• Title/Summary/Keyword: Support fixtures

검색결과 23건 처리시간 0.019초

Analysis of the University Library's Space Program and Design Characteristics with the Concept of 'Cultural Commons' - Focused on the Tama Art University Library - (문화공유지(Cultural Commons) 개념에 의한 대학도서관의 공간프로그램과 디자인방법의 특성 - 타마미술대학 도서관을 중심으로 -)

  • Pyun, Young-Hee;Park, Chan-Il
    • Korean Institute of Interior Design Journal
    • /
    • 제24권3호
    • /
    • pp.48-58
    • /
    • 2015
  • This study is to conclude a direction for Information Commons, which supports the university library in a new role. The study explains perspectives on the changing role of the university library by examining the approaches, histories, and theories practiced by various researchers on Information Commons. The study aims to discover ways of improving the library space that are dedicated to technology using Information Commons, it also examines ways of creating a unified "library space" that will support learning and access to knowledge and information. The features of Cultural Commons include making improvements to technology-centered space, and providing support to research, freedom of speech, creative approach, public freedom and collaboration, and interaction. The functions of Cultural Commons within the university library are listed: First, it supports programs that will transform the library into a social hub within the university. The space specifically blurs the boundary between the library building and its surroundings, and unifies these spaces to enhance its catalytic role in aiding social interactions and human-centered approach. Second, it supports active participation through cultural programs and provides a fluid and interactive space with virtual resources. Third, it enhances user experience to supports behaviors and activities that involve fixtures and equipment in the space to promote learning. The study notes that, with the emergence of these characteristics, the university library is changing by implementing Cultural Commons for on-campus social space and new learning. Accordingly, this implementation is expected to enhance active acceptance of the library space in the future.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE (하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제37권5호
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

The Digital Mock-Up Information System for New Car Development

  • Min, Sung-Ki;Lee, Chul-Woo
    • Proceedings of the CALSEC Conference
    • /
    • 한국전자거래학회 1999년도 학술대회지 vol.1
    • /
    • pp.277-299
    • /
    • 1999
  • Since Chrysler Motor Co. had experienced the digital development system in the beginning of 1990's, most of leading automobile companies are trying to apply a digital information system for their own business process reengineering based upon concurrent engineering system from product planning phase. This is called as virtual DMU(Digital Mock-Up) system instead of the traditional PMU(Physical Mock-Up) system. By using the virtual prototype, all of the design requirements and system specifications can be checked, changed and optimized more quickly and more efficiently. This paper consists of five chapters for the DMU information system. In the 1$^{st}$ chapter, the principle of digital design system is suggested by using four basic modules such as product design module, process design module, manufacturing system design module and central control module. The basic scheme of DMU is introduced with the benefits of application in the chapter 2. In the chapter 3, a digital design process of new car development is explained with the detailed DMU design and design review processes. In the chapter 4, the practical DMU manufacturing techniques and applications are introduced as CAD/CAM analyses, DPA(Digital Pre-Assembly)reviews for development, production, operation and maintenance phases, digital tolerance analyses and digital factory analyses for assembling line simulation, automated robot welding processes, production jig & fixtures and painting process simulation. Finally, the activities of digital design support; CAS-styling, CAE-engineering and CAT-testing are summarized for design optimization in the chapter 5. As today's automobile manufactures and related business organizations are struggling to compete in the global marketplace, they are concentrating on efficient use of DMU information system to reduce the new car development cost, to have shorten the delivery schedule and to improve product design quality. To meet the demand of those automobile industries on digital information systems, the CALS(Computer aided Acquisition and Logistics Support) and EC(Electronic Commerce)initiative has been focused as a dominant philosophy in defense & commercial industries, specially automobile industries.s.

  • PDF

The Development of a Dormitory Management System Using the Ubiquitous and Automation Technology (유비쿼터스와 자동화 기술을 이용한 기숙사 관리 시스템 개발)

  • Jang, Jae-Hyuk;Sim, Gab-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2009
  • Today the use of RFID is extended in medical. circulation market, manufacture, security field, etc. Besides, the book-lending and the attendance management system are on an increasing trend in the use of RFID The developed dormitory management system is composed of a support program, a room management program, a manager program, and a mobile program etc.. In the support program a student(or a manager) can see his(or all member's) entrance and exit history. The room management program decides whether a student can enter the dormitory or not and manages the use of the power after or inquiring a RFID's input tag information into database server. The manager program is able to input and modify a room state and the fixtures information in the room required to operate the room management program, to set up and retrieve a student's entrance and exit information and a room state information. The mobile program enables a manager to check student's identity whether he is in or out, and the manager can know the personal information of being out in detail.

