• 제목/요약/키워드: Surgery, method

검색결과 5,449건 처리시간 0.032초

Minimally Invasive Anterior Decompression Technique without Instrumented Fusion for Huge Ossification of the Posterior Longitudinal Ligament in the Thoracic Spine : Technical Note And Literature Review

  • Yu, Jae Won;Yun, Sang-O;Hsieh, Chang-Sheng;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.597-603
    • /
    • 2017
  • Objective : Several surgical methods have been reported for treatment of ossification of the posterior longitudinal ligament (OPLL) in the thoracic spine. Despite rapid innovation of instruments and techniques for spinal surgery, the postoperative outcomes are not always favorable. This article reports a minimally invasive anterior decompression technique without instrumented fusion, which was modified from the conventional procedure. The authors present 2 cases of huge beak-type OPLL. Patients underwent minimally invasive anterior decompression without fusion. This method created a space on the ventral side of the OPLL without violating global thoracic spinal stability. Via this space, the OPLL and anterior lateral side of the dural sac can be seen and manipulated directly. Then, total removal of the OPLL was accomplished. No orthosis was needed. In this article, we share our key technique and concepts for treatment of huge thoracic OPLL. Methods : Case 1. 51-year-old female was referred to our hospital with right lower limb radiating pain and paresis. Thoracic OPLL at T6-7 had been identified at our hospital, and conservative treatment had been tried without success. Case 2. This 54-year-old female with a 6-month history of progressive gait disturbance and bilateral lower extremity radiating pain (right>left) was admitted to our institute. She also had hypoesthesia in both lower legs. Her symptoms had been gradually progressing. Computed tomography scans showed massive OPLL at the T9-10 level. Magnetic resonance imaging of the thoracolumbar spine demonstrated ventral bony masses with severe anterior compression of the spinal cord at the same level. Results : We used this surgical method in 2 patients with a huge beaked-type OPLL in the thoracic level. Complete removal of the OPLL via anterior decompression without instrumented fusion was accomplished. The 1st case had no intraoperative or postoperative complications, and the 2nd case had 1 intraoperative complication (dural tear) and no postoperative complications. There were no residual symptoms of the lower extremities. Conclusion : This surgical technique allows the surgeon to safely and effectively perform minimally invasive anterior decompression without instrumented fusion via a transthoracic approach for thoracic OPLL. It can be applied at the mid and lower level of the thoracic spine and could become a standard procedure for treatment of huge beak-type thoracic OPLL.

부분 설절제술을 받은 환자에서의 연마면 인상 및 Direct Metal Laser Sintering 을 이용한 총의치 제작 증례 (Complete denture making in a patient of partial glossectomy using polished surface impression taking and direct metal laser sintering method: A case report)

  • 정연욱;이경제;김희중
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.350-355
    • /
    • 2019
  • 성공적인 총의치를 위해서는 유지, 안정, 지지 세가지 요소가 필수적으로 요구된다. 또한 심한 치조제의 흡수나 수술에 의한 반흔으로 인해 하악 설측변연 형성이 어려운 총의치 제작시에는 무교두 치아배열, 연마면 인상, 무게 보강 내부금속 삽입, 의치 접착 크림의 사용 등의 다양한 고려사항이 필요하다. 본 환자의 경우 심한 치주염으로 심하게 골흡수가 된 무치악 치조제를 가졌고, 또한 설암으로 인한 설절제술로 인해 연조직의 문제를 가진 환자이다. 부가적인 유지와 안정을 얻기 위해 연마면 인상과 내부 보강 금속구조물의 삽입 그리고 최소 가압 인상 등의 방법을 적용하여 보다 나은 임상적 결과를 나타내었다. 또한 원하는 3차원적 형태를 정확하게 부여하고 제작시 복잡한 기공과정을 줄인 금속 구조물을 제작하기 위해 최소 가압 인상 채득과 Direct metal laser sintering이 사용되었다.

