• Title/Summary/Keyword: Surface electrical resistivity

Search Result 683, Processing Time 0.028 seconds

Correlation Between Bulk and Surface Resistivity of Concrete

  • Ghosh, Pratanu;Tran, Quang
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.1
    • /
    • pp.119-132
    • /
    • 2015
  • Electrical resistivity is an important physical property of portland cement concrete which is directly related to chloride induced corrosion process. This study examined the electrical surface resistivity (SR) and bulk electrical resistivity (BR) of concrete cylinders for various binary and ternary based high-performance concrete (HPC) mixtures from 7 to 161 days. Two different types of instruments were utilized for this investigation and they were 4 point Wenner probe meter for SR and Merlin conductivity tester for bulk resistivity measurements. Chronological development of electrical resistivity as well as correlation between two types of resistivity on several days was established for all concrete mixtures. The ratio of experimental surface resistance to bulk resistance and corresponding resistivity was computed and compared with theoretical values. Results depicted that bulk and SR are well correlated for different groups of HPC mixtures and these mixtures have attained higher range of electrical resistivity for both types of measurements. In addition, this study presents distribution of surface and bulk resistivity in different permeability classes as proposed by Florida Department of Transportation (FDOT) specification from 7 to 161 days. Furthermore, electrical resistivity data for several HPC mixtures and testing procedure provide multiple promising options for long lasting bridge decks against chloride induced corrosion due to its ease of implementation, repeatability, non-destructive nature, and low cost.

Surface Characteristics of Silicone Rubber Processes by Corona Discharges (코로나 방전에 따른 실리콘 고무의 표면 특성)

  • 한동희;조한구;강동필;민경은
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2002
  • This paper aims to investigate the effect of silicone oils as processing agent affecting the loss and recovery of hydrophobicity. The recovery of hydrophobicity was evaluated by the measurement of the surface electrical resistivity and the contact angle on the SIR surface. Two kinds of silicone oils (1 and 2) having different molecular weight were selected under a consideration of hydrophobicity and processability. SIR specimens were exposed to corona discharges in air and the specimens were analyzed with contact angle and surface resistance measurements. It was observed that the contact angle and the surface resistivity of SIR increase gradually with testing time. The fast recovery of hydrophobicity of SIR, expressed by the increment of contact angle and surface resistivity, was showed in SIR2 containing silicone oil 2.

Humidity effects on surface resistivities in PE and PP mixtures (PE 및 PP혼합 재료의 표면저항에 미치는 습도효과)

  • 강전홍;유황민;김한준;한상옥;김종석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.424-426
    • /
    • 2002
  • The surface and volume resistivity in the polymers, PE(polyethylene) and PP(polypropylene) mixtures are tested and measured by the ASTM D257(KS M3015) standard. Humidity effects on surface and volume resistivity in two polymers have been studied qualitatively at room temperature. The results of resistivity in these polymers show that the values of surface resistivity (and volume resistivity) at the humidity of 90% are remarkably small compared with those at the humidity of 50%, independing on applied voltage. When we varied the humidity in two polymers, it was found to takes many hours to recover into original surface resistivity (and volume resistivity) of these polymers.

  • PDF

FE model of electrical resistivity survey for mixed ground prediction ahead of a TBM tunnel face

  • Kang, Minkyu;Kim, Soojin;Lee, JunHo;Choi, Hangseok
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.301-310
    • /
    • 2022
  • Accurate prediction of mixed ground conditions ahead of a tunnel face is of vital importance for safe excavation using tunnel boring machines (TBMs). Previous studies have primarily focused on electrical resistivity surveys from the ground surface for geotechnical investigation. In this study, an FE (finite element) numerical model was developed to simulate electrical resistivity surveys for the prediction of risky mixed ground conditions in front of a tunnel face. The proposed FE model is validated by comparing with the apparent electrical resistivity values obtained from the analytical solution corresponding to a vertical fault on the ground surface (i.e., a simplified model). A series of parametric studies was performed with the FE model to analyze the effect of geological and sensor geometric conditions on the electrical resistivity survey. The parametric study revealed that the interface slope between two different ground formations affects the electrical resistivity measurements during TBM excavation. In addition, a large difference in electrical resistivity between two different ground formations represented the dramatic effect of the mixed ground conditions on the electrical resistivity values. The parametric studies of the electrode array showed that the proper selection of the electrode spacing and the location of the electrode array on the tunnel face of TBM is very important. Thus, it is concluded that the developed FE numerical model can successfully predict the presence of a mixed ground zone, which enables optimal management of potential risks.

Electrical Properties of the Transparent Conducting Oxide Layers of Al-doped ZnO and WO3 Prepared by rf Sputtering Process

  • Gang, Dong-Su;Kim, Hui-Seong;Lee, Bung-Ju;Sin, Baek-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.316-316
    • /
    • 2014
  • Two different transparent conducting oxide (TCO) layers of Al-doped ZnO (AZO) and $WO_3$ were prepared by a rf sputtering process. Working pressure, deposition time, and target-to-substrate distance were varied for the sputtering process to improve electrical properties of the resulting layer. Thickness of the TCO layers was measured by a profile meter of ${\alpha}$-step. To evaluate the electrical conductivity, surface resistivity of the TCO layers was measured by a four-point probe technique. Decrease of the working pressure resulted in increase of deposition rate and decrease of surface resistivity of the resulting layer. Increase of the layer thickness due to increased deposition time resulted in decrease of surface resistivity of the resulting layer. The shorter the target-to-substrate distance was, the lower was the surface resistivity of the resulting layer.

