• Title/Summary/Keyword: Surface blast

Search Result 276, Processing Time 0.029 seconds

Performance Tests of Epoxy-Coated Reinforcing Bars (에폭시 도막철근의 성능 실험연구)

  • 최완철;김채훈;신영수;홍기섭;홍영균;정일영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.158-162
    • /
    • 1994
  • Test results to evaluate the mechanical properties of epoxy-coated bars and corrosion protection characteristics of epoxy coating on the bars are described. The results show good adhesion and abrasion resistance satisfying the requirements in relevant standards. The test results also show that for a coating thickness ranging from 150${\mu}{\textrm}{m}$ to 300${\mu}{\textrm}{m}$, satisfactory results are obtained regarding bendability. Cautions shall be required when bending epoxy-coated bars at a high bending degree and at a low temperature. The results of accelerated corrosion tests show good corrosion resistance. However, surface defects from the steel itself and insufficient blast-clean process form weak points resulting blistering or disbonding of the coating. The use of epoxy-coated bars is expected to help protect corrosion of reinforcement and extend the service life of reinforced concrete structures.

  • PDF

Hydration of Granulated Blast Furnace Slag in the Presence of $CaSO_4$ ($CaSO_4$ 자극에 의한 고로수쇄 슬래그의 수화반응)

  • 송종택
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.4
    • /
    • pp.208-212
    • /
    • 1980
  • In order to clarify the mechanism of the hydration of supersulphated slag cement, the experiments of suspension hydration were performed in the mixtures of slag+CaSO4+water or NaOH solutions with a liquid/solid ratio of 10. The liquid and solid phase of the suspension was chemically analysed and discussed. In the slag-$CaSO_4$--NaOH system, $Al_2O_3$ was dissolved under high pH condition, and the ettringite was formed by a reaction of $CaSO_4$ and $Al_2O_3$ released in the solution. As hydration progressed, ettringite coated the surface of unhydrated slag grains and inhibited the hydration reaction of slag. $CaSO_4$ was not only an activator for slag hydration, but a reactant in the hydration.

  • PDF

High-impulse, Low-Power Microthruster using Liquid Propellant with High-Viscosity Fluid Plug (저온 비등 팽창유체와 고점성 유체마개를 이용한 고출력 저전력형 마이크로 분사기)

  • Kim, Sang-Wook;Kang, Tae-Goo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.868-874
    • /
    • 2002
  • A high-impulse, low-power, digital microthruster has been developed using low-boiling-temperature liquid propellant with high-viscosity fluid plug. The viscous fiction force of the fluid plug increases the blast pressure and the low-boiling-temperature liquid propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of 7$\times$13$\times$1.5㎣. A digital output impulse bit of 6.4$\times$10$^{-8}$ Nsec has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional multiple-shot microthruster.

Design, Fabrication and Performance Testing of a High-impulse, Low-Power Microthruster using Liquid Propellant with High Viscous Fluid Plug (저전력소비, 고출력, 연발형 마이크로 분사기의 설계, 제작 및 성능 시험)

  • Kim, Sang-Wook;Kang, Tae-Goo;Cho, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.59-63
    • /
    • 2001
  • A high-impulse, low-power, continuous-shot microthruster has been developed using low boiling temperature liquid-propellant with high viscous fluid-plug. The viscous friction force of the fluid-plug increases the blast pressure and the low boiling temperature liquid-propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of $7{\times}13{\times}1.5mm^{3}$. A continuous output impulse bit of $6.4{\times}10^{-8}N{\cdot}sec$ has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional continuous microthruster.

  • PDF

Effects of Burden and Free Surface on the Blast Vibration (최소저항선과 자유면의 크기가 발파진동에 미치는 영향 고찰)

  • 두준기;양형식
    • Explosives and Blasting
    • /
    • v.19 no.3
    • /
    • pp.59-65
    • /
    • 2001
  • 암반발파작업에서 발생되는 발파진동은 주변의 생활환경과 인접한 구조물에 영향을 미쳐 공해를 발생시킨다. 계단발파와 터널발파에서 발생되는 발파진동은 진동에 영향을 미치는 요소들의 일부는 동일하게 작용하고 일부는 서로 다르게 작용하여 진동의 크기가 결정된다. 일반적으로 발파진동의 크기에 영향을 미치는 요소 중에서 암반의 조건과 폭약종류, 장약량 등 제 요소가 동일한 경우에는 최소저항선 거리와 자유면의 수에 의해 발파진동이 결정되는 것으로 알려져 있다. 그러나 터널 발파에서는 최소저항선거리와 자유면의 수 외에 자유면의 크기가 발파진동의 크기를 결정하는 주된 요소로 작용하게 된다. 본고에서는 자유면의 크기가 발파진동에 미치는 영향을 고찰하여 터널발파의 진동제어방법을 제시하였다.