스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구 (A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device)

  • 박준현;호예지;이예림;이덕희;최재순
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권5호
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

요엽후박나무 추출물의 입술 주름 개선에 대한 연구 (Effects of Magnolia Officinalis Bark Extract on Improvement of Lip Wrinkles)

  • 이선주;김미나;박성범;김기영;박선규;김미선;강내규
    • 대한화장품학회지
    • /
    • 제45권1호
    • /
    • pp.95-103
    • /
    • 2019
  • 입술은 각질층이 매우 얇아 수분증발에 취약하며, 노화 과정에서 주름이 증가하고, 붉은색을 잃으며, 볼륨이 감소하게 된다. 매력적인 입술을 가지기 위해 시행되는 지방이식, 필러 주입을 대체하기 위한 성분에 대한 연구는 아직 보고된 바가 거의 없으며, 최근 새로운 지방세포의 수를 증가시키는 것이 인체 내 지방을 늘릴 수 있는 방법으로 제안되고 있다. 우리는 선행연구에서 지방줄기세포를 지방세포로 분화 유도하는 천연물질로써 요엽후박나무 추출물(Magnolia officinalis bark extract)의 우수한 효능을 확인하였다. 본 연구에서는 요엽후박나무 추출물이 바이오 프린팅으로 제작한 지방 유사 구조체에서 지방(lipid droplet)의 양을 증가시키면서 분화를 촉진시킴을 3D 수준에서 확인하였다. 다음으로 입술 주름에 미치는 영향을 확인하기 위해 주름 사진으로 부터 명암값의 표준편차(SDGV)를 J 이미지 소프트 웨어를 사용하여 측정함으로써 객관적 측정 방법을 확립하였고, 주름 정도에 따른 입술 주름 그레이드를 도출하여 정량화하였다. 결과적으로 요엽후 박나무 추출물 1%를 함유한 제품을 12주간 사용했을 때, 입술 주름을 유의하게 개선시킬 수 있음을 확인하였다. 본 연구 결과는 요엽후박나무 추출물이 지방줄기세포를 지방세포로 분화 유도하는 효능을 가지며, 이러한 효능이 입술 주름을 개선하는데 도움을 줄 수 있다는 점을 시사하고, 따라서 요엽후박나무 추출물은 입술 주름과 볼륨을 개선하는 화장품 후보 소재로 적용 가능하다는 것을 보여준다.

전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석 (Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis)

  • 박준성;이상현;송찬희;노정훈;이치승
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권5호
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.

비소세포폐암 환자의 재발 예측을 위한 흉부 CT 영상 패치 기반 CNN 분류 및 시각화 (Chest CT Image Patch-Based CNN Classification and Visualization for Predicting Recurrence of Non-Small Cell Lung Cancer Patients)

  • 마세리;안가희;홍헬렌
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-9
    • /
    • 2022
  • 비소세포폐암(NSCLC)은 전체 폐암 중 85%의 높은 비중을 차지하며 사망률(22.7%)이 다른 암에 비해 현저히 높은 암으로 비소세포폐암 환자의 수술 후 예후에 대한 예측은 매우 중요하다. 본 연구에서는 종양을 관심영역으로 갖는 비소세포폐암 환자의 수술 전 흉부 CT 영상 패치의 종류를 종양 관련 정보에 따라 총 다섯 가지로 다양화하고, 이를 입력데이터로 갖는 사전 학습 된 ResNet 과 EfficientNet CNN 네트워크를 사용하여 단일 모델과 간접 투표 방식을 이용한 앙상블 모델, 그리고 3 개의 입력 채널을 활용한 앙상블 모델에서의 실험 결과 및 성능을 오분류의 사례와 Grad-CAM 시각화를 통해 비교 분석한다. 실험 결과, 종양 주변부 패치를 학습한 ResNet152 단일 모델과 EfficientNet-b7 단일 모델은 각각 87.93%와 81.03%의 정확도를 보였다. 또한 ResNet152 에서 총 3 개의 입력 채널에 각각 영상 패치, 종양 주변부 패치, 형상 집중 종양 내부 패치를 넣어 앙상블 모델을 구성한 경우에는 정확도 87.93%를, EfficientNet-b7 에서 간접 투표 방식으로 영상 패치와 종양 주변부 패치 학습 모델을 앙상블 한 경우에는 정확도 84.48%를 도출하며 안정적인 성능을 보였다.

