• 제목/요약/키워드: Surface leakage

검색결과 776건 처리시간 0.026초

In-situ spectroscopic studies of SOFC cathode materials

  • 주종훈
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.70.1-70.1
    • /
    • 2012
  • In-situ X-ray photoelectron spectroscopy (XPS) and infrared (IR) spectroscopy studies of SOFC cathode materials will be discussed in this presentation. The mixed conducting perovskites (ABO3) containing rare and alkaline earth metals on the A-site and a transition metal on the B-site are commonly used as cathodes for solid oxide fuel cells (SOFC). However, the details of the oxygen reduction reaction are still not clearly understood. The information about the type of adsorbed oxygen species and their concentration is important for a mechanistic understanding of the oxygen incorporation into these cathode materials. XPS has been widely used for the analysis of adsorbed species and surface structure. However, the conventional XPS experiments have the severe drawback to operate at room temperature and with the sample under ultrahigh vacuum (UHV) conditions, which is far from the relevant conditions of SOFC operation. The disadvantages of conventional XPS can be overcome to a large extent with a "high pressure" XPS setup installed at the BESSY II synchrotron. It allows sample depth profiling over 2 nm without sputtering by variation of the excitation energy, and most importantly measurements under a residual gas pressure in the mbar range. It is also well known that the catalytic activity for the oxygen reduction is very sensitive to their electrical conductivity and oxygen nonstoichiometry. Although the electrical conductivity of perovskite oxides has been intensively studied as a function of temperature or oxygen partial pressure (Po2), in-situ measurements of the conductivity of these materials in contact with the electrolyte as a SOFC configuration have little been reported. In order to measure the in-plane conductivity of an electrode film on the electrolyte, a substrate with high resistance is required for excluding the leakage current of the substrate. It is also hardly possible to measure the conductivity of cracked thin film by electrical methods. In this study, we report the electrical conductivity of perovskite $La_{0.6}Sr_{0.4}CoO_{3-{\delta}}$ (LSC) thin films on yttria-stabilized zirconia (YSZ) electrolyte quantitatively obtained by in-situ IR spectroscopy. This method enables a reliable measurement of the electronic conductivity of the electrodes as part of the SOFC configuration regardless of leakage current to the substrate and cracks in the film.

  • PDF

Phase Evolution Behavior of (Bi,Nd)(Fe,Ti)$O_3$ Ceramics and Thin Films

  • Kim, Kyung-Man;Byun, Seung-Hyun;Yang, Pan;Lee, Yoon-Ho;Lee, Jai-Yeoul;Lee, Hee-Young
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.331-332
    • /
    • 2008
  • Couplings between electric, magnetic, and structural order parameters result in the so-called multiferroic phenomena with two or more ferroic phenomena such as ferroelectricity, ferromagnetism, or ferroelasticity. The simultaneous ferroelectricity and ferromagnetism (magnetoelectricity) permits potential applications in information storage, spintronics, and magnetic or electric field sensors. The perovskite BiFeO3(BFO) is known to be antiferromagnetic below the Neel temperature of 647K and ferroelectric with a high Curie temperature of 1043K. It exhibits weak magnetism at room temperature due to the residual moment from a canted spin structure. It is likely that non-stoichiometry and second-phase formation are the factors responsible for leakage current in BFO. It has been suggested that oxygen non-stoichiometry leads to valence fluctuations of Fe ions in BFO, resulting in high conductivity. To reduce the large leakage current of BFO, one attempt is to make donor-doped BFO compounds and thin films. In this study, (Bi1-x,Ndx)(Fe1-y,Tiy)O3 thin films have been deposited on Pt(111)/TiO2/SiO2/Si substrates by pulsed laser deposition. The effect of dopants on the phase evolution and surface morphology are analyzed. Furthermore, electrical and magnetic properties are measured and their coupling characteristics are discussed.

