• Title/Summary/Keyword: Surgical device

Search Result 271, Processing Time 0.03 seconds

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

Transcatheter Embolotherapy of Giant Pulmonary Arteriovenous Malformation Using Amplatzer® Vascular Plug (Amplatzer® 혈관폐색장치를 이용한 거대 폐동정맥기형 색전술 1예)

  • Jung, Ki Hwan;Lee, Seung Hwa;Shin, Chol;Kim, Je Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.52-58
    • /
    • 2009
  • Pulmonary arteriovenous malformation (PAVM) is a rare pulmonary vascular anomaly due to an abnormal communication between the pulmonary artery and vein. The most common presenting symptom is a dyspnea on exertion related to this right-to-left shunt. If left untreated, PAVM has been known to result in serious complications. Incomplete pulmonary capillary network can be the cause of cerebral abscesses and other noninfectious neurological complications, such as stroke and transient ischemic attacks due to paradoxic embolism Transcatheter embolotherapy, using coils or balloons, has replaced surgical resection as the treatment of choice for PAVM. However, the risk of device embolization has limited the use of coil embolotherapy, while the size of PAVM is huge. Recently, Amplatzer$^{(R)}$ Vascular Plug has been proposed as an alternative endovascular occlusion device for arteriovenous malformation. We report a case of 81-year-old male patient with a giant PAVM, which was successfully treated by transcatheter embolotherapy using the Amplatzer$^{(R)}$ Vascular Plug.

Treatment of large sized cystic lesion of the jaws with specific appliance for decompression:cases report (악골 내 거대 낭종성 병소의 감압술을 위해 고안된 장치를 이용한 치험례: 증례보고)

  • Jang, Chang-Su;Kim, Ju-Won;Yang, Seung-Bin;Yim, Jin-Hyuk;Kim, Jwa-Young;Yang, Byoung-Eun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.133-136
    • /
    • 2011
  • Cystic lesions on the jaws with expansion can invade the adjacent anatomical structure, infiltrate and expand the jaws, cause facial deformity, etc. There is great potential for pathologic fractures after cyst enucleation, and damage to the major structures like the nerve, artery. For these reasons, marsupialization and decompression are commonly used to reduce the cystic size. In 1947, Thomas first mentioned decompression that reduces the osmotic pressure in a cyst by making a hole in the cyst and insert a drain. In our cases, a large sized cystic lesion was treated with a specific device made from an orthodontic band and spinal needle. This device is easy and effective for applications and self irrigation.

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

New economical and simple device for intraoperative expansion on small and medium sized soft tissue defects

  • Lee, Jun Won;Park, Seong Hoon;Lee, Seong Joo;Kim, Seong Hwan;Jeong, Hii Sun;Suh, In Suck
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.235-239
    • /
    • 2018
  • Intraoperative expansion has been used to cover small to large defects without disadvantages of the conventional tissue expanders. Various materials, for example, expanders and Foley catheters are being used. We introduce a new, convenient and economical device immediately available in the operating room, according to the defect size for intraoperative expansion, with latex gloves or balloons. The retrospective study was done with 20 patients who presented with skin and soft tissue defects. During the operation, expansion was done with latex gloves or balloons inflated with saline through an intravenous line and a three-way stopcock. After the inflation, the glove was removed and skin was covered with expanded tissue. A careful decision was made regarding the inflation volume and placement of the expander according to the defect size. There were no postoperative complications. The skin contracture and tension was minimal with a texture similar to the adjacent tissue. The new intraoperative expansion devices with latex gloves and balloons were cheap and made easily right in the operation room. The reconstruction of small to large sized skin defects can be done successfully, functionally and aesthetically without using expensive commercial materials.

