• 제목/요약/키워드: Surface Model

Search Result 10,519, Processing Time 0.042 seconds

The Effects of Mechanical Strain on Bone Cell Proliferation and Recruitment Induced by Osteocytes

  • Ko, Seong-Hee;Lee, Jiy-Hye;Kim, So-Hee
    • International Journal of Oral Biology
    • /
    • v.33 no.4
    • /
    • pp.179-186
    • /
    • 2008
  • Several lines of evidence suggest that osteocytes play a critical role in bone remodeling. Both healthy and apoptotic osteocytes can send signals to other bone surface cells such as osteoblasts, osteoclasts, osteoclast precursors, and bone lining cells through canalicular networks. Osteocytes responding to mechanical strain may also send signals to other cells. To determine the role for osteocytes an mechanical strain in bone remodeling, we examined the effects of fluid flow shear stress on osteoclast precursor cell and osteoblast proliferation and recruitment induced by osteocytes. In addition, the effects of fluid flow shear stress on osteocyte M-CSF, RANKL, and OPG mRNA expression were also examined. MLO-Y4 cells were used as an in vitro model for osteocytes, RAW 264.7 cells and MOCP-5 cells as osteoclast precursors, and 2T3 cells as osteoblasts. MLO-Y4 cells conditioned medium (Y4-CM) was collected after 24h culture. For fluid flow experiments, MLO-Y4 cells were exposed to 2h of pulsatile fluid flow (PFF) at 2, 4, 8, $16{\pm}0.6\;dynes/cm^2$ using the Flexcell $Streamer^{TM}$ system. For proliferation assays, MOCP-5, RAW 264.7, and 2T3 cells were cultured with control media or 10-100% Y4 CM. Cells were cultured for 3d, and then cells were counted. RAW 264.7 and 2T3 cell migration was assayed using transwells with control media or 10-100% Y4-CM. M-CSF, RANKL and OPG in MLO-Y4 mRNA expression was determined by semiquantitative RT-PCR. Y4-CM increased osteoclast precursor proliferation and migration, but decreased 2T3 cell proliferation and migration. CM from MLO-Y4 cells exposed to PFF caused decreased RAW 267.4 cell proliferation and migration and 2T3 migration compared to control Y4-CM. However, Y4-CM from cells exposed to PFF had no effect on 2T3 osteoblastic cell proliferation. PFF decreased RNAKL mRNA and increased OPG mRNA in MLO-Y4 cells compared to control(without PFF). PFF had no effect on M-CSF mRNA expression in MLO-Y4 cells. These results suggest that osteocytes can regulate bone remodeling by communication with osteoclast precursors and osteoblasts and that osteocytes can communicate mechanical signals to other cells.

The Effect of Deposition Parameters on the Morphology of KLN Thin Films (증착 조건이 KLN 박막의 형상에 미치는 영향)

  • Park, Seong-Geun;Jeon, Byeong-Eok;Kim, Jin-Su;Kim, Ji-Hyeon;Choe, Byeong-Jin;Nam, Gi-Hong;Ryu, Gi-Hong;Kim, Gi-Wan
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • The growth characteristics of 4-fold grain which was appeared in KLN deposition on $Pt/Ti/SiO_2/Si(100)$ substrate was studied by varying process variables. Substrate temperature, sputtering pressure, rf power were selected as process variables, and experiment was carried out near optimum fabrication condition. When using K and Li enriched target, the optimum fabrication conditions were substrate temperature of $600^{\circ}C$, sputtering pressure of 150mTorr, rf power of 100 W and its surface morphology is sensitively varied by small deposition condition changes. KLN is composed of elements which have large difference of boiling point. And it is difficult to fabricate thin film at high temperature and high vacuum deposition condition. Furthermore the phenomenon during deposition process can not be explained by using Thorton's model which explains the relation between thin film structure and melting point of thin film materials. These phenomenon can be explained using boiling point of elements which consist of thin film material.