  • PDF

Time-lapse Resistivity Investigations for Imaging Subsurface Grout during Ground Stabilization

  • Farooq, Muhammad;Park, Sam-Gyu;Kim, Jung-Ho;Song, Young-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.241-244
    • /
    • 2007
  • Cement-grouts are injected into limestone cavities beneath the road in the project area, in order to improve strength and reduce permeability; the extent to which grout has penetrated in cavities need to be monitored in order to determined effectiveness of cement-grout. Geophysical approaches, offer great potential for monitoring the grout injection process in a fast and cost-effective way as well as showing whether the grout has successfully achieved the target. This paper presents the ability of surface electrical resistivity to investigate the verification of the grout placement. In order to image the cement-grout, time-lapse surface electrical resistivity surveys were conducted to compare electrical resistivity images before and after injection. Cement-grout was imaged as anomalies exhibiting low resistivity than the surrounding rocks. In accordance with field monitoring, laboratory study was also designed to monitor the resistivity changes of cement-grout specimens with time-lapse. Time-lapse laboratory measurements indicated that electrical methods are good tool to identify the grouted zone. Pre-and post grouting electrical images showed significant changes in subsurface resistivity at grouted zone. The study showed that electrical resistivity imaging technology can be a useful tool for detecting and evaluating changes in subsurface resistivity due to the injection of the grout.

  • PDF

Surface Characterization of Silicone Rubber for Outdoor Insulation by Measurement of Surface Voltage Decay

  • Youn, Bok-Hee;Huh, Chang-Su;Cho, Han-Gu
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.12C no.4
    • /
    • pp.214-219
    • /
    • 2002
  • The influence of ultraviolet (UV) irradiation and corona on the surface degradation of high temperature vulcanized (HTV) silicone rubber used for outdoor insulation through measuring surface voltage decay after corona charging, surface resistivity, contact angle and X-ray photoelectron spectroscopy (XPS) analysis was studied. The surface resistivity calculated by the surface voltage decay was compared with a value directly obtained from the three electrode method having the guard ring electrode. A good agreement between the two methods for surface resistivity was obtained. UV treated specimens showed the slower decrease of surface voltage decay, while the corona exposed specimens showed a dramatically faster decrease. Although both artificial treatments cause the same oxidative products, which was confirmed with XPS, we could distinguish the difference between the reactions of the two treatments by monitoring the surface voltage decay on corona-charged specimen. In addition, we could derive the specific surface states of the silicone rubber treated by accelerated artificial aging factors and the degradation process.

The Study on the Electrical Resistivity for Mo Back Contacts Film of CIGS Solar Cell (태양전지 CIGS용 Mo 후면전극의 전기 저항에 관한 연구)

  • Kim, Gang-Sam;Cho, Yong-Ki
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.6
    • /
    • pp.264-268
    • /
    • 2011
  • The Molybedenium thin film is generally used on back contact material of CIGS solar cell due to low electrical resistivity and stable thermal expansion coefficient. The Mo thin films deposited on si wafer by the magnetron sputtering method. The research focused on the variation of electrical resistivity of films which deposited with various working pressure at the target power of 2.0 kW(8.4 W/). The lowest resistivity of Mo thin film showed $9.0{\mu}O$-cm at pressure of 1.5 mTorr. However, working pressure increasing up to 50 mTorr, resistivities were highly increased. The results showed that the conductivity of Mo films depended on growing structures and defects in deposition process. Surface morphology, porosity, grain size, oxidation, and bonding structures were analysed by SEM, AFM, spectroscopic ellipsometry (SE), XRD, and XPS.

Analyses on the Increment of Surface Hydrophobicity of Epoxy Composites by Thermal Treatment (열철리에 따른 Epoxy 복합재료의 표면 소수성증가에 관한 해석)

  • Lim, Kyung-Bum;Lee, Beak-Su;Chung, Mu-Yong;Lee, Duck-Chool
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.153-160
    • /
    • 2001
  • In order to analyze the degradation process of epoxy/glass fiber for outdoor condition, FRP laminate was exposed to high temperature. Then, the degradation process was evaluated by comparing contact angle, surface potential, surface resistivity, and XPS. The experimental results showed that the amount of weight loss, contact angle, surface potential and surface resistivity increased up to 200 $^{\circ}C$ as a function of temperature. These phenomena show the existence of hydrophobic surface. With the change to the hydrophobic surface and the electrical potential and resistivity on FRP surface increased. In XPS to analyze surface chemical structures, the increased hydrophobicity in thermal increase of unsaturated double bond in carbon chains. Aslo, thermal treatment caused the discoloration on the point of treated surface. These phenomena were attributed to the generations of ether group.

  • PDF

Effect of exfoliated graphite nanoplatelets on the fracture surface morphology and the electrical resistivity of phenylethynyl-terminated polyimide

  • Cho, Dong-Hwan;Fukushima, Hiroyuki;Drzal, Lawrence T.
    • Carbon letters
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2012
  • In the present work, exfoliated graphite nanoplatelets (EGN) of 1 ${\mu}m$ in average particle size, which were prepared by heating at $900^{\circ}C$ and then subjected to ultrasonic, ball-milling, and vibratory ball-milling techniques, were uniformly incorporated into phenylethynyl-terminated polyimide (PETI-5) resin. The fracture surface morphology and the electrical resistivity of the EGN/PETI-5 composites were investigated. The results showed that the fracture surfaces and the electrical resistivity strongly depended on the EGN content. The fracture surfaces became more ductile and roughened with increasing EGN and the electrical resistivity was gradually decreased with increased EGN loading, indicating the percolation threshold at 5 wt% EGN.