• Title/Summary/Keyword: Surface coverage

Search Result 494, Processing Time 0.026 seconds

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

A Study on the Management of Micropollutants in Water System Considering Climate Change and other Potential Effects (기후변화 등 잠재적 영향을 고려한 수중 미량오염물질의 관리방향 연구)

  • Kim, Hojeong;Hong, Yongsuk;Ahn, Jong Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.645-654
    • /
    • 2013
  • In this study, the management polices of micropollutants (MPs) were reviewed and the future management strategy was discussed considering climate change and etc. In Korea, the investigation of drinking water has been actively carried out for the priority contaminants as well as MPs. Recently river and lake waters have been also examined for MPs. However, the coverage and depth of the investigation is limited. Moreover, climate change is likely to increase air & water temperature and it will affect the hydrological cycle. Such changes may increase the residual concentrations of MPs in water system. As water reuse increases, the residual MPs of the recycled water may create public concerns. Thus, in a viewpoint of the precautionary principle, more stringent management of MPs is recommended for the drinking water and the body-contact water use. For the surface water, more studies are necessary to understand the ecological risk by MPs.

Comparison of Enzymatic Activity and Cleavage Characteristics of Trypsin Immobilized by Covalent Conjugation and Affinity Interaction (공유결합과 친화력결합에 의한 고정화 Trypsin의 효소역가와 절단특성 비교)

  • Jang, Dae-Ho;Seong, Gi-Hun;Lee, Eun-Kyu
    • KSBB Journal
    • /
    • v.21 no.4
    • /
    • pp.279-285
    • /
    • 2006
  • We investigated the effects of immobilization chemistry on the yield of immobilization and the bioactivity of the immobilized enzymes. Trypsin as a model protein and macroporous polymer beads(Toyopearl AF 650M, Tosho Co., Japan) was used as a model matrix. Four methods were used to immobilize trypsin; covalent conjugation by reductive amination(at pH 10.0 and pH 4.0) and affinity interaction via streptavidin-biotin, and double-affinity interaction via biotin-streptavidin-biotin system. The covalent conjugation immobilized $3{\sim}4$ mg/ml-gel, ca. 3-fold higher than the affinity method. However, the specific activity of the covalently(pH 10.0) and affinity-immobilized trypsin(via streptavidin-biotin) are ca. 37% and 50%, respectively, of that of the soluble enzyme(on the low-molecular-weight BAPNA substrate). When the molecular size of a substrate increased, the affinity-immobilized trypsin showed higher clavage activity on insulin and BSA. This result seemed to indicate the streptavidin-biotin system allowed more steric flexibility of the immobilized trypsin in its interaction with a substrate molecule. To confirm this, we studied the molecular flexibility of immobilized trypsin using quartz crystal microbalance-dissipation. Self-assembled monolayers were formed on the Q-sensor surface by aminoalkanethiols, and gultaraldehyde was attached to the SAMs. Trypsin was immobilized in two ways: reductive amination(at pH 10.0) and the streptavidin-biotin system. The dissipation shift of the affinity-immobilized trypsin was $0.8{\times}10^{-6}$, whereas that of the covalently attached enzyme was almost zero. This result confirmed that the streptavidin-biotin system allowed higher molecular flexibility. These results suggested that the bioactivity of the immobilized enzyme be strongly dependent on its molecular flexibility.

Analysis on the Langmuir Adsorption Isotherm of the Over-Potentially Deposited Hydrogen (OPD H) at the Polycrystalline Au|Acidic Aqueous Electrolyte Interface Using the Phase-Shift Method

  • Chun Jang H.;Jeon Sang K.
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.118-124
    • /
    • 2001
  • The Langmuir adsorption isotherm of the over-potentially deposited hydrogen (OPD H) for the cathodic $H_2$ evolution reaction (HER) at the $poly-Au|0.5M\;H_2SO_4$ aqueous electrolyte interface has been studied using cyclic voltammetric and ac impedance techniques. The behavior of the phase shift $(0^{\circ}\leq{-\phi}\leq90^{\circ})$ for the optimum intermediate frequency corresponds well to that of the fractional surface coverage $(1\geq{\theta}\geq0)$ at the interface. The phase-shift profile $({-\phi}\;vs.\;E)$ for the optimum intermediate frequency, i.e., the phase-shift method, can be used as a new method to estimate the Langmuir adsorption isotherm $(\theta\;vs.\;E)$ of the OPD H for the cathodic HER at the interface. At the poly-$Au|0.5M\;H_2SO_4$ electrolyte interface, the equilibrium constant (K) and standard free energy $({\Delta}G_{ads})$ of the OPD H are $2.3\times10^{-6}\;and\;32.2\;kJ\;mol^{-1}$, respectively.

