High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가 (Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope)

  • 정재훈;이충운;유연욱;서영덕;최호용;김윤철;김용근;원우재
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.44-49
    • /
    • 2017
  • 목적: 핵의학 검사를 시행한 병동 환자의 시간과 거리에 따른 방사선량률을 측정하여 방사성동위원소 투여를 받은 환자가 병동 간호사에게 미치는 피폭을 예측하고 실제 총 피폭량과 비교하여 보고자 한다. 대상 및 방법: 병동에서 근무하고 있는 간호사 14명을 대상으로 열형광 선량계와 광자극 선량계를 이용하여 방사선 피폭선량을 측정하였고 핵의학 검사를 시행한 환자 50명(PET/CT 20명, Bone scan 20명, Myocardial SPECT 10명)을 대상으로 방사성동위원소 투여 직후와 검사시행 직후에 표면, 50cm, 1m에서 외부 방사선량률을 측정하였다. 측정 결과를 바탕으로 유효반감기를 도출한 후 병동 간호사가 받을 수 있는 피폭량을 예측하였다. 그리고 열형광선량계와 광자극선량계로 측정된 병동 간호사의 실제 총 피폭량과 비교 하였다. 결과: 병동 간호사 14명을 대상으로 한 피폭선량 측정결과 평균값과 최대값은 각각 분기당 0.01 mSv, 0.02 mSv 이었고 핵의학 검사를 시행 받은 환자의 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $376.0{\pm}25.2{\mu}Sv/hr$, $88.1{\pm}8.2{\mu}Sv/hr$, $29.0{\pm}5.8{\mu}Sv/hr$ 이고 Bone scan은 $206.7{\pm}56.6{\mu}Sv/hr$, $23.1{\pm}4.4{\mu}Sv/hr$, $10.1{\pm}1.4{\mu}Sv/hr$이고 Myocardial SPECT는 $22.5{\pm}2.6{\mu}Sv/hr$, $2.4{\pm}0.7{\mu}Sv/hr$, $0.9{\pm}0.2{\mu}Sv/hr$이다. 또한 검사를 시행한 후 측정한 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $165.3{\pm}22.1{\mu}Sv/hr$, $38.7{\pm}5.9{\mu}Sv/hr$, $12.4{\pm}2.5{\mu}Sv/hr$ 이고 Bone scan은 $32.1{\pm}8.7{\mu}Sv/hr$, $6.2{\pm}1.1{\mu}Sv/hr$, $2.8{\pm}0.6{\mu}Sv/hr$이고 Myocardial SPECT는 $14.0{\pm}1.2{\mu}Sv/hr$, $2.1{\pm}0.3{\mu}Sv/hr$, $0.8{\pm}0.2{\mu}Sv/hr$이다. 위의 결과를 바탕으로 유효반감기를 도출한 후 검사종료 30분 후 원자력안전법에서 규정하는 일반인 선량한도까지 도달하는데 걸리는 시간을 반감기를 고려치 않고 보수적으로 계산하면 PET/CT는 표면, 50cm, 1m 거리 순으로 7.9시간, 34.1시간, 106.8시간이며 Bone scan은 40.4시간, 199.5시간, 451.1시간이고 Myocardial SPECT는 62.5시간, 519.3시간, 1313.6시간이다. 결론: 본 연구 결과에 의하면 병동 간호사는 일반인 선량한도 보다 훨씬 적은 피폭량을 받는 것으로 나타나, 실질적으로 판단할 때 핵의학 검사를 시행한 환자로 인하여 받는 피폭의 영향은 미미한 것으로 판단된다.

  • PDF

산란전자선을 이용한 강내측방조사기구의 제작과 특성 (Fabrication of Backscatter Electron Cones for Radiation Therapy)

