• Title/Summary/Keyword: Surface Hardness

Search Result 2,501, Processing Time 0.035 seconds

Effect of the electrolyte composition and the plating condition on the hardness of zinc deposit in the sulfate bath (황산아연욕에서 도금층 경도에 미치는 욕조성 및 도금조건의 영향)

  • 김명수;김영근
    • Journal of the Korean institute of surface engineering
    • /
    • v.33 no.5
    • /
    • pp.356-364
    • /
    • 2000
  • Factors that affect the hardness of the zinc electrodeposits in the sulfate electrolyte were investigated. The hardness of zinc deposit was enhanced by increasing the concentration of impurities such as iron and nickel in the bath that changed the crystallographic orientation of the zinc deposit from the strong basal plane to the random orientation. The increase of the concentration of sodium sulfate and current density in iron contained bath improved the hardness of zinc deposit because those were easily codeposited in zinc layer. However the increase of the concentration of sodium sulfate up to 80g/$\ell$ in the bath darkened the surface of zinc electrodeposits due to change of morphology by the codeposition of iron.

  • PDF

A STUDY ON THE CURING EFFECT OF COMPOSITE RESIN BY VISIBLE LIGHT THROUGH TOOTH SUBSTANCE (가시광선(可視光線)의 치질투과(齒質透過) 후(後) 복합(複合)레진 경도(硬度)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Bang, Sang-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.85-93
    • /
    • 1986
  • The purpose of this study was to investigate the curing effect of visible light through tooth substance, 0.5mm, 1.0mm thickness of enamel and dentin were prepared. Experimental specimen were made by Bisfil M & Silux packing into cylindrical brass mold 6.0mm in diameter, 2.0mm and 3.0mm, in height. All specimen were irradiated by visible light (Grip type) model No. SDL-50 Shofu Co.) for 30 seconds through tooth substance. Experimental groups were classified into enamel group (group 1) and dentin group (group 2) according to the thickness of tooth materials and then were divided into 2 subgroups (0.5mm group and 1.0mm group). In experimental groups, visible light irradiated to the specimen through either 0.5mm in thick or 1.0mm in think of tooth material. In Control group specimen were prepared by direct irradiation on the specimen surface of visible light without through tooth substance. The hardness was measured with a Barcol hardness tester (Barber-Colman Co. U.S.A.) for each prepared specimen. The results were as follows: 1. In control group, there were higher hardness values than those of in experimental group. 2. In experimental groups, 0.5mm groups had higher hardness values than 1.0mm groups did. 3. The hardness value at top surface of the specimen were higher than the hardness of bottom surface in each group. 4. Bisfil M had higher hardness values than Silux. 5. In all specimen of 3.0mm height polymerization effect was not occurred at bottom surface except Bisfil M in control group.

  • PDF

Effect of Experimental Fluoride Varnish upon the Vickers Hardness of Bovine Teeth (실험용 불소바니쉬가 우치의 비커스 경도에 미치는 영향)

  • Kim, Ah-Jin;Son, Ju-Lee;Oh, Seunghan;Bae, Ji-Myung
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.81-89
    • /
    • 2016
  • The purpose of this study was to evaluate the effect of the experimental and commercial fluoride varnishes on the Vickers hardness of bovine teeth. The experimental fluoride varnishes with 5 wt.% NaF were fabricated using Bis-GMA or rosin as the resin base. The components were mixed with over-head stirrer under warming up in a double boiler for 30 minutes. Four commercial fluoride varnishes (V-varnish, Flor-opal, Cavity shield, Fluor protector) were compared with the experimental fluoride varnishes. Vickers hardness was measured on the labial surface of bovine anterior teeth after applying fluoride varnish on 5th and 30th day. The surface of bovine teeth was observed with a scanning electron microscope before and after applying fluoride varnish and the change of the components on the bovine teeth surface was measured with EDX. In terms of hardness, the experimental rosin-based fluoride varnish showed significantly higher hardness on the 5th and 30th day than the control (bovine teeth without fluoride treatment)(p<0.05). EDX results showed that the fluoride content on the surface of bovine teeth treated with the experimental rosin-based fluoride varnish was highest on the 1st and 10th day. The higher hardness and fluoride content of experimental rosin-based fluoride varnish can be considered to be used as an effective fluoride varnish to prevent dental caries.

