• 제목/요약/키워드: Surface extension

Search Result 660, Processing Time 0.027 seconds

Mungbean Cultivar, 'Munpyeong', with a Short Stem and High Yield (단경 다수성 녹두 품종 '문평')

  • Kim, Dong-Kwan;Choi, Jin-Gyung;Kwon, Oh-Do;Lee, Kyung-Dong;Seo, Min-Jung;Kim, Hyun-Tae
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.485-489
    • /
    • 2018
  • A mungbean cultivar "Munpyeong" (Vigna radiata (L.) Wilczek) was derived as a cross between "Keumseong" and "IT163157" at the Jeollanamdo Agricultural Research and Extension Services (JARES) in 2013. "Munpyeong" has an erect growth habit, heart leaflet, green hypocotyls, black and straight pods when matured, and a dull green seed surface. The stem length of "Munpyeong" was 60 cm, which was 6 cm shorter than that of the control cultivar "Owool." The pod number per plant was 25, which was 3 more than that of the control cultivar. The 1000 seed weight of "Munpyeong" was 45 g, which was 4 g lighter than that of the control cultivar "Owool." Its field resistance to mungbean mottle virus, cercospora leaf spot, and powdery mildew are similar to the control cultivar, whereas its field resistance to lodging was slightly stronger. The hard seed rate of "Munpyeong" was 3.2%, which was similar to that of the control cultivar. The sprout yield ratio was 7.54 times, which was 9% more than that of the control cultivar. The average yield of "Munpyeong" was 1.93 ton/㏊, which was 21% more than that of the control cultivar "Owool" (Cultivar registration number: 5878).

A Study on the Estimation of the Minimum Buoyancy for the Respiration of a Drowning Person (익수자의 호흡이 가능한 최소 부력 추정에 관한 연구)

  • Yim, Jeong-Bin;Park, Deuk-Jin;Kang, Yu Mi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.7
    • /
    • pp.820-828
    • /
    • 2017
  • Tools and equipment that can provide buoyancy for a drowning person are important for saving lives. The purpose of this study was to estimate the minimum amount of gas needed and the buoyancy value in newton units required to generate the minimum buoyancy determined to be sufficient for keeping the head of a drowning person above the water's surface to allow for respiration for at least 1 minute. A buoyancy experiment was carried out with a long rubber balloon injected with carbon dioxide gas, and a buoyancy measurement experiment was performed on six college students. The degree of buoyancy was measured using a 5-point scale, and the statistical value of the measured data was analyzed to estimate minimum buoyancy. As a result, 8 grams of carbon dioxide were determined to satisfy minimum buoyancy conditions with a confidence level of 72%, and buoyancy was calculated to be 44.66 newtons. 12 grams of carbon dioxide met the minimum buoyancy conditions with a confidence level of 100%, and buoyancy was calculated to be 66.99 newtons. This study is expected to contribute to the development of low cost, easy-to-carry minimum buoyancy aids.

The use of MODIS atmospheric products to estimate cooling degree days at weather stations in South and North Korea (MODIS 대기자료를 활용한 남북한 기상관측소에서의 냉방도일 추정)

  • Yoo, Byoung Hyun;Kim, Kwang Soo;Lee, Jihye
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.2
    • /
    • pp.97-109
    • /
    • 2019
  • Degree days have been determined using temperature data measured at nearby weather stations to a site of interest to produce information for supporting decision-making on agricultural production. Alternatively, the data products of Moderate Resolution Imaging Spectroradiometer (MODIS) can be used for estimation of degree days in a given region, e.g., Korean Peninsula. The objective of this study was to develop a simple tool for processing the MODIS product for estimating cooling degree days (CDD), which would help assessment of heat stress conditions for a crop as well as energy requirement for greenhouses. A set of scripts written in R was implemented to obtain temperature profile data for the region of interest. These scripts had functionalities for processing spatial data, which include reprojection, mosaicking, and cropping. A module to extract air temperature at the surface pressure level was also developed using R extension packages such as rgdal and RcppArmadillo. Random forest (RF) models, which estimate mean temperature and CDD with a different set of MODIS data, were trained at 34 sites in South Korea during 2009 - 2018. Then, the values of CDD were calculated over Korean peninsula during the same period using those RF models. It was found that the CDD estimates using the MODIS data explained >74% of the variation in the CDD measurements at the weather stations in North Korea as well as South Korea. These results indicate that temperature data derived from the MODIS atmospheric products would be useful for reliable estimation of CDD. Our results also suggest that the MODIS data can be used for preparation of weather input data for other temperature-based agro-ecological models such as growing degree days or chill units.