  • 추성실;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.74-80
    • /
    • 2001
  • 목적 : 강내에 발생된 종양치료용 원통형 전자선 조사기구(Electron cone)는 기하학적으로 강내벽에 위치한 종양치료에 부적당하므로 후방 또는 측면방향으로 산란되는 전자선을 이용하여 체강 내벽점막 등에 발생된 종양을 효과적으로 치료할 수 있는 산란전자선 치료방법을 개발하고자 한다. 강내조사기구내에 전자선 입사방향에 수직 또는 일정한 각도의 산란판을 배치하여 측면방향으로 산란전자선을 방출시키는 강내 측면조사기구를 제작하고 산란판의 제원과 전자선 에너지에 따라 산란방출된 산란선의 특성과 조직내 선량분포를 측정 평가하였다. 새상 미 방법 : 외부조사용 전자선조사기구(Electron cone) 대신에 강내 삽입용 전자산란선 조사통(Intracavitary backscatter electron cone)과 이를 콜리메이터와 연결시킬 수 있는 차폐연결기구(Shielded electron device)를 고안하였다. 산란전자선 조사기구는 직경이 $2\~3\;cm$이고 길이가 25 cm인 금속(내식강)원통을 이용하였으며 입구에서 20 cm위치에 산란판을 부착시키고 원통 측면에 직경 $1\~2\;cm$의 산란선 방출구를 제작하였다. 산란판은 $2\~10\;mm$의 연판을 사용하였으며, 오제전자와 특성 엑스선을 제거하기 위하여 주석, 구리, 알루미늄판 등을 부착시켰으며 종양위치를 관찰할 수 있도록 표면을 처리하였다. 고에너지 방사선치료용 선형가속기(Clinac 2100C/D)에서 발생된 $6\~12\;MeV$ 에너지의 전자선을 이용하였으며 선량측정은 평행평판형 전리상(Markus chamber, PTW 23343)을 조직등가 팬텀(Polystyrene)에 삽입하여 측정하였다. 전자산란선의 에너지분포는 Monte Carlo (EGS4) 계산으로 예측하였으며 조직내 선량분포는 필름 흑화도(X-Omat V, Wellhofer 700i)에 의하여 측정하였다. 결과 : 전자선 입사에너지가 6 MeV일 때 전자산란선의 평균 에너지는 약 1.5 MeV 이었으며 산란각이 클수록 에너지는 줄어들었다. 입사 전자선 에너지 6 MeV 에서 산란판의 각도 $30^{\circ},\;45^{\circ}$ 에 따른 최대선량지점은 산란선 방출구의 중심에서 각각 5 mm 및 -10 mm지점의 표면에서 발생되며 입사전자선에 대한 전자산란선의 선량비는 약 $8.5\%$ 내외로 측정되었다. 입사전자선에너지 6 MeV에서 산란판각도 $45^{\circ},\;60^{\circ}$에 의한 $50\%$의 심부선량분포는 각각 6 mm와 7 mm 깊이에 도달하였으며 입사에너지 증가에 비례하였다. 결론 : 전자선 후방산란의 특성을 연구하고 이를 인체 강내 측방 점막부위에 발생한 종양을 효과적으로 치료할 수 있는 강내 전자산란선 조사통을 고안 제작 하였다. 시험용으로 제작한 전자산란선 조사기구를 이용하여 전자선 에너지와 산란판의 각도에 따른 산란선의 선량비율과 심부율을 측정하였다. 구강, 자궁, 직장 등 강내측벽 점막 등에 발생된 악성종양의 모양과 깊이에 가장 적당한 입사 에너지, 산란판의 각도, 산란창구 및 조사각도를 선택함으로서 방사선치료방법을 향상시킬 수 있을 것이라고 기대된다.

  • PDF

발아증진 및 소독을 위한 물리적 방법을 이용한 종자처리 기술 (Physical Seed Treatment Techniques for Germination Enrichment and Seed Sterilization)

  • 강시용
    • 방사선산업학회지
    • /
    • 제17권2호
    • /
    • pp.199-207
    • /
    • 2023
  • Since seeds can be directly used as food resources as well as for crop cultivation or preservation of genetic resources, it is essential to develop high-quality seed processing technology to increase agricultural productivity. Seed treatment means processing technologies of seeds through physical or chemical treatment processes from after harvesting seeds to before sowing of seeds to improve germination and growth rate, durability, and immunity, etc. Since chemical seed treatment technology using pesticides or plant growth regulators has problems of environmental pollution and human toxicity, it is desired to develop an alternative technology. As a physical seed treatment method, various technologies such as ionizing radiation, plasma, microwave, and magnetic field are being developed, and some of them are being used practically. In this paper, I will summarize the mechanism of seed priming and disinfection, and the advantages and disadvantages of application, focusing on these physical seed treatment methods. Low dose or moderate intensity ionizing radiation, microwave, low-temperature plasma, and magnetic field treatments often promoted seed germination and seedling growth. However, effective removal of direct seed pathogens at these treatment intensities appears to be difficult. And it has been shown that relatively high-dose electron beam treatment using low-energy electron beams kills microorganisms on the seed surface and hull layer while not damaging the inner tissue of the seed, and is also effectively used for seed treatment on a commercial scale. In order to put the physical seed treatment technology to practical use in Korea, it is necessary to develop an economical scale treatment device along with the development of individual treatment technology to each crop.

