• 제목/요약/키워드: Surface Water Temperature

검색결과 2,819건 처리시간 0.036초

Semi-Rig, Pontoon 구역 표면 결로 예방 설계 (Semi-Rig, Anti-condensation design on steel surface in pontoon area)

  • 서동재;박상언;노정환;심학무
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2017년도 특별논문집
    • /
    • pp.105-108
    • /
    • 2017
  • Condensation is one of the common issues which we can easily see in everyday life. For example, the surface of glasses with cold water is easily moisturized. This wet surface gives us uncomfortable feeling and is sometimes dangerous because it is slippery. As the safety on working space is one of the most important issue on offshore project, condensation is also important matter to take care of with precaution. Since the bottom of vessel or offshore facility is submersed in the water, the risk of having condensate on the steel surface is getting higher because sea water temperature is normally lower than ambient temperature. And if there is any electric equipment or person working in that space, condensation is normally not allowed. The pontoon of semi-submersible drilling rig is such a space which is submersed, with electric and mechanical equipments and person working periodically. To prevent condensation in pontoon, study was conducted by checking several cases.

  • PDF

필라멘트 와인딩 복합재의 환경노화에 따른 기계적물성 평가 (Behaviors of Mechanical Properties of Filament-Winding-Laminated Composites due to Environmental Aging)

  • 최낙삼;윤영주;이상우;김덕재
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.31-35
    • /
    • 2006
  • Degradation characteristics of filament-winded composites due to accelerated environmental aging have been evaluated under high temperature, water immersion and thermal impact conditions. Two kinds of laminated composites coated by an urethane resin have been used: carbon-fiber reinforced epoxy(T700/Epon-826, CFRP) and glass-fiber reinforced phenolic (E-glass/phenolic, GFRP). For tensile strength of $0^{\circ}$ composites, CFRP did high reduction by 25% under the influence of high temperature and water while CFRP showed little degradation. However for water-immersed $90^{\circ}$ composites both CFRP and GFRP showed high reduction in tensile strength. Bending strength and modulus of $90^{\circ}$ composites were largely reduced in water-immersion as well as high temperature environment. Urethane coating on the composite surface improved the bending properties by 20%, however hardly showed such improvement for water-immersed $90^{\circ}$ composites.

  • PDF

저온 Si계 에피 성장기술에서 실험계획법에 의한 in-situ H$_2$ bake 및 GeH$_4$ clean 공정 최적화 (The process optimization of in-situ H$_2$ bake and GeH$_4$ clean in low temperature Si epitaxy using design of experiment)

  • 이경수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.54-58
    • /
    • 1994
  • H$_2$ bake and GeH$_4$ clean are used as a in-situ pre-clean method in low temperature Si based epitaxial growth technology using rapid thermal processing chemical vapor deposition (RTPCVD). In this paper, the H$_2$ bake and GeH$_4$ clean processes are optimized for low surface defect density using Taguchi method. In H$_2$ bake process, the epitaxial growth temperature affects dominantly on the surface defect density, and the next affecting factors are H$_2$ bake temperature and rinse time in de-ionised water. In GeH$_4$ clean process, GeH$_4$ clean temperature affects most strongly on the surface defect density, and the minor factor is GeH$_4$flow rate. The optimum process conditions predicted fly Taguchi method agree well with tile experimental data in both in-situ clean processes.

한국남해동부해역에서 수온이 멸치와 김 생산량에 미치는 영향 (Effect of Temperature on Catches of Anchovy and Laver In Eastern part of South Sea of Korea)

  • 김현주;권철휘
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2003년도 추계학술발표회
    • /
    • pp.175-180
    • /
    • 2003
  • 수온과 멸치와 김 생산량의 관계를 규명하기 위해, $1980\~2002$년 한국 남해 동부해역에서 생산량과 해양관측자료를 분석하였다. 한국 남해 동부해역에서 년간 멸치와 김 생산량은 들 다 해마다 변동은 있으나 전반적으로 점차 증가하는 추세를 보였다. 멸치와 김 생산량은 해양환경 특히, 수온과 밀접한 관계가 있는 것으로 나타났다. 즉, 표층은 평년보다 높고, $0\~20m$에서의 수온은 평년보다 낮았을 때 특히 저층에 약 $15^{\circ}C$ 이하의 저온수가 존재했을 때, 들 다 생산량이 저조하였다.

