• 제목/요약/키워드: Surface Impedance

검색결과 752건 처리시간 0.024초

무작위로 거친 표면에서의 후방복사 초음파 (Ultrasonic Backward Radiation on Randomly Rough Surface)

  • 권성덕
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.9-14
    • /
    • 2005
  • 표면 거칠기가 다른 유리시편에 대해 후방 복사된 초음파 세기의 입사각 의존성(프로파일)이 측정되었다. 후방복사 세기와 레일리(Rayleigh) 표면파 속도는 표면 거칠기에 비례하였고 이 경향은 각기 초음파의 산란규칙과 경화현상으로 설명되었다. 후방복사 프로파일의 면적 역시 표면 거칠기에 민감함을 보여 표면상태에 대한 새로운 비파괴적 평가 변수의 가능성을 보였다. 레일리 각 C-스캔 기법은 화상 명도의 반전과 높은 신호대 잡음비(S/N)를 보여주었다.

Transformation of PEO coatings from crater to cluster-based structure with increase in DC voltage and the role of ZrO2nanoparticles

  • Rehman, Zeeshan Ur;Shin, Seong Hun;Koo, Bon Heun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.111-111
    • /
    • 2016
  • Two step PEO ceramic coatings were formed on AZ91 magnesium alloy in $ZrO_2$ nanoparticles and $K_2ZrF_6$ based colloidal electrolyte solution for various voltages. Surface and layers tructure of the coatings was analyzed using SEM (ScanningElectronMicroscope). Structure analysis revealed that surface of the coating was transferred from individual pancake or craters-based structure to cluster-based structure with increasing the voltage of the secondary step process. Further, it was confirmed that the cluster zone was richin Zr-based complexes and formed due to high intensives parks. Increase in the Zr contents as discovered from the EDS analysis confirmed the rise in amorphous form of the Zr-based species, which justified the results of XRD where no increase in the intensity of Zr-based species was observed with increase in voltage. Potentiodynamic polarizariotion and impedance spectroscopy techniques were used to evaluate the corrosion performance of the coatings. The highest corrosion resistance was found for coatings prepared at 240V. The same specimen was found having highest and uniform vickers hardness ~1070.5 HV. The superior mechanical and electrochemical properties of the said coating can be attributed to the defect-less microstructure and the optimal role of $ZrO_2$ nanoparticles in the secondary PEO process at 240V.

  • PDF

Tribological and Corrosion Behavior of Multilayered $WC-Ti_{1-x}Al_xN$ Coatings Deposited by Cathodic Arc Deposition Process on High Speed Steel

  • S.H. Ahn;J.H. Yoo;Park, Y.S.;Kim, J.G.;Lee, H.Y.;J.G. Han
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 추계학술발표회 초록집
    • /
    • pp.31-32
    • /
    • 2001
  • Recently, many of the current development in surface modification engineering are focused on multilayered coatings. Multilayered coatings have the potential to improve the tribological and corrosion properties of tools and components. By using cathodic arc deposition, $WC-Ti_{1-x}Al_xN$ multilayers were deposited on steel substrates. Wear tests of four multiplayer coatings were performed using a ball-on-disc configuration with a linear sliding speed of 0.1m/s, 5N load. The tests were carried out at room temperature in airby employing AISI 52100 steel ball ($H_v=848N$) of 11mm in diameter. Electrochemical tests were performed using the potentiodynamic and electrochemical impedance spectroscopy (EIS) measurements. The surface morphology and topography of the wear scars of tribo-element and the corroded specimen have been determined by using scanning electron spectroscopy (SEM). Also, wear mechanism was determined by using SEM coupled with EDS. Results have showed an improved wear resistance and corrosion resistance of the $WC-Ti_{1-x}Al_xN$ coatings.

  • PDF

고규소 알루미늄 합금의 표면에 PEO 공정에 의하여 형성된 산화물 층의 부식 거동 (Corrosion behavior of oxide layer formed on surface of high silicon aluminum alloy by PEO process)

  • 박덕용
    • 한국표면공학회지
    • /
    • 제56권4호
    • /
    • pp.250-258
    • /
    • 2023
  • Ceramic oxide layer was formed on the surface of high silicon aluminum alloy by using PEO (plasma electrolytic oxidation) process. The microstructure of the oxide layer was analyzed using scanning electron microscopy (SEM) and x-ray diffraction patterns (XRD). The high silicon aluminum alloy prior to PEO process consists of Al, Si and Al2Cu phases in XRD analysis, whereas Al2Cu phase selectively disappeared after PEO treatment. Considerable decrease of relative intensity in most of peaks in XRD results of the high silicon aluminum alloy treated by PEO process was observed. It may be attributed to the formation of amorphous phases after PEO treatment. The corrosion behavior of the high silicon aluminum alloy treated by PEO process was investigated using electrochemical impedance spectroscopy (EIS) and other electrochemical techniques (i.e., open circuit potential and polarization curve). Electroanalytical studies indicated that the high silicon aluminum alloy treated by PEO process shows greater corrosion resistance than that untreated by PEO process.