Design of Submarine Cable for Capacity Extension of Power Line (전력선 용량증대를 위한 해저케이블 설계)

  • Son, Hong-Chul;Moon, Chae-Joo;Kim, Dong-Sub
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.77-84
    • /
    • 2022
  • A submarine power cable is a transmission cable for carrying electric power below the surface of the water. Recently, submarine cables transfer power from offshore renewable energy schemes to shore, e.g. wind, wave and tidal systems, and these cables are either buried in the seabed or lie on the ocean floor, depending on their location. Since these power cables are used in the extreme environments, they are made to withstand in harsh conditions and temperatures, and strong currents. However, undersea conditions are severe enough to cause all sorts of damage to offshore cables, these conditions result in cable faults that disrupt power transmission. In this paper, we explore the design criteria for such cables and the procedures and challenges of installation, and cable transfer splicing system. The specification of submarine cable designed with 3 circuits of 154kV which is composed of the existing single circuit and new double circuits, and power capacity of 100MVA per cable line. The determination of new submarine cable burial depth and cable arrangement method with both existing and new cables are studied. We have calculated the permission values of cable power capacity for underground route, the values show the over 100MW per cable line.

Species Composition and Assemblage Structure of Fish Collected by Set Net at the Coastal Waters of Goseong in Gangwon-do, Korea (강원도 고성연안에서 정치망으로 채집된 어류 종조성과 군집구조)

  • Lee, Soo Jeong;Yang, Jae-Hyeong;Seo, Young Il;Kim, Jin-Koo
    • Korean Journal of Ichthyology
    • /
    • v.33 no.2
    • /
    • pp.95-106
    • /
    • 2021
  • In order to understand the seasonal variations of species composition of fish in the Goseong, middle East Sea of Korea, we surveyed fish fauna using set net during 2 years. In this study, a total of 77 taxa belonging to 40 families were collected and 75 species were identified. The dominant family were Tetraodontidae and Pleuronectidae, and the dominant species were Arctoscopus japonicus, Konosirus punctatus, Stephanolepis cirrhifer, Thamnaconus modestus, and Trachurus japonicus. The results of the hierarchical clustering using the number of individuals of collected species showed that they are divided into three seasonal groups: Group A (Jan.~Apr.), Group B (May~Jun., Nov.~Dec.), Group C (Jul.~Oct.). The sea surface temperature (SST) was higher than the results of previous studies in winter and spring, and species composition in spring have changed from cold-water species to the warm-water species, recently. The species composition has become similar to the that of southern Gangwon-do regions (Samcheok and Gangneung) of the previous studies. The species diversity of family Tetraodontidae has increased, which is estimated to have an effect on increase in SST and the quantity of entering the East Sea. Therefore, we assumed that the change of species composition is related to the extension of northern distribution limits and survival temperature, and abundant preys. Therefore, it is necessary that an efficient resource management policy as well as the ways of commercially use of migratory warm-water fish, rapidly.

An Optimal Standardized in vitro Bioassay to Evaluate Susceptibility of Green Peach Aphid, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), to Aphicides (복숭아혹진딧물, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), 살진딧물 최적 in vitro 살충력 검정 방법 확립)

  • Ka Hee Cho;Hyo Jung Kim;Young Cheol Kim
    • Korean journal of applied entomology
    • /
    • v.62 no.3
    • /
    • pp.139-147
    • /
    • 2023
  • Leaf-spray in vitro bioassays appraise new aphicidal formulations for managing deleterious plant-feeding aphids. The formulation may utilize alternative and integrated strategies. However, leaf spraying even under controlled conditions may affect aphid reproduction and mortality. This study examines leaf spray applications for optimum and reproducible aphicidal results using tobacco leaves overlaid on cotton fabric or water agar surfaces. Infestation of the undersides of tobacco leaves with nymphs of green peach aphids was used in the assays. Spray distance and volume were optimized using water-sensitive paper to ascertain the best surface coverage. Overlays of the leaves on water agar caused less mortality and greater reproduction than the use of cotton fabric. The relative humidity of the insect-rearing chambers changed with the watering regime for the insect - rearing chambers with cotton fabric; 60% relative humidity was optimal. Relative humidity was not affected by the concentration of agar in the water agar chambers. Applications of the chemical aphicidal standard, Sulfoxaflor, under the optimized conditions exhibited similar times for lethality although the rate was faster with leaves on the cotton fabric than on water agar. These studies establish reproducible and sensitive techniques for assessing the lethality and effects on reproduction of potential aphicidal products.

