• Title/Summary/Keyword: Supply angle

Search Result 207, Processing Time 0.031 seconds

The design of a torque controller for single phase induction motor using phase angle (위상각제어에 의한 단상유도전동기의 토크제어기설계)

  • Lim, Y.C.;Choi, C.H.;Na, S.H.;Jung, Y.G.;Chang, H.C.;Chang, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.908-911
    • /
    • 1993
  • The single-Phase induction motor is widely used in many light duty applications. especially in home and the office. At present, many applications which use these motor require continuously adjustable speed control. In the general, the speed control of single-phase induction motor is accomplished at a few discrete speeds by using tapped-windings, pole switching or gear. These techniques is inefficient and complicated. In this paper, auxiliary winding voltage phase angle of single-phase induction motor is used to continuously adjust electromagnetic torque. The analysis includes the determination of the relationship between the auauxiliary winding voltage phase angle and torque. Simulation results of the motor's torque-speed characteristics using the controlled auxiliary winding supply are shown and discussed. The drive is tested using a dynamometer to experimentally verify the results of the theory and simulations.

  • PDF

A Study on the Diagnosis Method considering Harmonics Flow (유입, 유출에 따른 고조파 전류 해석 방법 연구)

  • Jung, Hae-Sung;You, Sang-Bong;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1461-1462
    • /
    • 2015
  • Based on the Kepco's standard supply terms, the customer should pay for installation the regulating device or protective device which are granted by Kepco in case the customer hinder other customer's electricity usage or it may cause the interruption because of harmonics or waveform distortion. It is necessary to consider the phase angle of voltage, current for harmonics so we can set up the measure of harmonic damages.

  • PDF

Analysis of symmetrical three-phase induction motor fed by phase angle controlled sources

  • Abdul-baki, E.M.;Lazim, M.T.;Naser, M.Sh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.1028-1034
    • /
    • 1989
  • A method of analysis of the steady-state performance of induction motor with supply voltage controlled by cyclically-triggered inline thyristors is presented. Phase-variable model and asymmetrical components are not used in this analysis. Instead, Fast Fourier Transform technique and the method of multiple reference frames are employed to obtain the constant-speed performance of I.M. easily.

  • PDF

The Graft Polymerization of Acrylic Acid in Vapour Phase onto Poly(ethylene terephthalate) by Cold Plasma Part (I) (저온 Plasma를 이용한 Poly(ethylene terephthalate)에의 Acrylic Acid의 기상 Graft 공중합 반응(I))

  • 천태일;최석철;모상영
    • Textile Coloration and Finishing
    • /
    • v.1 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • The distinguishing characteristic of the glow discharge is that chemical reaction induced by partially ionized gases are limited only to the substrate surface. Most studies have been done on the plasma etching and polymerization. The graft polymerization in vapour phase by cold plasma has been rarely investigated. In this study the system of tub3ar reaction chamber with capacitively coupled electrode of alternative current of 60 Hz was employed for the graft polymerization. The graft polymerization of Acylic Acid(AA) onto the poly (ethylene terephthalate) (PET) was carried out by treatment of PET film and fabric by cold plasma (glow discharge of argon gas), followed by the supply of AA vapour. The graft yield was about 1 wt%. The surface property was determined by contact angle, the surface tension was evaluated by zisman’s plot and equation of surface tension mesurement. The results were as follows: 1. In order to obtain lower contact angle, it was effective to avoid the vicinity of electrodes for a setting position of substrate. 2. Contact angle affected on the monomer pressure and its duration of exposure to the acid vapour. 3. Polymer radical formation was influenced by the changes of the value of current density and plasma treatment time. 4. Total surface tension of plasma grafted PET film increased. With an increase in the carboxylic acid content, the dispersion force decreased, while, the polar force and hydrogen bonding force increased. 5. The contact angle decreased from $75^\circ$ to around $30^\circ$ by plasma grafting. There was no ageing effect on the contact angle after 4 months.

  • PDF

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Design and Implementation of Dermatology $CO_2$ Laser System (피부과용 $CO_2$레이저시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.2
    • /
    • pp.8-13
    • /
    • 2001
  • We demonstrate a pulsed CO$_2$laser with long pulse duration of millisecond order in the low pressure less than 30 Torr. A new power supply for our laser system switches the voltage of AC power line(60㎐) directly. The power supply doesn't need elements such as a rectified bridge, energy-storage capacitors. and a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60㎐ and the firing angle of SCR gate is varied from 30˚ to 150˚. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of SCR precisely. The maximum laser output is 23W at the total pressure of 18 Torr, the pulse repetition rate of 60㎐, and SCR gate firing angle of 90˚. In addition, the obtained laser pulse width is approximately 3㎳(FWHM)

Structural and Electrical Properties of $CuGaS_2$ Thin Films ($CuGaS_2$ 반도체 박막의 구조적 및 전기적 특성)