  • PDF

토양의 온도와 수분이 크리핑 벤트그래스(Agrostis palustris Huds) 생육에 미치는 영향 (Effect of Temperature and Water Content of Soil on Creeping Bentgrass(Agrostis palustris Huds) Growth)

  • 임승현;정준기;김기동;주영규
    • 아시안잔디학회지
    • /
    • 제23권2호
    • /
    • pp.229-240
    • /
    • 2009
  • 여름철 고온 다습한 우리나라 기온에서 토양 온도와 수분은 잔디의 생리학적 변화를 초래하며, 특히 한지형 잔디생육은 우리나라 여름철 기후의 특이성에 많은 영향을 받는다. 본 실험은 크리핑 벤트그래스(Agrostispalustris Huds.)를 이용하여 고온의 조건에서 각기 다른 토양 수분함량 조건에서의 한지형 잔디생육을 관찰하였다. 구체적인 실험 방법으로는 수분함량과 온도에 따른 bentgrass의 생육 및 생리적 스트레스 반응을 평가하였다. 모의 USGA(United State of Golf Association) 그린 조건에서의 토양 온도 및 열 특성 실험 결과 수분이 거의 없는 건조 상태에서의 토양 온도는 $34^{\circ}C$로 발열 했을 때 토양 표면 온도가 $80^{\circ}C$까지 올라가는 것을 알 수 있었다. 반면, 과수분 조건에서 $34^{\circ}C$ 발열을 했을 때에는 건조 조건에 비해 상대적으로 $10^{\circ}C$가 낮은 것을 알 수 있었다. 실험 포장에서의 온도와 수분에 따른 열 특성 변화는 관수시기와 무관하게 처리구 모두에서 관수 후에 열전도도(thermal conductivity), 열 확산성(thermal diffusivity), 및 토양 온도가 증가하였다. 이는 수분이 공기에 비해 상대적으로 높은 열전도도를 갖기 때문으로 사료된다. 또한, 본 실험에서 관수 초기에는 과수분 조건에 비해 수분 결핍 조건에서 토양 온도의 증가를 보였으며, 시간이 지남에 따라 과수분 조건에서 더 높은 토양 온도의 증가를 확인하였다. 즉, 토양 온도는 과수분 조건에서 열전도에 의해 높아져 잔디의 생육에 영향을 미친다. 이는 잔디 표면부 온도가 높은 시각대의 과도한 관수는 여름철 잔디의 생육에 부정적 영향을 미치며, 소나기 등에 의한 일시 침수 시 지반배수의 불량은 잔디 생육에 치명적인 요인이 될 수 있다는 것을 의미한다.

A novel Fabry-Perot fiber optic temperature sensor for early age hydration heat study in Portland cement concrete

  • Zou, Xiaotian;Chao, Alice;Wu, Nan;Tian, Ye;Yu, Tzu-Yang;Wang, Xingwei
    • Smart Structures and Systems
    • /
    • 제12권1호
    • /
    • pp.41-54
    • /
    • 2013
  • Concrete is known as a heterogeneous product which is composed of complex chemical composition and reaction. The development of concrete thermal effect during early age is critical on its future structural health and long term durability. When cement is mixed with water, the exothermic chemical reaction generates hydration heat, which raises the temperature within the concrete. Consequently, cracking may occur if the concrete temperature rises too high or if there is a large temperature difference between the interior and the exterior of concrete structures during early age hydration. This paper describes the contribution of novel Fabry-Perot (FP) fiber optic temperature sensors to investigate the thermal effects of concrete hydration process. Concrete specimens were manufactured under various water-to-cement (w/c) ratios from 0.40 to 0.60. During the first 24 hours of concreting, two FP fiber optic temperature sensors were inserted into concrete specimens with the protection of copper tubing to monitor the surface and core temperature change. The experimental results revealed effects of w/c ratios on surface and core temperature developments during early age hydration, as well as demonstrating that FP fiber optic sensors are capable of capturing temperature variation in the concrete with reliable performance. Temperature profiles are used for calculating the apparent activation energy ($E_a$) and the heat of hydration (H(t)) of concrete, which can help us to better understand cement hydration.

물과 알루미나 나노유체 분무의 분무냉각특성 비교 (Comparison of the Characteristics of Spray Cooling between Water and Nanofluid Sprays)

  • 강보선;이신표
    • 한국분무공학회지
    • /
    • 제19권2호
    • /
    • pp.88-93
    • /
    • 2014
  • Nanofluids is that metallic or nonmetallic nanometer-sized particles are dispersed in liquid and they can be used in various fields to increase the heat transfer rate. This study conducted experiments to evaluate whether the cooling efficiency of nanofluids is better than that of water in spray cooling. A heated surface was designed and fabricated to make the temperature distribution be linear, which was confirmed by three thermocouple measurements under the heated surface. Spray cooling experiments were conducted using water, 0.2% wt. (weight), and 0.5% wt. $Al_2O_3$ nanofluids at the pressure of 0.2 MPa and 0.3 MPa. Based on the results, it is shown that the cooling efficiency of nanofluids is higher than that of water especially in the region of single phase heat transfer. As a result, we can expect that nanofluids can be used as efficient coolants in the cooling of electronic packages where the temperature of the heated surface is not high enough for boiling incipience.

