• 제목/요약/키워드: Surge tank

검색결과 50건 처리시간 0.022초

수압조절수조(Surge Tank)에 관한 연구 (A Study on the Surge Tank)

  • 남선우
    • 물과 미래
    • /
    • 제6권1호
    • /
    • pp.29-35
    • /
    • 1973
  • For the simplicity in the analytical solution, the simple surge tank has been chosen for the test where an unsteady flow is porduced by suddenly closing the valve controlling the discharge. The valve is loated immediately downstream from the surge tank. Momentumn equations in the penstock and in the surge column are measured recored on the oscillograph and then the calibration of surge column heights and scale readings on the oscillograph trace are made. The diameter of the penstock are determined by the trial and error method. The water levels in the surge column are computed by numerical integration of the differential equation of the surge tank. The relationships between the results from the experiment and numerical computation are figured, compared and discussed.

  • PDF

노출형 조압수조의 해석모델별 내진성능평가 (Seismic Performance Assessment of Atmospheric Surge Tank)

  • 김용곤;옥승용;김일규;류선호;배정주
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.67-73
    • /
    • 2016
  • This study investigates the seismic performance of the surge tank which is of the atmospheric type and constructed above the ground. For that purpose, three different numerical models of the surge tank have been taken into account. Two models are constructed to describe the surge tank with different support conditions: one is to model all supports as fixed, and the other is to use spring element for the rock conditions. The third model is constructed to describe not only the surge tank with spring element of the rocks but also the vertical waterway tunnel. Through the time-history analysis of the surge tank subjected to three artificially excited ground motions, it is demonstrated that there can be much difference between the three models of our interest according to the support conditions and inclusion of the vertical waterway tunnel. However, their seismic performances still remain below the safety criteria, i.e., dynamic allowable stress. Also, the numerical results let us know where the critical sections occur. These results could be used to develop the efficient seismic enhancement method for the surge tank.

수위변화에 따른 조압수조 내 수면진동에 대한 분석 (Analysis of Water Surface Oscillation in the Surge Tank Due to the Variation of Water Level)

  • 전계원;이호진;박재성;안상도;윤영호
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.441-444
    • /
    • 2007
  • Surge tank generally are used near the downstream end of tunnels of penstocks to reduce change in pressure caused by waterhammer resulting from load changes on the turbines. In this paper, the surge tank with chamber is selected to analyze water surface oscillation. the governing equation are derived using the law of conservation of mass and momentum. the water surface oscillation in the surge tank are computed using governing equation. In the case of upsurging, water surface oscillation is damped gradually and in the case of downsurging, it is damped rapidly.

  • PDF

부정류 효과를 고려한 조압수조가 있는 상수관망의 파괴확률 (Probability of Pipe Breakage for Pipe Network with Surge Tank regarding Unsteady Effect)

  • 권혁재;이철응
    • 한국수자원학회논문집
    • /
    • 제42권10호
    • /
    • pp.785-793
    • /
    • 2009
  • 본 연구에서는 부정류 상태의 조압수조를 해석 할 수 있는 수치모형이 개발되었다. 그리고 부정류 효과를 고려한 파이프의 파괴확률 산정을 위한 신뢰성 모형이 개발되었다. 파이프 파괴의 상대적 위험도 평가와 조압수조의 기능성 평가를 위해 부정류 효과를 고려한 조압수조가 있는 상수관망 시스템의 파괴확률을 산정하였다. 신뢰성 해석을 통하여 부정류가 파괴확률을 크게 증가 시키는 것을 알 수 있었으며 조압수조가 부정류의 압력을 크게 감쇠시킴으로써 파괴확률을 현저히 저하시키는 것을 확인할 수 있었다.

댐 안전관리를 위한 조압수조의 규모 결정 (Determination of Surge Tank Scale for Dam Safety Management)

  • 이호진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.164-174
    • /
    • 2007
  • 댐에서 관로 시스템을 효과적으로 설계하기 위해서는 수격작용과 같은 과도수리현상을 해석해야 만 한다. 일반적으로 조압수조는 터빈의 부하변화에 의한 과도수리현상에 의해 발생되는 압력의 변화를 감소시키기 위해서 사용된다. 본 연구에서는 댐 안전관리를 위한 조압수조의 적정규모를 조사하였다. 지배방정식을 이용하여 조압수조 내 수위변동을 계산하였다. Thoma-Jaeger의 안정조건을 사용하여 홍수위, 상시만수위, 정격수위, 저수위인 경우에 정적안정조건과 동적안정조건을 검토하였다. 끝으로 조압수조의 수직갱과 수실의 적정 지름을 결정하였다.

