• 제목/요약/키워드: Surface Effective Dose

검색결과 139건 처리시간 0.039초

Multivariate statistical study on naturally occurring radioactive materials and radiation hazards in lakes around a Chinese petroleum industrial area

  • Yan Shi;Junfeng Zhao;Baiyao Ding;Yue Zhang;Zhigang Li;Mohsen M.M.Ali;Tuya Siqin;Hongtao Zhao;Yongjun Liu;Weiguo Jiang;Peng Wu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2182-2189
    • /
    • 2024
  • The high-purity germanium gamma-ray spectrometer was used to measure the radioisotope in surface water of lakes in a Chinee petroleum industrial area. 92 samples were collected from surface water of three lakes. Activity concentrations of 232Th, 226Ra and 40K in three lakes were measured, distributed in the range of 101.8-209.4, 192.1-224.9 and 335.0-548.9 mBq/L, respectively. Results were all within the limits of WHO and China. Potential environmental and health risks were assessed by calculating some radiation hazard indicators, radium equivalent index, annual effective dose, excess lifetime cancer risk, absorbed dose rate, external hazard index, internal hazard index, annual gonadal dose equivalent, activity utilization index and representative gamma index, which ranged 0.38-0.54 Bq/L, 0.06-0.08 mSv/y, 0.23 × 10-3-0.31 × 10-3, 0.17-0.24 nGy/h, 1.01 × 10-3-1.46 × 10-3, 1.55 × 10-3-2.02 × 10-3, 1.16-1.66 μSv/y, 3.13 × 10-3-4.45 × 10-3 and 2.60 × 10-3-3.77 × 10-3. The results were all at acceptable levels, meaning no impact on human health. The relationship between the electrical conductivity of surface water and the activity concentration of 232Th, 226Ra and 40K was evaluated. The electrical conductivity value was 0.241-0.369 mS/cm, showing a significant correlation coefficient between 226Ra and 40K and electrical conductivity. Multivariate statistical methods were used to determine the relationship between the activity concentrations of 232Th, 226Ra, and 40K, radiation hazard indicators and electrical conductivity.

선량계측인자에 따른 기능강화동적쐐기와 금속쐐기의 비교 (Comparison of Enhanced Dynamic Wedge with Physical Metal Wedge based on the Basic Dosimetric Parameters)

  • 이정우;홍세미;최경식;정진범;최보영;장홍석;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2005
  • 기능강화동적쐐기는 쐐기 형태의 선량 분포를 만드는 방법과 선량 특성적인 면에서 금속쐐기와 상당한 차이를 가지고 있다. 기능강화동적쐐기의 임상적용을 위해서는 금속쐐기와 다른 선량특성을 분석하고 이에 따른 적절한 커미셔닝이 필수적이다. 본 연구의 목적은 기본 선량계측인자에 기초한 기능강화동적래기와 금속쐐기의 선량특성을 분석하는 데 있다 선량 계측학적 특성을 나타내는 심부선량분포, 조사면 주변 선량, 표면선량, 실효 쐐기인자, 쐐기의 선량측면도를 측정, 분석하였다. 또한 열린 조사면과 금속쐐기와의 비교측정을 통해 기능강화동적쐐기가 가지고 있는 고유한 특성을 분석하였다. 기능강화동적쐐기의 선량측면도 측정은 Chamber Array 24 (CP24)를 이용하였으며, Golden Segmented Treatment Table (Golden-577)로 구현한 치료 계획 장치의 계산 값과 비교하였다. 또한 실호쐐기인자 측정은 각각의 X, Y 콜리메이터에 따른 특성을 분석하였다. 심부 선량 백분율측정에서 열린 조사면과 기능강화쐐기의 비교결과, $0.2\~0.5\%$ 이내로 일치하였고, 금속 쐐기인 경우 약 $2\%$의 비교적 큰 차이를 보였다. 조사면 주변선량측정에서는 금속쐐기가 약 $1\%$ 높았다. 표면선량 측정 결과, 금속쐐기가 약 $10\%$ 낮게 평가되었다 기능강화쐐기의 실효쐐기인자는 Y jaw가 커짐에 따라 연속적으로 감소됨을 알 수 있었다. X jaw에 따른 쐐기인자 의존도 측정에서는 X jaw에 따른 의존도는 거의 없는 것으로 평가되었다. 또한 비대칭 조사면의 쐐기 인자측정에서는 비대칭에 상관없이 Y jaw의 크기만 같으면 실효쐐기인자가 같았다. 선량측면도 측정에서는 CA24를 이용해 얻은 실측값과 Golden STT로 Cadplan에서 구현한 계산 값이 $1\%$이내로 일치하였다. 본 연구를 통해 기능강화동적쐐기가 가지고 있는 특성을 분석하였으며, 금속쐐기를 대체할 수 있는 유용한 도구임을 알 수 있었다.

