• 제목/요약/키워드: Surface Imaging

검색결과 1,120건 처리시간 0.026초

Optimized TOF-PET detector using scintillation crystal array for brain imaging

  • Leem, Hyuntae;Choi, Yong;Jung, Jiwoong;Park, Kuntai;Kim, Yeonkyeong;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2592-2598
    • /
    • 2022
  • Research groups in the field of PET instrumentation are studying time-of-flight(TOF) technology to improve the signal-to-noise ratio of PET images. Scintillation light transport and collection plays an important role in improving the coincidence resolving time(CRT) of PET detector based on a pixelated crystal array. Four crystal arrays were designed by the different optical reflection configuration such as external reflectors and surface treatment on the CRT and compared with the light output, energy resolution and CRT. The design proposed in the study was composed of 8 × 8 LYSO crystal array consisted of 3 × 3 × 15 mm3 pixels. The entrance side was roughened while the other five surfaces were polished. Four sides of all crystal pixels were wrapped with ESR-film, and the entrance surface was covered by Teflon-tape. The design provided an excellent timing resolution of 210 ps and improved the CRT by 16% compared to the conventional method using a polishing treatment and ESR-film. This study provided a method for improving the light output and CRT of a pixelated scintillation crystal-based brain TOF PET detector. The proposed configuration might be an attractive detector design for TOF brain PET requiring fast timing performance with high cost-effectiveness.

쑥뜸과 1064 nm 파장의 근적외선 레이저로 가열된 아가젤 조직 팬텀 심부의 온도분포 가시화 (Visualization of Temperature Distribution Deep Inside the Agar Gel Tissue Phantom Heated Using Moxibustion and 1064 nm Infrared Laser)

  • 조지용;김중경
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.54-59
    • /
    • 2010
  • A laser moxibustion therapy device having effect similar to that of traditional moxibustion is being developed using 1064 nm infrared laser. The therapy device allows direct interaction of laser light with the tissue rendering temperature distribution both on the skin surface and deep under the skin. We made a device that could measure temperature of deep under the surface of agar gel tissue phantom using thermocouples. A thermal imaging camera was used to verify results from the temperature measurement device. We compared the characteristics of heat transfer inside the tissue phantom during moxibustion and laser irradiation. The temperature distribution measured by thermocouples was found to be similar to that of distribution given by thermal imaging camera.

Three Dimensional Volume Reconstruction of Polyhedral Objects Using X-ray Stereo Images

  • Roh, Young-Jun;Kim, Byung-Man;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.28.2-28
    • /
    • 2001
  • Three dimensional shape measurement techniques are widely needed in industries for product quality monitoring and control. X-ray imaging method is a promising technology to achieve three-dimensional Information, both the surface and inner structure of an object, since it can overcome the limitations of conventional visual or optical methods such as an occlusion problem or surface reflection properties. In this paper, we propose three dimensional volume reconstruction method based on x-ray stereo imaging technology. Here, the stereo images of an object from two different views are taken by changing the object pose rather than moving imaging plane as in conventional stereo vision method. We propose a series of image processing techniques to extract the features efficiently from x-ray images, where the occluded features in case of normal camera vision could be found ...

  • PDF

나노초 레이져를 이용한 광-초음파 이미지 결상법 (In vivo functional photoacoustic imaging)

  • Oh, Jung-Taek;Li, Meng-Lin;Song, Kwang-Hyun;Xie, Xueyi;Stoica, George;Wang, Lihong V.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2006년도 동계학술발표회 논문집
    • /
    • pp.359-360
    • /
    • 2006
  • Functional photoacoustic tomography is a new non-invasive imaging modality, and it is emerging as a very practical method for imaging biological tissue structures by means of laser-induced ultrasound. Structures with high optical absorption, such as blood vessels, can be imaged with the spatial resolution of ultrasound, which is not limited by the strong light scattering in biological tissues. By varying wavelengths of the laser light and acquiring photoacoustic images, optical absorption spectrum of each image pixel is found. Since the biochemical constituents of tissues determine the spectrum, useful functional information like oxygen saturation ($SO_2$) and total haemoglobin concentration (HbT) can be extracted. In this study, as a proof-of-principle experiment, hypoxic brain tumor vasculature and traumatic brain injury (TBI) of small animal brain are imaged with functional photoacoustic tomography. High resolution brain vasculature images of oxygen saturation and total hemoglobin concentration are provided to visualize hypoxic tumor vasculature, and hemorrhage on the cortex surface by the TBI.

  • PDF

Usefulness of Narrow-Band Imaging in Endoscopic Submucosal Dissection of the Stomach

  • Kim, Jung-Wook
    • Clinical Endoscopy
    • /
    • 제51권6호
    • /
    • pp.527-533
    • /
    • 2018
  • There have been many advances in endoscopic imaging technologies. Magnifying endoscopy with narrow-band imaging is an innovative optical technology that enables the precise discrimination of structural changes on the mucosal surface. Several studies have demonstrated its usefulness and superiority for tumor detection and differential diagnosis in the stomach as compared with conventional endoscopy. Furthermore, magnifying endoscopy with narrow-band imaging has the potential to predict the invasion depth and tumor margins during gastric endoscopic submucosal dissection. Classifications of the findings of magnifying endoscopy with narrow-band imaging based on microvascular and pit patterns have been proposed and have shown excellent correlations with invasion depth confirmed by microscopy. In terms of tumor margin prediction, magnifying endoscopy with narrow-band imaging offers superior delineation of gastric tumor margins compared with traditional chromoendoscopy with indigo carmine. The limitations of narrow-band imaging, such as the need for considerable training, long procedure time, and lack of studies about its usefulness in undifferentiated cancer, should be resolved to confirm its value as a complementary method to endoscopic submucosal dissection. However, the role of magnifying endoscopy with narrow-band imaging is expected to increase steadily with the increasing use of endoscopic submucosal dissection for the treatment of gastric tumors.

