• 제목/요약/키워드: Surface Water Temperature

검색결과 2,819건 처리시간 0.029초

The Effect of Water-Filtered Infrared-A (wIRA) on Body Core and Body Surface Temperatures in Anesthetized Rabbits Maintained with Isoflurane

  • Geonho Choi;Dongseok Kim;Eungmo Tae;Ilgwon Jung;Sang-Kwon Lee;Won-Jae Lee;Sung-Ho Yun;Young-Sam Kwon;Min Jang
    • 한국임상수의학회지
    • /
    • 제40권1호
    • /
    • pp.44-49
    • /
    • 2023
  • The purpose of this study was to evaluate body temperature changes in rabbits anesthetized using water-filtered infrared-A (wIRA). Ten rabbits were used for this study. For the experimental group (wIRA group; wG, n = 5), the experimental equipment was used and irradiated using wIRA. The control group (CG, n = 5) did not have any warming device. There were no significant differences in heart rate, respiration rate, and end tidal CO2 (EtCO2) between wG and CG. After 80 min, the core body temperature of wG rabbits was significantly higher than that of CG rabbits. The surface body temperature was significantly higher while receiving wIRA support at all time points after 5 min. In conclusion, in rabbits under inhalation anesthesia, the surface body temperature was better maintained than the core body temperature when using wIRA.

EHC 기반 Urea-SCR 시스템 히터 표면온도 분포의 1-D 모델링 (1-D Modeling of Heater Surface Temperature Distribution in EHC-based Urea-SCR System)

  • 박선홍;손지현;문석수;오광철;장성욱;박성서
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.11-17
    • /
    • 2022
  • In upcoming Post Stage-V and Tier 5 regulations of construction machineries, nitrogen oxide (NOx) emissions are strictly limited in cold start conditions. In response to this, a method of improving NOx conversion efficiency has been applied by installing an electric heating catalyst (EHC) in front of conventional urea-SCR systems so that the evaporation and thermal decomposition of urea-water solution can be promoted in cold start conditions. In this strategy, the evaporation and thermal decomposition of urea-water solution and corresponding NOx conversion efficiency are governed by temperature conditions inside the EHC. Therefore, characterizing the temperature distribution in the EHC under various operating conditions is crucial for the optimized operation and control of the EHC in Urea-SCR systems. In this study, a 1-D modeling analysis was performed to predict the heater surface temperature distribution in EHC under various operating conditions. The reliability of prediction results was verified by comparing them with measurement results obtained using an infrared (IR) camera. Based on 1-D analysis results, the effects of various EHC operation parameters on the heater surface temperature distribution were analyzed and discussed.

여수 엑스포 해역의 생물.화학적 해양환경 특성 (A Study on the Marine Biological and Chemical Environments in Yeosu Expo Site, Korea)

  • 노일현;오석진;박종식;안영규;윤양호
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제13권1호
    • /
    • pp.1-11
    • /
    • 2010
  • 2012 여수 엑스포 부지인 신항해역의 생물해양학적 환경특성과 이를 조절하는 물리 화학적 요인의 경시적인 변동특성을 파악하기 위해 1개 정점을 대상으로 2006년 4월부터 2007년 12월까지 일주일 간격을 원칙으로 현장조사를 실시하였다. 수온은 표층에서 $6.8{\sim}27.8^{\circ}C$, 저층에서 $6.3{\sim}25.9^{\circ}C$의 범위를, 염분은 표층에서 12.8~33.0 psu의 범위를, 저층에서 25.2~33.6 psu의 범위를 보였다. 강우가 집중된 하계에 급격하게 염분이 낮아지면서 표·저층사이에 강한 염분약층이 형성되었다. 용존무기질소(DIN)는 표층에서 $1.36{\sim}82.7{\mu}M$, 저층에서 $1.27{\sim}25.2{\mu}M$의 범위를, 인산성 인은 표층에서 $0.06{\sim}2.13{\mu}M$, 저층에서 $0.07{\sim}1.38{\mu}M$의 범위를, 규산성 규소는 표층에서 $1.68{\sim}52.0{\mu}M$, 저층에서 $1.37{\sim}30.7{\mu}M$의 범위를 나타내었으며, 영양염류는 계절적으로 강우량이 많은 시기와 저수온기에 높고, 춘계와 추계에 크게 감소하였다. N/P ratio는 표층에서 4.43~325, 저층에서 3.57~321의 범위로 변동하였으며, 강우가 집중되는 시기에 급격히 증가하고, 그 외 시기에는 16 내외의 값을 나타내었다. $Chlorophyll{\alpha}$는 표층에서 $0.46{\sim}65.0{\mu}g$ $L^{-1}$, 저층에서 $0.71{\sim}15.0{\mu}g$ $L^{-1}$의 범위를 나타내었으며, 저수온기에는 낮은 농도로 유지되다 고수온기에 생물량이 급격히 증가하였다. 주성분분석과 중회귀분석 결과, 본 연구해역의 물리 화학적 및 생물학적 요인의 경시적인 변동은 염분의 변화로 표현되는 담수유입에 의해 크게 지배되는 구조를 보이고, 공급된 무기영양염은 식물플랑크톤의 흡수 동화를 통해 비교적 효율적으로 조절되고 있으며, 또한 저수온기에는 무기화과정과 영양염 순환을 통해 재생산된 영양염이 이 해역의 환경구조에 큰 영향을 미치는 것으로 판단되었다.