  • PDF

LPI 인젝터의 성능 및 내구성 개선에 관한 연구 (A Study on Performance Improvement in Durability and Reliability of LPi Injector)

  • 박철웅;김창업;최교남;백승국;신문성
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.38-44
    • /
    • 2012
  • 근래 들어 강화되는 배출가스 규제에 대응하기 위한 대책으로 LPG 차량에 적용되고 있는 제3세대 LPG 연료공급방식인 LPi(Liquid phase LPG injection)는 펌프를 이용해서 고압의 액상연료를 공급하는 것이 가장 핵심적인 기술이다. LPi 시스템은 액상연료분사의 전자식 정밀제어를 통해 출력이 상승하고 유해배출가스가 현저하게 저감되는 장점이 있으나, 가장 핵심적인 부품인 연료펌프 및 인젝터의 경우 대부분 수입에 의존하고 있어 시스템 설계에 유연하지 못하다. 본 연구에서는 인젝터의 국산화 개발을 위해 LPi 시스템에 적합한 연료공급방법의 인젝터 디자인 및 최적의 작동조건 확보를 목표로 LPi용 인젝터의 설계 및 시작품을 제작하여 누설 및 유량특성을 살펴보았다.

4H-SiC기판 위에 Aerosol Deposition으로 증착된 Al2O3박막의 후열처리 효과 (Post Annealing Effect on the Characteristics of Al2O3 Thin Films Deposited by Aerosol Deposition on 4H-SiC)

  • 유수산나;강민석;김홍기;이영희;구상모
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.486-490
    • /
    • 2014
  • $Al_2O_3$ films on silicon carbide were fabricated by Aerosol deposition with annealing temperature at $800^{\circ}C$ and $1,000^{\circ}C$. The effect of thermal treatment on physical properties of $Al_2O_3$ thin films has been investigated by XRD (X-ray diffraction), AFM (atomic force microscope), SEM (scanning electron microscope), and AES (auger electron spectroscopy). Also electrical properties have been investigated by Keithley 4,200 semiconductor parameter analyzer to explain the interface trapped charge density ($D_{it}$), flatband voltage ($V_{FB}$) and leakage current ($I_o$). $Al_2O_3$ films become crystallized with increasing temperature by calculating full width at half maximum (FWHM) of diffraction peaks, also surface morphology is observed by topography measurement in non-contact mode AFM. $D_{it}$ was $2.26{\times}10^{-12}eV^{-1}.cm^{-2}$ at $800^{\circ}C$ annealed sample, which is the lowest value in all samples. Also the sample annealed at $800^{\circ}C$ has the lowest leakage current of $4.89{\times}10^{-13}A$.

광중합형 충전용 글라스 아이오노머 시멘트의 상아질 변연누출에 관한 정량분석 (DENTINAL MICROLEAKAGE STUDY ON THE LIGHT CURABLE RESTORATIVE GLASS IONOMER CEMENT)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.832-838
    • /
    • 1995
  • The purpose of this study was to evaluate the amount of marginal microleakage of 2 light curable GI cements(Fuji II LC & VariGlass), which contain some resin components. 4 volunteers kept on acrylic resin plates, which contained dentin disks with cavities filled with test materials for 2 weeks. The time when polishing was done(5 minutes and 24 hours after filling) and the use of protective agents were varied, so 8 groups with each 6 specimens were tested. After having specimens(disks with cavities filled with materials) penetrated with 1% Methylene Blue solution, specimens were stored in 40% nitric acid solution for 4 days to extract adsorbed dye material. Supernatants of centrifuged samples were diluted 5 times and Spectrophotometer was used to determine the degree of absorption. Dye concentration was calculated through the pre-obtained Linear Regression Curve. The results were as follows. 1. The best result was seen in groups (PF24, PV24) which were protected and polished 24 hours later and the opposite phenomenon was seen in groups(NF24, NV24) which were held without protection and polished 24 hours later. Groups polished S minutes later showed moderate leakage pattern. 2. Groups polished 5 minutes later showed similar leakage amount irrespective of using of protective agent. But statistically insignificant lower values were seen in VariGlass than in Fuji II LC groups, So It was considered that VariGlass may be more resistant to early moisture attack than Fuji II LC. 3. In groups polished 24 hours later, there was no significant difference between materials but was definitely significant difference according to the use of protective agent. If the cement in which polishing will be done 24 hours later, Protective agent should be used to cover the surface.