전기화학 바이오센서의 전극물질로 응용을 위한 열분해 탄소의 제작 및 특성 연구 (Fabrication and Characterization of Pyrolyzed Carbon for Use as an Electrode Material in Electrochemical Biosensor)

  • 이정아;황성필;곽주현;박세일;이승섭;이광철
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.986-992
    • /
    • 2007
  • This paper presents the fabrication and characterization of carbon films pyrolyzed with various photoresists for bioMEMS applications. To verify the usefulness of pyrolyzed carbon films as an electrode material in an electrochemical biosensor developed by the authors, interactions between avidin and biotin on the pyrolyzed carbon film were studied via electrochemical impedance spectroscopy based on electrostatic interactions between avidin and negatively-charged ferricyanide. The pyrolyzed carbon films were characterized using a surface profiler, a precision semiconductor parameter analyzer, a nanoindentor, scanning electron microscopy, and atomic force microscopy. Amine conjugated biotin was immobilized on the electrode using EDC/NHS as crosslinkers after $O_2$ plasma treatment to enhance functional groups on the carbon electrode pyrolyzed at $1000^{\circ}C$ with AZ9260. The detection of avidin binding with different concentrations in a range of 0.75 nM to $7.5\;{\mu}M$ to the pyrolyzed carbon electrode modified with biotin was carried out by measuring the electrochemical impedance change. The results show that avidin binds to the biotin on the electrode not by non-specific interaction but by specific interaction, and that EIS successfully detects this binding event. Pyrolyzed carbon films are a promising material for miniaturization, integration, and low-cost fabrication in electrochemical biosensors.

주조용 Al합금의 내식성에 관한 전기화학적 평가 (An Electrochemical Evaluation on the Corrosion Resistance of a Al Alloy)

  • 윤대현;이명훈;김기준;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.495-501
    • /
    • 2005
  • Al is a active metal that owes its resistance to a thin, protective, barrier oxide surface layer, which is stable in air and neutral aqueous solution. Thus Al alloys are widely used in architectural trim. cold & hot-water storage vessels and piping. However Al and most of its alloy may corrode with some forms such as pitting corrosion, intergranular corrosion and galvanic corrosion in the case of exposure to various industrial and marine atmosphere. Therefore a correct evaluation of corrosion resistance for their Al and Al alloys may be more important in a economical point of view. In this study. a relative evaluation of corrosion resistance for three kinds of Al alloys such as ALDC2, ALDC3, and ALDC8 series was carried out with electrochemical method. There is a tendency that corrosion potential is shifted to positive or negative direction by alloying components regardless of corrosion resistance. Moreover the data of corrosion properties obtained from cathodic Polarization curve, cyclic voltammogram and AC. DC impedance respectively showed a good correspondence each other against the corrosion resistance but variation of corrosion potential. passivity current density of anodic polarization curve and corrosion current density by Tafel extrapolation and Stern-Geary method didn't correspond with not only each other but also considerably the data of corrosion properties discussed above. Therefore it is suggested that an optimum electrochemical evaluation for corrosion resistance of Al alloy is to calculate the diffusion limiting current density of cathodic polarization curve, impedance of AC or DC and polarization resistance of cyclic voltammogram.

"Dice와 fill" 방식을 이용한 1-3 압전복합재의 제조와 횡방향 단위 크기에 따른 압전특성 평가 (Fabrication of 1-3 Piezo-composites with a "Dice & Fill" Method and Characterization of Their Piezoelectric Properties as a Function of Lateral Spatial Scale)

  • 김영덕;김광일;정우철;김흥락;김동수
    • 비파괴검사학회지
    • /
    • 제22권4호
    • /
    • pp.354-360
    • /
    • 2002
  • NDT나 의료용 영장장치에 응용되는 압전복합재는 일반적인 세라믹이나 고분자 압전재료에 비하여 많은 장점을 가진다. 이들 응용분야에서는 전기기계결합계수가 높아야 하고 음향임피던스가 낮아야 한다. 그러나, 압전복합재의 횡방향 단위 크기가 조밀하지 못할 경우 횡방향으로 진행하는 판파에 의한 불필요한 진통이 표면에 발생하게 된다. 횡방향 단위 크기와 세라믹 체적비에 따른 압전 특성을 조사하기 위하여 PMN-PZT 세라믹과 Epofix 에폭시로 에폭시의 폭의 달리하면서 1-3형 압전복합채를 제작하였다. 제작된 1-3형 압전복합재의 두께방향 진동모드의 전기기계결합계 수, 음향임피던스는 각각 $0.36{\sim}0.64,\;9.8{\sim}22.7MRayl$ MRayl로 나타났으며, 횡방향 단위크기가 줄어들수록 횡방향 모드 공진 주파수가 증가하였다.

