• Title/Summary/Keyword: Surface Defects

Search Result 1,483, Processing Time 0.032 seconds

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

THE EFFECT OF NEW BONE FORMATION OF ONLAY BONE GRAFT USING VARIOUS GRAFT MATERIALS WITH A TITANIUM CAP ON THE RABBIT CALVARIUM (가토의 두개골에서 티타늄 반구를 이용한 다양한 onlay bone graft시 골형성 능력)

  • Park, Young-Jun;Choi, Guen-Ho;Jang, Jung-Rok;Jung, Seung-Gon;Han, Man-Seung;Yu, Min-Gi;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.469-477
    • /
    • 2009
  • Purpose: This study was performed to evaluate the effect of various graft materials used with a titanium cap on the ability of new bone formation in the rabbit calvarium. Materials and Methods: A total of 32 sites of artificial bony defects were prepared on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter. Each rabbit had two defect sites. 0.2 mm deep grooves were formed on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter for the fixation of a titanium cap. The treatments were performed respectively as follows: without any graft for the control group (n=8), autogenous iliac bone graft for experimental group 1 (n=8), alloplastic bone graft ($SynthoGraft^{(R)}$, USA) for experimental group 2 (n=8), and xenogenic bone graft ($NuOss^{(R)}$, USA) for experimental group 3 (n=8). After the treatments, a titanium cap (8 mm in diameter, 4 mm high, and 0.2 mm thick) was fixed into the groove. At the third and sixth postoperative weeks, rabbits in each group were sacrificed for histological analysis. Results: 1. In gross examination, the surgical sites showed no signs of inflammation or wound dehiscence, and semicircular-shaped bone remodeling was shown both in the experimental and control groups. 2. In histological analysis, the control group at the third week showed bone remodeling along the inner surface of the cap and at the contact region of the calvarium without any specific infiltration of inflammation tissue. Also, there was no soft tissue infiltration. Bone remodeling was observed around the grafted bone and along the inner surface of the titanium cap in experimental group 1, 2, and 3. 3. Histologically, all groups at the sixth week showed the increased area of bone remodeling and maturation compared to those at the third week. In experimental group 2, the grafted bone was partially absorbed by multi nucleated giant cells and new bone was formed by osteoblasts. In group 3, however, resorption of the grafted bone was not observed. 4. Autogenous bone at the third and sixth week showed the most powerful ability of new bone formation. The size of newly formed bone was in decreasing order by autogenous, alloplastic, and heterogenous bone graft. There was no statistically significant difference among autogenous, alloplastic, and heterogenous bones(p>0.05). Summary: This result suggests that autogenous bone is the best choice for new bone formation, but when autogenous bone graft is in limited availability, alloplastic and xenogenic bone graft also can be an alternative bone graft material to use with a suitably guided membrane.

National Survey of Injury and Poisoning on a Representative Sample Population of Koreans (우리나라 대표적(代表的) 표본인구(標本人口)의 연간(年間) 손상(損傷) 및 중독발생율(中毒發生率)과 역학적(疫學的) 특성(特性))

