• 제목/요약/키워드: Surface leakage

검색결과 776건 처리시간 0.022초

임의로 거칠게한 표면의 점성 마찰특성 (Characteristics of Friction Factor for Artificially Roughened Surfaces)

  • 하태웅;주영찬;이용복;김창호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.465-470
    • /
    • 2002
  • For measuring friction-factor of artificially-roughened surfaces which are usually applied on damper seals, flat plate test apparatus is designed and fabricated. the measurement of leakage and pressure distribution through round-hole pattern specimen with different hole area is described and a method is discussed for determining the friction-factor experimentally. Results show that the friction-factor of the round-hole pattern surfaces is bigger than that of smooth surface and increases as increasing the hole area. A empirical friction factor model for round-hole pattern surface is defined as the Moody's friction factor formula.

  • PDF

배전용 폴리머애자의 현장열화 특성평가 (Characterization of Field-Aged Polymer Insulators for Distribution Power Systems)

  • 이병성;김찬영;한재홍
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF

연면 트래킹에 의한 탄화 거동 (Carbonization Behavior due to Surface Tracking)

  • 정연하;장태준;손길목;노영수;곽희로
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.28-33
    • /
    • 2007
  • 본 논문에서 전극간 표면누설에 의한 탄화도전로의 형성과 방향성에 대해 연구하였다. 표면에서 트래킹의 특성은 노출된 충전부사이에서 절연파괴되었다. 고속카메라시스템을 이용하여 전극간 방전과 지락, on/off 서어지에서 발생되는 아크성장 메커니즘을 촬영하고, 결과를 분석하였다. 향후 아크제어를 통한 에너지 이용기술의 적용이 기대된다.

콘크리트 구조물에 사용되는 개량아스팔트 시트와 아스팔트 매스틱을 복합화한 방수공법의 누유현상 원인 분석 (Analysis on the Causes of the Oil Leakage Phenomenon for Complex Waterproofing Methods of Asphalt Mastic and Modified Asphalt Sheet)

  • 박진상;김동범;박완구;오상근
    • 한국건축시공학회지
    • /
    • 제18권4호
    • /
    • pp.337-345
    • /
    • 2018
  • 본 연구에서는 누유 현상에 대한 원인 파악을 위하여 실제 현장에서 누유된 시료를 채취하여 육안 관찰을 실시한 결과, 표면 상태의 변화를 근거로 누유 현상 원인이 "구성 성분간 분리"로 판단하고, 이에 대한 검증을 실시하였다. 검증을 위하여 현장에서 많이 사용되고 있는 아스팔트 매스틱 도막재 3개 제품을 수직 실린더에 채워 $50{\pm}5^{\circ}C$의 챔버 속에 정치시킨 후, 1일부터 28일간 매일 실린더의 상부, 하부 재료를 대상으로 Filler 함량차를 측정하여, 변화율을 비교 분석하였다. 평가 결과, 정치 시일이 경과할수록 아스팔트 매스틱의 Filler 성분이 침강되는 분리현상을 확인할 수 있었으며, 정치 후 28일에는 상부와 하부 시료의 Filler 함량이 최대 23.8% 이상 차이가 나는 것을 확인할 수 있었다. 상기 결과를 근거로 아스팔트 매스틱의 누유 발생 메커니즘에 대한 가설 수립 후 누유발생 전 과정에 대한 예측 모델을 제시하였다.

DLC-coated Si-tip FEA 제조에 있어서 Al 희생층을 이용한 게이트 누설 전류의 감소 (Decrease of Gate Leakage Current by Employing AI Sacrificial Layer in the DLC-coated Si-tip FEA Fabrication)

  • 주병권;이상조;김훈;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권8호
    • /
    • pp.577-579
    • /
    • 1999
  • DLC film remaining on device surface could be removed by eliminating AI sacrificial layer as a final step of lift-off process in the fabrication of DLC-coated Si-tip FEA. The field emission properties(I-V curves, hysteresis, and current fluctuation etc.) of the processed device were analyzed and the process was employed to 1.76 inch-sized FEA panel fabrication in order to evaluate its FED applicability.