  • PDF

플라스마 이온증착 기술을 이용한 스테인리스강의 질화처리에 관한 연구 (Research of Nitriding Process on Austenite Stainless Steel with Plasma Immersion Ion Beam)

  • 김재돌;박일수;옥철호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.262-267
    • /
    • 2008
  • Plasma immersion ion beam (PIIB) nitriding process is an environmentally benign and cost-effective process, and offers the potential of producing high dose of nitrogen ions in a way of simple, fast and economic technique for the high plasma flux treatment of large surface area with nitrogen ion source gas. In this report PIIB nitriding technique was used for nitriding on austenite stainless steel of AISI304 with plasma treatment at $250{\sim}500^{\circ}C$ for 4 hours, and with the working gas pressure of $2.67{\times}10^{-1}$ Pa in vacuum condition. This PIIB process might prove the advantage of the low energy high flux of ion bombardment and enhance the tribological or mechanical properties of austenite stainless steel by nitriding, Furthermore, PIIB showed a useful surface modification technique for the nitriding an irregularly shaped three dimensional workpiece of austenite stainless steel and for the improvement of surface properties of AISI 304, such as hardness and strength

GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션 (Safety Simulation of Therapeutic I-131 Capsule Using GEANT4)

  • 정영환;김병철;심철민;서한경;권용주;한동현
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.57-61
    • /
    • 2014
  • 국내 갑상선암 환자의 발병률이 증가함에 따라 방사성요오드 치료가 필요한 환자가 증가하고 있다. 방사성 요오드 치료에 이용되고 있는 캡슐용기들 중 1.1 GBq과 5.5 GBq의 국산제품에 설계도면을 바탕으로 차폐체를 구현한 후 366 keV 이상에 감마선들에 대하여 캡슐용기의 방사선 누설선량을 GEANT4 전사모사를 이용하여 평가하였다. 치료용 I-131 캡슐용기 누설선량을 측정하기 위해 각각의 용기에 대하여 용기 표면에서 10 cm 거리 및 100 cm 거리에서의 누설선량을 측정하였다. 용기표면에서 10 cm 거리와 100 cm 거리에서의 누설선량 측정은 방사형으로 발생되는 방사선을 위치별로 측정하기 위해 $10{\times}10{\times}10cm^3$ 부피의 정육면체 형태의 물 팬텀(phantom)을 상부, 상부측면, 측면, 하부측면, 하부 다섯 방향에 설치하여 누설선량을 계산하였다. 용기별로 5개 방향에서 용기표면으로 부터 10 cm, 100 cm 거리에서 전산모사를 수행한 결과 법적 허용기준인 10 cm 거리에서 2.0 mSv/h, 100 cm 거리에서 0.02 mSv/h 이하의 선량 규정과 비교하였을 때 법적기준치보다 현저히 낮은 누설선량이 방출되는 것을 확인하였다.