Corrosion Behavior of High Pressure Die Cast Al-Ni and Al-Ni-Ca Alloys in 3.5% NaCl Solution

  • Arthanari, Srinivasan;Jang, Jae Cheol;Shin, Kwang Seon
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.100-108
    • /
    • 2017
  • In this investigation corrosion behavior of newly developed high-pressure die cast Al-Ni (N15) and Al-Ni-Ca (NX1503) alloys was studied in 3.5% NaCl solution. The electrochemical corrosion behavior was evaluated using open circuit potential (OCP) measurement, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) techniques. Potentiodynamic polarization results validated that NX1503 alloy exhibited lower corrosion current density ($i_{corr}$) value ($5.969{\mu}A/cm^2$) compared to N15 ($7.387{\mu}A/cm^2$). EIS-Bode plots revealed a higher impedance (${\mid}Z{\mid}$) value and maximum phase angle value for NX1503 than N15 alloy. Equivalent circuit curve fitting analysis revealed that surface layer ($R_1$) and charge transfer resistance ($R_{ct}$) values of NX1503 alloy was higher compared to N15 alloy. Immersion corrosion studies were also conducted for alloys using fishing line specimen arrangement to simultaneously measure corrosion rates from weight loss ($P_W$) and hydrogen volume ($P_H$) after 72 hours and NX1503 alloy had lower corrosion rate compared to N15 alloy. The addition of Ca to N15 alloy significantly reduced the Al3Ni intermetallic phase and further grain refinement may be attributed for reduction in the corrosion rate.

IDENTIFICATION OF TWO-DIMENSIONAL VOID PROFILE IN A LARGE SLAB GEOMETRY USING AN IMPEDANCE MEASUREMENT METHOD

  • Euh, D.J.;Kim, S.;Kim, B.D.;Park, W.M.;Kim, K.D.;Bae, J.H.;Lee, J.Y.;Yun, B.J.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.613-624
    • /
    • 2013
  • Multi-dimensional two-phase phenomena occur in many industrial applications, particularly in a nuclear reactor during steady operation or a transient period. Appropriate modeling of complicated behavior induced by a multi-dimensional flow is important for the reactor safety analysis results. SPACE, a safety analysis code for thermal hydraulic systems which is currently being developed, was designed to have the capacity of multi-dimensional two-phase thermo-dynamic phenomena induced in the various phases of a nuclear system. To validate the performance of SPACE, a two-dimensional two-phase flow test was performed with slab geometry of the test section having a scale of $1.43m{\times}1.43m{\times}0.11m$. The test section has three inlet and three outlet nozzles on the bottom and top gap walls, respectively, and two outlet nozzles installed directly on the surface of the slab. Various kinds of two-dimensional air/water flows were simulated by selecting combinations of the inlet and outlet nozzles. In this study, two-dimensional two-phase void fraction profiles were quantified by measuring the local gap impedance at 225 points. The flow conditions cover various flow regimes by controlling the flow rate at the inlet boundary. For each selected inlet and outlet nozzle combination, the water flow rate ranged from 2 to 20 kg/s, and the air flow rate ranged from 2.0 to 20 g/s, which corresponds to 0.4 to 4 m/s and 0.2 to 2.3 m/s of the superficial liquid and gas velocities based on the inlet port area, respectively.

타일형 프로젝터를 이용한 저주파 능동 반향음 감소 기법 (Low-Frequency Active Echo Reduction Using a Tile Projector)

  • 이재완;우상범;장하다;이근상;김완구;강휘석;엄원석;박영철;윤석왕;서영수
    • 한국음향학회지
    • /
    • 제33권6호
    • /
    • pp.366-374
    • /
    • 2014
  • 저주파 능동 소나를 이용한 잠수함 탐지 기술이 개발됨에 따라, 기존의 수동 무반향 타일을 대치할 새로운 잠수함 스텔스 기술이 요구되는 추세이다. 본 연구에서는 선체 표면과 같은 대면적에 적용 가능한 타일형 프로젝터를 이용하여 능동 임피던스 정합을 구현함으로써 저주파 반향음 감소를 도모하는 기법을 제안한다. 먼저 능동 임피던스 정합 기법의 기술적 타당성을 확인하기 위하여 유한요소 모델을 이용한 저주파 반향음 감소 시뮬레이션을 수행하였다. 이를 바탕으로 타일형 프로젝터를 설계 및 제작하여 음향수조에서 저주파 반향음 감소 실험을 수행하였다.