• Title/Summary/Keyword: Surgery, method

Search Result 5,431, Processing Time 0.034 seconds

Clinical Study on Implant Survival and Graft Resorption Rate After Maxillary Sinus Bone Grafting (상악동골이식 후 임플란트 생존율 및 골이식재의 흡수율에 관한 임상적 연구)

  • Lee, Jae-Hwan;Chee, Young-Deok;Min, Seung-Ki;Oh, Seung-Hwan;Kwon, Dae-Geun;Jeon, In-Chul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.529-536
    • /
    • 2010
  • Purpose: The Purpose of this study is to show the total survival rate of implants with maxillary sinus grafting and the effects that reach the survival rate by classifying types of graft materials, implant type, operation method, residual bone height and evaluate graft material resorption rate after sinus grafting Patients and Methods: 61 dental implants placed with sinus bone grafting in 24 patients at Wonkwang University Sanbon Dental Hospital were installed simultaneously or after regular healing. Various bone grafts (autograft, xenograft, allograft, alloplast) and fourth implant type (GSII, Xive, Implantium, Novel biocare) were used. All implants were investigated clinically and radiographically, being with average 20 months follow-up period after installation. Results: 3 fixtures were lost, resulting in 95.1% cumulative survival rate of 61 osseointegrated dental implant. Survival rate according to bone material type, Implant type, operation method, residual bone height, have no statistically significant differencies. The mean preoperative residual alveolar bone height was 4.75 mm, average postoperative height of graft materials 10.8 mm, vertical bone resorption rate was 10% after 2 years. Resorption rate according to operation method was 7% (simultaneous) and 5% (delayed) after 1 year. Conclusion: It can be suggested that maxillary sinus grafting may have predictable result with various bone graft materials and implant type, residual bone height, operation method

Innervated Cross-Finger Pulp Flap for Reconstruction of the Fingertip

  • Lee, Nae-Ho;Pae, Woo-Sik;Roh, Si-Gyun;Oh, Kwang-Jin;Bae, Chung-Sang;Yang, Kyung-Moo
    • Archives of Plastic Surgery
    • /
    • v.39 no.6
    • /
    • pp.637-642
    • /
    • 2012
  • Background Fingertip injuries involving subtotal or total loss of the digital pulp are common types of hand injuries and require reconstruction that is able to provide stable padding and sensory recovery. There are various techniques used for reconstruction of fingertip injuries, but the most effective method is functionally and aesthetically controversial. Despite some disadvantages, cross-finger pulp flap is a relatively simple procedure without significant complications or requiring special techniques. Methods This study included 90 patients with fingertip defects who underwent cross-finger pulp flap between September 1998 and March 2010. In 69 cases, neurorrhaphy was performed between the pulp branch from the proper digital nerve and the recipient's sensory nerve for good sensibility of the injured fingertip. In order to evaluate the outcome of our surgical method, we observed two-point discrimination in the early (3 months) and late (12 to 40 months) postoperative periods. Results Most of the cases had cosmetically and functionally acceptable outcomes. The average defect size was $1.7{\times}1.5$ cm. Sensory return began 3 months after flap application. The two-point discrimination was measured at 4.6 mm (range, 3 to 6 mm) in our method and 7.2 mm (range, 4 to 9 mm) in non-innervated cross-finger pulp flaps. Conclusions The innervated cross-finger pulp flap is a safe and reliable procedure for lateral oblique, volar oblique, and transverse fingertip amputations. Our procedure is simple to perform under local anesthesia, and is able to provide both mechanical stability and sensory recovery. We recommend this method for reconstruction of fingertip injuries.

Reconstruction of nasal ala and tip following skin cancer resection

  • Park, Young Ji;Kwon, Gyu Hyeon;Kim, Jun Oh;Ryu, Woo Sang;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.382-387
    • /
    • 2019
  • Background: Defects of the nasal ala and tip have a complex three-dimensional structure that makes them challenging to reconstruct. Many reconstructive options have been described for nasal ala and tip defects, ranging from primary closure to local flaps and skin grafts. However, it is difficult to determine which method will yield the best cosmetic results in each individual case. Thus, the purpose of this study was to determine which surgical procedures for reconstructing defects of the nasal ala and tip have better cosmetic results. Methods: From 2008 to 2018, 111 patients underwent surgery to reconstruct skin defects after resection of skin cancer in the nasal ala or tip. Their charts were reviewed to obtain data on age, sex, surgical location, size of the defect, surgical method, and cosmetic results using a visual analog scale (VAS). Results: For nasal ala reconstruction, the most commonly used surgical technique was the nasolabial flap (n= 42). This method also had the highest VAS score (7/10). The most commonly selected surgical method for nasal tip reconstruction was the bilobed flap (n= 13), and bilobed flaps and primary closure had the highest VAS score (7/10). Conclusion: Nasolabial flaps showed excellent cosmetic results for the reconstruction of nasal ala defects, while primary closure and bilobed flaps yielded excellent cosmetic results for the reconstruction of nasal tip defects.