Consideration of NDVI and Surface Temperature Calculation from Satellite Imagery in Urban Areas: A Case Study for Gumi, Korea

  • Bhang, Kon Joon;Lee, Jin-Duk
    • 한국측량학회지
    • /
    • 제35권1호
    • /
    • pp.23-30
    • /
    • 2017
  • NDVI (Normalized Difference Vegetation Index) plays an important role in surface land cover classification and LST (Land Surface Temperature Extraction). Its characteristics do not full carry the information of the surface cover typically in urban areas even though it is widely used in analyses in urban areas as well as in vegetation. However, abnormal NDVI values are frequently found in urban areas. We, therefore, examined NDVI values on whether NDVI is appropriate for LST and whether there are considerations in NDVI analysis typically in urban areas because NDVI is strongly related to the surface emissivity calculation. For the study, we observed the influence of the surface settings (i.e., geometric shape and color) on NDVI values in urban area and transition features between three land cover types, vegetation, urban materials, and water. Interestingly, there were many abnormal NDVI values systematically derived by the surface settings and they might influence on NDVI and eventually LST. Also, there were distinguishable transitions based on the mixture of three surface materials. A transition scenario was described that there are three transition types of mixture (urban material-vegetation, urban material-water, and vegetation-water) based on the relationship of NDVI and LST even though they are widely distributed.

첨가제로 아세트산 나트륨-3수화물을 함유한 물 액적의 증발 특성 (Evaporation Characteristics of a Water Droplet Containing Sodium Acetate Trihydrate as an Additive)

  • 박재만;신창섭
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.61-68
    • /
    • 2004
  • The evaporation phenomena of waterr droplet which has sodium acetate trihydrate($CH_3COONa{\cdot}3H_2O$) as a fire suppression additive were studied. Solutions of sodium salt up to 50% and heated stainless-steel surface were used in the experiment. The evaporation process was recorded using a charge-coupled-device camera at 120 frames per second. The average evaporation rate of the sodium acetate trihydrate soluation was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid film and change of surface tension. The variation of liquied film diameter was measured by time and it was increased by the hot surface temperature increase.

급속 열처리 시스템을 위한 물/공기 액적류 충돌 제트의 냉각 특성에 관한 연구 (Cooling Performance of Air/Water Mist Jet Impinging for a Rapid Thermal Annealing System)

  • 이준경
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.68-74
    • /
    • 2015
  • In the present work, a series of numerical calculations have been conducted on the cooling of a hot surface using an air/water mist jet. In some cooling processes, such as in the glass-tempering process, direct contact between the cold water drops and the hot surface should be avoided, because this may cause surface cracks due to the sharp temperature gradients. Thus, the main focus of this study is finding the appropriate operating conditions for maximum cooling without direct contact between the drops and the surface. A series of numerical experiments have been performed, and, at the same time, those results were compared with those of the previous experiments for verification purposes. The effects of droplet impinging velocity, hot plate temperature, and liquid loading ratio for mono-dispersed drops of various sizes were studied in detail.

증발냉각에 의한 공랭 응축기의 성능향상 가능성에 관한 연구 (Cooling Enhancement Potential of an Air-Cooled Condenser by Evaporative Cooling)

  • 이대영;백영진;김영일
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This paper describes the potential advantages in applying evaporative cooling to air-cooled condensers. The cooling characteristics of an air-cooled condenser with its surface fully covered with thin water film are investigated and compared with that of an air-cooled condenser with usual dry surface. By applying the evaporative cooling, the cooling performance of the condenser is shown to improve enormously. When the outdoor air is 35$^{\circ}C$ and 40% in relative humidity, the condensing temperature of the refrigerant is decreased by 2$0^{\circ}C$. Even when the incoming air is fully saturated with water vapor, the evaporation from the wet surface occurs to cause a decrease in the condensing temperature by 1$0^{\circ}C$. The main reason for this improvement is assessed as the addition of an efficient cooling mechanism which is the water evaporation resulting in latent heat absorption.

