• 제목/요약/키워드: Surface Water Temperature

검색결과 2,831건 처리시간 0.032초

Landsat ETM+영상의 지표면온도와 NDVI 공간을 이용한 광역 증발산량의 도면화 (Regional Scale Evapotranspiration Mapping using Landsat 7 ETM+ Land Surface Temperature and NDVI Space)

  • 나상일;박종화
    • 한국농공학회논문집
    • /
    • 제50권3호
    • /
    • pp.115-123
    • /
    • 2008
  • Evapotranspiration mapping using both meteorological ground-based measurements and satellite-derived information has been widely studied during the last few decades and various methods have been developed for this purpose. It is significant and necessary to estimate regional evapotranspiration (ET) distribution in the hydrology and water resource research. The study focused on analyzing the surface ET of Chungbuk region using Landsat 7 ETM imagery. For this process, we estimated the regional daily evapotranspiration on May 8, 2000. The estimation of surface evapotranspiration is based on the relationship between Temperature Vegetation Dryness Index (TVDI) and Morton's actual ET. TVDI is the relational expression between Normalized Difference of Vegetation Index (NDVI) and Land Surface Temperature (LST). The distribution of NDVI corresponds well with that of land-use/land cover in Chungbuk. The LST of several part of city in Chungbuk region is higher in comparison with the averaged LST. And TVDI corresponds too well with that of land cover/land use in Chungbuk region. The low evapotranspiration availability is distinguished over the large city like Cheongju-si, Chungju-si and the difference of evapotranspiration availability on forest and paddy is high.

군사용 밀폐공간내의 화재시 단일 증발액적에 의한 방재특성 연구 (The study of a fire fighting characteristic by a Single Evaporating Droplet in the case of a fire of military enclosure space)

  • 이진호;방창훈;김정수
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.207-217
    • /
    • 2000
  • A fire fighting characteristic by a single evaporating droplet in the case of a fire of military enclosure space was studied experimentally. Transient cooling of solid surface by water droplet evaporation has been investigated through controlled experiments using a heated brass cylinder. Quantitative predictions of droplet evaporation time and in-depth transient temperature distribution in solid have been made. The particular interest was in the removal of thermal energy from the heated cylinder by evaporative cooling. A $10{\mu}1$ single droplet is deposited on a horizontal brass surface with initial temperatures in the range of $90^{\circ}C{\sim}130^{\circ}C.$ The results can be summarized as follows; Evaporating droplet was divided into three different configuration. Evaporation time was predicted as a function of initial surface temperature ($t_c=492.62-6.89T_{s0}+0.0248T_{s0}^2).$ The contact temperature was predicted as a function of initial surface temperature( $T_{i}$=0.94 $T_{s0}$+1.4), The parameter ${\beta}_o$ was predicted as a function of initial surface temperature( ${\beta}_0$ : 0.O0312 $T_{s0}+0.932$)>)>)

  • PDF

Prediction of Vertical Sea Water Temperature Profile in the East Sea Based on Machine Learning and XBT Data

  • Kim, Young-Joo;Lee, Soo-Jin;Kim, Young-Won
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권11호
    • /
    • pp.47-55
    • /
    • 2022
  • 최근 우리나라에서도 인공지능 모델을 이용한 수온예측 관련 연구가 활발히 진행되고 있으나 한반도 주변 해역의 수온을 예측한 대부분의 연구는 주로 해수면 온도 예측에 중점을 두고 진행되었다. 반면 본 연구는 XBT(eXpendable Bathythermograph, 소모성 연직수온측정기) 데이터와 기계 학습 모델(RandomForest, XGBoost, LightGBM)을 사용하여 잠수함 작전 및 대잠전(Anti-Submarine Warfare)에 있어서 군사적으로 중요한 동해의 수직 수온분포를 예측하였다. 동해 특정해역의 해수면부터 수심 200m까지 측정된 XBT 데이터를 이용하여 모델을 학습시키고 절대 평균 오차(MAE, Mean Absolute Error)와 수직 수온분포 그래프를 통해 예측정확도를 평가하였다.

한국 남해의 초겨울 해황과 관련한 표층 부유물질의 분포 (Suspended Particulate Matter of the Surface Water in Relation to the Hydrography in the South Sea of Korea in Early Winter)

