• Title/Summary/Keyword: Surface Vessel

Search Result 507, Processing Time 0.026 seconds

Effect of Flaw Characterization on the Structural Integrity Evaluation Under Pressurized Thermal Shock (가압열충격 사고시 결함 이상화 방법이 구조물 건전성 평가에 미치는 영향)

  • Kim, Jin-Su;Choe, Jae-Bung;Kim, Yeong-Jin;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.275-282
    • /
    • 2001
  • The reactor pressure vessel is usually cladded with stainless steel to prevent corrosion and radiation embrittlement. Number of subclad cracks may be found during an in-service-inspection due to the presence of cladding. It is specified, in ASME Sec. XI, that a subclad crack is characterized as a surface crack when the thickness of the clad is less than 40% of the crack depth. This condition is provided to keep the crack integrity evaluation conservative. In order to refine the fracture assessment procedures for such subclad cracks under a pressurized thermal shock condition, three dimensional finite element analyses are applied for various subclad cracks existing under cladding. A total of 36 crack geometries are analyzed, and the results are compared with those for surface cracks. The resulting stress intensity factors for subclad cracks are 6 to 44% less than those for surface cracks. It is proven that the flaw characterization condition as specified in ASME Sec. XI can be overly conservative for some subclad cracks.

Failure Analysis of Condenser Fin Tubes of Package Type Air Conditioner for Navy Vessel (함정용 패키지 에어콘 응축기 핀튜브(Cu-Ni 70/30) 누설파괴 원인 분석)

  • Park, Hyoung Hun;Hwang, Yang Jin;Lee, Kyu Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.5
    • /
    • pp.439-446
    • /
    • 2016
  • In 2015, a fin tube (Cu-Ni 70/30 alloy) of package type heat exchanger for navy vessel was perforated through the wall which led to refrigerant leakage. This failure occurred after only one year since its installation. In this study, cause of the failure was determined based on available documents, metallographic studies and computational fluid dynamics simulation conducted on this fin tube. The results showed that dimensional gap between inserted plastic tube and inside wall of fin tube is the cause of the swirling turbulent stream of sea water. As a result of combination of swirling turbulence and continuing collision of hard solid particles in sea water, erosion corrosion has begun at the end of inserted plastic tube area. Crevice corrosion followed later in the crevice between the outer wall of plastic tube and inner wall of fin tube. It was found that other remaining tubes also showed the same corrosion phenomena. Thorough inspection and prompt replacement will have to be accomplished for the fin tubes of the same model heat exchanger.

Study on the Speed-Power Characteristics Through a Speed Trial of a Large Container Vessel During a Commercial Voyage Part I (상업 운항 중인 대형 컨테이너선의 항차 중 속력 시운전을 통한 선속-동력 특성 연구 Part I)

  • Kim, Ho;Lee, Joon-Hyoung;Jang, Jin-Ho;Ahn, Hae-Seong;Kang, Dae-Youl;Byeon, Sang-Su
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.366-374
    • /
    • 2021
  • This paper presents the analysis of the speed-power performance in the real sea using a large container vessel data provided as a test bed from a shipping company. To perform a speed trial of the vessel during a commercial voyage, the on-board measuring device and various operation data acquisition systems were mounted on the vessel for long-term performance monitoring and the voyage operated under the container loading condition close to the design draft was adopted. The content of this paper consists of Part I and Part II. Part I, such as this paper, contains the speed trial method and analysis results of the operating vessel. Part II contains the analysis of the speed-power characteristics change over time and before and after hull cleaning using operation data measured from the voyage operated under a condition similar to the speed trial.

A Study on Fatigue Crack Growth Characterization Of Surface Crack In Pressure Vessel Materials (압력용기 소재에서의 표면균열의 피로균열 성장특성에 관한 연구)

  • 허용학;이주진;한지원;김종집;문한규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.96-102
    • /
    • 1990
  • Cracks found in pressure vessels have been reported to be mostly semi-elliptic surface cracks. The fatigue crack growth behaviour of the surface cracks on pressure vessel materials, SPV 50Q and API 5A-K55, was studied with the consideration of the crack opening character. To determine the crack opening loads for the surface cracks, the displacement/strain were measured at three positions; the center and the side of the surface crack, the back face of the specimen using CMOD gauge and strain gauges. The experimental results showed that the crack opening load levels measured at the side of the surface crack were generally a little higher than those measured at the back face. As for the crack growth rates at the different parts of the surface crack, the experiments also showed that, if .DELTA.K$_{eff}$ is used, the exponent n of the Paris' law obtained were the same for the rear and the side parts of the surface cracks.