  • PDF

금속 표면에서 누전 판단을 위한 자속 분포의 해석 (An Analysis of Magnetic Flux Distribution for Deciding an Electric Leakage at the Metal Surface)

  • 박건호
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2013년도 제47차 동계학술대회논문집 21권1호
    • /
    • pp.257-258
    • /
    • 2013
  • 본 연구에서는 피복 손상으로 주변 도전체를 통해 누전되었을 때 그 주변의 자장을 검출하여 누전 여부를 판단할 수 있는 장치개발을 하기 위하여 우선 표면 누전에 의한 전류의 흐름을 조사하고, 전류에 의한 자장을 검출하기 위해 센서를 제작한다. 코어는 요크 타입을 적용하였으며, 코일은 0.5[mm] 동선을 4,000회 감았다. 실험 환경은 전선 피복 손상에 의한 금속 표면에 누전되는 상황을 모의하였으며, 부하는 40[W], 400[W], 1,400[W]를 적용하였다. 센서는 표면에 발생되는 자장을 검출할 수 있도록 2축으로 구성하였으며, 전선 주변 및 누전된 금속 표면에서 거리 및 각도 변화에 따른 자장을 검출하였다.

  • PDF

Leakage Current Reduction of Ni-MILC Poly-Si TFT Using Chemical Cleaning Method

  • Lee, Kwang-Jin;Kim, Doyeon;Choi, Duck-Kyun;Kim, Woo-Byoung
    • 한국재료학회지
    • /
    • 제28권8호
    • /
    • pp.440-444
    • /
    • 2018
  • An effective cleaning method for Ni removal in Ni-induced lateral crystallization(Ni-MILC) poly-Si TFTs and their electrical properties are investigated. The HCN cleaning method is effective for removal of Ni on the crystallized Si surface, while the nitric acid treatment results decrease by almost two orders of magnitude in the Ni concentration due to effective removal of diffused Ni mainly in the poly-Si grain boundary regions. Using the HCN cleaning method after the nitric acid treatment, re-adsorbed Ni on the Si surfaces is effectively removed by the formation of Ni-cyanide complexions. After the cleaning process, important electrical properties are improved, e.g., the leakage current density from $9.43{\times}10^{-12}$ to $3.43{\times}10^{-12}$ A and the subthreshold swing values from 1.37 to 0.67 mV/dec.

옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석 (The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door)

  • 문중섭;서광석;김정호;이재형;송우창;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

MeV 이온주입에 의한 Retrograde Triple-well 형성시 발생하는 결합제어 (Control of Defect Produced in a Retrograde Triple Well Using MeV Ion Implantation)

  • 정희석;고무순;김대영;류한권;노재상
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.17-20
    • /
    • 2000
  • This study is about a retrograde triple well employed in the Cell tr. of next DRAM and flash memory. triple well structure is formed deep n-well under the light p-well using MeV ion implantation. MeV P implanted deep n-well was observed to show greatly improved characteristics of electrical isolation and soft error. Junction leakage current, however, showed a critical behavior as a function of implantation and annealing conditions. {311} defects were observed to be responsible for the leakage current. {311} defects were generated near the R$\sub$p/ (projected range) region and grown upward to the surface during annealing. This is study on the defect behavior in device region as a function of implantation and annealing conditions.

  • PDF

염수에 의해 열화된 누전차단기 절연재료의 특성에 관한 연구 (A Study on the Characteristics of ELB Insulating Material deteriorated by Salt water)

  • 김형래;김동욱;김혁수;최충석;김훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.878-881
    • /
    • 2001
  • In this paper, we analyzed the characteristics of insulating material with ELB(earth leakage circuit breaker) through tracking experiment and the study was carried out three different types of samples. The tracking is breakdown phenomenon of material surface that is generated on the organic insulating material. The test method applied IEC publication 587. The result of the sample breakdown by tracking was carbonized and resistance of between the electrodes is approximately 300$\Omega$. In the result of DSC analysis, the caloric peak was detected before 100$^{\circ}C$ in product of tracking. It appeared weight loss of 10.87% at 537$^{\circ}C$ on TGA. IR spectrum analysis showed carbon-hydrogen(C-H)bond on molecular structure that is the sample of tracking.

  • PDF