Improvement of Surface Hardness of 2205 Duplex Stainless Steel by Laser Shock Peening and Observations of Surface Changes (레이저 쇼크 피닝에 의한 2205 듀플렉스 스테인리스강의 표면 경도 향상과 표면 변화 관찰)

  • Lim, H.T.;Jeong, H.M.;Kim, P.K.;Jeong, Sung-Ho
    • Laser Solutions
    • /
    • v.14 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • This work reports the results for laser shock peening of duplex stainless steel (22% Chromium - 5% Nickel) using a pulsed Nd:YAG laser (wavelength = 532nm, pulse width = 8ns). for the application to high-capacity pumps for seawater desalination plants. By properly selecting the process parameters such as laser intensity of 10GW/$cm^2$, laser pulse density of 75pulse/$mm^2$, and $100{\mu}m$ thick aluminum foil as an absorbent coating layer, the surface hardness of duplex stainless steel could be enhanced by 26%, from 256HV to 323HV with little changes in surface morphology and roughness. The depth of laser shock peened layer was measured to be around 2mm. The large enhancement of surface hardness is considered to have high practical importance in minimizing abrasive and corrosive deterioration of pump parts.

  • PDF

Improvement of Surface Morphology by Precision Particle Process for Cold Die Steel Alloy (냉간금형용 합금강의 정밀입자가공에 의한 표면정밀도 향상)

  • Wang, Duck-Hyun;Kim, Won-Il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.4
    • /
    • pp.367-372
    • /
    • 2002
  • Experimental study was conducted for lapping process after WEDMed specimen. In order to decide the lapping depth of the specimen, the number of the grain size was increased from 400, 600 to 800 to obtain the better surface. Observation of scanning electron microscope, hardness test, surface roughness test and energy dispersive spectrum(EDS) analysis were used for this experimental study. From the comparison and analyses of the results of between the wire-cut electrical discharge machining and the lapping, the following results were obtained. The surface roughness after lapping was found to be improved as increasing the number of lapping process like 1st, 2nd, 3rd lapping and the number of grain size such as 400, 600, 800. The surface hardness after increasing the lapping depth of the specimen was slowly increased. It was found that after 3rd lapping process the hardness was reached the hardness of original base material. It was found that the small amount of coating components within 3% was remained after the 1st lapping process, compared to that approximately 16% after WEDM process.

  • PDF

Fabrication of Low Carbon Steel Coated with 18%Cr-2.5%Ni-Fe Powder by Laser Cladding and Its Application on Plastic Injection Mold for Aluminum Diecasting

  • Kim, Cheol-Woo;Yoo, Hyo-Sang;Cho, Kyun-Taek;Jeon, Jae-Yeol;Choi, Se-Weon;Kim, Young-Chan
    • Korean Journal of Materials Research
    • /
    • v.31 no.11
    • /
    • pp.601-607
    • /
    • 2021
  • Laser cladding a surface treatment process that grants superior characteristics such as toughness, hardness, and corrosion resistance to the surface, and rebuilds cracked molds; as such, it can be a strong tool to prolong service life of mold steel. Furthermore, compared with the other similar coating processes - thermal spray, etc., laser cladding provides superior bonding strength and precision coating on a local area. In this study, surface characteristics are studied after laser cladding of low carbon steel using 18%Cr-2.5%Ni-Fe powder (Rockit404), known for its high hardness and excellent corrosion resistance. A diode laser with wavelength of 900-1070 nm is adopted as laser source under argon atmosphere; electrical power for the laser cladding process is 5, 6, and 10 kW. Fundamental surface characteristics such as crossectional microstructure and hardness profile are observed and measured, and special evaluation, such as a soldering test with molten ALDC12 alloy, is conducted to investigate the corrosion resistance characteristics. As a result of the die-soldering test by immersion of low carbon alloy steel in ALDC12 molten metal, the clad layer's soldering thickness decreases.

A study on the change of root surface irradiated by Er:YAG laser (Er:YAG laser를 조사한 치근면의 변화에 관한 연구)

  • Lee, Sang-Hyun;Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.303-314
    • /
    • 2002
  • This study was performed to evaluate the usability of Er:YAG laser for periodontal therapy. Forty dental root slabs ($5{\times}5{\times}2mm^3$) were prepared from human periodontally diseased extracted teeth and grouped into 4 groups: 1) control (root planing only), 2) root planing and irradiated with laser at 30mJ, 3) root planing and irradiated with laser at 60mJ, and 4) root planing and irradiated with laser at 100mJ. The root slabs were embedded in resin block before laser treatment. Er:YAG laser was irradiated under water irrigation with the tip held perpendicular to the root surface in contact mode. After Er:YAG laser irradiation or planing on the root surface, morphological changes have been observed under SEM, and the micro-hardness and Ca/P ratio were compared. 1. In the Control group, the root surface showed the directional change caused by root planing instrumentation, and the presence of smear layer, and no exposure of dentinal tubule was observed. Laser irradiated group showed surface changes with rough dentin surface of niche and depression and dentinal tubule exposure by the elimination of smear layer. 2. The micro-hardness of root surface in the laser irradiated group was higher than the control group. The higher energy output was applied, the higher micro-hardness on root surface was resulted. 3. The higher energy output was applied, the higher Ca/P ratio was observed. The higher Ca/P ratio in 60mJ group and 100mJ group was statistically significantly compared to the control group and the 30mJ group. These results suggest that Er:YAG laser irradiation on the periodontally diseased root surface could remove smear layer and increase the micro-hardness on root surface and Ca/P ratio which contribute to enhance the acid resistance of periodontally treated root surface.