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS (수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구)

  • Yu Seong-Hyun;Park Won-Hee;Park Ju-Jin;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제44권2호
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제53권1호
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.

Rehabilitation of maxillary partial edentulous patients using implant assisted removable partial denture (상악 소수치 잔존 환자에서 임플란트를 이용한 가철성 부분틀니 수복 증례)

  • Lee, Bo-Ra;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제52권2호
    • /
    • pp.128-135
    • /
    • 2014
  • Treatment options for partially edentulous patients are fixed partial denture, removable partial denture and implant supported fixed partial denture. In case of a patient with a few remaining teeth, removable partial denture and implant supported fixed prosthesis are available. For implant fixed prothesis, enough implant fixtures are required and the patient's general condition, local factors and economic status must be considered. When the condition of the abutments and the residual ridge is favorable and the prosthesis is well designed, removable partial denture can be an option. In removable partial denture, the bilateral support is important. If the teeth remain unilateral, harmful stress is put on the abutments by the fulcrum line. In this situation, strategic implantation and implant-retained or assisted removable partial denture is beneficial to the retention and support of the denture. And this can be cost-effective, functional and esthetic choice of treatment. This article describes the prosthodontic rehabilitation of Maxillary Kennedy class I partially edentulous patients. In these two cases, the patients had a small number of teeth and they were restored by the combination of a removable partial denture and dental implants.

A BIOLOGIC STUDY ON TOOTHASH - PLASTER OF PARIS MIXTURE WITH ABSORBABLE COLLAGEN MEMBRANE IN THE TREATMENT OF PERI-IMPLANT DEFECTS (임플란트 주위염 치료시 치아회분말과 치과용 연석고의 혼합 매식의 골재생 효과)

  • Choi, Hee-Yeon;Kim, Hak-Kyun;Kim, Su-Gwan;Moon, Seong-Yong;Kim, Sang-Yeol;Park, Kwang-Bum;Kim, Young-Min;Lim, Seong-Chul;Kim, Eun-Seok;Lee, Jeong-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권2호
    • /
    • pp.142-149
    • /
    • 2008
  • The purpose of this study was to evaluate histomorphometrically a toothash - plaster of Paris mixture associated with collagen membrane ($Bio-Gide^{(R)}$), regarding new bone formation in the peri-implantitis defects in dogs. Three mandibular molars were removed from 1-year-old mongrel dogs. After 2 months of healing, 2 titanium implants with sandblasted with large grit and acid etched (SLA) surface were installed in each side of the mandible. Experimental peri-implantitis was induced with ligatures after successful osseointegration. Ligatures were removed after identification of bone defect beneath the level of 5th thread of fixture on radiographic image. The mucoperiosteal flaps were elevated and the contaminated fixtures were treated with chlorhexidine and saline. The bone defects were assigned to one of the following treatments: no guided bone regeneration (GBR) procedure (group 1), GBR with Bio-$Oss^{(R)}$ and Bio-$Gide^{(R)}$ (group 2), or GBR with toothash - plaster of Paris mixture (TPM) and Bio-$Gide^{(R)}$ (group 3). The dogs were sacrificed after 8 or 16 months. The mean percentages of new bone formation within the limits of the 5 most coronal threads were $17.83{\pm}10.69$ (8 weeks) and $20.13{\pm}13.65$ (16 weeks) in group 1, $34.25{\pm}13.32$ (8 weeks) and $36.33{\pm}14.21$ (16 weeks) in group 2, and $46.33{\pm}18.39$ (8 weeks) and $48.00{\pm}17.78$ (16 weeks) in group 3, respectively. The present study confirmed statistically considerable new bone formation within the threads in group 3 compared with group 1 at 8 and 16 weeks (P<0.05). Although, data analysis did not reveal significant differences between group 2 and 3, the latter showed better results during the period of 8 or 16 weeks. Our findings support the effectiveness of TPM as a GBR material in the treatment of peri-implantitis bone defect.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제43권1호
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.