Hindfoot Endoscopy for the Treatment of Posterior Ankle Impingement Syndrome: A Comparison of Two Methods (a Standard Method versus a Method Using a Protection Cannula) (후방 발목 충돌 증후군에서의 후족부 내시경 사용: 고식적 방법과 보호 도관을 이용한 방법의 비교)

  • Kim, Eung-Soo;Lee, Chang-Rak;Kim, Young-Jun;Roh, Sang-Myung;Park, Jae-Keun;Gwak, Heui-Chul;Jung, Sun-Gyu
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.1
    • /
    • pp.26-31
    • /
    • 2018
  • Purpose: The purpose of this study is to compare the clinical results between two different methods of hindfoot endoscopy to treat posterior ankle impingement syndrome. Materials and Methods: Between January 2008 and January 2014, 52 patients who underwent hindfoot endoscopy were retrospectively reviewed. Two methods of hindfoot endoscopy were used; Group A was treated according to van Dijk and colleagues' standard twoportal method, and group B was treated via the modified version of the above, using a protection cannula. For clinical comparison, the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, time required to return to activity, and the presence of complications were used. Results: There was no statistically significant difference in the AOFAS scores at the final follow-up, and there was also no statistically significant difference in the times for the scores to return to the preoperative level. There were no permanent neurovascular injuries and wound problems in either group. Conclusion: Use of protection cannula may provide additional safety during hindfoot endoscopy. We could not prove whether protection cannula can provide superior safety for possible neurovascular injury. Considering the possible safety and risk of using additional instrument, the use of this method may be optional.

Treatment of Syndactyly Using Small Subcutaneous Pedicled Flap (Small Subcutaneous Pedicled Flap을 이용한 합지증의 치험례)

  • Park, Sang Woo;Kang, Dae Il;Choi, Tae Hyun;Lee, Kyung Suk;Kim, Nam Gyun;Kim, Jun Sik
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.777-781
    • /
    • 2005
  • Syndactyly and polysyndactyly are one of the most common congenital anomalies of upper limb. Although there are many surgical approaches, most of them require skin graft for covering the raw surfaces. Therefore these methods involve many disadvantages such as grafted skin contracture, web recurrence, skin graft loss and long operation time, and the grafted hyperpigmented skin and donor site of skin graft, which lead to poor results aesthetically. The authors treated seven cases with a Hayashi's new method in four patients. In this method, tissue of interdigital space are regarded as forming 4 facets of a two piled cube. A dorsal rectangular flap on dorsum of interdigital web makes a new interdigital space. One side of divided digit is coverd with lateral based plantar flap and the other side of divided digit is covered with subcutaneous pedicled flap and remnant web skin. The authors could obtain natural deep interdigital space without web recurrence and scar contracture in 7 cases. Moreover this method does not require skin grafting, accordingly produces better aesthetic results without hyperpigmentation and donor site scaring. Therefore we report this operation technique, which might be used as one of the standard in surgical correction of syndactyly and polysyndactyly.

Treatment of Peritonsillar Abscess: Needle Aspiration versus Incision and Drainage

  • Cho, Seung-Hyun;Kwon, Soon-Young;Lee, Seung-Hoon;Cho, Jae-Hoon;Choi, Ji-Ho;Baik, Seung-Hoon;Yoo, Chan-Kee
    • Korean Journal of Bronchoesophagology
    • /
    • v.13 no.1
    • /
    • pp.19-22
    • /
    • 2007
  • Background and Objectives: The Objective of this study was to compare the effectiveness of the needle aspiration method and the I&D method in the treatment of peritonsillar abscess. Materials and Methods: A prospective clinical study was performed on 83 patients. All the patients were hospitalized after random treatment with either I&D or needle aspiration alone, received the same intravenous antibiotic therapy. Among the 83 patients, 73 patients who could be observed for longer than 6 months and had not undergone a tonsillectomy during the follow-up period, were analyzed for treatment outcomes. Results: There was no statistically significant difference in the initial failure rate(p=0.572), the hospitalized days(p=0.956), the recurrence rate(p=0.531) for the needle aspiration(35 patients) and I&D groups(38 patients). But, The mean duration of fever were statistically different in the needle aspiration(1.51 hours) and I&D groups(3.05 hours) (p=0.031). Conclusion: Two methods are thought to be similar in effectiveness, except that duration of fever was longer in the I&D group than in the needle aspiration group. However, taking advantages of the needle aspiration method into consideration, the needle aspiration of peritonsillar abscess may be more appropriate than I&D as an initial method for peritonsillar abscess