  • Kim, Joung-Soon;Kim, Sung-Soo;Chang, Sung-Chill
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.447-463
    • /
    • 1994
  • Despite the public health importance of injury and poisoning in terms of its high mortality and incidence, epidemiologic information to be utilized are scarce in Korea. This study was carried out in 1990 on a representative sample population (about 55,000 persons) along with the 6th National Tuberculosis Prevalence Survey in order to estimate the magnitude of injury and poisoning occurrence and to identify its epidemiologic characteristics which can be aided for establishing preventive strategy. Pre-tested and structured Questionnaire was used by trained interviewer to collect data including general information of the person, various information on the injury and poisoning during the past one year such as time and place of its occurrence, its nature and external causes, type of medical institute attended, duration of treatment and outcome of the accident occured. In analysis of the data collected incidence rates per 1000 persons by sex, age group and its nature as well as external causes, and relative frequencies were calculated. The result obtained are as followings; 1. The incidence rate per 1000 was 30 for both sexes, 39 for male and 22 for female, male being 1.8 times more frequent than female. Age adjusted incidences were not much different from the crude rates. Age group specific rate curve showed bimodal shape in both sexes, small peaks in preschool children and higher peaks in older ages. The incidence rate per 1000 people by area was highest in Jeon-bug province (57/1000) and the lowest in Daegu city(11/1000). 2. The place where the injuries occured were road in 46%, within the boundary of house in 25%, and working place in 12% The injuries and poisoning had occured more frequently during the months from March to August of the year than other months. 3. The relatively frequent injuries by its nature were contusion with intact skin surface (19%), fracture of upper limb (13%), open wound of head, neck and trunk (12%) and fracture of lower limb (11%) among males; contusion with intact skin surface (28%), sprains and strains of joints and adjacent muscle (14%), fracture of upper limb (10%) and fracture of lower limb (9%) among females. Higher incidence rate among males than females were fracture of skull (4.5 times), open wound and fractures of limbs ($2{\sim}3$ times). Age specific rate of injuries and poisoning by its nature showed increasing pattern by age in fractures of upper and lower limbs and sprains & strains of joints whereas the age group of 30's showed highest incidence in open wounds of upper limb. Fractures of radius and ulna in upper limb, fractures of tibia & fibula and ankle in lower limb were most frequent among fractures of upper and lower limbs. The frequent injuries among sprains and strains of joints and adjacent muscles were that of ankle, foot and back, and among open wound were that of head and fingers. 4. Relative frequency of injuries and poisoning by external causes showed following order : other accidents (25%), accidental falls (23%), motor vehicle accident (22%) and other road vehicle accident (14%) among males and accidental falls (37%), motor vehicle accident (24%) and other accident (18%) among females. The external causes revealing higher incidences among males than females, were other road vehicle accident (4.8 times), vehicle accident not elsewhere classifiable (4.4 times), accidental poisoning (4.4 times), accidents due to natural and environmental factors (2.8 times), and sucide & self-inflicted injuries (2.8 times). Age specific incidence by external causes for frequent injuries showed that incidence of other accident steadily increased from 10's till age 50's; motor vehicle traffic accident increased from age 20's and dropped after age 60's; on the other hand accidental fall increased strikingly by age. The most frequent external causes among motor vehicle traffic accidents was motor vehicle traffic accident involving collision with pedstrain (69%), pedal cycle accident (30%) and other road vehicle accident (71%) among other road vehicle accidents; falls on same level from slipping, tripping or standing (44%) and other falls from one level to another among accidental falls; accidents caused by machinary (32%) for male and striking against or struck accidentally by objects or person for female among other accidents. 5. Seventy nine percent of the injuries and poisonings were treated in general hospital or hospital/clinic. The duration of treatment ranged from a few days to 123 weeks; the majority(52%) took under 2 weeks, 36% for $3{\sim}8$ weeks and 4% over 21 weeks. 6. The accident resulted in full recovery of normal healthy state in 62%, residual functional defects in 21% and on process of treatment in 16%.

  • PDF

1H Solid-state NMR Methodology Study for the Quantification of Water Content of Amorphous Silica Nanoparticles Depending on Relative Humidity (상대습도에 따른 비정질 규산염 나노입자의 함수량 정량 분석을 위한 1H 고상 핵자기 공명 분광분석 방법론 연구)