  • PDF

The Effects of Blasting Vibrations on the Stability of Structure by Excavation around Shaft (수갱 인접 암반 굴착시 발파진동이 구조물의 안정에 미치는 영향)

  • 김형도;임한욱;이태노
    • Tunnel and Underground Space
    • /
    • v.7 no.3
    • /
    • pp.208-220
    • /
    • 1997
  • To asses the stability of structure around shaft during the excavation of -300 ml hopper room at 2nd shaft in Jangsung mine, some measurements were made with blast monitoring, stressmeter, extensometer and inclinometers. Instrumentations proved to be reliable and data were montiored over six month period. Stressmeters were set at the points of wall and arch of inset gang(level). Induced stresses were measured with the magnitude of 2.81 kgf/$\textrm{cm}^2$(tensile stress) and -4.45kgf/$\textrm{cm}^2$(compressive stress) respectively. These values were converged after two months. The magnitude of axial force in rock bolt was measured with 1.98 ton between the points of M2(2.25m) and M3(1.5 m) but this value was assumed within allowable level. Maximum displacement was also measured with 2 mm at the dephs of 12m from surface. But this value belongs within guide level.

  • PDF

An apt material model for drying shrinkage and specific creep of HPC using artificial neural network

  • Gedam, Banti A.;Bhandari, N.M.;Upadhyay, Akhil
    • Structural Engineering and Mechanics
    • /
    • v.52 no.1
    • /
    • pp.97-113
    • /
    • 2014
  • In the present work appropriate concrete material models have been proposed to predict drying shrinkage and specific creep of High-performance concrete (HPC) using Artificial Neural Network (ANN). The ANN models are trained, tested and validated using 106 different experimental measured set of data collected from different literatures. The developed models consist of 12 input parameters which include quantities of ingredients namely ordinary Portland cement, fly ash, silica fume, ground granulated blast-furnace slag, water, and other aggregate to cement ratio, volume to surface area ratio, compressive strength at age of loading, relative humidity, age of drying commencement and age of concrete. The Feed-forward backpropagation networks with Levenberg-Marquardt training function are chosen for proposed ANN models and same implemented on MATLAB platform. The results shows that the proposed ANN models are more rational as well as computationally more efficient to predict time-dependent properties of drying shrinkage and specific creep of HPC with high level accuracy.

A Study on the Mechanical Properties of Mortar Using Steen Slag Fine Aggregate (제강슬래그 잔골재 사용 모르타르의 역학적 특성에 대한 고찰)

  • 문한영;유정훈;박영훈;강정용;정문철;송준혁
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.322-325
    • /
    • 2003
  • Recently, as quality river aggregates like sands and gravels become scarce, use of crushed stones and sands, seashore sands, and seashore gravels is increasing abruptly. And, aggregates recycled from slags and waste concretes are used. However, since the converter slag easily expands and breaks due to free lime, differently from the blast-furnace slag, it is not suitable for use as concrete aggregates. Since the atomized steel slag aggregate has slippery surface and spherical shape, the mortar flowing characteristics improved as the atomized steel slag content increases, without regard to the aggregates coarseness and water/cement ratio. The flow characteristics loss rate of the mortar manufactured from steel slag aggregates was similar to that of the mortar manufactured from washed sand only. The compact strength of the mortar manufactured from coarse PS Ball were larger than that manufactured from washing sand only.

  • PDF

Hydration of Granulated Blast Furnace Slag in the Presence of NaOH (NaOH 자극에 의한 고노수쇄 슬래그의 수화반응)

  • 송종택;대문정기(大門正機);근등련일(近藤連一)
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.3
    • /
    • pp.158-162
    • /
    • 1980
  • The experiments of suspension hydration were performed in the mixtures of slag and water or NaOH solutions which were made up with a liquid/solid ratio of 10. The liquid phase of the suspension was chemically analysed and discussed. When slag was in contact with water, CaO component was released from slag grains into the solution. The amounts of $SiO_2$ and $Al_2O_3$ liberated in the solution were very low as compared with CaO, for the impermeable coating of $SiO_2$, $Al_2O_3$-rich gel was formed on the surface of slag grains. The hydration was considered to be inhibited by this impermeable coating. The weak hydraulic property of slag was based on slowly released CaO and dissolved Na, K components which increased pH in the solution.

  • PDF

The Influence of Ground Vibration Caused by Pile Driving on Power Line Tower Foundation (항타 진동이 송전탑 기초에 미치는 영향 연구)

  • Park, Jung-Bong
    • Explosives and Blasting
    • /
    • v.27 no.2
    • /
    • pp.42-47
    • /
    • 2009
  • Ground vibrations caused by pile driving or explosive blasting can affect the stability of power line tower and its foundation. Because the characteristics of ground vibrations generally depend on the distances from the blast, the ground vibrations should be controlled by taking the distance into account. In this study, ground vibration levels were measured at the foundation of a power line tower and on ground surface adjacent to the tower. The relationships between the dominant frequencies of the ground vibrations that were measured at both locations were comparatively investigated.