  • 최용규
    • 한국환경과학회지
    • /
    • 제14권11호
    • /
    • pp.1063-1069
    • /
    • 2005
  • 2004년 12월 2일부터 8일까지 한국 남해의 표층 부유물질의 분포를 초겨울의 해황과 관련하여 조사하였다. 쓰시마와 제주도를 잇는 지선을 중심으로 전선이 형성되었으며, 이 전선을 중심으로 한국 남해의 연안수와 외양의 쓰시마난류수로 구분되었다. 연안역은 표층에서 저층까지 거의 균일한 수괴 분포를 보였으며, 외양은 성층이 형성되어 있었다. 그리고 부유물질은 연직혼합된 연안역에서는 5.0-6.5 mg/l였으며, 성층이 형성된 외양역은 4.5-5.0 mg/1의 분포를 나타내었다. 초겨울 한국 남해는 표면 냉각 효과와 바람에 의해서 저층의 부유물질이 충분히 재부유할 수 있는 환경이었음을 나타내고 있었다. 또한 관측 기간동안 비록 조류가 비교적 약한 소조기 이었음에도 불구하고 열플럭스에 의한 냉각효과와 바람에 의한 혼합 효과가 강하여 표층과 저층이 혼합하기에 용이하였음을 나타내었다. 이에 따라 수심이 얕은 연안역에서는 저층 퇴적물의 재부유에 의해서 부유 물질이 증가될 수 있음을 시사하고 있었다.

발수가공 시 전자빔 조사가 화학재생 폴리에스터 직물의 발수효과와 내세탁성에 미치는 영향 (Effects of E-beam Irradiation on the Water-repellency and Washing Durability of the Water-repellent Finished Chemically-recycled PET(CR-PET) Fabrics)

  • 이선영;손한글;임성찬;이형달;이승구
    • 한국염색가공학회지
    • /
    • 제27권2호
    • /
    • pp.119-125
    • /
    • 2015
  • The effects of e-beam irradiation on water-repellency and washing durability of water-repellent finished chemically-recycled PET(CR-PET) fabrics were investigated. As results, more doses of e-beam irradiation damaged the fabric surface more severely. It was thought because the high densed energy was formed, where the more e-beam was converged. The contact angle measurement showed that as the dose of e-beam irradiation increased, water wettability of the CR-PET fabric increased slightly. It was thought to be due that the surface etching by e-beam irradiation let water droplet permeate into the fabric surface better. The concentration of the water-repellent finishing agent was more important factor than curing temperature as finishing parameter. It was considered because the water-repellent finishing agent used in this study got to cure sufficiently at low temperature. Consequently, e-beam irradiation improved the washing durability of water-repellent finishing on the CR-PET fabrics.

컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성 (Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

Impact of Water Quality Parameters on the Disinfection of Total Coliform with Chlorine Dioxide

  • Lee Yoon-Jin
    • 한국환경보건학회지
    • /
    • 제32권3호
    • /
    • pp.215-221
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine dioxide, in order to assess the optimal disinfection procedure for drinking water treatment and distribution systems. This research focus on a number of factors, including the dosage of disinfectant, contact time, pH, temperature and DOC. Water samples were taken from the outlet of a settling basin at a conventional surface water treatment system. As the pH increased in the range of pH 6-9, the bactericidal effects of disinfectants decreased. Changes in levels of pH did not significantly after the disinfection effect of chlorine dioxide for total coliform. With an increase in temperature, there was a subsequent increase in the bactericidal effects of disinfectants. Thus, it is evident that a decrease in temperature will higher the CT values required to inactivate coliform for during the winter. DOC addition can also reduce total coliform inactivation. DOC is the most significant variable in total coliform inactivation with chlorine dioxide.

수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석 (Mixing Zone Analysis on Outfall Plume considering Influent Temperature Variation)

  • 김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.247-253
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on "how to dispose the treated municipal water and wastewater in harbor" brings peoples′ concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water and tidal changes, CORMIX(Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

  • PDF

韓國 南海의 水溫과 분의 變動係數 (THE VARIATION COEFFICIENT OF WATER TEMPERATURE AND SALINITY IN THE SOUTHERN SEA OF KOREA)

  • 김복기
    • 한국해양학회지
    • /
    • 제17권2호
    • /
    • pp.74-82
    • /
    • 1982
  • 1968-1980年의 韓.日共同海洋調査點中 韓國側 63個定點의 海洋調査資料를 使用하여 月別 水溫 및 분의 變動係數를 分析 硏究한 缺課의 要約은 다음과 같다. 變動係數는 水溫과 분의 前線域이나 혹은 躍層形成海域에서 크게 나타났다. 水溫의 變動係數는 각 水塊의 勞力이 가장 强한 時期에 最大値를 나타냈다(對馬 暖流와 黃海暖流域의 夏季 中層에서, 南海岸沿岸水 및 西海南部域의 冬季의 全層 에서 最大). 鹽分의 變動係數는 東支那海 低鹽水의 影響을 많이 받는 夏季에 暖流系水의 表層水에서 크게 나타나며, 沿岸水 및 西海南部域에서는 暖流系水値의 1/2정도였다.

  • PDF

실내 수공간 도입에 따른 온열 환경 변화 분석 (Analysis of Thermo Environment Change by Introduction of Indoor Water Space)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.