치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향 (INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE)

  • 양정옥;김성교;권태경
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.537-549
    • /
    • 1998
  • 본 연구의 목적은 미세치근단 수술법에서 사용되는 치근단 절제방법 및 역충전와동 술식을 종래의 치근단 수술법에서 사용해 온 술식 및 방법과 치근단 미세누출의 측면에서 비교, 연구하고자 함이다. 치근단 절제방법 및 역충전와동 형성 방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 중절치, 측절치 및 견치 71개를 절제 각도 및 와동 형성방법에 따라 5개의 군으로 분류하여 실험하였으며, 근관협부 처리에 따른 치근단 누출을 평가하기 위해서는 최근 발거된 상악 제 1대구치의 근심협측 치근 44개를 근관협부의 처리 유무에 따라 2개군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 저속 round bur와 초음파 스테인레스 스틸 기구를 이용하여 역충전와동을 형성하고 IRM으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 홉광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였으며, 다음과 같은 결과를 얻었다. ${\cdot}$ 사면을 부여하지 않고 치아 장축에 대해 직각이 되게 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군과 저속 round bur를 이용한 군사이에는 미세누출에 있어서 유의한 차이가 나타나지 않았다(p>0.05). ${\cdot}$ 사면을 부여하면서 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군은 저속 round bur를 이용한 군에 비해 유의하게 적은 치근단 누출을 보였다(p<0.0001). ${\cdot}$ 초음파기구를 이용하여 역충전와동을 형성한 경우에는, 치근단 절제시 사면의 부여에 관계없이 치근단 누출에 유의한 차이가 나타나지 않았으나(p>0.05), 저속 round bur를 이용한 경우에는, 사변을 형성하지 않은 군이 사면을 형성한 군에 비해 유의하게 적은 미세누출을 나타내었다(p<0.0001). ${\cdot}$ 치근단 절제시 사변을 부여한 경우에는, 저속 round bur로 치아 장축에 평행하게 역충전와동을 형성한 군은 치아 장축에 직각으로 역충전와동을 형성한 군에 비해 미세누출이 적게 나타났지만, 유의한 차이는 나타나지 않았다(p>0.05). ${\cdot}$ 초음파 기구를 이용하여 근관협부를 따라 역충전 와동을 형성한 군은 저속 round bur를 이용하여 근관협부를 따라 역충전 와동을 형성하지 못한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.0001).

  • PDF

심폐바이패스 시 고탄산분압과 고관류법이 뇌대사에 미치는 영향 (The Effects of Hypercapnia and High Flow on Cerebral Metabolism During Cardiopulmonary Bypass)

  • 강도균;최석철;윤영철;최국렬;정신현;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • 제36권7호
    • /
    • pp.472-482
    • /
    • 2003
  • 심폐바이패스의 재가온 시기 동안 뇌산소 탈포화가 수술 후 신경학적 합병증 발생의 원인 중 한가지라고 보고된 바 있다. 따라서 심폐바이패스 동안 뇌산소 탈포화를 예방해 줌으로써 수술 후 신경학적 합병증 발생을 줄일 수 있으리라 생각된다. 본 연구는 심폐바이패스 동안 뇌산소 탈포화를 예방해주는 방법인 고탄산분압과 고관류가 뇌대사에 미치는 영향을 비교하기 위해 실시되었다. 대상 및 방법: 심장수술을 시행할 36명의 성인 환자들을 대상으로 심폐바이패스의 재가온 시기 동안 동맥혈액의 고탄산분압군(Pa$CO_2$ 45~50mmHg, n=18)과 고관류군(2.75 L/ $m^2$/min, n=18)으로 나누었다. 전체 환자들에 대해 중대뇌동맥 혈류 속도, 뇌동정맥혈 산소함량 차이, 뇌산소 대사율, 뇌산소 운반율, S-100 $\beta$ 농도 증가율, 뇌정맥혈 산소 탈포화도 등을 심폐바이패스 전, 심페바이패스 실시 10분, 재가온-1기(비인두 온도: 33$^{\circ}C$), 재가온-2기(비인두 온도; 37$^{\circ}C$), 심폐바이패스 종료 직후 등의 다섯 시기에 측정하였다. 그리고 수술 후 섬망 발생률과 지속시간 역시 조사하여서 위의 모든 변수들과 함께 양 그룹간에 비교하였다. 결과: 고탄산분압군이 고관류군 보다 재가온 시기 동안 중대뇌동맥 혈류 속도(157.88$\pm$10.87 vs 120.00$\pm$6.18%, p=0.006), 뇌정맥혈 산소분압(41.01$\pm$2.25 vs 32.02$\pm$1.67 mmHg, p=0.03) 및 포화도(68.01$\pm$2.75 vs 61.28$\pm$2.87%, p=0.03), 뇌산소 운반비율(110.84$\pm$7.41 vs 81.15$\pm$8.11%, p=0.003)이 유의하게 더 높았다. 재가온 동안 뇌동정맥 산소함량 차이(4.0$\pm$0.30 vs 4.84$\pm$0.38mg/dL, p=0.04), S-100 $\beta$ 증가율(391.67$\pm$23.40 vs 940.0$\pm$17.02%, p=0.003), 뇌정맥혈 산소 탈포화도(2명 vs 4명, p=0.04), 수술 후 섬망증의 지속시간(18 vs 34 hr, p=0.02)은 고탄산분압군이 고관류군에 비해 상대적으로 낮았다. 결론: 상기한 결과들을 비교 분석한 바 심폐바이패스 시 고탄산분안법이 고관류법 보다 뇌조직에 산소공급을 더 많이 해줌으로써 뇌대사가 상대적으로 원활하여 신경학적 합병증 발생률이 낮은 것으로 사료된다.

