• Title/Summary/Keyword: Surface temperature control

Search Result 1,059, Processing Time 0.024 seconds

Estimation of Hardened Layer Dimensions Using Multi-Point Temperature Monitoring in Laser Surface Hardening Processes (레이저 표면 경화 공정에서 다점 온도 모니터링을 통한 경화층 크기 예측)

  • 우현구
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1048-1054
    • /
    • 2003
  • In laser surface hardening processes, the geometrical parameters such as the depth and the width of a hardened layer can be utilized to assess the hardened layer quality. However, accurate monitoring of the geometrical parameters for on-line process control as well as for on-line quality evaluation is very difficult because the hardened layer is formed beneath a material surface and is not visible. Therefore, temperature monitoring of a point of specimen surface has most frequently been used as a process monitoring method. But, a hardened layer depends on the temperature distribution and the thermal history of a specimen during laser surface hardening processing. So, this paper describes the estimation results of the geometric parameters using multi-point surface temperature monitoring. A series of hardening experiments were performed to find the relationships between the geometric parameters and the measured temperature. Estimation results using a neural network show the enhanced effectiveness of multi-point surface temperature monitoring compared to one-point monitoring.

A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations (시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구)

  • 김용이;윤혜림;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

Surface Temperature Control of an Insulated Horizontal Pipe under Thermal Radiation Environment (복사효과를 포함하는 수평관 표면의 온도제어)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • Procedures for estimation of insulation thickness for a horizontal pipe for condensation control or personnel protection has been investigated, parallel to the previous work of a vertical wall case. Parameters include pipe diameter, emissivity, thermal conductivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation, specially for the case of high temperature application with low Bi. The effect of surface radiation in such case could be up to 65% of the total. Required insulation thickness for the surface temperature control increases as pipe diameter increases and as surface emissivity decreases. Adequate revision of specifications or standards to include newly invented insulation materials with high emissivity has been also suggested.

A study on the monitoring and control of the back bead width in arc welding with consumable blectrode (소모성 전극의 아크 용접에서 이면비-드 폭의 모니터링과 제어에 관한 연구)

  • 부광석;오준호;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.329-334
    • /
    • 1987
  • The purpose of this study is to monitor and control the back bead width in arc welding with consumable electrode for reduction of the occurrence of weld defect. The temperature of a point on the weldment surface is selected, as a monitoring parameter, and measured by an optical infra-red sensor. The correlation between the back bead width and the surface temperature is experimentally obtained for various thicknesses of the weldment. The welding travel speed and the surface temperature are taken, respectively, as an input and an output of the welding process under the stable condition of arc. A PI control scheme to maintain the surface temperature at the desired level is proposed by the experimental study.

  • PDF

Temperature control for a hot water heating circulating pump system using a nonlinear sliding surface (비선형 슬라이딩 면을 이용한 온수난방 순환펌프 시스템의 온도 제어)

  • Ahn, Byung-Cheon;Cang, Hyo-Whan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.2
    • /
    • pp.162-168
    • /
    • 1997
  • Digital variable structure controller(DVSC) is implemented to control the temperature for the hot water heating circulating pump control system. For the DVSC, a control algorithm is suggested, which using a nonlinear sliding surface and a PID sliding surface outside and inside of steady state error boundary layer, respectively. Smith predictor algorithm is used for the compensation of long dead time. The DVSC of the suggested algorithm yields improved control performance compared with the one of existing algorithm. The system responses with the suggested DVSC shows good responses without overshoot and steady state error inspite of heating load change. By decreasing sampling time, dead time and rise time are increasing, and system output noise by flow dynamics is amplified.

  • PDF

A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol (온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구)

  • 임재한;여명석;양인호;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.7
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

The Effective Heating Control Method of the Radiant Floor Heating System (바닥복사 난방공간의 효율적인 난방제어방법)

  • Cho, S.H.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

A study on monitoring and control in laser transformation hardening process (레이저 표면 경화 공정의 계측 및 제어에 관한 연구)

  • 우현구;조형석;한유희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.883-888
    • /
    • 1993
  • This paper proposes a monitoring method using an infrared temperature sensor in laser surface hardening process. To investigate the validity of the method a series of experiments are performed for various conditions. The experimental results show that the surface temperature depends upon the laser power, travelling speed and surface conditions of a specimen. Especially, the laser surface hardening process is greatly influenced by the surface conditions of the specimen, such as coating thickness and materials.

  • PDF

A Study of the Infrared Temperature Sensing System for Surface Temperature Measurement in Laser Welding(I) - Surface Temperature Profile According to Bead Shape - (레이저용접부 온도측정을 위한 적외선 온도측정장치의 개발에 관한 연구(I) -용융부 형상에 따른 표면온도분포-)

  • 이목영;김재웅
    • Journal of Welding and Joining
    • /
    • v.20 no.1
    • /
    • pp.62-68
    • /
    • 2002
  • This study investigated the feasibility of penetration depth measurement using infrared temperature sensing on the weld surface. The detection point was optimized by FEM analysis in the laser keyhole welding. The profile of the weld surface temperature was measured using infrared detector array. Surface temperature behind the weld pool is proportional or exponentially proportional to penetration depth and bead width. From the results, the monitoring device of surface temperature using infrared detector array was applicable fur real time penetration depth control.

A Quantitative Study on the Effect of Temperature Control by a Shade Tree and the Lawn Area (식물의 온도 완화효과에 관한 기초적 연구)

  • 안계복;김기선
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study is to investigate the effect of temperature control by a shade tree and the lawn area. In this investigation, we find out that artificial-lawn, concerte, and exposed soil are more higher temperature than covered with plant materials. The results of the measurement may to summerized as follows; 1) Low-temperature effects of zoysia japonica is more controlled by condition of growth than leaf length of grass. Surface temperature make 0.7$^{\circ}C$ difference between long grass (15cm), and short grass (5cm), but make 5$^{\circ}C$ difference between good growth grass (230/10$\textrm{cm}^2$) and bad growth grass (80/10$\textrm{cm}^2$). 2) The surface temperature of the lawn area is 40.5$^{\circ}C$ lower on a maxinum than that of the artificial lawn (July 28, 1985). During the day of summer, shade area under the shade tree is 0.9$^{\circ}C$ lower then lawn area surface temperature, 6.9$^{\circ}C$ lower than bad growth lawn, 10.3$^{\circ}C$ lower than exposed soil, and 18$^{\circ}C$ lower than concrete surface temperature. 3) Natural irrigation effect on the surface temperature fluctuation. But this effect is changed by compositions of ground materials and time-lapse. 4) Sunny day is more effective than cloud day. 5) In summer season, surface temperature make a difference compare to temperature of 0.5-1.5m height from ground : Surface temperature is 3.4$^{\circ}C$ lower at the lawn area (11 a.m.), 4.2$^{\circ}C$ lower at the shade area the shade tree, 12.7$^{\circ}C$ higher at the concrete area (3p.m.), 38.8$^{\circ}C$ higher at the artificial lawn (2p.m.) 6) According to compositions of ground materials and season have specific vertical temperature distribution curve. 7) In summer season, temperature distribution of 0.5-1.5m hight at the shade tree is 4.8-5.7$^{\circ}C$ lower than concrete area (noon-3p.m.)

  • PDF