• Title/Summary/Keyword: Surface hydration

Search Result 253, Processing Time 0.026 seconds

SAMs of 2-Aminoethanethiol Modified with 3,4-Dihydroxyphenylalanine for the Electrocatalytic Oxidation of NADH on Gold Electrodes

  • Cha, Seong-Keuck
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.786-790
    • /
    • 2004
  • 2-Aminoethanethiol (aet) has been used to make self-assembled monolayer (SAMs) on gold electrodes, which are subsequently modified with 3,4-dihydroxy phenylalanine (dpa). Such modified electrodes having various types of Au/aet-dpa were employed in the electrocatalytic oxidation of NADH. The purpose of this study to characterize the responses of such modified electrodes in terms of the immobilization procedure, pH of the solution and applied potential. The reaction of the surface immobilized dpa with NADH was studied using the rotating disk electrode technique and a value of $2.2{\times}10^4M^{-1}s^{-1}$ was obtained for the second-order rate constant in 0.1 M Tris/$NO_3^-$buffer (pH=8.0). The hydration behavior of the films was characterized by quartz crystal microbalance. When used as a NADH sensor, the Au/aet-dpa electrode exhibited good sensitivity and an excellent correlation (r ${\geq}$ 0.99) for NADH concentration which extended to $3.8{\times}10^{-3}$ M.

Measurement of Changes in Work Function on MgO Protective Layer after H2-plasma Treatment (수소 Plasma 처리 후의 MgO 보호막에 대한 일함수 변화 측정)

  • Jeong, Jae-Cheon;Rhee, Seuk-Joo;Cho, Jae-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.611-614
    • /
    • 2007
  • The changes in the work $function({\Phi}_w)$ in the MgO protective layers after $plasma(Ar,\;H_2)$ treatment have been studied using ${\Upsilon}-focused$ ion beam $({\Upsilon}-FIB)$ system. The ${\Phi}_w$ was determined as follows: Ar-plasma $treatment({\Phi}_w=4.52eV)$, $H_2-plasma$ $treatment({\Phi}_w=5.65eV)$, and non-plasma $treatment({\Phi}_w=4.64eV)$. The results indicated that the H-plasma could not make any effective physical etching due to the small masses of hydrogen atoms and molecules while the hydration of H-plasma could grow some contaminating materials on the surface of MgO.

A Study on the Mix Design and Quality Factors of the Combined High Flowing Concrete Using High Belite Cement

  • Kwon, Yeong-Ho
    • KCI Concrete Journal
    • /
    • v.14 no.3
    • /
    • pp.121-129
    • /
    • 2002
  • This study investigates experimentally into the design factors and quality variations having an effect on the properties of the combined high flowing concrete to be poured in the slurry wall of Inchon LNG in-ground receiving terminal. Especially, high belite cement and lime stone powder as cementitious materials and viscosity agent in order to improve self-compaction and hydration heat are used in this study. Water-cement ratio(W/C), fine aggregate volume ratio(Sr) and coarse aggregate volume ratio(Gv) as design factors of the combined high flowing concrete are applied to determine the optimum mix design proportion. Also quality variations for sensitivity test are selected items as followings. (1)Surface moisture(5cases) and (2)Fineness modulus of fine aggregate(5cases), (3)Concrete temperature(3cases), (4)Specific surface(3cases) and particle size of lime stone powder. As experimental results, water-cement ratio, fine and coarse aggregate volume ratio are shown as the optimum range 51%, 43% and 53% separately considering site condition of slurry wall. Also quality factors by sensitivity test should be controlled in the following ranges. (1) Surface moisture :to.67% and (2)Fineness modulus 2.6$\pm$0.2 of fine aggregate, (3)Concrete temperature l0-20t, (4) Specific surface 6,000$\textrm{cm}^2$/g and particle size 9.7$\pm$1.0${\mu}{\textrm}{m}$ of lime stone powder. Based on the results of this study, the optimum mix design proportion of the combined high flowing concrete are selected and poured successfully in the slurry wall of LNG in-ground tank.

  • PDF

Application of DV-X$\alpha$ Method to ${\gamma}$-2CaO.SiO$_2$

  • Yamaguchi, Norio;Fujimori, Hirotaka;Ioku, Koji;Goto, Seishi;Nakayasu, Tetsuo
    • The Korean Journal of Ceramics
    • /
    • v.6 no.4
    • /
    • pp.339-342
    • /
    • 2000
  • In the present study, we attempted to apply DV-X$\alpha$ method to expressing the reactivity of materials. The expression of reactivity was discussed by comparison between ${\gamma}$-C$_2$G having hydraulic activity and ${\gamma}$-C$_2$S not having hydraulic activity at normal conditions. It was found that the model cluster used for calculation can finely reproduce the bulk and surface states using with and without point charge, respectively. The hydration state was also represented by placing OH ̄ on the surface of the cluster. It was calculated that the bond strength of the first layer (as surface) was bigger than that of inner layers (as bulk) for ${\gamma}$-C$_2$S while that of the first layer for ${\gamma}$-C$_2$G was smaller than that of inner layers. Subsequently a model in which OH ̄ is coordinated on Ca at the surface was also calculated. The bond strength with OH ̄ was stronger than that without OH ̄, while for ${\gamma}$-C$_2$G the bond strength with OH ̄ was weaker than that without OH ̄. From these results, it is concluded that the hydraulic activity depends on whether the bond strength for hydrated state becomes weaker than that unhydrated state or not.

  • PDF

Improvement of Durability and Change of Pore Structure for Concrete Surface by the Penetrative Surface Protection Agent (함침계 표면보호제에 의한 콘크리트 표면의 세공구조 변화 및 내구성 향상)

  • Kang, Suk-Pyo;Kim, Jung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.125-132
    • /
    • 2006
  • Recently, surface finishing and protection materials were developed to restore performance of the deteriorated concrete and inhibiting corrosion of the reinforcing-bar. For this purpose, surface protection agent as well as coatings are used. Coatings have the advantage of low Permeability of $CO_2,\;SO_2$ and water. However, for coatings such as epoxy, urethane and acryl, long-term adhesive strength is reduced and the formed membrane of those is blistered by various causes. Also when organic coatings are applied to the wet surface of concrete, those have a problem with adhesion. On the other hand, surface protection agent penetrates into pore structure in concrete through capillary and cm make a dense micro structure in concrete as a result of filling effect. Furthermore, the chemical reaction between silicate from surface protection agent and cement hydrates can also make a additional hydration product which is ideally compatible with concrete body. The aim of this study is to examine the effect of penetrative surface protection agent(SPA) by evaluating several concrete durability characteristics. The results show that the concrete penetrated surface protection agent exhibited higher durability characteristics for instance, carbonation velocity coefficient, resistance to chemical attack and chloride ion penetration than the plain concrete. These results due to formation of a discontinuous macro-pore system which inhibits deterioration factors of concrete by changed the pore structure(porosity and pore size distributions) of the concrete penetrated surface protection agent.

Study on the Surface Properties of Corneocyte between Face and Forearm Using Atomic Force microscopy (AFM) (AFM을 이용한 얼굴과 하박내측 각질세포 표면 특성 비교연구)

  • Chang, Minyoul
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.4
    • /
    • pp.373-380
    • /
    • 2019
  • There are many differences in tran-epidermal water loss (TEWL), skin water contents, and skin elasticity, etc between face and forearm skin. In particular, our previous studies showed that elasticity of face skin was significantly differed from forearm depending on full hydration. So, we have studied the surface properties of corneocyte using atomic force microscopy (AFM), assuming that the differences between face and forearm skin would be associated with the surface properties of corneocyte. The surface roughness of corneocyte and villus-like projections (VPs) were measured. Furthermore, qualitative comparison among the surface of face, forearm, and lip corneocyte was performed. Corneocytes were collected by tape-stripping on both face and forearm of 8 volunteers, and the bottom surface of corneocytes were measured at 40 ㎛ × 40 ㎛ using AFM. Results showed that the lower surface roughness of face corneocytes was 388.34 ± 86.189 nm, and that of forearm corneocytes was 662.27 ± 224.257 nm, which confirmed that the lower surface of forearm corneocytes was more rough than that of face corneocytes (p < 0.001). Compared with the amount of VPs, lip corneocytes were the highest followed by face corneocytes, and forearm corneocytes were the lowest. From these results, it is conclued that the surface properties of corneocytes are somewhat involved in the property differences between the face and the forearm skin and VPs can be a useful parameter for the study of corneocyte by site. In addition, AFM is a very useful device for the comparative study of nano-structural differences on the surface of corneocytes. More studies can lead to develop a new evaluation method of corneocytes.

Effects of Topical Moisturizers on the Skin of Healthy Full-term Infants and Toddlers (국소 보습제 도포가 정상 영유아 피부에 미치는 영향에 관한 연구)

  • Hyun, Moo Yeol;Lee, Yonghee;Oh, Won Jong;Yoo, Kwang Ho;Park, Kui Young;Kim, Myeung Nam;Hong, Chang Kwun;Kim, Beom Joon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.1
    • /
    • pp.63-71
    • /
    • 2015
  • Moisturizers are the most prescribed products in dermatology. Treatment with moisturizers aims to maintain skin integrity and overall well-being by providing a healthy appearance. Moisturizers perform very important functions in baby care; however, there are few studies on the effects of moisturizers on the skin of infants. To investigate the effects of moisturizers on the skin of healthy full-term infants and toddlers, thirty-one healthy, full-term, 6- to 36-month-old infants and toddlers without any dermatologic conditions received moisturizer applied to the whole body except the eyes and diaper area after bathing twice daily for 4 weeks. Clinical assessments were conducted before treatment, immediately after the treatment period, and 1 and 4 weeks after treatment. At all visits, skin hydration, transepidermal water loss (TEWL), skin pH, and skin roughness were measured, the skin surface was photographed, and any adverse events were recorded. After using moisturizer, skin hydration significantly increased and TEWL and roughness significantly decreased. The skin pH was modified to mildly acidic and the skin surface was visually smoother than before treatment. There were no statistical significant differences of effects of moisturizers according to age and sex, and adverse events were not observed. The results of moisturizer application on the skin were increased skin hydration, recovery of barrier function, balancing skin pH within a mildly acidic range, and increasing the smoothness of the skin surface for 4 weeks.

Field Applicability Evaluation Experiment for Ultra-high Strength (130MPa) Concrete (초고강도(130MPa) 콘크리트의 현장적용성 평가에 관한 실험)

  • Choonhwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.20-31
    • /
    • 2024
  • Purpose: Research and development of high-strength concrete enables high-rise buildings and reduces the self-weight of the structure by reducing the cross-section, thereby reducing the thickness of beams and slabs to build more floors. A large effective space can be secured and the amount of reinforcement and concrete used to designate the base surface can be reduced. Method: In terms of field construction and quality, the effect of reducing the occurrence of drying shrinkage can be confirmed by studying the combination of low water bonding ratio and minimizing bleeding on the concrete surface. Result: The ease of site construction was confirmed due to the high self-charging property due to the increased fluidity by using high-performance water reducing agents, and the advantage of shortening the time to remove the formwork by expressing the early strength of concrete was confirmed. These experimental results show that the field application of ultra-high-strength concrete with a design standard strength of 100 MPa or higher can be expanded in high-rise buildings. Through this study, we experimented and evaluated whether ultra-high-strength concrete with a strength of 130 MPa or higher, considering the applicability of high-rise buildings with more than 120 floors in Korea, could be applied in the field. Conclusion: This study found the optimal mixing ratio studied by various methods of indoor basic experiments to confirm the applicability of ultra-high strength, produced 130MPa ultra-high strength concrete at a ready-mixed concrete factory similar to the real size, and tested the applicability of concrete to the fluidity and strength expression and hydration heat.

Water Repellent Characteristics According to the Surface Properties of Cement Mortar Mixed with Water-soluble Water Wepellent (표면 성상에 따른 수용성 발수제 혼입 시멘트 모르타르의 발수특성)

  • Kang, Suk-Pyo;Kang, Hye-Ju;Hong, Seong-Uk;Yang, Seung-Hyeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.42-49
    • /
    • 2020
  • This paper is a basic study to improve durability by imparting hydrophobicity to the surface and sphere of cement-based materials. A cement mortar to which a silane/siloxane-based mixed water repellent was added was prepared, and its initial hydration performance, flow performance, and compressive strength were measured. In addition, after the surface was abraded, the water contact angle and water absorption were measured. The flow of cement mortar to which the water repellent was added was found to decrease up to 1.5% in the addition amount of the water repellent agent, and increased at 3.0% in the addition amount. It was found that the setting time of the cement paste was delayed in both the initial setting and the termination when the water repellent was added. It was found that the compressive strength decreased from 3.0% of the maximum added amount of the water repellent to a maximum of 30%. The contact angle was found to increase when the water repellent was added to the cement mortar, and the contact angle after surface polishing was found to be larger than before surface polishing. The addition of the water repellent showed hydrophobicity not only on the surface but also on the surface and cross section damaged by polishing. The water absorption rate was found to decrease when the water repellent was added to the cement mortar, and the water absorption rate after surface polishing was found to be greater than before surface polishing.

Effect of Ar+ Ion Irradiation of Polymeric Fiber on Interface and Mechanical Properties of Cementitious Composites

  • Seong, Jin-Wook;Lee, Seung-Hun;Kim, Ki-Hwan;Beag, Young-Whoan;Koh, Seok-Keun;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.6
    • /
    • pp.430-434
    • /
    • 2004
  • The values of fracture energy and mechanical flexural strength of Fiber Reinforced Cement (FRC) with polypropylene (PP) fiber modified by Ion Assisted Reaction (JAR), by which functional groups were grafted on the surface of PP fiber, was improved about 2 times as those of fracture energy and flexural strength of cement reinforced by untreated PP fiber. PP fiber was irradiated in O$_2$ environment by Ar$\^$+/ ion. The contact angle of PP treated by IAR decreased largely when compared with untreated PP. From this result, we expected that surface energy and interfacial adhesion force of treated PP fiber increased. The strain hardening occurred in the strain-stress curve of FRC including PP treated by IAR when compared with that of FRC with untreated PP. These enhanced mechanical properties might be due to strong interaction between hydrophilic group on modified PP fiber and hydroxyl group in cement matrix. This hydrophilic group on surface modified PP fiber was confirmed by XPS analysis. We clearly observed hydration products that were fixed at modified PP fiber due to the strong adhesion force of interface in cement reinforced modified PP by SEM (Scanning Electron Microscopy) study.