Effects of Environmental Conditions on Vegetation Indices from Multispectral Images: A Review

  • Md Asrakul Haque;Md Nasim Reza;Mohammod Ali;Md Rejaul Karim;Shahriar Ahmed;Kyung-Do Lee;Young Ho Khang;Sun-Ok Chung
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.319-341
    • /
    • 2024
  • The utilization of multispectral imaging systems (MIS) in remote sensing has become crucial for large-scale agricultural operations, particularly for diagnosing plant health, monitoring crop growth, and estimating plant phenotypic traits through vegetation indices (VIs). However, environmental factors can significantly affect the accuracy of multispectral reflectance data, leading to potential errors in VIs and crop status assessments. This paper reviewed the complex interactions between environmental conditions and multispectral sensors emphasizing the importance of accounting for these factors to enhance the reliability of reflectance data in agricultural applications.An overview of the fundamentals of multispectral sensors and the operational principles behind vegetation index (VI) computation was reviewed. The review highlights the impact of environmental conditions, particularly solar zenith angle (SZA), on reflectance data quality. Higher SZA values increase cloud optical thickness and droplet concentration by 40-70%, affecting reflectance in the red (-0.01 to 0.02) and near-infrared (NIR) bands (-0.03 to 0.06), crucial for VI accuracy. An SZA of 45° is optimal for data collection, while atmospheric conditions, such as water vapor and aerosols, greatly influence reflectance data, affecting forest biomass estimates and agricultural assessments. During the COVID-19 lockdown,reduced atmospheric interference improved the accuracy of satellite image reflectance consistency. The NIR/Red edge ratio and water index emerged as the most stable indices, providing consistent measurements across different lighting conditions. Additionally, a simulated environment demonstrated that MIS surface reflectance can vary 10-20% with changes in aerosol optical thickness, 15-30% with water vapor levels, and up to 25% in NIR reflectance due to high wind speeds. Seasonal factors like temperature and humidity can cause up to a 15% change, highlighting the complexity of environmental impacts on remote sensing data. This review indicated the importance of precisely managing environmental factors to maintain the integrity of VIs calculations. Explaining the relationship between environmental variables and multispectral sensors offers valuable insights for optimizing the accuracy and reliability of remote sensing data in various agricultural applications.

THE EFFECT OF CYCLIC LOADING ON THE RETENTIVE STRENGTH OF FULL VENEER CROWNS (반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구)

  • Kim, Ki-Youn;Lee, Sun-Hyung;Chung, Hun-Young;Yang, Jae-Ho;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.583-594
    • /
    • 2000
  • Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

  • PDF

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF

Effect of Permanent Wave on Hair Damage and Morphological Changes after Natural Henna Treatment (천연헤나 처리 후 퍼머넌트 웨이브 시술 시 모발 손상도 및 형태학적 변화에 미치는 영향)

  • Lee, Eun-Jin;Lee, June-Hee;Lee, Jae-Nam
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.915-929
    • /
    • 2019
  • This study attempted to investigate the effects of natural henna-treated permanent wave on degree of damage and morphological changes of hair. For this, amino acid was analyzed, and hair thickness and surface were observed through SEM. In addition, hair curl formation & retention, methylene blue coloring, tensile strength and elongation were measured. The results found the followings: Total amino acid contents rose as the number of natural henna treatment increased, hair protection effects are expected. In terms of curl formation, in an experimental group hair became more elastic as the number of natural henna treatment increased, compared to a control group. In both control and experimental groups, hair retention decreased as shampooing frequency increased because of extension of (C) and (C)', According to analysis of hair thickness using SEM, hair became thick in an experimental group after natural henna treatment, compared to a control group. In morphological observation of hair surface, it was mostly clean, and cuticle was tidy and healthy. In methylene blue coloring, as the number of natural henna treatment increased, absorbance went up. In addition, tensile strength declined in an experimental group, compared to a control group. As the number of natural henna treatment increased, elongation in an experimental group increased, compared to a control group. The above results show that as the number of natural henna treatment increased, hair became thicker, and curl formation and retention improved. In addition, hair elasticity and flexibility were enhanced, reducing a risk of hair damage. Therefore, the study results would be available as basic data in reducing scalp and hair damage, proposing the natural henna treatment as a method to reduce hair damage from chemical perm in cosmetology industry.