2011-2012년 서해 보령연안 수온의 시공간적 변동 (Temporal and Spatial Variations in Sea Surface Temperature Around Boryeong off the West Coast of Korea From 2011-2012)

  • 추효상;윤은찬
    • 해양환경안전학회지
    • /
    • 제23권5호
    • /
    • pp.497-512
    • /
    • 2017
  • 2011~2012년 보령연안 수온의 시공간적 변동특성을 장기 연속수온관측 자료를 이용하여 분석하였다. 수온은 반일 또는 일일의 단주기 변동이 전 계절에 탁월하고 그 진폭은 하계와 춘계에 크고 추계에 작다. 수온과 기온의 연변동 진폭은 기온 $12.9^{\circ}C$, 수온 $10.9^{\circ}C$로 기온이 더 크며, 연변동 최고위상은 기온 8월 2일, 수온 8월 22일로 기온이 20일 앞선다. 수온의 연변동 진폭은 원산도와 대천항 연안에서 가장 크다. 수온변동 중 일일주기는 대천항과 무창포항, 반일주기는 원산도 주변 협수로에서 탁월하며, 대천천 하구는 천해조 비율이 높다. 표층수온과 기온은 대체로 풍향 변동에 따라 변동한다. 하천수가 방출되면 수온은 상승 후 하강 또는 하강 후 상승한다. 수온 탁월주기는 0.5일, 1.0일, 15일 주기와 7~10일 전후이다. 수온변동특성에 따라 해역을 분류하면 (1)원산도 남동연안의 혼합수역 (2)삽시도~용도, 장고도~삽시도, 장고도~안면도 남쪽의 서쪽 외해수역 (3)용도~독산의 남쪽 외해수역 (4)송도~대천항~무창포항의 조간대 연안수역으로 구분된다.

LSTM을 이용한 한반도 근해 이상수온 예측모델 (Abnormal Water Temperature Prediction Model Near the Korean Peninsula Using LSTM)

  • 최혜민;김민규;양현
    • 대한원격탐사학회지
    • /
    • 제38권3호
    • /
    • pp.265-282
    • /
    • 2022
  • 해수면 온도(Sea surface temperature, SST)는 지구시스템에서 해양의 순환과 생태계에 큰 영향을 주는 요소이다. 지구온난화로 한반도 근해 해수면 온도에 변화가 생기면서 이상 수온(고수온, 저수온) 현상이 발생하여 해양생태계와 수산업 피해를 지속적으로 발생시키고 있다. 따라서 본 연구는 한반도 근해 해수면 온도를 예측하여 이상 수온 현상 예측으로 피해를 예방하는 방법론을 제안한다. 연구 지역은 한반도 근해로 설정하여 동시간대 해수면 온도 데이터를 사용하기 위해 Europe Centre for Medium-Range Weather Forecasts (ECMWF)의 ERA5 자료를 사용하였다. 연구방법으로는 해수면 온도 데이터의 시계열 특징을 고려하여 딥러닝 모델 중 시계열 데이터 예측에 특화된 Long Short-Term Memory (LSTM) 알고리즘을 이용하였다. 예측 모델은 1~7일 이후 한반도 근해 해수면 온도를 예측하고 고수온(High water temperature, HWT) 혹은 저수온(Low water temperature, LWT) 현상을 예측한다. 해수면 온도 예측 정확도 평가를 위해 결정계수(Coefficient of determination, R2), 평균제곱근 편차(Root Mean Squared Error, RMSE), 평균 절대 백분율 오차(Mean Absolute Percentage Error, MAPE) 지표를 사용하였다. 예측 모델의 여름철(JAS) 1일 예측 결과는 R2=0.996, RMSE=0.119℃, MAPE=0.352% 이고, 겨울철(JFM) 1일 예측 결과는 R2=0.999, RMSE=0.063℃, MAPE=0.646% 이었다. 예측한 해수면 온도를 이용하여 이상 수온 예측 정확도 평가를 F1 Score로 수행하였다(여름철(2021/08/05) 고수온 예측 결과 F1 Score=0.98, 겨울철(2021/02/19) 저수온 예측 결과 F1 Score=1.0). 예측 기간이 증가하면서 예측 모델이 해수면 온도를 과소추정하는 경향을 보여주었고, 이로 인해 이상 수온 예측 정확도 또한 낮아졌다. 따라서, 향후 예측 모델의 과소추정 원인을 분석하고 예측 정확도 향상을 위한 연구가 필요할 것으로 판단된다.

고분자용액의 수면전개 특성 및 박막구조 (Characteristics of Spreading of Polymer Solution and Morphology of Ultrathin Membrane Prepared by Water-Casting Method)

  • 남석태;최성부;최호상;김병식
    • 멤브레인
    • /
    • 제1권1호
    • /
    • pp.55-64
    • /
    • 1991
  • 본 연구는 수면전개법으로 고분자 박막을 제조하기 위한 연구로서 PVC 및 CA의 고분자용액의 수면전개 거동과 생성된 박막의 구조특성을 검토하였다. 고분자용액의 수면전개성은 고분자용액의 용매선정에 따른 표면장력, 점도의 변화와 고분자의 농도변화에 따라 영향을 받았다. 또한 수면온도가 증가함에 따라 전개성은 저하되었다. 수면전개 박막의 구조는 고분자농도가 증가할수록 치밀하여 졌으며, 막의 응집상태는 공기면측과 수면측이 다르게 나타나 공기면측의 상태가 다소 치밀하였다. 또한 수면의 온도가 증가할수록 막의 구조는 더 치밀함을 보였다. 한편 3 wt.%의 CA용액으로부터 $0.1{\mu}$의 두께를 갖는 박막을 얻었다.

  • PDF