2015년 주요 의료판결 분석 (Review of 2015 Major Medical Decisions)

  • 유현정;이동필;이정선;정혜승;박태신
    • 의료법학
    • /
    • 제17권1호
    • /
    • pp.299-346
    • /
    • 2016
  • 2015년 한해에도 의료분야에서 다양한 판결이 선고되었다. 요양원 입소자에 대하여 요양원측 과실로 상해가 발생하여 요양원을 운영하는 사회복지법인이 환자의 진료를 의뢰한 사건에서 진료계약의 당사자 확정 기준이 제시되었고, 뇌사상태에 빠진 환자 가족의 무의미한 연명치료 중단 요구에 대하여 병원이 이를 거부하고 계속 진료한 경우 청구 가능한 진료비에 관한 판단이 이루어졌다. 안전성이 확인되지 아니하여 2011. 2. 보건복지부로부터 사상 초유의 시술중단조치를 받았던 눈미백수술에 관하여 법원은 시술 자체의 위법성을 인정하지는 아니하였으나 임상시험 단계에 있어 비용 대비 효과가 확립되어 있지 않다는 사실을 설명하지 아니한 설명의무 위반으로 전 손해의 배상을 명하였다. 의료과실을 적극적으로 인정한 판결로는 척추수술 후 마미증후군이 발생한 사건들에서 수술과정상 과실이 인정된 사례가 상당수 있었고, 병원감염 사건에서 감염을 유발한 과실을 인정한 판결이 선고되었다. 응급의료에 관한 법률상 응급장비 설치의무와 응급상황 발생시 조치의무를 구분하여 의료과실을 인정한 판결이 선고되었고, 극히 드문 희귀질환이라 하더라도 그에 대한 적절한 조치를 취하지 않은 의료기관에게 과실을 인정한 판결이 선고되었다. 손해배상의 범위와 관련하여 항소심 신체재감정 결과 노동능력상실률이 1심보다 작아지자 시간의 경과에 따라 노동능력상실률을 달리 적용하거나 환자의 상태에 따라 노동능력상실률을 신체감정 결과보다 낮게 인정하는 등 실체진실에 부합하는 판결이 선고되었다. 의료과실로 손해가 발생한 경우 의료사고 후 발생한 진료비에 책임제한이 적용되는지 여부와 관련하여 법원은 병원에서 환자 상태의 치유 또는 악화를 방지하는 정도의 치료만 계속되었다면 환자에게 진료비 지급을 청구할 수 없다는 이유로 병원 측의 상계주장을 배척하였다. 사전심의를 받지 않은 의료광고를 금지하고 그 위반시 처벌하는 의료법 규정에 대하여 사전심의기관인 대한의사협회 등의 행정기관성을 부인할 수 없어 사전검열에 해당한다는 이유로 위헌결정이 내려졌다. 임상에서 흔하게 시행되고 있는 PRP 치료가 법정비급여에 해당하는지 여부에 관하여 법원은 법정비급여 여부는 이론적인 가능성이나 실제 실시 여부 등에 따라 결정되는 것이 아니라 의학적 안전성 유효성을 인정받은 후 요양급여 또는 비급여대상으로의 편입절차를 거쳐야 함을 분명히 하였다. 또한 법원은 요양병원 적정성 평가에 관한 행정소송에서, 구조부문의 조사방식이나 절차상 위법을 인정하면서도 그 위법사유의 정도가 당연무효에까지는 이르지 아니하고 평가기관의 고의 과실이 없다는 이유로 건강보험심사평가원과 국민건강보험공단에 부당이득반환이나 손해배상의무가 없다는 판단을 하였다. 향후 더욱 다양하게 제기되는 쟁점들에 관하여 명쾌한 법리를 통해 실체진실에 다가가는 판결을 기대해본다.