Use of an Optical Scanning Device to Monitor the Progress of Noninvasive Treatments for Chest Wall Deformity: A Pilot Study

  • Kelly, Robert E. Jr.;Obermeyer, Robert J.;Kuhn, M. Ann;Frantz, Frazier W.;Obeid, Mohammad F.;Kidane, Nahom;McKenzie, Frederic D.
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.390-394
    • /
    • 2018
  • Background: The nonsurgical treatment of chest wall deformity by a vacuum bell or external brace is gradual, with correction taking place over months. Monitoring the progress of nonsurgical treatment of chest wall deformity has relied on the ancient methods of measuring the depth of the excavatum and the protrusion of the carinatum. Patients, who are often adolescent, may become discouraged and abandon treatment. Methods: Optical scanning was utilized before and after the intervention to assess the effectiveness of treatment. The device measured the change in chest shape at each visit. In this pilot study, patients were included if they were willing to undergo scanning before and after treatment. Both surgical and nonsurgical treatment results were assessed. Results: Scanning was successful in 7 patients. Optical scanning allowed a visually clear, precise assessment of treatment, whether by operation, vacuum bell (for pectus excavatum), or external compression brace (for pectus carinatum). Millimeter-scale differences were identified and presented graphically to patients and families. Conclusion: Optical scanning with the digital subtraction of images obtained months apart allows a comparison of chest shape before and after treatment. For nonsurgical, gradual methods, this allows the patient to more easily appreciate progress. We speculate that this will increase adherence to these methods in adolescent patients.

Design and manufacture of eyeball protrusion measuring device using white light scanning interferometer (백색광 간섭계를 이용한 안구 돌출 측정 장치 설계 및 제작)

  • Chang, Jung-soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2019
  • The relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure eyeball protrusion values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In this paper, we designed and fabricated a protrusion measuring device using a white light interferometer and measured the protrusion of the human eye and found that the precision and repeatability were significantly higher than the manual measurement method.

Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography for patients with Roux-en-Y gastric bypass anatomy: technical overview

  • Hirokazu Honda;Jeffrey D. Mosko;Ryosuke Kobayashi;Andras Fecso;Bong Sik Kim;Schoeman Scott;Gary R. May
    • Clinical Endoscopy
    • /
    • v.55 no.6
    • /
    • pp.736-741
    • /
    • 2022
  • Endoscopic retrograde cholangiopancreatography (ERCP) in patients with Roux-en-Y gastric bypass anatomy is a well-documented challenge. Traditionally, this problem has been overcome with adjunctive techniques, such as device-assisted ERCP, including double-balloon or single-balloon enteroscopy and laparoscopy-assisted transgastric ERCP. Endoscopic ultrasound-directed transgastric ERCP (EDGE) is a novel technique that enables access to the ampulla using a duodenoscope without surgical intervention and has shown high clinical and technical success rates in recent studies. However, this approach is technically demanding, necessitating a thorough understanding of the gastrointestinal anatomy as well as high operator experience. In this review, we provide a technical overview of EDGE in parallel with our personal experience at our center and propose a simple algorithm to select patients for its appropriate application. In conjunction, the outcomes of EDGE compared with those of device-assisted and laparoscopy-assisted transgastric ERCP will be discussed.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser (피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

A Study on the MEG Imaging (MEG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.123-128
    • /
    • 2005
  • Magnetoencephalography (MEG) is the measurement of the magnetic fields produced by electrical activity in the brain, usually conducted externally, using extremely sensitive devices such as Superconducting Quantum Interference Device (SQUID). MEG needs complex and expensive measurement settings. Because the magnetic signals emitted by the brain are on the order of a few femtoteslas (1 fT = 10-15T), shielding from external magnetic signals, including the Earth's magnetic field, is necessary. An appropriate magnetically shielded room is very expensive, and constitutes the bulk of the expense of an MEG system. MEG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other brain activity measurement techniques such as electroencephalography (EEG), positron emission tomography (PET), single-photon emission computed tomography (SPECT) and functional magnetic resonance imaging (fMRI). MEG combines functional information from magnetic field recordings with structural information from MRI. The clinical uses of MEG are in detecting and localizing epileptic form spiking activity in patients with epilepsy, and in localizing eloquent cortex for surgical planning in patients with brain tumors. Magnetoencephalography may be used alone or together with electroencephalography, for the measurement of spontaneous or evoked activity, and for research or clinical purposes.

  • PDF