투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰 (Study on Radiation dose in according to Magnification's rate in fluoroscopy)

  • 강경미;홍선숙;성민숙;손운흥
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.39-44
    • /
    • 2013
  • Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy.

  • PDF

선형가속기의 선량율에 따른 쐐기필터의 선량분포 (Dose Distribution of Wedge filter by Dose Rate in LINAC)

  • 권태형;김승욱;윤용학;원도연;정경환;정재은;조준호
    • 한국방사선학회논문지
    • /
    • 제9권5호
    • /
    • pp.323-329
    • /
    • 2015
  • 이 연구는 금속쐐기필터를 대신하여 동적쐐기필터를 사용할 수 있을지에 대한 적정성 평가에 관한 것이다. 선형가속기에서 발생되는 엑스선 에너지는 6 MV, 10 MV로 상용화되어있다. 금속쐐기필터의 $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$에 각각 100, 200, 300, 400, 500, 600 선량율(MU/min)로 48번 조사하였고, 동적쐐기필터와의 비교를 위해 같은 조건으로 총 96번 조사하였다. 측정조건은 선원필름간 거리 100cm, 조사면 $10{\times}10cm$ 로 측정하였다. 현상된 필름을 스캔하여 선량분석프로그램으로 교정 후 분석하였고, 표준편차를 구해 선량율을 비교하였다. 동적쐐기필터는 선량, 산란선 및 치료시간을 감소시키며, 환자에 조사되는 선량이 적어 매우 유용하다. 동일한 조건에서 선량율에 따른 오차는 연관성이 없으므로 환자의 상황에 따라 고선량율의 치료를 사용하는 것도 가능할 것으로 생각된다.

에폭시수지계 중성자 차폐재의 제조 및 방사선 차폐능 평가 (Fabrication and Evaluation of Radiation Shielding Property of Epoxy Resin-Type Neutron Shielding Materials)

  • 조수행;윤정현;최병일;도재범;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제22권2호
    • /
    • pp.77-83
    • /
    • 1997
  • 사용 후 핵연료 수송용기 등에 사용되는 에폭시수지계 중성자 차폐재, KNS(Kaeri Neutron Shield)-101, KNS-102 및 KNS-103를 제조하였다. 기본물질은 에폭시수지이며, 첨가제로는 폴리프로필렌, 수산화알루미늄 및 탄화붕소이다. 이들 중성자 차폐재들은 유동성이 좋아 수송용기와 같은 복잡한 구조에 사용할 수 있다. 제조된 중성자 차폐재들을 가압경수로 사용 후 핵연료 28다발을 수송할 수 있는 수송용기에 적용하여 차폐능 평가를 수행하였다. 세가지 중성자 차폐재를 수송용기에 적용하여 ANISN 코드로 차폐능 평가를 수행한 결과 정상수송시 중성자 차폐재의 두께가 10 cm 이상 일때 수송용기 반경방향표면에서 최대 방사선량율은 $300{\mu}Sv/h$로 나타났으며, 수송용기 표면에서 100 cm 지점에서의 최대 방사선량율은 $97{\mu}Sv/h$로 나타났다. 이들은 모두 관련된 법규들에서 규정된 최대허용 방사선량율을 만족하는 것으로 나타났다.

  • PDF

흉곽(胸廓)의 전자선(電子線) 조사시(照射時) 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on Electron Beam Dosimetry for Chest Wall Irradiation)

  • 강위생;고경환;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.41-45
    • /
    • 1983
  • To obtain 7 MeV electron beam which is suitable for treatment of the chest wall after radical of modified radical mastectomy, the authors reduced the energy of electron beam by means by Lucite plate inserted in the beam. To determine the proper thickness of the Lucite plate necessary to reduce the energy of 9 MeV electron beam to 6 MeV, dosimetry was made by using a parallel plate ionization chamber in polystyrene phantom. Separation between two adjacent fields, 7 MeV for chest wall and 12 MeV for internal mammary region, was studied by means of film dosimetry in both polytyrene phantom and Humanoid phantom. The results were as follows. 1. The average energy of 9 MeV electron beam transmitted through the Lucite plate was reduced. Reduction was proportional to the thickness of the Lucite plate in the rate of 1.7 MeV/cm. 2. The proper thickness of the Lucite plate necessary to obtain 6 MeV electron beam from 9 MeV was 1.2 cm. 3. 7 MeV electron beam, 80% dose at 2cm depth, is adequate for treatment of the chest wall. 4. Proper separation between two adjacent electron fields, 7 MeV and 12 MeV, was 5mm on both flat surface and sloping surface to produce uniform dose distribution.

