• 제목/요약/키워드: Surge Arrester

검색결과 142건 처리시간 0.026초

전철 탑재형 피뢰기의 모듈설계 및 성능평가기술 (Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock)

  • 조한구;김석수;한세원;이운응
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

직류+60[Hz]교류 중첩전압에 대한 18[kV] ZnO 피뢰기의 전기적 특성 (Electrical Properties of 18[kV] ZnO Surge Arrester Stressed by the Mixed DC and 60[Hz] AC Voltages)

  • 이수봉;이승주;이복희
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.66-72
    • /
    • 2007
  • 이 논문은 직류+60[Hz] 교류 중첩전압에서 신품과 노후된 18[kV] 산화아연 서지피뢰기의 누설전류와 전력손실에 대하여 기술하였다. 최대 50[kV]의 직류+60[Hz] 교류를 발생시킬 수 있는 중첩전압발생장치가 설계되고 제작되었다. 피뢰기의 I-V 특성곡선은 전압중첩률 K의 함수로 측정된다. DC와 AC 전압이 중첩된 I-V, R-V 특성곡선은 순수한 직류와 교류곡선 사이에 있고 저전류 영역에서 교차현상이 나타난다. 그 결과 중첩 전압에서 직류 성분의 증가는 ZnO 피뢰기의 전체 누설전류의 저항성분의 증가를 유발한다. 또한 같은 인가전압에서 피뢰기를 통해 흐르는 누설전류는 상용전원에서 장시간 스트레스 받은 피뢰기가 신품 피뢰기에 비해서 높게 나타났다.

ZnO 피뢰기의 경년변화 특성분석 (Aging Characteristics of ZnO Surge Arresters)

  • 김주용;김찬영;송일근;이병성;한용희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 1999
  • Surge arrestor is used for protection of facilities and lines. Recently lots of arresters fatted prematurely In the distribution lines. It is important to know that what the cause of the failures is. This paper presents characteristics of the aged and new 18kV surge arrester. In order to analyse characteristics, we measured leakage current using specialty made leakage current measurement system and also investigated Tan $\delta$ of the arrester and microstructure of the elements. Through the investigation we found that the characteristics among the ZnO elements in an arrester were a little different, It means that the surge arreste can have non-uniform electric field due to the characteristic difference of The each element. Owing to this concentration of the electric field, the localized aging might be proceeded.

  • PDF

뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성 (Degradation Properties of ZnO Surge Arresters Due to Lightning Impulse Currents)

  • 이수봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권4호
    • /
    • pp.79-85
    • /
    • 2009
  • 이 논문은 피임펄스전류의 입사에 따른 ZnO 피뢰기의 열화 특성에 대하여 기술하였다. 뇌서지에 의한 ZnO 피뢰기의 열화특성을 분석하기 위해 시료 ZnO 피뢰기에 8/20[${\mu}s$], 2.5[kA]의 표준뇌임펄스전류를 인가하였다. 뇌임펄스전류를 인가한 것과 인가하지 않은 ZnO 피뢰기에 흐르는 상용주파수 AC 및 DC 누설전류를 측정하였다. 그 결과 임펄스전류의 인가횟수가 증가함에 따라 누설전류는 증가하였고 AC전압에서 누설전류의 비 대칭성은 뚜렷하게 나타났다. 뇌임펄스전류를 인가하지 않은 ZnO 피뢰기의 ZnO 입자는 균일한데 반해 뇌임펄스전류를 인가한 ZnO 피뢰기의 ZnO 입자는 불균일하게 변형되었다. 또한 뇌임펄스전류 인가에 따른 $Bi_2O_3$의 감소가 입계층의 결핍을 발생시키며 입계층의 결핍에 의한 전류의 집중이 ZnO 피뢰기 소자의 비선형 특성의 열화에 대한 중요한 요인으로 작용한 것으로 밝혀졌다.

폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성 (Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing)

  • 조한구;유대훈;이운용;김하나
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

직류전동차용 피뢰기 진단기술 (Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles)

  • 길경석;송재용;김일권;문승보;신광철
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.

외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화 (Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions)

  • 이승주;이수봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.62-68
    • /
    • 2008
  • 이 논문은 ZnO 피뢰기의 외부환경 변화에 따른 전기적 특성을 기술하였다. 뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성을 분석하기 위해 8/20[${\mu}s$], 2.5[kA]의 임펄스전류를 시료에 인가하였다. ZnO 피뢰기의 누설전류를 다양한 외부 온도와 주수 상태에서 상용 주파수 교류 전압을 인가하여 측정하였다. 그 결과 임펄스전류의 인가횟수와 외부 온도가 증가함에 따라 누설전류가 증가하였고, 누설전류의 비대칭성도 뚜렷하였다. 또한 주수 시험에서 ZnO 피뢰기의 외피를 통하여 흐르는 전류는 피뢰기 소자의 누설전류보다 크게 나타났다. 본 연구의 결과는 피뢰기의 감시시스템 성능과 신뢰성 향상의 요소로 적용할 수 있다.

발전소내 스위치야드 및 주변압기간 연결선로의 적정 피뢰기 위치 선정 (A STUDY ON EFFECTIVE APPLICATION OF SURGE ARRESTER BETWEEN THE SWITCHYARD AND MAIN TRANSFORMER IN POWER PLANT)

  • 이흥찬;함영수;정기수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.503-505
    • /
    • 1995
  • The surge arrester plays a vital role in the protection of substation against transient overvoltages resulting from lightning surges and system switching operations. The proper selection and application of the surge arrester is an integral part of the process of substation equipment insulation level selection. The paper outlines the basic consideration in modeling the lightning stroke, the surge arrester, and the system to be protected. The paper discusses the results of various cases simulated using the alternative transient computer program to evaluate the separation effects.

  • PDF

발.변전용 폴리머 피뢰기의 기밀특성에 따른 신뢰성 평가 (Reliability Evaluation of Polymer Arrester with Sealing Integrity for Station and Substation)

  • 유대훈;이운용;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.326-327
    • /
    • 2006
  • The paper describes the development of arrester for 154kV class power station and substation. The arrester employs silicone insulating materials for Its housing, instead of the conventional porcelain housing. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters for ultra high voltage is investigated with moisture ingress test. The diagnostic techniques are discusses, including watt loss, partial discharge, AC leakage current, 1mA DC voltage and residual voltage.

  • PDF

피뢰기용 단로기의 특성 및 성능 평가 (Properties & Performance Evaluation of Disconnector for Surge Arrester)

  • 김석수;최익순;정낙헌;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.546-547
    • /
    • 2005
  • This study aims to evaluate the properties and the performance of the newly designed disconnector for surge arrester. This disconnector was verified with the performance in long-duration current impulse test and high current impulse test. And time-current characteristic test was done at 20A, 200A and 800A(3points) for simulating the internal fault condition of the arrester. The results of this test was very good. Consequently, the newly designed disconnector was, evaluated that it is possible to be used for surge arrester in distribution line system.

  • PDF