  • Oh, Sol Bi;Kim, Hyun Na
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.1
    • /
    • pp.31-40
    • /
    • 2021
  • The hydrogen in nominally anhydrous mineral is known to be associated with lattice defects, but it also can exist in the form of water and hydroxyl groups on the large surface of the nanoscale particles. In this study, we investigate the effectiveness of 1H solid-state nuclear magnetic resonance (NMR) spectroscopy as a robust experimental method to quantify the hydrogen atomic environments of amorphous silica nanoparticles with varying relative humidity. Amorphous silica nanoparticles were packed into NMR rotors in a temperature-humidity controlled glove box, then stored in different atmospheric conditions with 25% and 70% relative humidity for 2~10 days until 1H NMR experiments, and a slight difference was observed in 1H NMR spectra. These results indicate that amount of hydrous species in the sample packed in the NMR rotor is rarely changed by the external atmosphere. The amount of hydrogen atom, especially the amount of physisorbed water may vary in the range of ~10% due to the temporal and spatial inhomogeneity of relative humidity in the glove box. The quantitative analysis of 1H NMR spectra shows that the amount of hydrogen atom in amorphous silica nanoparticles linearly increases as the relative humidity increases. These results imply that the sample sealing capability of the NMR rotor is sufficient to preserve the hydrous environments of samples, and is suitable for the quantitative measurement of water content of ultrafine nominally anhydrous minerals depending on the atmospheric relative humidity. We expect that 1H solid-state NMR method is suitable to investigate systematically the effect of surface area and crystallinity on the water content of diverse nano-sized nominally anhydrous minerals with varying relative humidity.

Effects of High Glucose and Advanced Glycosylation Endproducts(AGE) on the in vitro Permeability Model (당과 후기당화합물의 생체 외 사구체여과율 모델에 대한 역할)

  • Lee Jun-Ho;Ha Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2006
  • Purpose : We describe the changes of rat glomerular epithelial cells when exposed to high levels of glucose and advanced glycosylation endproducts(AGE) in the in vitro diabetic condition. We expect morphological alteration of glomerular epithelial cells and permeability changes experimentally and we may correlate the results with a mechanism of proteinuria in DM. Methods : We made 0.2 M glucose-6-phsphate solution mixed with PBS(pH 7.4) containing 50 mg/mL BSA and pretense inhibitor for preparation of AGE. As control, we used BSA. We manufactured and symbolized five culture dishes as follows; B5 - normal glucose(5 mM) + BSA, B30 - high glucose(30 mM) + BSA, A5 - normal glucose(5 mM) + AGE, A30 - high glucose(30 mM) + AGE, A/B 25 - normal glucose(5 mM) + 25 mM of mannitol(osmotic control). After the incubation period of both two days and seven days, we measured the amount of heparan sulfate proteoglycan(HSPG) in each dish by ELISA and compared them with the B5 dish at 2nd and 7th incubation days. We observed the morphological changes of epithelial cells in each culture dish using scanning electron microscopy(SEM). We tried the permeability assay of glomerular epithelial cells using cellulose semi-permeable membrane measuring the amount of filtered BSA through the apical chamber for 2 hours by sandwich ELISA. Results : On the 2nd incubation day, there was no significant difference in the amount of HSPG between the 5 culture dishes. But on the 7th incubation day, the amount of HSPG increased by 10% compared with the B5 dish on the 2nd day except the A30 dish(P<0.05). Compared with the B5 dish on the 7th day the amount of HSPG in A30 and B30 dish decreased to 77.8% and 95.3% of baseline, respectively(P>0.05). In the osmotic control group (A/B 25) no significant correlation was observed. On the SEM, we could see the separated intercellular junction and fused microvilli of glomerular epithelial cells in the culture dishes where AGE was added. The permeability of BSA increased by 19% only in the A30 dish on the 7th day compared with B5 dish on the 7th day in the permeability assay(P<0.05). Conclusion: We observed not only the role of a high level of glucose and AGE in decreasing the production of HSPG of glomerular epithelial cells in vitro, but also their additive effect. However, the role of AGE is greater than that of glucose. These results seems to correlate with the defects in charge selective barrier. Morphological changes of the disruption of intercellular junction and fused microvilli of glomerular epithelial cells seem to correlate with the defects in size-selective barrier. Therefore, we can explain the increased permeability of glomerular epithelial units in the in vitro diabetic condition.