Teliospore mucilage of Puccinia miscanthi revealed through the axial imaging of secondary electrons

  • Ki Woo Kim
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.15.1-15.2
    • /
    • 2021
  • Puccinia miscanthi teliospores were observed on the leaf surface of Miscanthus sinensis using a field emission scanning electron microscope. Details of teliospore mucilage could be visualized through the axial imaging of secondary electrons for a better understanding of pathogen behavior in rust diseases.

The phase angle dependences of Reflectance on Asteroid (25143) Itokawa from the Hayabusa Spacecraft Multi-band Imaging Camera(AMICA)

  • Lee, Mingyeong;Ishiguro, Masateru
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.61.3-62
    • /
    • 2015
  • Remote-sensing observation is one of the observation methods that provide valuable information, such as composition and surface physical conditions of solar system objects. The Hayabusa spacecraft succeeded in the first sample returning from a near-Earth asteroid, (25143) Itokawa. It has established a ground truth technique to connect between ordinary chondrite meteorites and S-type asteroids. One of the scientific observation instruments that Hayabusa carried, Asteroid Multi-band Imaging Camera(AMICA) has seven optical-near infrared filters (ul, b, v, w, x, p, and zs), taking more than 1400 images of Itokawa during the rendezvous phase. The reflectance of planetary body can provide valuable information of the surface properties, such as the optical aspect of asteroid surface at near zero phase angle (i.e. Sun-asteroid-observer's angle is nearly zero), light scattering on the surface, and surface roughness. However, only little information of the phase angle dependences of the reflectance of the asteroid is known so far. In this study, we investigated the phase angle dependences of Itokawa's surface to understand the surface properties in the solar phase angle of $0^{\circ}-40^{\circ}$ using AMICA images. About 700 images at the Hayabusa rendezvous phase were used for this study. In addition, we compared our result with those of several photometry models, Minnaert model, Lommel-Seeliger model, and Hapke model. At this conference, we focus on the AMICA's v-band data to compare with previous ground-based observation researches.

  • PDF

Preparation and Characterization of Surface Energy of BPDA-BAPP Polyimide

  • Kim, Kyung-Hoe;Kim, Yong-Gwon;Kwon, Young-Hwan
    • Macromolecular Research
    • /
    • 제17권6호
    • /
    • pp.388-396
    • /
    • 2009
  • The surface properties (water sorption and repellency, adhesion) are closely related to the surface tension of polymer solids. The critical surface tension (${\gamma}_c$) and surface tension (${\gamma}_s$) of a polymer solid were estimated by the contact angle method by our quantitative imaging system. BPDA (3,3',4,4'-biphenyl tetracarboxylic dianhydride)-BAPP (1,3-Bis(4-aminophenoxy) propane) polyimide was successfully synthesized. The ${\gamma}_c$ values were analyzed by a Zisman plot, a Young-$Dupr\acute{e}$-Good-Girifalco plot, and a log ($1+cos{\theta}$) vs log ${\gamma}_L$ plot. The ${\gamma}_s$ value of BPDA-BAPE polyimide was evaluated using the geometric mean equation and our multiple regression analysis. The calculated values of ${{\gamma}_s^d$ (a dispersion component), ${{\gamma}_s^p$ (a polar component), ${{\gamma}_s^h$ (a hydrogen bonding component), and ${\gamma}_s$ were 30.79, 9.32, 0.20, and 40.31 $mN{\cdot}m^{-1}$, respectively. The ${\gamma}_s$ of BPDA-BAPP polyimide containing both a methylene group and an ether group was larger than that of the polyimide containing only a methylene group.

7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화 (Transmit Receive RF Resonator Optimization at 7 T MRI System)

  • ;유형석
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1727-1730
    • /
    • 2016
  • Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.

Immunosensor for Detection of Escherichia coli O157:H7 Using Imaging Ellipsometry

  • Bae Young-Min;Park Kwang-Won;Oh Byung-Keun;Choi Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권8호
    • /
    • pp.1169-1173
    • /
    • 2006
  • Imaging ellipsometry (IE) for detection of binding of Escherichia coli O157:H7 (E. coli O157:H7) to an immunosensor is reported. A protein G layer, chemically bound to a self-assembled layer of 11-mercaptoundecanoic acid (11-MUA), was adopted for immobilization of monoclonal antibody against E. coli O157:H7 (Mab). The immobilization of antibody was investigated using surface plasmon resonance. To fabricate antibody spots on a gold surface, protein G solution was spotted onto the gold surface modified with an 11-MUA layer, followed by immobilizing Mab on the protein G spot. Ellipsometric images of the protein G spot, the Mab spot, and Mab spots with binding of E. coli O157:H7 in various concentrations were acquired using the IE system. The change of mean optical intensity of the Mab spots in the ellipsometric images indicated that the lowest detection limit was $10^3$CFU/ml for E. coli O157:H7. Thus, IE can be applied to an immunosensor for detection of E. coli O157:H7 as a detection method with the advantages of allowing label-free detection, high sensitivity, and operational simplicity.