  • PDF

내과적 문제로 수술이 불가능한 조기 비소세포성 폐암에서의 방사선치료 (Radiotherapy in Medically Inoperable Early Stage Non-small Cell Lung Cancer)

  • 김보경;박찬일
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.257-264
    • /
    • 2000
  • 목적 : 조기 비소세포성 폐암의 경우 수술이 최선의 치료법으로 생각 되고있다. 환자가 내과적인 질환으로 수술이 불가능한 경우, 혹은 수술을 거부한 경우 방사선치료가 수술의 대체적 치료로 사용 가능하다. 근치적방사선치료를 시행 받은 환자에서의 치료성적 및 이에 영향을 미치는 요인의 분석을 통하여 향후 치료에 도움을 얻고자 본 연구를 시행하였다. 대상 및 방법 : 서울대학교병원 치료방사선과에서 1987년 6월부터 1997년 6월 사이에 치료를 시행 받은 조직학적으로 진단된 조기 비소세포성 폐암 환자 32명을 대상으로 하였다. 수술이 불가능했던 이유로는 폐질환이 21명으로 가장 많았다. 대상환자의 중간 연령은 68세였으며, 조직학적으로는 편평상피암이 24명으로 가장 많았다. 임상 병기는 T1, T2, T3가 각각 5명, 25명, 2명이었으며, 진단시의 종양의 크기는 3$\~$5 cm가 13명으로 가장 많았다. 방사선치료는 6 MV또는 10 MV 선형가속기를 이용하여, 종양부위에 54.0$\~$68.8 Gy (중앙값; 61.2 Gy)를 조사하였고 12명의 환자에서는 동시분할조사를 시행하였다. 추적관찰기간은 2개월에서 93개월 (중앙값; 23개월)이었고, 생존기간은 치료개시일을 기준으로 산정하였다. 결과 : 전체생존률은 코년, 5년이 각각 44.6$\%$, 24.5$\%$이었으며, 무병생존률은 38.9$\%$, 28.3$\%$, 중앙생존기간은 23개월이었다. 전체환자 32명중 최종 추적관찰 시 25명이 사망하였으며, 이중 7명이 페암이외의 질환으로 사망하였다. 단변량분석 상 종양의 크기는 전체생존률과 무병생존률에 통계적으로 유의한 영향을 주는 요인으로 판정되었고 (p=0.0015, p=0.0022), T 병기는 전체생존률에 의미있는 요인으로 판정되었다(p=0.0395). 다변량분석 상 종양의 크기는 무병생존률에 통계적으로 의미있는 요인으로 판정되었으며(p=0.0317), 전체생존률에 영향을 주는 경향을 보였다 (p=0.0649). 종격동의 방사선조사 여부는 생존률에 영향을 주지 않았다. 결론 : 근치적방사선치료는 조기 비소세포성 폐암 환자로 내과적인 질환으로 수술 불가능한 경우나 환자가 수술을 거부한 경우, 특히 T1 또는 3 cm 이하의 종양에서는 수술적치료를 대치할 수 있는 치료법이다. 그러나 종양의 크기가 5 cm를 넘는 경우에는 방사선치료만으로는 장기생존자가 거의 없었으며, 따라서 이러한 환자의 치료에 있어 과분할조사나 기관지내 추가조사, 방사선감작제의 사용, 입체조형방사선치료, 강도변조방사선치료 등의 이용을 고려해야 할 것이다.

  • PDF