScVO2) decreased significantly at both 1 h (P = 0.002) and 2 h after CH (P = 0.029); however, these values were within normal limits. Conclusion: The EV1000 group reported a lower failure rate of CH than the A-line group. However, EV1000/FloTrac monitoring did not present with any specific advantage over the conventional arterial line monitoring when CH was performed with the same protocol and same mean blood pressure. Preoperative anemia treatment will be helpful to decrease intraoperative transfusion. Furthermore, ScVO2 monitoring did not present with sufficient benefits over the risk and cost.