  • PDF

Development of Abrasive Film Polishing System for Cover-Glass Edge using Multi-Body Dynamics Analysis (다물체 동역학 해석을 이용한 커버글라스 Edge 연마용 Abrasive Film Polishing 시스템 개발)

  • Ha, Seok-Jae;Cho, Yong-Gyu;Kim, Byung-Chan;Kang, Dong-Seong;Cho, Myeong-Woo;Lee, Woo-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7071-7077
    • /
    • 2015
  • In recently, the demand of cover-glass is increased because smart phone, tablet pc, and electrical device has become widely used. The display of mobile device is enlarged, so it is necessary to have a high strength against the external force such as contact or falling. In fabrication process of cover-glass, a grinding process is very important process to obtain high strength of glass. Conventional grinding process using a grinding wheel is caused such as a scratch, chipping, notch, and micro-crack on a surface. In this paper, polishing system using a abrasive film was developed for a grinding of mobile cover-glass. To evaluate structural stability of the designed system, finite element model of the polishing system is generated, and multi-body dynamic analysis of abrasive film polishing machine is proposed. As a result of the analysis, stress and displacement analysis of abrasive film polishing system are performed, and using laser displacement sensor, structural stability of abrasive film polishing system is confirmed by measuring displacement.

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF

Physical properties and intracellular uptake of polyethyleneglycol-incorporated cationic liposomes (폴리에틸렌글리콜이 도입된 양이온성 리포솜의 물리적 특성 및 세포이입효과)

  • Jung, Soon-Hwa;Jung, Suk-Hyun;Kim, Sung-Kyu;Seong, Ha-Soo;Cho, Sun-Hang;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.15-21
    • /
    • 2008
  • Liposomes as one of the efficient drug carriers have some shortcomings such as their short circulation time, fast clearance from human body by reticuloendothelial system (RES) and limited intracellular uptake to target cell. In this study, polyethylenglycol (PEG)-incorporated cationic liposomes were prepared by ionic complexation of positively charged liposomes with carboxylated polyethyleneglycol (mPEG-COOH). The cationic liposomes had approximately $98.6{\pm}1.0nm$ of mean particle diameter and $42.8{\pm}0.8mV$ of zeta potential value. The PEG-incorporated cationic liposomes had $110.1{\pm}1.2nm$ of mean particle diameter with an increase of about 10 nm compared to the cationic liposomes. Zeta potential value of them was $12.9{\pm}0.6mV$ indicating 30mV decrease of cationic charge compared to the cationic liposomes. The amount of PEG which was incorporated onto the cationic liposomes was assayed by using picrate assay method and the incorporation efficiency was $58.4{\pm}1.1%$. Loading efficiency of model drug, doxorubicin, into cationic liposomes or PEG-incorporated cationic liposomes was about $96.0{\pm}0.7%$. Results of intracellular uptake which were evaluated by flow cytometry analysis of doxorubicin loaded liposomes showed that intracellular uptake of PEG-incorporated cationic liposomes was higher than the cationic liposomes or DSPE-mPEG liposomes. In addition, cytotoxicity of PEG-incorporated cationic liposomes was comparable to cationic liposomes. Consequently, the PEG-incorporated cationic liposomes of which surface was incorporated with PEG by ionic complex may be applicable as anticancer drug carriers that can increase therapeutic efficacy.

Investigation of Hydraulic Flow Properties around the Mouths of Deep Intake and Discharge Structures at Nuclear Power Plant by Numerical Model (수치모의를 통한 원자력 발전소 심층 취·배수 구조물 유·출입구 주변에서의 수리학적 흐름특성 고찰)

  • Lee, Sang Hwa;Yi, Sung Myeon;Park, Byong Jun;Lee, Han Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.123-130
    • /
    • 2012
  • A cooling system is indispensable for the fossil and nuclear power plants which produce electricity by rotating the turbines with hot steam. A cycle of the typical cooling system includes pumping of seawater at the intake pump house, exchange of heat at the condenser, and discharge of hot water to the sea. The cooling type of the nuclear power plants in Korea recently evolves from the conventional surface intake/discharge systems to the submerged intake/discharge systems that minimize effectively an intake temperature rise of the existing plants and that are beneficial to the marine environment by reducing the high temperature region with an intensive dilution due to a high velocity jet and density differential at the mixing zone. It is highly anticipated that the future nuclear power plants in Korea will accommodate the submerged cooling system in credit of supplying the lower temperature water in the summer season. This study investigates the approach flow patterns at the velocity caps and discharge flow patterns from diffusers using the 3-D computational fluid dynamics code of $FLOW-3D^{(R)}$. The approach flow test has been conducted at the velocity caps with and without a cap. The discharge flow from the diffuser was simulated for the single-port diffuser and multi-ports diffuser. The flow characteristics to the velocity cap with a cap demonstrate that fish entrainment can significantly be minimized on account of the low vertical flow component around the cap. The flow pattern around the diffuser is well agreed with the schematic diagram by Jirka and Harleman.

