• 제목/요약/키워드: Surface decontamination

검색결과 141건 처리시간 0.028초

드라이아이스 펠렛 분사에 의한 모의 시편의 제염 (Decontamination of Simulated Test Piece by Dry Ice Pellet Blasting)

  • 신진명;박장진;양명승
    • 환경위생공학
    • /
    • 제19권2호
    • /
    • pp.30-36
    • /
    • 2004
  • Dry decontamination technique is required for maintaining nuclear material handling equipment contaminated with highly radioactive material in a hot cell. In order to determine the optimum blasting conditions of dry ice pellet blasting device, the basic experiments have been conducted on the simulated test specimens of four types of metals. The removal efficiency of test piece was evaluated by the XRF analysis and the change of the surface condition before and after blasting. The removal efficiency of cesium on loose contamination was 100% under blasting pressure; 3 kg/$cm^2$, blasting distance; 10 cm, blasting time: 10 sec. In case of fixed contamination, the removal efficiency of cesium was almost 96% under blasting pressure; 4kg/$cm^2$, blasting distance; 10 cm, blasting time; 30 sec.

ABRASIVE BLASTING TECHNOLOGY FOR DECONTAMINATION OF THE INNER SURFACE OF STEAM GENERATOR TUBES

  • Kim, Gye-Nam;Lee, Min-Woo;Park, Hye-Min;Choi, Wang-Kyu;Lee, Kune-Woo
    • Nuclear Engineering and Technology
    • /
    • 제43권5호
    • /
    • pp.469-476
    • /
    • 2011
  • The inner surfaces of bundled inconel tubes from steam generators in South Korean nuclear power plants are contaminated with cobalt and abrasive blasting equipment has been developed to efficiently remove the cobalt. The principal parameters related to the efficient removal using this equipment are the type of abrasive, the distance from the nozzle, and the blasting time. Preliminary tests were performed using oxidized inconel samples which enabled the simulation of cobalt removal from the radioactive inconel samples. The oxygen in the oxidized samples and the cobalt in the radioactive inconel were removed more effectively using the blasting distance, blasting time, and a silicon carbide abrasive. Using the developed abrasive blasting equipment, the optimum decontamination conditions for radioactive inconel samples were blasting for more than 6 minutes using silicon carbides under 5 atmospheric pressures.

과산화수소 증기를 이용한 다양한 쿠폰 표면의 Geobacillus Stearothermophilus 아포 제독조건 (Decontamination Condition of Geobacillus Stearothermophilus Spore on the Surface of Various Coupons using Hydrogen Peroxide Vapor)

  • 김상훈;정경화;김세계;채영규;김윤기;황현철;김민철;박명규;류삼곤
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.560-565
    • /
    • 2013
  • Biological decontamination means the removal of microorganisms from the inanimate object such as building or equipment. In this study, hydrogen peroxide vapor efficacy test using VHP 1000ED system(Steris LifeSciences) were conducted for G. stearothermophilus spore with agent materials(aluminum, stainless steel, poly-carbonate, viton, silicone, kapton and glass). Total recovered spores exposed to hydrogen peroxide vapor(1.0 g/min) during 7, 15, 30, 60 min were calculated. As a result, all agent materials were totally decontaminated within 60 min at 1.0 g/min concentration with 35% hydrogen peroxide vapor. Finally, we could confirmed that hydrogen peroxide vapor possess sporicidal capacity of G. stearothermophilus and found the optimum decontamination conditions with VHP1000ED system.

회전형 타이타늄 브러쉬를 이용한 임플란트 주위염 재생술식: 2년 추적결과 증례 보고 (Regenerative procedure using rotary titanium brush for surface decontamination of peri-implantitis: 3 cases with a 2-year follow-up)

  • 백민우;유정아;최성호;이동운
    • 구강회복응용과학지
    • /
    • 제37권4호
    • /
    • pp.259-267
    • /
    • 2021
  • 본 증례보고에서는 임플란트 주위염으로 진단된 임플란트의 오염된 표면을 회전형 타이타늄 브러쉬로 처리후 재생적 처치를 시도한 3가지 증례에 대한 임상적 및 방사선학적 평가를 목적으로 하였다. 2년간 추적결과에서 3가지 증례의 평균변형치태지수가 1.12에서 0.19로, 변형열구출혈지수가 1.38에서 0.25로, 치주낭 깊이가 8.73 mm에서 3 mm로, 임플란트 상부와 골이 처음 접하는 부위까지의 거리값이 6.35 mm에서 2.3 mm로 감소하는 개선을 보였으며, 기존의 보철물로 유지할 수 있었다. 향후 장기적인 추적을 통해 본 술식의 효과를 뒷받침할 수 있는 근거를 마련할 것이 필요할 것이다.

하나로 1차 냉각펌프 제염에 대한 고찰 (Study on the Decontamination of Primary Cooling Pump in HANARO)

  • 안정석;이경호;김광득;박용철
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.21-29
    • /
    • 2005
  • 30 MW의 연구용 원자로인 하나로는 1995년 2월 초임계에 도달한 이후, 정상적으로 가동하고 있다. 가동 후 약 10년이 경과하여 1차 냉각펌프를 분해 점검하기 위해 펌프에 대한 화학제염이 2004년에 수행되었다. 제염을 수행하기 이전에 4개의 point를 설정하여 방사선량율 및 표면오염도를 측정하였고, 최종제염이 수행된 이후 같은 point에 대하여 방사선량율 및 표면오염도를 재측정 하였다. 펌프 외부는 노출되어 있어 쉽게 제염할 수 있으나 케이싱 내부에는 2중 볼류트가 있어 접근이 용이하지 않았다. 이를 제염하기 위하여 제염장치를 개발하였다. 이 장치는 일정 농도의 제염제 (DX-300)를 케이싱 내부에 담아 밀폐시킨 후 펌프의 임펠러를 저속으로 회전함으로서 제염제가 순환된다. 제염제의 유화작용에 의해 표면의 입자성 방사선 물질이 이완되고, 화학 작용에 의해 부식력과 용해성으로 표면 오염이 제거된다. 이 장치를 이용하여 하나로 1차 냉각펌프의 케이싱 내부를 제염하였다. 그 결과 1차 냉각펌프의 케이싱 내부는 반출허용표면오염도 이하로 낮출 수 있어 성공적으로 제염할 수 있었다.

  • PDF