• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.028 seconds

Radical Mist Generator Using a Water Plasma Jet and Its Sterilization Effect

  • Huh, Jin Young;Ma, Suk Hwal;Kim, Kangil;Choi, Eun Ha;Hong, Yong Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.175.1-175.1
    • /
    • 2016
  • In recent, tract infections such as atopic dermatitis, allergic rhinitis and a respiratory disease are increasing, giving rise to the atmospheric pollution, inflow of micro-size dust and side effect of humidifier disinfectant. In this context, the environment-friendly technology is required to eliminate airborne pathogens. We propose solution of the previous problems, making use of Radical Mist Generator (RMG). Existing technologies of air purification using a gas discharge produce harmful substances such as ozone, NOx, etc. However, the RMG uses a pure water as a plasma forming material. The RMG sprays the water mist, which contains reactive radicals to sterilize microorganisms. RMG is comprised of a power supply, plasma electrodes and a nozzle. In order to analyze the electrical characteristic and concentrations of reactive radicals, we employ an oscilloscope and a titration method. To test the sterilization effect of RMG, we used E.coli. We confirmed that E.coli was killed over 90%. Eventually, we expect that RMG can be promising tool for a purified system.

  • PDF

Oxidative Stress in Rice (Oryza sativa L.) Seedlings Induced by Flooding

  • Lee, Keun Pyo;Jung, Jin
    • Journal of Applied Biological Chemistry
    • /
    • v.44 no.4
    • /
    • pp.159-162
    • /
    • 2001
  • Plant stress incurred by flooding was studied in terms of oxidative stress, using greened rice seedlings subjected to a complete submergence followed by re-exposure to air under illumination ($30W/m^2$). It appeared that shoot tissues of the seedlings suffered oxygen deficiency during the flooding treatment, pertinent to the general concept. Interestingly enough, however, membrane peroxidation in shoots was enhanced by the submergence, as assessed by the content of 2-thiobarbituric acid-reactive substances (TBARS), and the re-aeration resulted in a rapid reduction of TBARS content. Such pattern of response was also seen in the change in the steady state level of $H_2O_2$. In contrast, superoxide dismutase and glutathione reductase that are involved in the detoxifying processes of superoxide in plant cells were significantly activated only during the re-aeration. These results allowed us to suggest the followings as a working hypothesis. Photorespiration-linked production of $H_2O_2$ may largely contribute to the increase in $H_2O_2$ level as well as TBARS production in shoots during the submergence. An abrupt re-supply of $CO_2$ by the re-aeration brings the photosynthetic apparatus back to full operation, suppressing photorespiration and probably causing a momentary, excess formation of superoxide and its dismutation product through side reaction, which gives rise to activating substrate-inducible antioxidative enzymes.

  • PDF

Modeling and Characterization of Low Voltage Access Network for Narrowband Powerline Communications

  • Masood, Bilal;Haider, Arsalan;Baig, Sobia
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.443-450
    • /
    • 2017
  • Nowadays, Power Line Communication (PLC) is gaining high attention from industry and electric supply companies for the services like demand response, demand side management and Advanced Metering Infrastructure (AMI). The reliable services to consumers using PLC can be provided by utilizing an efficient PLC channel for which sophisticated channel modeling is very important. This paper presents characterization of a Low Voltage (LV) access network for Narrowband Power Line Communications (NB-PLC) using transmission line (TL) theory and a Simulink model. The TL theory analysis not only includes the constant parameters but frequency selectivity is also introduced in these parameters such as resistance, conductance and impedances. However, the proposed Simulink channel model offers an analysis and characterization of capacitive coupler, network impedance and channel transfer function for NB-PLC. Analysis of analytical and simulated results shows a close agreement of the channel transfer function. In the absence of a standardized NBPLC channel model, this research work can prove significant in improving the efficiency and accuracy of NB-PLC communication transceivers for Smart Grid communications.

A Numerical Analysis of the Distribution of Temperature and Combustio Products I case of Compartment Fire (폐쇄공간 화재 발생시 온도 및 연소산화물의 분포에 관한 모델 해석)

  • 차형석;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.1
    • /
    • pp.8-16
    • /
    • 1998
  • The first purpose of this study is to verify the application of computer modelling to a enclosed space fire. The second one is to determine temperature distribution for the three different ventilation types in case of a enclosed space fire. The third one is to find out the ventilation direction and ventilation quantity to remove effectively heat and combustion products generated by a fire in variable air volume(VAV) system. Firstly, compared with experimental results of Lawrence Livermore National Laboratory(LLNL), numerical results show good agreements. Secondly, among three different ventilation types, the numerical analyses show the highest temperature distribution in occupied zone(up to 1.8 m from bottom) from firing moment to 100 sec. when supply ducts are placed in ceiling and extract duct is placed close to the bottom on side walls. This is due to disadvantageous position of extract duct in ventilating high temperature air which rise because of buoyancy force. Thirdly, this study finds out effective ventilation direction and ventilation quantity to remove heat and combustion products generated by a fire by using VAV system. $CO_2$ concentration is used as a fire fume removal index. As soon as a fire happens, ventilation direction is changed in order to gather and drive out fire fumes. In case of three times ventilation quantity of ordinary one, $CO_2$ concentration and temperature have begun to decrease at 120 sec. after firing, i.e.fire fumes have begun to be removed.