Discussion on Optimal Shape for Wave Power Converter Using Oscillating Water Column (진동수주형 파력발전구조물의 최적형상에 대한 검토)

  • Lee, Kwang-Ho;Park, Jung-Hyun;Baek, Dong-Jin;Cho, Sung;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.5
    • /
    • pp.345-357
    • /
    • 2011
  • Recently, as part of diversifying energy sources and earth environmental issues, technology development of new renewable energy using wave energy is actively promoted and commercialized around Europe and Japan etc. In particular, OWC(Oscillating Water Column) wave power generation system using air flow induced by vertical movement of the water surface by waves in an air-chamber within caisson is known as the most efficient wave energy absorption device and therefore, is one of the wave power generation apparatus the closest to commercialization. This study examines air flow velocity, which operates turbine(Wells turbine) directly in oscillating water column type wave power generation structure from two-and three-dimensional numerical experiments and discusses optimal shape of oscillating water column type wave power generation structure by estimating the maximum flow rate of air according to change in shape. The three-dimensional numerical wave flume was applied in interpretation for this study which is the model for the immiscible two-phase flow based on the Navier-Stokes Equation. From this, it turned out that size of optimal shape appears differently according to the incident wave period and air flow is maximized at the period where minimum reflection ratio occurs.

A STUDY ON THE ELASTIC DEFORMATION AND STRESS DISTRIBUTION OF THE MANDIBLE WITH OSSEOINTEGRATED IMPLANT PROSTHESES USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (골유착성 임플랜트 보철물 장착시 하악골의 탄성변형 및 응력분포에 관한 삼차원 유한요소법적 연구)

  • Kim, Yong-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.203-244
    • /
    • 1998
  • The human mandible is always under the condition of loading by the various forces extorted by the attached muscles. The loading is an important condition of the stomatognathic system. This condition is composed of the direction and amount of forces of the masticatory muscles, which are controlled by the neuromuscular system, and always influenced by the movement of both opening and closing. Mandible is a strong foundation for the teeth or various prostheses, nevetheless it is a elastic body which accompanies deformation by the external forces on it. The elastic properties of the mandible is influenced by the various procedures such as conventional restorative treatments, osseointegrated implant treatments, reconstructive surgical procedures and so forth. Among the treatments the osseointegrated implant has no periodontal ligaments, which exist around the natural teeth to allow physiologic mobility in the alveolar socket. And so around the osseointegrated implant, there is almost no damping effect during the transmission of occlusal stress and displacements. If the osseointegrated implants are connected by the superstructure for the stabilization and effective distribution of occlusal stresses, the elastic properties of mandible is restricted according to the extent of 'splinting' by the superstructure and implants. To investigate the change of elastic behaviour of the mandible which has osseointegrated implant prosthesis of various numbers of implant installment and span of superstructre, a three dimensional finite element model was developed and analyzed with conditions mentioned above. The conclusions are as follows : 1. The displacements are primarily developed at the area of muscle attachment and distributed all around the mandible according to the various properties of bone. 2. The segmentation in the superstructure has few influence on the distribution of stress and displacement. 3. In the load case of ICP, the concentration of tensional stress was observed at the anterior portion of the ramus($9.22E+6N/m^2$) and at the lingual portion of the symphysis menti($8.36E+6N/m^2$). 4. In the load case of INC, the concentration of tensional stress was observed at the anterior portion of the ramus($9.90E+6N/m^2$) and the concentration of tensional stress was observed at the lingual portion of the symphysis menti($2.38E+6N/m^2$)). 5. In the load case of UTCP, the relatively high concentration of tensional stress($3.66E+7N/m^2$) was observed at the internal surface of the condylar neck.

