• Title/Summary/Keyword: Surface Current

Search Result 5,713, Processing Time 0.038 seconds

Rip Current Sensitive Analysis Using Rose Diagram for Wave-Induced Current Vectors at Haeundae Beach, Korea (해빈류 벡터 장미도를 통한 해운대 해수욕장의 이안류 민감도 분석)

  • Kim, Dong Hee;Lee, Sahong;Lee, Jung Lyul
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.320-326
    • /
    • 2016
  • Rip current forecasts, based on intensity, are marked in four levels—notice, watch, warning, and danger. However, numerical results are represented by current vectors, whose magnitudes are then converted into predictive levels. In the present study, the rose diagram is adapted as a determinative forecasting index and examined for the case of an ideal rip channel consisting of surface, bottom, and averaged currents. Further, it is employed in the sensitivity analysis of wave-induced currents generated by wave conditions at the Haeundae Beach. The simulation of surface onshore and bottom undertow currents is accomplished by including a mass flux term in the wave-averaged continuity equation.

PEO Film Formation Behavior of AZ31 Mg Alloy under Pulse Current (펄스 전류 하에서 AZ31 마그네슘 합금의 플라즈마전해산화 피막의 형성 거동)

  • Moon, Sungmo
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.5
    • /
    • pp.292-298
    • /
    • 2022
  • In this study, PEO (plasma electrolytic oxidation) film formation behavior of AZ31 Mg alloy under application of 300 Hz pulse current was studied by the analyses of V-t curve, arc generation behavior, PEO film thickness and morphology of PEO films with treatment time in 0.05 M NaOH + 0.05 M Na2SiO3 + 0.1 M NaF solution. PEO films was observed to grow after 10 s of application of pulse current together with generation of micro-arcs. PEO film grew linearly with treatment time at a growth rate of about 5.58 ㎛/min at 200 mA/cm2 of pulse current but increasing rate of film formation voltage became lowered largely with increasing treatment time after passing about 250 V, suggesting that resistivity of PEO films during micro-arc generation decreases with increasing film formation voltage at more than 250 V.

Die Sinking Electrical Discharge Machining of SiC/AI Metal Matix Composite (탄화규소/알루미늄 금속계 복합재료의 형상방전가공)

  • 왕덕현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.34-40
    • /
    • 1998
  • Conductive metal matrix composite(MMC) material of 30% silicon carbide particulated based on aluminum matrix was machined by die sinking electrical discharge machining(EDM) process according to different current and duty factor for reverse polarity of electrode. Material removal rate(MRR) was examined by process under various operation conditions. The surface morphology was evaluated by surface roughness parameter and scanning electron microscopy(SEM) research. The MRR was suddenly increased over 11 ampere of current, and it was slightly changed over 0.3 of duty factor. The maximum surface roughness of EDMed surface was affected by the duty factor. The SEM photograghs of EDMed surface showed wide recast distribution region of melting materials as increased of current and duty factor.

  • PDF

Photon-induced surface conductivity measurement of MgO in an AC PDP

  • Ha, Chang-Hoon;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.130-133
    • /
    • 2006
  • In order to study the relationship between the discharge characteristics of an ac PDP and the surface conductivity of MgO thin film, the surface current across a ring shaped MgO film was measured by exposure to monochromatic vacuum ultraviolet from the synchrotron radiation source whose wavelength ranges from 60nm to 240nm $(5.5eV{\sim}25eV)$. The experimental results show that the surface current begins to increase rapidly at the photon energy of about 9 eV which might correspond to the valence band edge of MgO. The difference in the surface current level correlate well with the differences in the preparation method of MgO films and their respective discharge characteristics such as the firing, minimum sustain voltages, address voltage margin and address discharge delay time.