  • PDF

Effective Reduction of the Frontal Process of the Maxillary Fracture Segment Using Intermaxillary Fixation Screw (악간고정용 스크류를 이용한 위턱뼈 이마돌기 골절편의 효과적인 정복)

  • Moon, Suk-Ho;Lee, Woo-Sung;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Oh, Deuk-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.555-558
    • /
    • 2011
  • Purpose: It is relatively unusual that infraorbital rim fracture is accompanied by nasal bone fracture. In order to correct effectively, subciliary approach and intranasal manipulation are applied simultaneously. But if reduction is not successful, intranasal manipulation may become aggressive and this often causes complications. We introduce a method using intermaxillary fixation screws for decreasing such complications and effective reduction of fracture. Methods: Total seven patients with fracture of frontal process of maxilla were treated with this method. The fracture site was exposed through the subciliary approach, and one or two screws were inserted into the displaced fracture fragment. During the traction of the screws using the wire, the fracture fragment was pushed upward from the intranasal side using an elevator supplementarily and fixed with a plate and the screws. Results: In all patients, the fracture fragment was reduced successfully and no complication occurred during one year's postoperative follow-up. Conclusion: When reduction cannot be attained through a bone hook or an elevator alone, reduction of fracture fragment can be done easily using intermaxillary fixation screws. This method is less likely to cause a mucosal injury because intranasal manipulation is not aggressive. Furthermore, as the screw can be inserted and removed easily, this method is considered effective not only for fracture of frontal process of maxilla but also for fractures in other regions.

Virtual Plastic Surgery using Adobe Photoshop® (Adobe Photoshop®을 이용한 가상성형수술의 유용성)

  • Choi, Jun Young;Kim, Jong Hwan;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.582-588
    • /
    • 2005
  • Digital imaging is emerging as a standard method for patient documentation in clinical setting. Managing patient expectations before aesthetic surgery can greatly improve patient satisfaction after surgery. The patient who visited for plastic surgery wants a predicted figure after the operation. A virtual plastic surgery software is necessary in order to satisfy the desire of patients. Adobe $Photoshop^{(R)}$ is the professional standard in desktop digital imaging, offers indispensable new features for graphic and web design, photography, and video. Using imaging technology, it takes just minutes to realistically simulate the results of double eyelid operation, liposuction, rhinoplasty or any other aesthetic procedure. The aim of this study is to analyze the significance of the digital image processing and to introduce the virtual plastic surgery using Adobe $Photoshop^{(R)}$.

Robot assisted THA surgery using gauge based registration (게이지 정합 방법을 이용한 소형 인공고관절 수술로봇의 개발)

  • Shin, Ho-Chul;Park, Young-Bae;Yoon, Yong-San;Kwon, Dong-Soo;Lee, Jung-Ju;Won, Chung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.482-484
    • /
    • 2001
  • In orthopedics, hip arthroplasty is the operation that replaces damaged hip joint to artificial joint. In hip arthroplasty, quite better result can be achieved if robot is applied to machine cavity in bone, especially when cementless stem is used. So several kinds of robots were introduced for hip arthroplasty, but they used MRI, CT Scan, vision analysis and real time tracking of bone position for registration of robot. To overcome shortage of conventional robot surgery, gauge based registration method was proposed and small robot was designed. In this method, small robot is mounted on femur, and its position is determined by gauge registration method. Operation procedure was performed on model femur and result was analyzed. This robotic hip surgery system is expected to more adaptable in operation room.

  • PDF

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method

  • Park, Hyung-Jin;Kim, Hee-June;Kim, Shukho;Kim, Seong-Min;Mun, Jong-Uk;Kim, Jungmin;Kyung, Hee-Soo
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.427-432
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method. Methods: Nineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant Staphylococcus aureus (MRSA) was inoculated into 10 implants and sterilization in a standard autoclave was performed, and then the fluid was cultured before and after sonication. Results: Two of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were Staphylococcus species in all two cases. In one of 10 implants inoculated with MRSA, the culture was positive for growth of bacteria both before and after sonication. However, Staphylococcus epidermidis was cultured from both occasions and thus this implant was thought to be contaminated. Conclusions: We found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.