The Study of Speed Performance as Implement of Underwater Cleaning (수중세척 전후 속도 성능 고찰)

  • Cho, Won-Ho;Bang, Young-Bae
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2009.09a
    • /
    • pp.35-39
    • /
    • 2009
  • The fouling around the surface of hull and propeller caused by marine organism and sea water occur in the vessel which is taken up mooring in a quay for a quite long time. Moreover, those are able to give rise to the loss of speed performance. The purpose of underwater cleaning is to improve the performance of vessel and customer satisfaction through management for fouling condition of propeller and hull. Therefore, systematic approach in connection with underwater cleaning is required so as to obtain the stable speed performance. As a result, we evaluate the effect of propeller polishing to speed performance from the case of 115K COT and 4,250 TEU Container Ship. In addition, we issue the importance of underwater cleaning through comparison of speed results depending on conditions of hull surface painted by silicon.

  • PDF

An experimental study on heat transfer of finned vertical cooling tube (휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究))

  • Song, H.J.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

Effect of the Pulsatile Flow on the Morphological Changes of the Endothelial Cells in Blood Vessel (맥동유동이 혈관내 내피세포의 형태변화에 미치는 영향)

  • Suh, Sang-Ho;Yoo, Sang-Sin;Cho, Min-Tae;Park, Chan-Young;Chang, Jun-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.531-534
    • /
    • 2000
  • The objective of this investigation is to find effects of the pulsatile flow on the morphological changes of the endothelial cell(E.C.) in blood vessel. The shear flow experiment system is used to get the morphological changes of the E.C. The shapes of E.C. are simulated by the cosine curves and computer simulation is used to calculate the pressure and shear stress fields on the E.C. The inlet boundary condition is given from the measured velocity data of femoral artery. The endothelial cells reduce their heights in the flow field so as to reduce the pressure and wall shear stress on the surface. As the exposed time increases, the shear stress and pressure on the E.C. are reduced under the pulsatile flow. The shear stresses on the cell surface show the minimum values during the deceleration phase.

  • PDF

The conservation for the cast iron of a storaged big vessel in Kyongpok Palace (주조철제 유물 보존처리-경복궁 드므 보존처리를 중심으로)

  • Moon, Whan-Suk
    • 보존과학연구
    • /
    • s.19
    • /
    • pp.179-191
    • /
    • 1998
  • The Dumu of casted iron objects which is the big vessel for the prevention of fire to wood building is conserved in Kyongpok Palace(Dumu sizes:diameter 97cm, height 42cm, thickness 2cm, weight 250kg). The treated objects which some parts were lost, were not corroded, but cracted and broken by an external power, and strongly attached an cement layer on inside surface. First of all cement layer was mechanically removed by pneumatic needle scaler, welded to electric method for broken and cracked pieces, and then the lost sections were restored to use a epoxy resin and glass fiber. In order to prevent a damage during the handling, the restoration section of the inside surface was treated different colour in comparison with original part.

  • PDF

Acoustic Emission Testing of Cylindrical Reactor Pressure Vessel during Hydrotests (수압시험중(水壓試驗中)의 원주형(圓柱型) 압력용기(壓力容器)에 대(對)한 AE검사(檢査))

  • Chang, Hong-Keun;Lee, Joo-Suk;Chung, Sung-Mok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.1
    • /
    • pp.5-10
    • /
    • 1984
  • One of the cylindrical reactor vessels in petrochemical plants was examined by acoustic emission method. The vessel was quiet in view of A.E. activity throughout the pressure range $12-44kg.f/cm^{2}.G$. Above the pressure of $44kg.f/cm^2$, some events were appeared lower than 30 counts. In order to verify the events, other Nondestructive testing methods were performed and a surface crack, 10mm in length and 0.8mm in depth, was found on the outside surface of circumferential weld.

  • PDF

A Study on the Insulation Design Parameters of the Reactor in the Korean Standard Nuclear Power Plant (한국표준원전 원자로용기의 단열 설계에 관한 연구)

  • 김석범;백세진;임덕재;최해윤;이상섭;박종호
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.285-292
    • /
    • 1999
  • The design parameter of the reactor vessel insulation for the Korea Standard Power Plant has been studied numerically. The heat loss from the reactor vessel through the insulation is analysed by using the computational fluid dynamics code, FLUENT. Parametric study has been performed on the air gap width between the reactor vessel wall and the inner surface of the insulation, and on the insulation thickness. Also evaluated is the performance degradation due to the chimney effect caused by gaps between the panels during the installation of the insulation system. From the analysis results, the optimal air gap width and the optimal insulation thickness are obtained.

  • PDF