Behavior of Hydroxide Ions at the Water-Ice Surface by Low Energy Sputtering Method

  • Kim, S.Y.;Park, E.H.;Kang, H.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.338-338
    • /
    • 2011
  • The behavior of hydroxide ions on water-ice films was studied by using $Cs^+$ reactive ion scattering (RIS), low energy sputtering (LES) and temperature-programmed desorption (TPD). A $Cs^+$ beam of a low kinetic energy (<100 eV) from $Cs^+$ ion gun was scattered at the film surface, and then $Cs^+$ projectiles pick up the neutral molecules on the surface as $Cs^+$-molecule clusters form (RIS process). In LES process, the preexisting ions on the surface are desorbed by the $Cs^+$ beam impact. The water-ice films made of a thick (>50 BL) $H_2$O layer and a thin $D_2O$ overlayer were controlled in temperatures 90~140K. We prepared hydroxide ions by using Na atoms which proceeded hydrolysis reaction either on the ice film surface or at the interface of the $H_2O$ and $D_2O$ layers.[1] The migration of hydroxide ions from the $H_2O/D_2O$ interface to the top of the film was examined as afunction of time. From this experiment, we show that hydroxide ions tend to reside at the water-ice surface. We also investigated the H/D exchange reactions of $H_2O$ and $D_2O$ molecules mediated by hydroxide ions to reveal the mechanism of migration of hydroxide to the ice surface.

  • PDF

Fiber network with superhydrophilic Si-DLC coating

  • 김성진;문명운;이광렬;김호영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.363-363
    • /
    • 2010
  • The high capillarity of a plastic fiber network having superhydrophilic Si-DLC coating is studied. Although the superhydrophilic surface maximize wetting ability on the flat surface, there remains a requirement for the more wettable surface for various applications such as air-filters or liquid-filters. In this research, the PET non-woven fabric surface was realized by superhydrophilic coating. PTE non-woven fabric network was chosen due to its micro-pore structure, cheap price, and productivity. Superhydrophobic fiber network was prepared with a coating of oxgyen plasma treated Si-DLC films using plasma-enhanced chemical vapor deposition (PECVD). We first fabricated superhydrophilic fabric structure by using a polyethylene terephthalate (PET) non-woven fabric (NWF) coated with a nanostructured films of the Si-incorporated diamond-like carbon (Si-DLC) followed by the plasma dry etching with oxygen. The Si-DLC with oxygen plasma etching becomes a superhydrophilic and the Si-DLC coating have several advantages of easy coating procedure at room temperature, strong mechanical performance, and long-lasting property in superhydrophilicity. It was found that the superhydrophobic fiber network shows better wicking ability through micro-pores and enables water to have much faster spreading speed than merely superhydrophilic surface. Here, capillarity on superhydrophilic fabric structure is investigated from the spreading pattern of water flowing on the vertical surface in a gravitational field. As water flows on vertical flat solid surface always fall down in gravitational direction (i.e. gravity dominant flow), while water flows on vertical superhydrophilic fabric surface showed the capillary dominant spreading.

  • PDF

경사냉각면에 따른 함수정방형내의 동결현상에 관한 실험적 연구 (An experimental study on freezing phenomena of water saturated square cavity with inclined cold surface)

  • 이춘희;김종준;김병철
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.435-445
    • /
    • 1997
  • It was studied the phenomena of transient freezing of an inclined water-saturated enclosure. One side of the test section was cooled and the other sides were insulated. The effects of the initial temperature, the inclination angle on the temperature field and the shape of the ice-water interface were observed. In the beginning of freezing, with increasing the inclination angle the freezing rate was increased and in the stable density layer centered $4^{\circ}C$, the freezing was fast as the convective fluid flow became small. When the initial temperature was above the $4^{\circ}C$, the frozen thickness in the upper part of inclined surface was thinner than that in the lower part, but with time the frozen thickness of upper part was thicker than that of lower part, below the $4^{\circ}C$, the frozen thickness in the upper part was thicker than that of lower part from the begining, and above the $8^{\circ}C$ in the beginning upper part was thinner with concave, but with time thicker the upper part, vanishing concave.