Surge-Tank의 응력해석 및 최적설계 (Stress analysis and optimal design of surge-tank)

  • 이수훈;지상현;김민수
    • 오토저널
    • /
    • 제12권3호
    • /
    • pp.3-8
    • /
    • 1990
  • 본 고에서는 자동차의 냉각장치중, 냉각수를 저장하는 기능을 갖는 surge-tank의 내압에 의한 국부적인 균열 발생 방지 및 용기의 응력환화를 목적으로, 범용 구조해석 프로그램인 CAEDS의 여러 모듈(GEOMOD, GFEM, IFES, OPTISEN)을 이용하여 응력해석을 수행한 후, OPTISEN(최적화 해석 모듈)을 적용하여 용기 두께 및 보강재 위치에 따른 설계민감도를 구하여 최적 두께 및 보강재의 최적 위치를 구하였다.

  • PDF

Surge Tank가 설치된 상수도관망에서 부정류를 고려한 불능확률 산정 (Calculation of Probability of System Failure for Pipe Network with Surge Tank regarding Unsteady Flow)

  • 권혁재;이철응
    • 상하수도학회지
    • /
    • 제23권3호
    • /
    • pp.295-303
    • /
    • 2009
  • In the present study, a reliability analysis calculating the probability of system failure has been performed using cut set and results of numerical analysis for unsteady flow in pipe. Especially, the probability of system failure has been evaluated regarding the effect of valve closure which is a really important activity in operation of piping system. In spite of small amount of demand, it was found that fast valve closure can generate high probability of system failure. Furthermore, it was confirmed that surge tank can reduce the unsteady effects and probability of system failure in water distribution system. From the results, it was found that the unsteady flow has a significant effect on the probability of system failure Furthermore, it was able to find which pipe or cut set has high probability of system failure. So it could be used to determine which pipe or cut set has a priority of repair and replacement. Therefore, reliability analysis regarding unsteady flow has to be performed for the planning, designing, maintenance, and operation of piping system.

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

Cavitation Surge in a Small Model Test Facility simulating a Hydraulic Power Plant

  • Yonezawa, Koichi;Konishi, Daisuke;Miyagawa, Kazuyoshi;Avellan, Francois;Doerfler, Peter;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권4호
    • /
    • pp.152-160
    • /
    • 2012
  • Model tests and CFD were carried out to find out the cause of cavitation surge in hydraulic power plants. In experiments the cavitation surge was observed at flow rate, both with and without a surge tank placed just upstream of the inlet volute. The surge frequency at smaller flow rate was much smaller than the swirl mode frequency caused by the whirl of vortex rope. An unsteady CFD was carried out with two boundary conditions: (1) the flow rate is fixed to be constant at the volute inlet, (2) the total pressure is kept constant at the volute inlet, corresponding to the experiments without/with the surge tank. The surge was observed with both boundary conditions at both higher and lower flow rates. Discussions as to the cause of the surge are made based on additional tests with an orifice at the diffuser exit, and with the diffuser replaced with a straight pipe.

조압수조의 수리모형실험과 수치해석 (Hudraulic Model Test and Numerical Analysis of the Surge Tank)

  • 노재화;이희영
    • 물과 미래
    • /
    • 제17권1호
    • /
    • pp.45-56
    • /
    • 1984
  • 협천댐의 인구 조압수조의 모형설계로부터 실험결과에 이르기 까지의 과정을 검토하였다. 그리고 실험결과는 Runge-Kutta-Gill 방법에 의한 수치해석과 비교하였다. 그 비교결과는 상당히 일치하였다. 설계기간이 아주 짧거나 예산면에서 어려움이 있는 경우이거나, 협천댐과 같이 비교적 간단한 조압수조의 경우는 수치해석만으로 설계하여도 가능하다고 판단된다.

  • PDF