  • PDF

Steel Plate Faults Diagnosis with S-MTS (S-MTS를 이용한 강판의 표면 결함 진단)

  • Kim, Joon-Young;Cha, Jae-Min;Shin, Junguk;Yeom, Choongsub
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.47-67
    • /
    • 2017
  • Steel plate faults is one of important factors to affect the quality and price of the steel plates. So far many steelmakers generally have used visual inspection method that could be based on an inspector's intuition or experience. Specifically, the inspector checks the steel plate faults by looking the surface of the steel plates. However, the accuracy of this method is critically low that it can cause errors above 30% in judgment. Therefore, accurate steel plate faults diagnosis system has been continuously required in the industry. In order to meet the needs, this study proposed a new steel plate faults diagnosis system using Simultaneous MTS (S-MTS), which is an advanced Mahalanobis Taguchi System (MTS) algorithm, to classify various surface defects of the steel plates. MTS has generally been used to solve binary classification problems in various fields, but MTS was not used for multiclass classification due to its low accuracy. The reason is that only one mahalanobis space is established in the MTS. In contrast, S-MTS is suitable for multi-class classification. That is, S-MTS establishes individual mahalanobis space for each class. 'Simultaneous' implies comparing mahalanobis distances at the same time. The proposed steel plate faults diagnosis system was developed in four main stages. In the first stage, after various reference groups and related variables are defined, data of the steel plate faults is collected and used to establish the individual mahalanobis space per the reference groups and construct the full measurement scale. In the second stage, the mahalanobis distances of test groups is calculated based on the established mahalanobis spaces of the reference groups. Then, appropriateness of the spaces is verified by examining the separability of the mahalanobis diatances. In the third stage, orthogonal arrays and Signal-to-Noise (SN) ratio of dynamic type are applied for variable optimization. Also, Overall SN ratio gain is derived from the SN ratio and SN ratio gain. If the derived overall SN ratio gain is negative, it means that the variable should be removed. However, the variable with the positive gain may be considered as worth keeping. Finally, in the fourth stage, the measurement scale that is composed of selected useful variables is reconstructed. Next, an experimental test should be implemented to verify the ability of multi-class classification and thus the accuracy of the classification is acquired. If the accuracy is acceptable, this diagnosis system can be used for future applications. Also, this study compared the accuracy of the proposed steel plate faults diagnosis system with that of other popular classification algorithms including Decision Tree, Multi Perception Neural Network (MLPNN), Logistic Regression (LR), Support Vector Machine (SVM), Tree Bagger Random Forest, Grid Search (GS), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The steel plates faults dataset used in the study is taken from the University of California at Irvine (UCI) machine learning repository. As a result, the proposed steel plate faults diagnosis system based on S-MTS shows 90.79% of classification accuracy. The accuracy of the proposed diagnosis system is 6-27% higher than MLPNN, LR, GS, GA and PSO. Based on the fact that the accuracy of commercial systems is only about 75-80%, it means that the proposed system has enough classification performance to be applied in the industry. In addition, the proposed system can reduce the number of measurement sensors that are installed in the fields because of variable optimization process. These results show that the proposed system not only can have a good ability on the steel plate faults diagnosis but also reduce operation and maintenance cost. For our future work, it will be applied in the fields to validate actual effectiveness of the proposed system and plan to improve the accuracy based on the results.

FABRICATION OF MYOMUCOSAL FLAP USING CULTURED ORAL EPITHELIUM IN RABBIT MODEL (가토모델에서 배양 구강상피를 이용한 근-점막 피판의 형성에 관한 연구)

