• Title/Summary/Keyword: Surface acoustic wave biosensor

Search Result 5, Processing Time 0.021 seconds

Development of Surface Acoustic Wave Biosensor Using Epitaxial Lift-Off(ELO) Technology (ELO 기술을 이용한 표면 탄성파 바이오 센서의 개발)

  • 김기범;정우석;권대규;김남균;홍철운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.447-449
    • /
    • 2004
  • The purpose of this study is measured surface acoustic wave(SAW) characteristics to confirm utilization possibility as SAW sensor using new Pb(Mg$_{1}$3/Nb$_{2}$3/) $O_3$-PbTiO$_3$ (PMN-PT) piezoelectric substrate. We have tried to see if the material can be practically available as a new surface acoustic wave (SAW) biosensor to detect protein. The experimental results clarified that the frequency filtering of the central frequency of the PMN-PT substrate is a superior result to that of the LiTaO$_3$ (LT) substrate, but the result was not completely satisfactory. We know there is a problem in the design of inter-digital transducer (IDT) pattern. The waves transferred through the input terminal forms SAW which is sure to be transferred to the direction of the output terminal and the backward direction of the input terminal. This reflected wave is reiterated with SAW, which is transferred to the output direction, and so the frequency filtering gives a not good result. The electromechanical coupling coefficient of the PMN-PT substrate is excellent, and we can use it as a SAW sensor, in the near future, provided that there will be a new IDT design to increase the frequency filtering.

  • PDF

Surface Acoustic Wave Characteristics of Piezoelectric Materials and Protein Immobilization (압전 재료의 탄성표면파 특성과 단백질의 고정화)

  • Chong, Woo-Suk;Hong, Chul-Un;Kim, Gi-Beum
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.166-171
    • /
    • 2006
  • In this study, in using a piezoelectric material of $Pb(Mg_{1/3}Nb_{2/3})O_3-PbTiO_3$ (PMN-PT), which has a high electromechanical coupling coefficient, we have tried to study about this material can be practically available as a new biosensor to detect protein by using surface acoustic wave (SAW). As the results, the filtering of the center frequency of the PMN-PT substrate is a superior result to that of the $LiTaO_3$ (LT) substrate, but the result was not completely satisfactory. Also this study attempts to develop a sensing method to detect mismatched DNA in order to diagnose cancer. We could directly immobilize the MutS to the NTA using the EDC solution. But, we immobilized MutS using nickel and it is judged that is more effective method to detect mismatched DNA.

Development of wireless/battery-free Love wave biosensor (무선/무전원 러브파 바이오센서 개발)

  • Nam, Min-Woo;Oh, Hae-Kwan;Lee, Kee-Keun;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1545_1546
    • /
    • 2009
  • This paper reports a novel wireless love-wave biosensor on $41^{\circ}$ YX $LiNbO_3$ piezoelectric substrate and $SiO_2$ guiding layer for Immunoglobulin G (IgG) detection by protein binding. Different from the traditional biosensors based on surface acoustic wave (SAW) oscillator structured by delay line/resonators, a 440MHz reflective delay line consists of SPUDTs and three reflectors placed on $41^{\circ}$ YX $LiNbO_3$ in a row was fabricated as the sensor element. Good linearity, reproducibility, and high sensitivity were observed in the IgG concentration range 1~65nM. Unique advantages as high sensitivity, passive and simple measurement system are present over currently available other biosensors.

  • PDF

A Biomolecular Sensing Platform Using RF Active System

  • Kim, Sang-Gyu;Lee, Hee-Jo;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.227-233
    • /
    • 2012
  • This paper describes a novel and compact biosensing platform using an RF active system. The proposed sensing system is based on the oscillation frequency deviation due to the biomolecular binding mechanism on a resonator. The impedance variation of the resonator, which is caused by a specific biomolecular interaction results in a corresponding change in the oscillation frequency of the oscillator so that this change is used for the discrimination of the biomolecular binding, along with concentration variation. Also, a Surface Acoustic Wave (SAW) filter is utilized in order to enhance the biosensing performance of our system. Because the oscillator operates at the skirt frequency range of the SAW filter, a small amount of oscillation frequency deviation is transformed into a large variation in the output amplitude. Next, a power detector is used to detect the amplitude variation and convert it to DC voltage. It was also found that the frequency response of the biosensing system changes linearly with three streptavidin concentrations. Therefore, we expect that the proposed RF biosensing system can be applied to bio/medical applications capable of detecting a nano-sized biomolecular interaction.