  • PDF

A STUDY ON COPPER DEPOSITION PROCESS DURING ANODIC OXIDATION OF ALUMINIUM ALLOY

  • Koh, I.S.;Han, S.H.;Shin, D.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.444-446
    • /
    • 1999
  • The structure and composition of anodic films, formed on 6063 commercial aluminium alloy at constant current density of $1.5A/^dm2$ with various superimposed cathodic current ratio, in the range 0~33%, in the 11% $H_2SO_4$ with various concentration of $CuSO_4{\cdot}5H_2O$, in the range 0~75 g/l, without cathodic current are generally porous-type and no sign of Cu co-deposition appearance, suggesting that cathodic current is an important factor in the Cu co-deposition. Comparison with the anodic film thickness measurement results obtained from anodic film formed by direct anodic current and anodic film formed by superimposed various portion of cathodic current, the portion of cathodic current of input current increases with decrease of anodic film thickness and increases with increase of concentration of $Cu_2S{\;}and{\;}Cu_2O$ in the anodic film.

  • PDF

A Study of the Characteristics on the Vacuum Interrupter with Axial Magnetic Field Type using 3 Dimension Finite Element Analysis (3차원 유한요소해석을 이용한 종자게형 진공 인터럽터의 특성고찰)

  • 하덕용;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.460-467
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density on the vacuum interrupter with axial magnetic field type using 3 dimension finite element analysis. An axial magnetic field parallel to the current flow in the arc column can improve the current breaking capacity of vacuum interrupter by affecting the arc mode. The axial magnetic flux density on the contact electrode surface is analyzed by inputting external current as a function of the transient time for sine half wave. And it also is analyzed within the gap distance of the contact electrode. The peak value of current but is decreased with the descending current on the contact electrode surface and within the gap distance of the contact electrode. The residual magnetic field is generated on the contact electrode surface and within the gap distance in the instant of zero current, which is due to the influence of eddy currents. The phase shift due to eddy currents, defined as time difference between the maximum value of current and axial magnetic field, is about 1ms in the center point of gap distance.

The Accident Hazards and Properties of the Surface Leakage Current on the Polymer Insulation caused by Salt-water and Dust (염수 및 분진에 의한 고분자 절연물의 표면누설전류 특성과 사고 위험성)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.129-135
    • /
    • 2007
  • It is necessary to study on the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. Therefore, we measured surface leakage current and surface variation of insulation material due to the dust and salt-water. From the results, the surface of bakelite is bad effect for salt-water than other material. The surface leakage current increases by repeated salt-water pollution and the surface of material is carbonized with arc occurrence. Also, it is need to variation of surface coating and shape of material to repress a leakage current on electrical material.

Activity Coefficients and Coulombic Correction Factor for Surface Complexation Modeling

  • Rhee, In-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.146-155
    • /
    • 2002
  • Surface complexation models employ mass law equations to describe the reaction of surface functional groups with ions in the solution and also Gouy-Chapman theory to consider the electrostatic effects in the surface reactions. In current surface complexation models, however, the coulombic factors used are not wholly consistent with the Gouy-Chapman model of the surface. This study was to provide the derivation of the coulombic term usually employed and then a revised coulombic term completely consistent with Gouy-Chapman Theory. The electrical potential energy. zF${\psi}$, in current surface complexation models is not consistent with the Gouy-Chapman theory with the potential gradient close to the charged surface but with the Donnan model with the uniform potential. Even though the new coulombic factor yielded lower surface potential, it provided worse fits for acid-base titration data of the goethite suspensions.

  • PDF

Reduction of Leakage current Generated by Degradation in Organic Thin Film Transistors using Pattern on Pentacene Surface by Atomic Force Microscope

  • Hwang, Hyun-Doo;Kim, Hyun-Suck;Kim, Chang-Ho;Kim, Jae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.560-562
    • /
    • 2009
  • In this paper, we proposed a simple method of decreasing the off current generated by degradation for improve the electrical characteristics such as mobility and on/off current ratio by making the line patterns on the pentacene surface between the electrodes using atomic force microscope (AFM) lithography.

  • PDF

Surface Aging Properties of Silicon Rubber Insulator by salt-fog (Silicon rubber 애자의 salt-fog 표면열화 특성)

  • 이종찬;이운용;조한구;박대희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF