• Title/Summary/Keyword: Surface freezing

Search Result 318, Processing Time 0.022 seconds

A Study of Skid Resistance Characteristics by Deicing Chemicals (제설제 사용으로 인한 노면 미끄럼저항 특성 연구)

  • Lee, Seung Woo;Woo, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.813-819
    • /
    • 2006
  • Skid Resistance is a index to represent the friction between tire and road surface, which influences driving safety. Skid resistance varies with the conditions of tire, abrasion of road surface, vehicle speed, drying, wet and freezing condition of road surfaces. Especially, freezing occurs when temperature drops below $0^{\circ}C$ followed by snow or rain causes decrease of skid resistance. To recover the decreased skid resistance deicing work is applied. As a results of deicing works, freezing condition is changed into wet condition. However the wet road surfaces containing the remaining deicings agents may not show the skid resistance of normal wet condition. In this study, skid resistances in the condition of freezing, deicing process and deicing agents remained after snow-removal are evaluated. The test results, skid resistance recover quickly when Pre-wetted salt spreading and NaCl was used as deicing method. Skid resistance of Deicing agents remained on the road surface showed that concrete is higher than asphalt. superior effect. Recovery rate of skid resistance by comparison wet condition is 54~80%.

An experimental study on heat transfer of finned vertical cooling tube (휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究))

  • Song, H.J.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

Accelerated Carbonation of Concrete Deteriorated by Freezing and Thawing (동결융해 작용을 받은 콘크리트의 촉진중성화 특성)

  • Sohn, Yu-Shin;Kim, Gyu-Yong;Kim, Han-June;Park, Chan-Gyu;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.221-224
    • /
    • 2004
  • Several factors of concrete durability decline factor are acted as complex deterioration and is happened not that happen by simplicity deterioration. Specially, in case of sea construction, as complex salt damage, carbonation and freezing & thawing, concrete surface and pore structure is deteriorated. Therefore, analyzing concrete carbonation and pore structure after freezing and thawing test by fresh water and sea water in this research, we wish to study about acceleration of decline of durability and complex deterioration by concrete surface deterioration in sea environment.

  • PDF

Laboratory investigation of unconfined compression behavior of ice and frozen soil mixtures

  • Jin, Hyunwoo;Lee, Jangguen;Zhuang, Li;Ryu, Byung Hyun
    • Geomechanics and Engineering
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 2020
  • Unconfined compression test (UCT) is widely conducted in laboratories to evaluate the mechanical behavior of frozen soils. However, its results are sensitive to the initial conditions of sample creation by freezing as well as the end-surface conditions during loading of the specimen into the apparatus for testing. This work compared ice samples prepared by three-dimensional and one-dimensional freezing. The latter created more-homogenous ice samples containing fewer entrapped air bubbles or air nuclei, leading to relatively stable UCT results. Three end-surface conditions were compared for UCT on ice specimens made by one-dimensional freezing. Steel disc cap with embedded rubber was found most appropriate for UCT. Three frozen materials (ice, frozen sand, and frozen silt) showed different failure patterns, which were classified as brittle failure and ductile failure. Ice and frozen sand showed strain-softening, while frozen silt showed strain-hardening. Subsequent investigation considered the influence of fines content on the unconfined compression behavior of frozen soil mixtures with fines contents of 0-100%. The mixtures showed a brittle-to-ductile transition of failure patterns at 10%-20% fines content.

Freezing of Micro-size Water Droplet on Micro Porous Surface (박판형 미세다공 표면에서의 미소액적의 동결)

  • Park, Chun-Wan;Lee, Dong-Gyu;Peck, Jong-Hyeon;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.173-178
    • /
    • 2011
  • Gas diffusion layer(GDL) in PEMFC performs the discharge of water vapor smoothly. When GDL is revealed to cold environment, the freezing of the water droplet or water net in GDL occurs. The purpose of this work is to observe the cooling and freezing behavior of the water droplet which meets to the microporous surface and air under the various low temperature conditions. GDL was coated with waterproof material, which has three types of coating rate, 0, 40 and 60%. Water droplets in series of sizes on GDL were supercooled, frozen and crystalized orderly by circulating low temperature brine. The process of cooling was investigated with the temperature and the snapshot of the water droplet.

Effect of the Variation of Speccfic Gravity and the Addition of Water Repellent Agent on the Physical Properties of Autoclaved Lightweight Concrete (비중의 변화와 발수제 첨가가 경량기포콘크리트의 물성에 미치는 영향)

  • 노재성;황의환;홍성수;이범재
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • The effcct of specific g~avity cont~olled In the .range fiom O.4 to 0.7 by particle size and added amount of A1 powder in the presence or absence of water repellent agent on the physical properties of ALC was examined to evaluate frost resistance and durability. The compressive sttcngth and the tensile strength are increased and independency with water repellent agent when the specific gravity is increased in the range from 0.4 to 0.7. According as the added amount of water repellent agent was increased. frost resistance was improved and absorption ratio was decreased. ALC produced from fine Al powder has a low volume reduction by scaling and a sound apperance after freezing/thawing test and top surface freezing test.

Studies on the soil freezing depth and change of moisture contents in evergreen plants upon subzero temperature in (강원도지역의 토양동결심 및 상록식물의 함수량 추이에 관한연구 (1))

  • 홍종운;허범양;원경열;임병춘;이기철;하상건
    • Asian Journal of Turfgrass Science
    • /
    • v.4 no.1
    • /
    • pp.42-48
    • /
    • 1990
  • Experiments were conducted to investigate the soil freezing depth and pattern with freezing measuring instruments during 1988-l989 winter season in Kangwon province. Freezing measuring instrument was made with acrylic pipes which were consisted of inner and outer parts. Inner pipe was filled with 0.01 % methylene blue solution and rubber hose to protect pipe breakdown by solution freezing. Freezing measurements were carried out by observing discoloration of methylene blue solution. Moisture content of evergreen trees and ground cover plants was also examined in the winter season. The observed results are as follows: 1.In the land of I OOM above sea level, soil freezing depth became deeper as the sum of Accumulated degree-days of temperature below 0˚C(0˚C . day) increased: Soil freezing depth was 30-40cm at l00˚C, 42-43cm at 150˚C, and 47cm at 200˚C day 2.Soil freezing with vinyl mulching was less developed by l3cm at l00˚C with sum of subzero temperature, by l7cm at 200˚C than that of the bare ground. Soil of rich hulls mulching with 4Ocm was not frozen until soil freezing at the bare ground was developed to 25cm depth. 3.Cashmeron mulching was more effective than felt mulching in the heat insulation of soil. 4.Thawing of soil was done from the lowest part of the frozen in the ground to upward in the beginning and after that it was done from the surface of frozen soil to downward. Finally thawing was completed at the middle of frozen soil.

  • PDF

Hysteretic Behavior of RC Beams Exposed to Freezing and Thawing under Cyclic Loadings (철근콘크리트보의 동결융해 경험에 따른 반복하중하에서의 이력특성)

  • Jang, Gwang-Soo;Kim, Yun-Su;Seo, Soo_Yeon;Choi, Ki-Bong;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.25-28
    • /
    • 2008
  • Generally, reinforced concrete structures exposed to the outside temperature are affected by freezing and thawing process during winter and early spring. These freezing and thawing process can lead to the reduction in durability of concrete as cracking or surface spalling. This paper is to study the hysteretic behavior of RC beams exposed to freezing and thawing under cyclic loadings. To compare the difference in hysteretic behavior of RC Beams, limited tests were conducted under different types of damage and freezing and thawing cycles. For this purpose, six specimens were tested. It is thought that experimental results will be used as basic data to evaluate hysteretic behavior of RC beams exposed to freezing and thawing.

  • PDF

Freezing-Thawing Resistance of Concrete Using Steel Slag as Coarse Aggregate (제강슬래그를 굵은 골재로 이용한 콘크리트의 동결융해 저항성)

  • Lee, Hyo-Seong;Han, Sang-Ho
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • In this study, freezing-thawing resistance of concrete using steel slag as coarse aggregate(steel slag concrete) from Gwangyang Iron Co. was estimated to offer basic data for utilization of much more steel slag. Freezing-thawing test of concrete using crushed stone as coarse aggregate(crushed stone concrete) whose compressive strength and air contents are as close as possible to those of the steel slag concrete was performed. Because they are main two factors that affect of freezing-thawing resistance. The test was carried out up to 400 cycles according to KS F 2456. The compressive strength and weight of two concretes were measured and compared. As a result, the freezing-thawing resistance of steel slag concrete curing in water was almost the same with that of crushed stone concrete. But the resistance of steel slag concrete curing in air dry condition was weaker than that of crushed stone concrete. Also, the steel slag concrete which has more than 60% of W/C ratio showed much more surface degradation when compared to crushed stone concrete.

The Effect of Cellulase on the Pore Structure of Cellulose Fibers

  • Park, Sun-Kyu;Venditti Richard A.;Abrecht David G.;Jameel Hasan;Pawlak Joel J.;Lee, Jung-Myoung
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.43-49
    • /
    • 2006
  • The surface and pore structure of cellulose fibers have a significant impact on the properties and performance in applications. Cellulase enzymatic hydrolysis of cellulose fibers can result in changes to the surface and pore structure thus providing a useful tool for fiber modification. This research characterizes these changes using various test methods such as fiber dimension, water retention value, hard-to-remove water content, freezing and non-freezing bound water content, polymer adsorption, and crystallinity index. For a high-dosage enzyme treatment (0.10 g/g), the fiber length was significantly decreased and the fibers were 'cut' in the cross direction, not in the axial direction. The swelling capacities as measured by the WRV and HR water content increased for the high-dosage treatment. Three independent measurements (non-freezing bound water, polymer adsorption, and crystallinity index) are in good agreement with the statement that the amorphous regions of cellulose fibers are a more readily available substrate relative to crystalline regions. Based on the experimental results obtained herein, a model was proposed to explain surface and pore structure modification of cellulose fibers via enzymatic treatment.

  • PDF