  • Park, Gye-Choon;Jung, Hae-Duk;Lee, Jin;Jeong, Woon-Jo;Kim, Jong-Uk;Cho, Young-Dae;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.286-289
    • /
    • 2001
  • Single phase CuGaS$_2$ thin film with the highest diffraction peak of (112) at diffraction angle (2$\theta$) of 28.8$^{\circ}$ was made at substrate temperature of 7$0^{\circ}C$, annealing temperature of 35$0^{\circ}C$ and annealing time of 60 min. And second highest (204) peak was shown at diffraction angle (2$\theta$) of 49.1$^{\circ}$. Lattice constant of a and c of that CuGaS$_2$ thin film was 5.37 $\AA$ and 10.54 $\AA$ respectively. The greatest grain size of the thin film was about 1${\mu}{\textrm}{m}$. The (112) peak of single phase of CuGaS$_2$ thin film at annealing temperature of 35$0^{\circ}C$ with excess S supply was appeared with a little higher about 10 % than that of no exces S supply And the resistivity, mobility and hole density at room temperature of p-type CuGaS$_2$ thin film with best crystalline was 1.4 $\Omega$cm, 15 cm2/V . sec and 2.9$\times$10$^{17}$ cm$^{-3}$ respectively. It was known that carrier concentration had considerable effect than mobility on variety of resistivity of the fabricated CuGaS$_2$ thin film, and the polycrystalline CuGaS$_2$ thin films were made at these conditions were all p-type.

  • PDF

A Study of Micro Stencil Printing based on Solution Atomization Process (용액 미립화공정 기반의 마이크로 스텐실 프린팅에 관한 연구)

  • Dang, Hyun Woo;Kim, Hyung Chan;Ko, Jeong Beom;Yang, Young Jin;Yang, Bong Su;Choi, Kyung Hyun;Doh, Yang Hoi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.6
    • /
    • pp.483-489
    • /
    • 2014
  • In this study, experiments were conducted for micro pattern printing to combine solution atomization process and stencil printing based on electrospray deposition. The stencil mask fabricated by etching the photosensitive glass placed below 0.3 mm distance to substrate has 100 um line width. The process parameters of electrospray deposition system for the atomization of the solution are applied voltage and supply flow rate of the solution. Meniscus angle of cone-jet was optimized by varying the supply flow rate from 0.3 ml/hr to 0.7 ml/hr. Voltage condition was verified having symmetric cone-jet angle and no pulsation at 8.5 kV applied voltage. In addition, a number of micro patterns are printed using a single 1 step process by solution atomization process. Variable line width of approximate 100 um was confirmed by changing conditions of solution atomization regardless of the pattern size of stencil mask.

Wireless Energy Supply for a MAV Propulsion System

  • Shimane, Eri;Komatsu, Shuhei;Komaru, Takashi;Komurasaki, Kimiya;Arakawa, Yoshihiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.862-865
    • /
    • 2008
  • Wireless energy supply for an MAV propulsion system using microwave was developed. This system consists of three sub system; the transmitter system, the rectenna system, and the tracking system. In the transmitter system five horn antennas were used as the antenna elements for the phased array system and both the beam divergence and steering angle was about 9deg. Eight rectennas were arrayed in parallel to obtain enough power to drive the electric motor on the MAV(the voltage was 250mV and the current was 6.8mA) in rectenna system. In tracking system two units of antenna system with leaf pattern which received the linearly-polarized wave despite the MAV yaw angle were set in each axis(x, y) for tracking an MAV in a 2-Dimentional space. And three output voltages $V_{com},\;V_1$ and $V_2$ were loaded in the PC to detect if the distance between transmitter and receiver was not constant. Finally when the microwave beam was steered by the phased array system the output voltage from rectenna was measured at 62cm while the MAV circled around above the transmitter system.

  • PDF

Effect of Nipple Angle on Water Disappearance by Pigs

  • Yun, M.S.;Ju, W.S.;Piao, L.G.;Long, H.F.;Kil, D.Y.;Oh, H.K.;Kim, Y.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.1
    • /
    • pp.120-123
    • /
    • 2008
  • This experiment was conducted to investigate the effect of different nipple angles on water disappearance in growing pigs, which is defined as the water which leaves the watering device but is not consumed by the pig. This water adds to the volume of the total waste slurry. Four crossbred pigs averaging $70.0{\pm}1.4$ kg were assigned into 1 of 4 treatments using a $4{\times}4$ Latin-square design. Treatments were distinguished by the angle between nipple terminal and the perpendicular wall. These angles were: 1) NA-30 (= Nipple Angle $30^{\circ}$), 2) NA-45 (= Nipple Angle $45^{\circ}$), 3) NA-60 (= Nipple Angle $60^{\circ}$) and 4) NA-90 (= Nipple Angle $90^{\circ}$). All of the nipples were fixed at shoulder height of each pig. After a 7-day adaptation period, samples were collected from each pig for 4 days, followed by a day for change-over. Pigs were fed a 0.8 kg diet twice daily at 08:00 and 20:00 and supplied water ad libitum. Throughout the experimental period, pigs in the NA-30 treatment group showed greater water disappearance than other treatments. Water disappearance was the lowest for the NA-60 treatment group (p<0.01). The percentage of water disappearance to the water supply was significantly reduced in the NA-60 treatment group (p<0.01). Water intake was the same for all the treatment groups. The rate of water disappearance per unit of water intake was significantly decreased in pigs in the NA-60 treatment group compared to other groups (p<0.01). These results suggested that the nipple angle for growing pigs should be $60^{\circ}$ to reduce water disappearance and, subsequently, the amount of waste generated.