  • PDF

자외선 경화에 의한 PET 니트직물의 편면 발수발유 가공 (Preferential face coating of knitted PET fabrics via UV curing for water- and oil-repellent finish)

  • 정용균;정영진;장진호
    • 한국염색가공학회지
    • /
    • 제17권6호
    • /
    • pp.27-35
    • /
    • 2005
  • Conventional pad- dry-cure(thermo-fixation) process usually produces functional performance on both sides of a fabric. UV curing technique was applied to impart water- and oil-repellent finish effective only on the face of a PET knitted fabric. The preferential one-side coating, by virtue of the limited penetration of UV light, was achieved by W curing after padding of a fluorocarbon agent without special coating or printing equipments. The difference in the functional property of face and back sides was examined by measuring water and oil repellency at each side of the treated fabric. The influence of pre/post-irradiation dose and agent concentration on the performance of the finished fabrics were investigated. While increase in both resin concentration and post-irradiation did not have significant effect on the finish, UV pre-irradiation of PET fabrics caused remarkable influence presumably due to appropriate surface modification of PET fabrics required for facile wetting of the resin. The dimensional stability and color change of the UV cured fabrics measured by FAST and reflectance spectrophotometry showed significantly decreased color difference and increased percent extension compared with the samples pre-irradiated without agent application.

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

Plasma를 이용한 세정액의 활성화와 시료 표면의 탄성계수 및 강도 변화에 대한 연구 (Activation of Stripper Solution by Plasma and Hardness/Modulus of Elasticity Change of the Surface)

  • 김수인;김현우;노성철;윤덕진;장홍준;이종림;이창우
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.97-101
    • /
    • 2009
  • 현대의 반도체 산업에서 공정 중 가장 큰 비중을 차지하며, 가장 많은 자본과 인력을 소비하는 것이 바로 세정 공정이다. 세정공정은 소자의 작동에 영향을 미치고 기능을 저하시킬 수 있는 이물질 입자들을 제거하는 것이다. 특히 소자를 식각하기 위한 Photoresist(PR) 과정이 끝날 때마다 항상 세정 과정이 포함되어야 했다. 또한, Photoresist(PR) 공정 중 생성된 HDI-PR(high dose implanted photoresist)은 세정 과정에서 제거가 힘들기 때문에 현대의 고밀도 집적회로 세정 공정에서는 건식 세정과 습식 세정을 혼용하여 여러 단계의 세정 공정을 거치게 된다. 이 논문에서는 기존 플라즈마 방식으로 대표되는 건식 세정과 약액으로 대표되는 습식 세정을 동시에 사용하는 방식을 사용하여 약액활성화 방법(Plasma Liquid-Vapor Activation; PLVA)을 제안하여 실험을 실시하였고 HDI-PR을 활성화된 용액에 담근 후 Nano-Indenter를 이용하여 표면강도와 탄성계수를 측정했다. Nano-indenter는 특정한 기하학적 형태를 가지는 Tip을 표면에 압입한 후 압입하중과 압입깊이를 측정함으로서 시료의 표면강도와 탄성계수를 측정하였다. 그 결과 plasma로 활성화된 PR stripper 용액으로 strip한 후의 시료의 표면 강도가 크게 줄어든 것을 확인하였다. 이는 이후 물리적 표면 세정 공정을 후 공정으로 사용한다면 보다 효율적인 HDI-PR을 제거할 수 있을 것으로 사료된다.

GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사 (Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6)

  • 안수정;이창래;백철하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.571-575
    • /
    • 2016
  • 본 연구에서는 몬테칼로 전산모사 코드인 GATE6 (Geant4 Application for Tomographic Emission ver.6)를 사용하여 의료용 선형 가속기인 Varian사의 Clinac 21EX를 모사하고, 6 MV 광자선의 선량 특성을 평가하였다. 몬테칼로 방법은 방사선 치료시 환자 내의 선량분포를 계산하는 가장 정확한 방법으로 널리 이용되고 있다. 몬테칼로 기반의 코드를 이용하여 선형가속기의 조사 헤드부를 통과하는 입자의 흐름을 모사하는 것은 조사선량을 정량화 하는데 필요한 입자들의 에너지, 공간 분포와 같은 임상적인 빔의 특성을 결정하기 위한 실용적인 방법이다. 본 연구에서 모사한 선형가속기의 조사 헤드부는 빔 경로에 위치한 타겟, 일차 콜리메이터, 선속 평탄 필터, 이온전리함, 이차 콜리메이터로 구성된다. 모사된 선형가속기를 이용하여 선원-표면간 거리 100 cm, 조사야 $10{\times}10cm^2$ 조건에서 물팬텀 내의 광자선 에너지 스펙트럼(energy spectrum), 심부선량백분율(percentage depth dose), 선량프로파일(dose profiles)을 측정하였으며, 이 결과값을 실험 측정값과 비교하여 정확성을 검증하였다. 본 연구에서는 모사를 통한 결과값과 실험값이 매우 일치함을 보였으며, 이를 통해 GATE6 전산모사 코드는 방사선치료에 사용되는 광자선을 모사하기에 효과적임을 입증하였다.