  • Shin, Young-Min;Chung, Hun-Jong;Ahn, Kang-Min;Park, Hee-Jung;Sung, Mi-Ae;Kim, Soung-Min;Hwang, Soon-Jung;Kim, Myung-Jin;Jahng, Jeong-Won;Kim, Sung-Po;Yang, Eun-Kyung;Song, Kye-Yong;Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.3
    • /
    • pp.226-237
    • /
    • 2005
  • Purpose : Extensive defect of oral and maxillofacial area is usually reconstructed with composite flap including skin paddle. However, if the defects are lined with only skin components, the mucosa's role in mastication and texture are not restored. Furthermore, stiffness and hair-growing prevent denture rehabilitation and good oral hygiene. This study was performed to overcome the disadvantages of composite soft tissue flaps including the skin and to make a model for myo-mucosal flaps. Materials and methods : Buccal mucosa sized $0.5\times1.0\;cm^2$ from New Zealand rabbit (around 1.5kg) was harvested and cultivated by the modification of Rheinwald and Green's keratinocyte culture method. Cultured mucosa was grafted on the fascia of latismus dorsi as form of mucosal sheet. After 7, 10, 14 days, the myomucosal flap was excised and evaluated under light microscope with H & E and immunohistochemical staining. As control group, harvested buccal mucosa from rabbit was transplanted to gracilis muscle(n=6). Results : From 7 days after prelamination, the basal layer of the grafted mucosa resembled that of normal mucosa. As control group, transplanted mucosa had original shape but there's slight inflammatory reaction. Prelaminated mucosa has 19.8$\pm$4.59 cell layers and some samples have more than 20 layers. The expression rate of PCNA was relatively strong (42.9%$\pm$14.1) at the basal layer of grafted mucosa and the laminin was found at the basal layer. On the contrary, prelaminated mucosa at 10 days showed moderate expression rate of PCNA(32.4%$\pm$4.62). We found the mucosal layer was somehow disappeared and there is strong inflammatory reaction. After 14 days prelamination, the grafted oral keratinocytes were almost disappeared and expression of PCNA was not observed. Conclusion : We can make 75 fold large mucosal($3850mm^2$) sheet from small samples of mucosa $(50mm^2)$. Epithelial sheet that grafted on the fascia of muscle underwent differentiation and proliferation. But after 10, 14 days, there was strong inflammatory reaction and the grafted mucosa was destroyed from surface layer. In rabbit model, transfer of fascio-mucosal flap should be done from 7 to 10 days after prelamination.

Direct Bonding of Si(100)/NiSi/Si(100) Wafer Pairs Using Nickel Silicides with Silicidation Temperature (열처리 온도에 따른 니켈실리사이드 실리콘 기판쌍의 직접접합)

  • Song, O-Seong;An, Yeong-Suk;Lee, Yeong-Min;Yang, Cheol-Ung
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.556-561
    • /
    • 2001
  • We prepared a new a SOS(silicon-on-silicide) wafer pair which is consisted of Si(100)/1000$\AA$-NiSi Si (100) layers. SOS can be employed in MEMS(micro- electronic-mechanical system) application due to low resistance of the NiSi layer. A thermally evaporated $1000\AA$-thick Ni/Si wafer and a clean Si wafer were pre-mated in the class 100 clean room, then annealed at $300~900^{\circ}C$ for 15hrs to induce silicidation reaction. SOS wafer pairs were investigated by a IR camera to measure bonded area and probed by a SEM(scanning electron microscope) and TEM(transmission electron microscope) to observe cross-sectional view of Si/NiSi. IR camera observation showed that the annealed SOS wafer pairs have over 52% bonded area in all temperature region except silicidation phase transition temperature. By probing cross-sectional view with SEM of magnification of 30,000, we found that $1000\AA$-thick uniform NiSi layer was formed at the center area of bonded wafers without void defects. However we observed debonded area at the edge area of wafers. Through TEM observation, we found that $10-20\AA$ thick amourphous layer formed between Si surface and NiSix near the counter part of SOS. This layer may be an oxide layer and lead to degradation of bonding. At the edge area of wafers, that amorphous layer was formed even to thickness of $1500\AA$ during annealing. Therefore, to increase bonding area of Si NiSi ∥ Si wafer pairs, we may lessen the amorphous layers.

