• 제목/요약/키워드: Surface Imaging

검색결과 1,125건 처리시간 0.026초

Optomechanical Design of a Compact Imaging Spectrometer for a Microsatellite STSAT3

  • Lee, Jun-Ho;Lee, Chi-Weon;Kim, Yong-Min;Kim, Jae-Wook
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.193-200
    • /
    • 2009
  • A compact imaging spectrometer (COMIS) is currently under development for use in the STSAT3 microsatellite. COMIS images the Earth's surface and atmosphere with ground sampling distances of ${\sim}30m$ in the $18{\sim}62$ spectral bands ($4.0{\sim}1.05{\mu}m$) for the nadir looking at an altitude of 700 km. COMIS has an imaging telescope and an imaging spectrometer box into which three electronics PCBs are embedded. These are designed into a single assembly with dimensions of 35(L) $\times$ 20(W) $\times$ 12(H) $cm^3$ and a mass of 4.3 kg. Optomechanical design efforts are focused on manufacturing ease, alignment, assembly, testing and improved robustness in space environments. Finite element analysis demonstrates that COMIS will survive in launch and space environments and perform the system modulation transfer function (MTF) in excess of 0.29 at the Nyquist frequency of the CCD detector (38.5 lines-per-mm).

Optical Biopsy of Peripheral Nerve Using Confocal Laser Endomicroscopy: A New Tool for Nerve Surgeons?

  • Crowe, Christopher S;Liao, Joseph C;Curtin, Catherine M
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.626-629
    • /
    • 2015
  • Peripheral nerve injuries remain a challenge for reconstructive surgeons with many patients obtaining suboptimal results. Understanding the level of injury is imperative for successful repair. Current methods for distinguishing healthy from damaged nerve are time consuming and possess limited efficacy. Confocal laser endomicroscopy (CLE) is an emerging optical biopsy technology that enables dynamic, high resolution, sub-surface imaging of live tissue. Porcine sciatic nerve was either left undamaged or briefly clamped to simulate injury. Diluted fluorescein was applied topically to the nerve. CLE imaging was performed by direct contact of the probe with nerve tissue. Images representative of both damaged and undamaged nerve fibers were collected and compared to routine H&E histology. Optical biopsy of undamaged nerve revealed bands of longitudinal nerve fibers, distinct from surrounding adipose and connective tissue. When damaged, these bands appear truncated and terminate in blebs of opacity. H&E staining revealed similar features in damaged nerve fibers. These results prompt development of a protocol for imaging peripheral nerves intraoperatively. To this end, improving surgeons' ability to understand the level of injury through real-time imaging will allow for faster and more informed operative decisions than the current standard permits.

콘크리트 구조물의 결함발견을 위한 3차원 초단파 영상처리기법의 개발 (3D Microwave Imaging Technology for Damage Detection of Concrete Structures)

  • 김유진;김용곤
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.98-104
    • /
    • 2003
  • Various nondestructive evaluation (NDE) techniques have been studied to locate steel rebars of dowel, and to detect invisible damage such as voids and cracks inside concrete and debonding between rebars and concrete caused by corrosions and earthquakes. In this study, the aurhors developed 3-dimensional (3D) electromagnetic (EM) imaging technology to detect such damage and to identify exact location of steel rebars of dowel. The authors have developed sub-surface two-dimensional (2D) imaging technique using tomographic antenna array in previous works. In this study, extending the earlier analytical and experimental works on 2D image reconstruction, a 3D microwave imaging system using tomographic antenna array was developed, and multi-frequency technique was applied to improve quality of the reconstructed image and to reduce background noises. This paper presents the analytical expressions of numerical focusing procedures for 3D image reconstruction and numerical simulation to study the resolution of the system and the effectiveness of multi-frequency technique. Also, the design of 4?4 antenna array with switching devices is introduced as a preliminary study for the final design of whole array.

Simplified Integral Imaging Pickup Method for Real Objects Using a Depth Camera

  • Li, Gang;Kwon, Ki-Chul;Shin, Gwan-Ho;Jeong, Ji-Seong;Yoo, Kwan-Hee;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.381-385
    • /
    • 2012
  • In this paper, we present a novel integral imaging pickup method. We extract each pixel's actual depth data from a real object's surface using a depth camera, then generate elemental images based on the depth map. Since the proposed method generates elemental images without a lens array, it has simplified the pickup process and overcome some disadvantages caused by a conventional optical pickup process using a lens array. As a result, we can display a three-dimensional (3D) image in integral imaging. To show the usefulness of the proposed method, an experiment is presented. Though the pickup process has been simplified in the proposed method, the experimental results reveal that it can also display a full motion parallax image the same as the image reconstructed by the conventional method. In addition, if we improve calculation speed, it will be useful in a real-time integral imaging display system.

Image Guided Radiation Therapy

  • Ui-Jung Hwang;Byong Jun Min;Meyoung Kim;Ki-Hwan Kim
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.37-52
    • /
    • 2022
  • Over the past decades, radiation therapy combined with imaging modalities that ensure optimal image guidance has revolutionized cancer treatment. The two major purposes of using imaging modalities in radiotherapy are to clearly delineate the target prior to treatment and set up the patient during radiation delivery. Image guidance secures target position prior to and during the treatment. High quality images provide an accurate definition of the treatment target and the possibility to reduce the treatment margin of the target volume, further lowering radiation toxicity and improving the quality of life of cancer patients. In this review, the various types of image guidance modalities used in radiation therapy are distinguished into ionized (kilovoltage and megavoltage image) and nonionized imaging (magnetic resonance image, ultrasound, surface imaging, and radiofrequency). The functional aspects, advantages, and limitation of imaging using these modalities are described as a subsection of each category. This review only focuses on the technological viewpoint of these modalities and any clinical aspects are omitted. Image guidance is essential, and its importance is rapidly increasing in modern radiotherapy. The most important aspect of using image guidance in clinical settings is to monitor the performance of image quality, which must be checked during the periodic quality assurance process.

Detecting colorectal lesions with image-enhanced endoscopy: an updated review from clinical trials

  • Mizuki Nagai;Sho Suzuki;Yohei Minato;Fumiaki Ishibashi;Kentaro Mochida;Ken Ohata;Tetsuo Morishita
    • Clinical Endoscopy
    • /
    • 제56권5호
    • /
    • pp.553-562
    • /
    • 2023
  • Colonoscopy plays an important role in reducing the incidence and mortality of colorectal cancer by detecting adenomas and other precancerous lesions. Image-enhanced endoscopy (IEE) increases lesion visibility by enhancing the microstructure, blood vessels, and mucosal surface color, resulting in the detection of colorectal lesions. In recent years, various IEE techniques have been used in clinical practice, each with its unique characteristics. Numerous studies have reported the effectiveness of IEE in the detection of colorectal lesions. IEEs can be divided into two broad categories according to the nature of the image: images constructed using narrow-band wavelength light, such as narrow-band imaging and blue laser imaging/blue light imaging, or color images based on white light, such as linked color imaging, texture and color enhancement imaging, and i-scan. Conversely, artificial intelligence (AI) systems, such as computer-aided diagnosis systems, have recently been developed to assist endoscopists in detecting colorectal lesions during colonoscopy. To gain a better understanding of the features of each IEE, this review presents the effectiveness of each type of IEE and their combination with AI for colorectal lesion detection by referencing the latest research data.

가상 디자인을 위한 3 차원 목표곡선을 이용한 곡면 변형 (NURBS Surface Deformation with 3D Target Curve for Virtual Design)

  • 이정인;채영호
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2006년도 학술대회 1부
    • /
    • pp.474-479
    • /
    • 2006
  • 컴퓨터 기술이 발전함에 따라 3 차원 입력시스템을 통한 모델링이 가능하게 되었다. 2 차원 시스템은 평면 입력을 공간상의 데이터로 바꾸기 위한 많은 기능과 메뉴들이 존재하지만 3 차원 시스템에서는 그러한 복잡한 기능 없이 입력 데이터가 곧바로 모델링에 적용될 수 있다. 하지만 아직까지 3 차원 입력시스템에서 모델링을 수행하는 디자이너에게 익숙한 스케치 방법을 고려하지 못하고 있는 실정이다. 디자이너에게 가장 익숙한 모델링 방법은 스케치북에 선으로 그림을 그리는 것이기 때문에, 모델을 변형하는 방법은 이를 벗어나지 않도록 해야 한다. 평면 스케치에서 디자이너가 그리는 선은 모델의 윤곽을 잡아주고 모델의 특징이 되는 부분을 표현하게 된다. 이러한 선의 입력을 통한 스케치를 3 차원 모델링에서 그대로 사용하기 위해서는 공간에서의 점이나 면이 아닌 선의 입력을 모델링에 적용할 수 있어야 한다.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A study on a development of a measurement technique for diffusion of oil spill in the ocean)

  • 이중우;김기철;강신영;도덕희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

Laser Lock-in Thermal Wave Imaging for Nondestructive Evaluation

  • An, Yun-Kyu;Sohn, Hoon;Kim, Ji Min
    • 비파괴검사학회지
    • /
    • 제33권4호
    • /
    • pp.317-322
    • /
    • 2013
  • This paper presents a new laser lock-in thermography (LLT) technique for nondestructive evaluation. LLT utilizes a modulated continuous wave laser beam as a heat source to obtain high fidelity thermal wave images even at the presence of background heat disturbances. The thermal waves propagating along the surface and through-the-thickness directions of a structure are visualized using newly developed laser lock-in amplitude and phase images, enhancing the detectability of surface and subsurface defects. The LLT technique is numerically investigated and experimentally validated using thermal images obtained from a steel specimen with low emissivity.

AFM 마이크로캔틸레버 특성에 따른 비접촉모드의 영향 고찰 (The Effects of AFM Microcantilever Characteristics on the Non-Contact Mode Measurements)

  • 홍상혁;이수일;이장무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1391-1395
    • /
    • 2006
  • In non-contact mode atomic force microscopy, the response of a resonating tip is used to measure the nanoscale topography and other properties of a sample surface. However, the tip-surface interactions can affect the tip response and destabilize the non-contact mode control. Especially it is difficult to obtain a good scanned image of high adhesion surfaces such as polymers using conventional hard NCHR tip and non-contact mode control. In this study, experimental investigation is made on the non-contact mode imaging and we report the microcantilever having low stiffness (OMCL) is useful to measure the properties of samples such as elasticity. In addition, we proved that it was adequate to use low stiffness microcantilever to obtain a good scanned image in AFM for the soft and high adhesion sample.

  • PDF