피부 T 세포림프종의 전 피부 전자선 치료를 위한 dosimetry 연구 (A Study on the Dosimetry of the Total Skin Electron Beam Therapy in Cutaneous T-Cell Lymphoma)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.57-65
    • /
    • 1996
  • 피부 T 세포림프종에 대하여 4MeV 의 전자선으로 전 피부 방사선 조사를 시행하였다. 피부전체의 균일한 선량분포를 위하여 스탠포드대학의 방법으로 알려져 있는 six dual field 기법을 사용하였다. SSD 는 390cm로 하였으며 방사선 조사시의 gantry 의 각은 환자의 중심을 지나는 수평축에 대하여 상ㆍ하로 14$^{\circ}$가 되도록 하였다. 전자콘을 설치해야만 전자선 조사가 가능하므로 최대의 전자콘인 25$\times$25cm콘을 사용하였다. 치료면에서의 선량분포의 균일성을 확인하기 위하여 치료면에 90$\times$180cm의 폴리스틸렌을 설치하고 Famer type ion chamber와 측정용 필름을 사용하여 측정하였다. 그 결과 치료면에서 10% 정도의 균일함을 보였다. 환자의 자세를 하루에 세가지씩 이틀에 걸쳐 여섯가지 자세를 한 주기로 치료를 시행하였다. 선량이 부족한 정수리, 회음부, 발바닥 등은 따로 추가의 방사선을 조사하였다. 렌즈와 손톱, 발톱은 차폐물을 제작하여 차폐하였다.

  • PDF

PLVA 방법을 활용한 PR Stripper의 성능 향상과 HDI-PR 표면의 내력 변화 연구 (Improvement of PR Stripper Efficient and Change of Surface Hardness for HDI-PR Used by PLVA Method)

  • 김수인;이창우
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.544-548
    • /
    • 2008
  • 반도체 공정에서 가장 많은 시간과 비용을 차지하는 공정 중 하나는 Photoresist strip 공정이다. 따라서 보다 빠르게 PR의 strip 공정을 단축하기 위한 연구가 계속 진행중에 있다. 하지만 기존 사용중인 strip용액을 대체하기 위한 물질을 찾는 것은 많은 비용을 수반한다. 본 연구에서는 PR의 strip 시간을 최대한 단축시키고 PR strip 잔여물의 빠른 제거를 위하여 기존 공정에서 사용 중인 strip 약액을 플라즈마에 의하여 활성화하는 방법(Plasma Liquid-Vapor Activation: PLVA)으로 PR strip 시간을 최대한 줄이는 방법에 대한 연구를 진행하였으며, 활성화된 strip용액이 더욱 빠른 strip율 성능을 나타내는 것을 확인하였다. 또한 PR strip에서 이온에 의한 영향을 받은 HDI-PR (high dose implanted photoresist)은 기존 strip용액으로 제거가 불가능하였다. 하지만 본 연구에서 제시한 PLVA 방법으로 활성화된 용액에서는 그 가능성을 확인하였고, 이러한 PLVA방법에 대한 물리적 연구를 위하여 HDI-PR 표면 내력의 변화를 측정하였다. 그 결과 PLVA 처리 전 후 HDI-PR의 표면 내력에 큰 변화를 확인하였다.