  • PDF

Radiation Grafting of Flame Retardant to Polyester/Cotton Blend

  • Kong, Young-Kun;Chang, Hun-Sun;Lee, Jong-Kwang;Park, Jai-Ho
    • Nuclear Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 1980
  • 고선량율 전자가속기를 이용하여 폴리에스터/면혼방직포에 난연제 (Fyrol 76)를 그래프트 중합반응 시키는 방법의 개선을 시도하였다. 폴리에스터/면(65/35) 혼방직포에 고착시킨 난연제는 Fyrol 76을 사용하였다. 팽윤조건과 단위체와 접촉시간 및 선량율 등을 적절히 조절하므로써 섬유체 난연제를 그래프트 반응시킬 수 있었으며, 그래프트 중합반응의 수율은 방사선 선창과 선팽윤(先膨潤) 조건에 좌우되었다. 난연제로 처리한 혼방직포의 난연성 효과는 산소 지수로 측정하였다. 폴리에스터/면혼방직포에 난연제를 그래프트 중합반응 시키는 방법으로 종래에는 고온에서 두단계를 거쳐 실시하는 것이었으나 본 연구를 통하여 실온에서 단 단계로 처리토록 하는 방법을 개선하였다.

  • PDF

전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구 (The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy)

  • 박시온;곽근탁;박주경;이승훈;김양수;김정수;권형철;이선영
    • 대한방사선치료학회지
    • /
    • 제31권1호
    • /
    • pp.57-65
    • /
    • 2019
  • 목 적: 전자선 치료에서 저 용융점 납합금과 순수 납을 이용한 차폐 시 두께증가에 따른 블록 가장자리의 산란선 영향을 알아보고자 한다. 대상 및 방법: $10{\times}10cm^2$ 어플리케이터의 Insert Frame 절반을 차폐하도록 블록을 제작하였고, 두께는 각 재질당 3, 5, 10, 15, 20 (mm)로 하였다. 공통 조건을 에너지 6 MeV, 선량률 300 MU/Min, 갠트리 각도 0, 부여선량 100 MU으로 설정하였고, 블록의 위치와 측정점의 위치, 블록재질을 각각 달리하여 블록 두께증가에 따른 상대적인 산란비율을 평행평판형 전리함과 고체팬텀으로 측정하였다. 결 과: (측정 깊이 / 블록 위치 / 블록 재질)이 (표면 / 어플리케이터 / 순수 납)일 때 블록 두께가 3, 5, 10, 15, 20 (mm) 순으로 증가함에 따라 상대선량은 15.33 nC, 15.28 nC, 15.08 nC, 15.05 nC, 15.07 nC로 측정되었다. (표면 / 어플리케이터 / 합금 납)일 때 15.19 nC, 15.25 nC, 15.15 nC, 14.96 nC, 15.15 nC로 측정되었다. (표면 / 팬텀 위 / 순수 납)일 때 15.62 nC, 15.59 nC, 15.53 nC, 15.48 nC, 15.34 nC로 측정되었다. (표면 / 팬텀 위 / 합금 납)일 때 15.56 nC, 15.55 nC, 15.51 nC, 15.42 nC, 15.39 nC로 측정되었다. (심부 / 어플리케이터 / 순수 납)일 때 16.70 nC, 16.84 nC, 16.72 nC, 16.88 nC, 16.90 nC로 측정되었다. (심부 / 어플리케이터 / 합금 납)일 때 16.83 nC, 17.12 nC, 16.89 nC, 16.77 nC, 16.52 nC로 측정되었다. (심부 / 팬텀 위 / 순수 납)일 때 17.41 nC, 17.45 nC, 17.34 nC, 17.42 nC, 17.25 nC로 측정되었다. (심부 / 팬텀 위 / 합금 납)일 때 17.45 nC, 17.44 nC, 17.47 nC, 17.43 nC, 17.35 nC로 측정되었다. 결 론: 차폐블록을 이용하여 전자선 치료를 진행할 때 블록위치는 환자 체표면보다는 어플리케이터에 삽입하고 두께는 각 사용 에너지에 해당되는 최소 적정차폐두께로 제작해야 한다. 또한 블록 가장자리 경계선으로부터 떨어진 거리에 따라 변화하는 산란선의 영향을 충분히 고려하여 치료를 시행하는 것이 바람직하다고 사료된다.