Frictional Characteristics of Wire Electric Discharge Machined STDll Surface (STD11 와이어 방전가공면의 마찰특성)

  • 김영욱;조성산
    • Tribology and Lubricants
    • /
    • v.16 no.4
    • /
    • pp.253-258
    • /
    • 2000
  • Frictional behavior of wire electric discharge machined surfaces of spheroidized annealed STDll steel was investigated. The surfaces were produced with a various series of finish cuts where pulse energy was reduced with increase in the number of finish cuts. Roughness and micro-hardness of the surfaces were also measured. It is observed that the increase in the number of finish cuts produces the surface exhibiting lower frictional resistance followed by higher resistance after considerable wear. Effects of finish cuts on the friction characteristics are discussed with the aid of roughness and micro-hardness of the surfaces.

Surface Quality and Corrosion of Additively Manufactured STS316L Treated by Ultrasonic Nanocrystal Surface Modification (적층제조된 스테인레스 316L에 대한 초음파나노표면개질에 따른 표면특성 및 부식성에 관한 연구)

  • Kim, Jun-Ho;Oh, Yeong-Taek;Park, Han-Byeol;Lee, Dong-Ho;Kim, Hwa-Jeong;Kim, Ui-Jun;Shim, Do-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.94-103
    • /
    • 2020
  • This study investigated the effects of ultrasonic nanocrystal surface modification (UNSM) on the deteriorated surface of AISI SUS316L additively manufactured (AM) using the powder bed fusion (PBF) technique. Specifically, the effects of UNSM conditions on surface topology, hardness, and anti-corrosion were examined. Before UNSM treatment, the stainless steel 316L powder was processed via the PBF machine to prepare a substrate. We observed surface changes due to UNSM treatments in PBF SUS316L substrates and examined the correlation between topology changes, roughness, hardness, and anti-corrosion. After UNSM treatment, the coarse as-built surface was refined, and a regular micro-profile was implemented. Compared to the non-treated PBF sample, the waviness and roughness of the surfaces after UNSM treatment decreased by up to 56.0% and 94.5%, respectively, and decreased further as the interval decreased. The hardness improved by up to 63.0% at a maximum depth of 500 ㎛ from top surface by the UNSM treatment. The results of the corrosion test showed that the corrosion resistance of the UNSM specimens was moderately improved compared to that of the untreated surface. This study confirmed that UNSM is an effective post-processing technique for additively manufactured parts.

Finishing and polishing effects of multiblade burs on the surface texture of 5 resin composites: microhardness and roughness testing

  • Ehrmann, Elodie;Medioni, Etienne;Brulat-Bouchard, Nathalie
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.1.1-1.12
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to test the effect of 2 finishing-polishing sequences (QB, combining a 12/15-fluted finishing bur and an EVO-Light polisher; QWB, adding a 30-fluted polishing bur after the 12/15-fluted finishing bur used in the QB sequence) on 5 nanotech-based resin composites (Filtek Z500, Ceram X Mono, Ceram X Duo, Tetric Evoceram, and Tetric Evoceram Bulk Fill) by comparing their final surface roughness and hardness values to those of a Mylar strip control group (MS). Materials and Methods: Twelve specimens of each nanocomposite were prepared in Teflon moulds. The surface of each resin composite was finished with QB (5 samples), QWB (5 samples), or MS (2 samples), and then evaluated (60 samples). Roughness was analysed with an optical profilometer, microhardness was tested with a Vickers indenter, and the surfaces were examined by optical and scanning electron microscopy. Data were analysed using the Kruskal-Wallis test (p < 0.05) followed by the Dunn test. Results: For the hardness and roughness of nanocomposite resin, the QWB sequence was significantly more effective than QB (p < 0.05). The Filtek Z500 showed significantly harder surfaces regardless of the finishing-polishing sequence (p < 0.05). Conclusions: QWB yielded the best values of surface roughness and hardness. The hardness and roughness of the 5 nanocomposites presented less significant differences when QWB was used.