  • PDF

A STUDY FOR THE CHANGES OF THE MASTICATORY MUSCLES AND THE MANDIBULER MOVEMENT EFFECTED BY INTENTIONAL INCREASE OF ANTERIOR GUIDANCE ANGLE (전치 유도각의 인위적 증가에 의한 저작근과 하악 운동 양상의 변화에 대한 연구)

  • Lee, Yong-Sik;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.245-257
    • /
    • 1998
  • This study was performed to measure the changes of the mandibular movement and the masticatory muscular activities - anterior temporal and masseter muscle of both side - reflected by intentional increase of anterior guidance angie. For this study, 5 volunteers (3 males and 2 females with average age of 24.0) were selected. Each volunteer had Angle's classification I and did not have any missing tooth except third molar and any extensive restorations. Metallic guide plate was made at volunteer's working model fabricated by improved dental stone and cemented to the palatal surface of maxillary central incisor using resin cement(Panavia $21^{(R)}$) and then adjusted not to give any occlusal interferences at intercuspal position. The activity of masticatory muscles and the changes of mandibular movement were recorded by EMG and Sirognathograph in Biopak analysing system(Bioresearch Inc., Milwaukee, Wisconsin, USA). Measurement was done at before experiment, immediatley after placement, 1 week after placement, immediately after removal, and 1 week after removal. The results were as follows: 1. Moderate phonetic disturbance and mild headache were occured to 3 volunteers for 2 days after setting and 1 volunteer had positive reaction to percussion and slight midline diastema. But all of these clinical signs were diappeared 1 week after removal and the other volunteer did not have any special clinical sign. 2. In the EMG of the mandibular rest position, the mean value of anterior tempotal muscle was increased immediately after placement(p<0.01) and then decreased 1 week after placement(p<0.05) and increased 1 week after removal(p<0.05) but not recovered as before experiment. The mean value of masseter muscle was decreased during the experiment period. 3. In the EMG during mandibular protrusive movement, all muscular activity was decreased during the experiment period. Reduced activity was not recovered 1 week after removal(p<0.03). 4. During the habitual opening, anteroposterior movement of mandible was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not statistically significant(p>0.1). Vertical movement was not shown significant difference during the experiment period(p>0.1). Lateral movement was decreased immediately after placement(p<0.05) and then increased 1 week after placement but not recovered as before experiment. The opening and closing velocity of mandible was shown minor changes but not statistically significant. 5. During the habitual opening, anteroposterior movement of mandible was decreased 1 week after placement(p<0.05) and then increased immediately after removal and recovered 1 week after removal as before experiment. Vertical movement was not shown significant changes. Lateral displacement of mandible was increased continuously and recovered 1 week after removal. Opening velocity was temporarily increased immediately after removal but recovered and closing velocity was not shown significant changes. 6. During the right side chewing, anteroposterior movement of mandible was increased immediately after removal but recovered and vertical movement was not shown statistically significant results. Lateral displacement and velocity of mandible were not shown significant results. 7. During the left side chewing, the changes of mandibular movement pattern were not shown statistically significant results.

  • PDF

Effects of EBCT and Water Temperature on HAA Removal using BAC Process (BAC 공정에서 EBCT와 수온에 따른 HAA 제거 특성)

  • Son, Hee-Jong;Yoo, Soo-Jeon;Yoo, Pyung-Jong;Jung, Chul-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1255-1261
    • /
    • 2008
  • In this study, The effects of three different biological activated carbon (BAC) materials (each coal, coconut and wood based activated carbons), empty bed contact time (EBCT) and water temperature on the removal of haloacetic acid (HAA) 5 species in BAC filters were investigated. Experiments were conducted at three water temperatures (5, 10 and 20$^{\circ}C$) and four EBCTs (5, 10, 15 and 20 min). The results indicated that coal based BAC retained more attached bacterial biomass on the surface of the activated carbon than the other BAC, increasing EBCT or increasing water temperature increased the HAA 5 species removal in BAC columns. To achieve an HAA removal efficiency 50% or higher in a BAC filter, the authors suggest 10 min EBCT or longer for 5$^{\circ}C$ waters and 5 min EBCT for waters at 10$^{\circ}C$ or higher. The kinetic analysis suggested a first-order reaction model for HAA 5 species removal at various water temperatures (5, 10 and 20$^{\circ}C$). The pseudo-first-order reaction rate constants and half-lives were also calculated for HAA removal at 5, 10 and 20$^{\circ}C$. The pseudo-first-order reaction rate constants and half-lives were also calculated for HAA 5 species removal at 5$\sim$ 20$^{\circ}C$. The half-lives of HAA 5 species ranging from 0.75 to 18.58 min could be used to assist water utilities in designing and operating BAC filters for HAA removal.