Field Application of Phased Array Ultrasonic Testing for Structural Weld Overlay on Dissimilar Welds of Pressurizer Nozzles (가압기 노즐 이종금속 용접부의 구조적 오버레이 용접부에 대한 위상배열 초음파기법의 현장 적용)

  • Kim, Jin-Hoi;Kim, Yongsik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.268-274
    • /
    • 2015
  • Weld overlay was first used in power plants in the US in the early 1980s as an interim method of repairing the welds of flawed piping joints. Weld overlaid piping joints in nuclear power plants must be examined periodically using ultrasonic examination technology. Portable phased array ultrasonic technology has recently become available. Currently, the application of preemptive weld overlays as a mitigation technique and/as a method to improve the examination surface condition for more complex configurations is becoming more common. These complex geometries may require several focused conventional transducers for adequate inspection of the overlay, the original weld, and the base material. Alternatively, Phased array ultrasonic probes can be used to generate several inspection angles simultaneously at various focal depths to provide better and faster coverage than that possible by conventional methods. Thus, this technology can increase the speed of examinations, save costs, and reduce radiation exposure. In this paper, we explain the general sequence of the inspection of weld overlay and the results of signal analysis for some PAUT (phased array ultrasonic testing) signals detected in on-site inspections.

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

A comparison of bioresorbable membranes alone or in combination with platelet-derived growth factors and insulin-like growth factors on the periodontal healing of the dehiscence defects in dogs. (성견의 열개형 골 결손부에서 흡수성 차단막과 PDGF-BB 및 IGF-I의 혼합 사용시 치주조직의 치유에 미치는 영향)

  • Cho, Kyoo-Sung;Kim, Chang-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.217-234
    • /
    • 1997
  • The purpose of present study is to compare the effect of treatment using $Guidor^{(R)}$ as a barrier membrane in conjunction with platelet-derived growth factor and insulin like growth factors on experimental dehiscence defects. Following the resection of premolar crowns, roots were submerged. After 12 weeks of healing period, experimental dehiscence defects of 4mm in height and 4mm in width were surgically created on the mid-facial aspect of the lower premolar roots in each of 4 adult dogs. After root planning and demineralization of the root surface with citric acid, the control groups received 4% methylcellulose gel only, the test group I received 4% methylcellulose gel and were covered by $Guidor^{(R)}$ and the test group II were treated with PDGF and IGF and 4% methylcellulose gel with $Guidor^{(R)}$ coverage. Histological and histomorphometric analysis following 8 weeks of healing revealed the following results. 1. The new bone formation showed no statistically significant difference in all groups with $0.59{\pm}0.82mm$($14.03{\pm}19.60%$) for control, $0.70{\pm}0.39mm$($16.30{\pm}9.01%$) for group I, $0.87{\pm}0.76mm$($18.74{\pm}16.03%$) for group II. 2. The new cementum formation showed no statistically significant difference in all groups with $0.54{\pm}0.48mm$($l6.38{\pm}14.57%$) for control, $0.95{\pm}0.38mm$($23.43{\pm}9.30%$) for group I, $1.01{\pm}0.75mm$($22.10{\pm}16.ll%$) for gorup II. 3. The root resorption showed statistically significant differences betweenthe control group and all test groups(p<0.05) with $2.11{\pm}0.53mm$($52.93{\pm}12.32%$) for control, $0.63{\pm}0.27mm$($15.32{\pm}7.05%$) for group I, $0.89{\pm}0.33mm$ ($19.26{\pm}7.11%$) for group II. On the bases of these results, there were no statistically difference between treatment using resorbable membrane and resorbable membrane in conjunction with PDGF and IGF in the dehiscence defects, where it was difficult to maintain space. The use of membrane seemed to be more effective in the inhibition of root resorption.