  • PDF

A Study on Unsaturated Zone Characterization and Feasibility of Soil Vapor Extraction at a DNAPL-contaminated Site in Korea

  • Lee, Man Na Mi;Yeo, In Wook
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.48-55
    • /
    • 2013
  • This study aimed at characterizing unsaturated zone at the source zone area contaminated by DNAPL and investigating feasibility of soil vapor extraction (SVE). Five boreholes with three multi-level screens at the depth of 3.0~4.5 m, 5.5~7.0 m, and 8.0~12.0 m were installed at the source zone. Pneumatic tests were performed to determine the permeability of porous medium. Permeability was estimated to be 81.6 to 203.7 darcy, depending on the applied solutions, which was contradicted by grain size analysis of cored soil samples leading to 3.51 darcy. This is due to air flow through gravel pack during the early stage of pneumatic test. Pressure-drawdown curve in the late stage also well showed the leaky aquifer type, indicating air leakage to the ground. Air flow tests were also carried out to investigate air flow connectivity between multi-level wells, indicating that the horizontal air flow was well developed between the lower screens of the wells, not between the upper and middle screens due to the leakage to the surface. For the SVE test, there was no noticeable variation in TCE vapor concentration between three different test runs: 1. 8 hours daily for 5 days, 2. 24 hours together with air blowing at another well (BH1), 3. five consecutive days. Even for five-day consecutive test, total amount of removed TCE was estimated only to be as low as 46.5 g.

Fundamental evaluation of hydrogen behavior in sodium for sodium-water reaction detection of sodium-cooled fast reactor

  • Tomohiko Yamamoto;Atsushi Kato;Masato Hayakawa;Kazuhito Shimoyama;Kuniaki Ara;Nozomu Hatakeyama;Kanau Yamauchi;Yuhei Eda;Masahiro Yui
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.893-899
    • /
    • 2024
  • In a secondary cooling system of a sodium-cooled fast reactor (SFR), rapid detection of hydrogen due to sodium-water reaction (SWR) caused by water leakage from a heat exchanger tube of a steam generator (SG) is important in terms of safety and property protection of the SFR. For hydrogen detection, the hydrogen detectors using atomic transmission phenomenon of hydrogen within Ni-membrane were used in Japanese proto-type SFR "Monju". However, during the plant operation, detection signals of water leakage were observed even in the situation without SWR concerning temperature up and down in the cooling system. For this reason, the study of a new hydrogen detector has been carried out to improve stability, accuracy and reliability. In this research, the authors focus on the difference in composition of hydrogen and the difference between the background hydrogen under normal plant operation and the one generated by SWR and theoretically estimate the hydrogen behavior in liquid sodium by using ultra-accelerated quantum chemical molecular dynamics (UA-QCMD). Based on the estimation, dissolved H or NaH, rather than molecular hydrogen (H2), is the predominant form of the background hydrogen in liquid sodium in terms of energetical stability. On the other hand, it was found that hydrogen molecules produced by the sodium-water reaction can exist stably as a form of a fine bubble concerning some confinement mechanism such as a NaH layer on their surface. At the same time, we observed experimentally that the fine H2 bubbles exist stably in the liquid sodium, longer than previously expected. This paper describes the comparison between the theoretical estimation and experimental results based on hydrogen form in sodium in the development of the new hydrogen detector in Japan.

표면반발경도 활용 콘크리트 동해손상 판정법의 현장 적용 적정성 검토 (Review of Adequacy for On-Site Application of Concrete Freeze-Thaw Damage Evaluation Method Using Surface Rebound Value)