  • PDF

Periodontal Response According to the Timing of Orthodontic Force Application alter Bone Graft into Angular Bony Defect in the Dog (성견에서 수직적 골결손부에 골이식후 교정력 적용시기에 따른 치주조직의 반응)

  • Lee, Sang-Yeol;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.369-379
    • /
    • 2001
  • The aim of this study was to investigate the periodontal response according to the timing of orthodontic force application after bone graft into the angular bony defect. Nine dogs were divided into three groups, 2, 4, and 6 weeks, according to the timing of orthodontic force application after bone graft. Periodontal angular bony defects were created surgically at the distal aspect of both maxillary third incisors. Two weeks later, flap operation was performed to eliminate inflammation and reference notch was made on the root surface at the level of the bottom of each defect. Demineralized freeze-dried bone was implanted on the left side whereas only debridement was done on the other side. Experimental tooth movement was executed during 8 weeks on both graft and non-graft sides. After 2 weeks of retention period, animals were sacrificed for histologic specimens. The results were obtained as follows 1 New bone formation was more pronounced in the graft side than in the non-grad side in all experimental animals. 2. In the 6-week group, new bone and cementum formation was observed in more than half from the notch to the cemento-enamel junction, and the zone of connective tissue attachment was found without apical migration of junctional epithelium. 3. In the 4-week group, the amount of new bone formation was smaller than in the 6-week group whereas the overall remodeling pattern was similar. 4. New bone formation was confined to around the notch and the junctional epithelium migrated apically to the level of the notch with no connective tissue attachment and cementum formation in the 2-week group. The results of the present study suggest that periodontal response may be influenced by the timing of orthodontic force application after bone graft into angular bony defect.

  • PDF

Electrochemical Characteristic on Hydrogen Intercalation into the Interface between Electrolyte of the 0.1N H2SO4and Amorphous Tungsten Oxides Thin Film Fabricated by Sol-Gel Method (졸-겔법으로 제조된 비정질의 텅스텐 산화물 박막과 황산 전해질 계면에서 일어나는 수소의 층간 반응에 대한 전기화학적 특성)

  • Kang, Tae-Hyuk;Min, Byoung-Chul;Ju, Jeh-Beck;Sohn, Tae-Won;Cho, Won-Il
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1078-1086
    • /
    • 1996
  • The peroxo-polytungstic acid was formed by the direct reaction of tungsten powder with the hydrogen peroxide solution. Peroxo-polytungstic powder were prepared by rotary evaporator using the fabricated on to ITO coated glass as substrate by dip-coating method using $2g/10mL(W-IPA/H_2O)$ sol solution. A substrate was dipped into the sol solution and after a meniscus had settled, the substrate was withdrawn at a constant rate of the 3mm/sec. Thicker layer could be built up by repeated dipping/post-treatment 15 times cycles. The layers dried at the temperature of $65{\sim}70^{\circ}C$ during the withdrawn process, and then tungsten oxides thin film was formed by final heating treatment at the temperature of $230{\sim}240^{\circ}C$ for 30min. A linear rotation between the thickness of thin film and the number of dipping/post-treatment cycles for tungsten oxides thin films made by dip-coating was found. The thickness of thin film had $60{\AA}$ after one dipping. From the patterns of XRD, the structure of tungsten oxides thin film identified as amorphous one and from the photographs of SEM, the defects and the moderate cracks were observed on the tungsten oxides thin film, but the homogeneous surface of thin films were mostly appeared. The electrochemical characteristic of the $ITO/WO_3$ thin film electrode were confirmed by the cyclic voltammetry and the cathodic Tafel polaization method. The coloring bleaching processes were clearly repeated up to several hundreds cycles by multiple cyclic voltammetry, but the dissolved phenomenon of thin film revealed in $H_2SO_4$ solution was observed due to the decrease of the current densities. The diffusion coefficient was calculated from irreversible Randles-Sevick equation from the data obtained by the cyclic voltammetry with various scan rates.

  • PDF