  • PDF

A Study of the Retention Mechanism of the Monosubstituted Benzenes in Reversed-phase Liquid Chromatography (II) (역상 액체크로마토그래피에서 벤젠 일치환체들의 머무름 메카니즘에 관한 연구 (제 2 보))

  • Lee, Dai-Woon;Choi, Yong-Wook;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.135-143
    • /
    • 1988
  • The correlations between chromatographic parameters of monosubstituted benzenes and several physical parameters in reversed phase liquid chromatography were studied. The relationships between retention data and polarity index were investigated by plotting $log(log k'_S/k'_B)$ vs. $P'_S/P'_B$ which were relative retention and relative polarity index of monosubstituted benzenes with respect to benzene, respectively. The linear relationship between relative retention and polarity index was observed for the monosubstituted benzenes having polar group, while in case of those having nonpolar group, the good linearity was observed by combination with relative molecular weight i.e. $(P'_S/P'_B)/(MW_S/MW_B)$. Multivariant regression analysis, $a(P'_S/P'_B)+b(MW_S/MW_B)$+c did not give significantly better correlations compared to single variant analysis, $a[(P'_S/P'_B)/(MW_S/MW_B)]$+c, but multiple stepwise regression analysis was recommended when several physical parameters simultaneously were chosen. The best correlation between retention data for monosubstituted benzenes taken from the literature and substituent constant(${\pi}$), derived from hydrophobic parameter and the first order molecular connectivity index$(^1{\chi}^{\nu})$, was established for methanol/water mobile phase system. The larger the surface coverage of the stationary phase, the higher was the correlation coefficient between these two parameters and retention data.

  • PDF

A Study on the Atomic-Layer Deposition Mechanism and Characteristics of TiN Films Deposited by Cycle-CVD (Cycle-CVD법으로 증착된 TiN 박막의 ALD 증착기구와 특성에 관한 연구)

  • Min, Jae-Sik;Son, Young-Woong;Kang, Won-Gu;Kang, Sang-Won
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.377-382
    • /
    • 1998
  • Atomic layer deposition(ALD) of amorphous TiN films on $SiO_2$ between 17$0^{\circ}C$ and 21O$^{\circ}C$ has been investigated by alternate supply of reactant sources, Ti[N($C_2,H_5,CH_3)_2]_4$ [tetrakis(ethylmethylamminoltitanium: TEMAT] and $NH_3$. Reactant sources were injected into the reactor in the order of TEMAT vapor pulse, Ar gas pulse, $NH_3$. gas pulse and Ar gas pulse. Film thickness per cycle was saturated at around 1.6 monolayer(MU per cycle with sufficient pulse times of reactant sources at 20$0^{\circ}C$. The results suggest that film thickness per cycle could be beyond 1 MLicycie in ALD, which were explained by rechemisorption mechanisms of reactant sources. The ideal linear relationship be¬tween number of cycles and film thickness is confirmed. As a results of surface limited reactions of ALD, step cover¬age was excellent. Particles caused by the gas phase reactions between TEMAT and NH3 were almost free because TEMAT was seperated from $NH_3$ by the Ar pulse. In spite of relatively low substrate temperature, carbon impurity was incorporated below 4 at%.

  • PDF

Tooth preparation design of dental laminate veneer: a review article (라미네이트 치아형성 디자인에 관한 문헌고찰)

  • Jo, Eun-Hye;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.149-157
    • /
    • 2016
  • Tooth preparation design is essential for successful laminate veneer treatment. Preservative tooth preparation limited on enamel, supra-margin advantageous for plaque control, and maintaining contact points known as a standard concept. However, the tooth preparation design has been the controversial issue. In biomechanical considerations, the incisal coverage should be decided on esthetic needs and necessity for the anterior guidance reconstruction. In occasion for sufficient enamel thickness, preparation can prolong to the palatal side but not recommended at palatal concavity. Elongation to contact point is selective option according to the cases. If an old resin restoration located at contact area, laminate veneer should cover over half area of that after surface treatment. The laminate veneer can be also selected at a partially discolored tooth root canal therapy (RCT) and at this occasion, the fiber-reinforced composite (FRC) posts are recommended.