  • 박지선;이종석
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.539-546
    • /
    • 2022
  • 현행 시설물의 안전 및 유지관리 실시 세부지침(성능평가 편)에서는 표면부 콘크리트의 품질의 평가 수단으로 표면에 품질의 저하가 없는 건전부와 겨울철 우수나 누수 등으로 표면 손상이 발생한 비건전부에 대한 표면반발경도를 측정하고 측정값을 상대비교하여 손상도를 평가하도록 규정하고 있다. 그러나 이 판정법은 동결융해 촉진 모사환경으로부터 구한 실험 DB로 도출된 상관관계를 분석하여 제안한 방법으로 실제 현장에서 수집된 DB와 비교 검토하는 등의 현장 적용성에 대한 검토가 미흡한 채 제정되었다. 따라서 이 연구에서는 국내 21개 콘크리트 교량을 대상으로 현장 조사를 실시하고 현장 적용의 적정성을 분석하였다. 분석 결과로부터 동해 손상에 따른 건전부와 비건전부의 뚜렷한 표면반발경도의 차이를 확인할 수 있어 현행 판정법의 현장 적용이 적정함을 확인할 수 있었다. 뿐만 아니라 표면 반발경도의 측정 위치 및 방법의 구체적인 제시에 대한 필요성을 제안하고, 전체 교량을 대상으로 할 때 동해 판정 등급에 대한 유효성에 대하여도 분석하였다.

가상생산 및 실험을 통한 폴리에틸렌관과 금속관 일체형 볼 밸브의 개발에 관한 연구 (A Study on the Development of Unified Ball Valve and Polyethylene-Steel Pipe Via Virtual Manufacturing and Experimental Approach)

  • 서영성;유제혁;지민욱;송정현;이재윤
    • 한국가스학회지
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 2010
  • 가스 파이프의 배관 작업 중 작업 공정 수 및 단가를 낮추는 방법으로 PE관과 강관 일체형 볼 밸브를 개발하였다. 이를 위하여 먼저 유한요소해석을 근간으로 한 가상생산 지원 설계를 수행하여 누설에 대한 안전성을 갖는 프로토타입 제품 설계안을 제시하고, 이를 검증하기 위하여 누설 시험을 병행하는 통합적인 방법을 취하였다. 다양한 설계 모델을 대상으로 내압에 대한 접촉해석을 수행하여 제안된 최종설계안으로부터, 여름(${\Delta}T\;=\;60^{\circ}C$)과 겨울(${\Delta}T\;=\;-50^{\circ}C$)의 과장된 온도의 변화조건에도 비교적 광범위한 부분에서 최대 접촉압력이 각각 71 MPa, 및 8.1 MPa을 유지할 것을 예측하였다. 최종설계안을 바탕으로 시제품을 만들어, 열간 내압크리프 시험을 수행하였으며 사용압력(0.25 MPa)보다 훨씬 높은 가압조건(54 MPa)에서도 기밀을 유지하는 것을 확인하였다.

운영중인 지하구조물 누수처리를 위한 유도배수공법 개발 및 성능 검증 (Development and performance verification of induced drainage method for leakage treatment in existing underground structures)

  • 김동규;임민진
    • 한국터널지하공간학회 논문집
    • /
    • 제19권3호
    • /
    • pp.533-549
    • /
    • 2017
  • 본 연구에서는 지하 콘크리트 구조물 내로 누수된 지하수를 유도하여 배수하는 유도배수공법을 제시하였다. 유도배수공법은 유도배수판, 철망, 고정핀, 광물질 혼입 모르타르로 구성된다. 시공성 향상을 위하여 유도배수판 및 철망은 공압타카와 고정핀를 사용하여 콘크리트 표면에 부착하였다. 고로슬래그미분말을 30% 혼입한 모르타르는 뿜어 붙임 모르타르 장비를 사용하여 유도배수판 및 철망 표면에 타설하였다. 유도배수공법의 현장 시공성 및 성능 검증을 위하여 재래식 콘크리트라이닝 터널과 콘크리트 옹벽에서 시험시공을 수행하였다. 시험시공 완료 3년 후 유도배수공법은 성능저하의 문제점이 없는 것으로 판단되었다. 재령 14일과 3년에 뿜어 붙임 모르타르의 부착력 실험을 수행하였다. 유도배수판 표면에 철망을 적용한 경우 뿜어 붙인 모르타르의 부착력은 재령 14일에 1.04 MPa, 재령 3년에 1.46 MPa로 측정되었다. 철망을 적용하지 않은 경우의 부착력은 재령 14일에 1.13 MPa로 측정되었지만, 재령 3년에는 0.89 MPa로 기준 부착력 1 MPa보다 낮게 측정되었다.