  • PDF

Thermohydrodynamic Analysis and Pad Temperature Measurement of a Tilting Pad Journal Bearing for a Turbine Simulator (터빈 시뮬레이터용 틸팅패드 저널베어링의 열윤활 해석 및 패드 온도 측정)

  • Lee, Donghyun;Sun, Kyungho
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.112-118
    • /
    • 2017
  • Tilting pad journal bearings(TPJBs) are widely used for high speed rotating machinery owing to their rotordynamic stability and thermal management feature. With increase in the rotating speed of such machinery, an increasingly important aspect of TPJB design is the prediction of their thermal behaviors. Researchers have conducted detailed investigations in the last two decades, which provided design tools for the TPJBs. Based on these previous studies, this paper presents a thermohydrodynamic(THD) analysis model for TPJBs. To calculate pressure distribution, we solve the generalized Reynolds equation and to predict the lubricant temperature, we solve the 3D energy equation. We employ the oil mixing theory to calculate pad inlet temperature; further, to consider heat conduction via the pad, we solve the heat conduction equation for the pads. We assume the shaft temperature as the averaged oil film temperature and apply natural convection boundary conditions to the pad side and back surfaces. To validate the analysis model, we compare the predicted pad temperatures with those from previous research. The results show good agreement with previous research. In addition, we conduct parametric studies on a TPJB which was used in a gas turbine simulator system. The predicted results show that film temperature largely depends on the rotating speed and oil supply condition.

A Study on the Integrated Civil Service Model of the Next e-Government (차세대 전자정부의 대민통합서비스 모델 연구)

  • Noh, Kyoo-Sung;Jung, Jin-Taek
    • Journal of Digital Convergence
    • /
    • v.6 no.2
    • /
    • pp.13-21
    • /
    • 2008
  • The e-Government in Korea has made such good results as improvement of official work productivity and citizen service quality. However, e-Government in Korea involves many problems and subjects to must solve, especially, at the side of citizen services. Every public organization as supplier provides each service of themselves to the civilians. Citizens feel inconvenience yet, because they must visit and are supplied various civil services to one public affair from several public institutions. When we consider the paradigm shift of the e-Government service, the status and problems of the e-Government in Korea required more better service model to the citizen. To realize the citizen oriented service, the integration and linkage of the system infrastructure and applications among governmental organizations are required. In this changed situation, when new one/non-stop service model of the digital government is developed and launched, the e-Government can supply better service to the citizens. In this study, the model that we suggest is among the new service models of the e-Government, named the Integrated Civil Service Model. The e-Government involving the Integrated Civil Service Model can make more outcome, such as better civil life convenience, cost-effective results by processing time and cost reduction for public affairs of citizens.

  • PDF

Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates (다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가)

  • Lim, T.W.;Cho, D.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF

An Analysis of Location Marginal Prices Considering Demand Response Resources (수요반응자원을 고려한 지역별 한계가격 해석기법 연구)

  • Kim, Hyun-Houng;Kim, Jin-Ho;Kim, Hyeong-Jung;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.25-33
    • /
    • 2008
  • This paper presents a new approach of a evaluation of location marginal prices(LMPs) considering demand response resources in the competitive electricity market. The stabilization of the electric power supply and demand balance has been one of the major important activities in electric power industry. Recently, much attention is paid to the demand-side resources which are responsive to incentives or time-varying prices and existing power system planning and operation activities are incorporated with the so-called demand response resources. In this paper, we first present an analytical method for calculation of LMPs considering demand response resources and then break down the LMPs into three components. In this study, we assume that Korean power system consists of two major regions, one which is the metropolitan and the other is non-metropolitan region. In the case study, we have considered several LMPs cases with different use of locational demand response resource and we can obtain a locational signal to demand response resources. Also, the economics of demand response resources are evaluated, compared with the increase of transmission line capacity and of generation capacity.

A Study Interior Noise Reduction of a Maglev Train at Low Speed (저속 주행시 자기부상열차의 실내소음저감에 관한 연구)

  • 김현실;김재승;강현주;김봉기;김상렬
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.7
    • /
    • pp.253-260
    • /
    • 2001
  • A Study of interior noise reduction in the magelv train is presented. Tarin speed of interest is low such that aero-dynamic noise is negligible and power supply system is a dominant noise source. Based on the measurements of interior noise and acceleration levels during running and zero speed conditions, dominant noise sources are identified. After spectra characteristics of noise sources are investigated several noise reducing methods are studied such as STL increasement of floor panels. sealing. and absorption treatment It is found that the most important noise sources are VVVF inverter and SLM in running condition, whereas air conditioner and DC/DC converter are dominant in zero speed. Sine the major noise sources are under the floor complete sealing and high STL of the floor panel are shown to be the most crucial factors in noise reduction After sound absorbing material, which is polyurethan foam of 50 mm thickness, is thickness, is attached to the downward side of the floor in addition to sealing treatment, the interior noise is reduced by 3~4 dB.

  • PDF

A Numerical Analysis of Turbulent Flow Field and Heat Transfer in a Three Dimensional Room with a Heat Generating Obstacle (3차원 실내공간의 가열장애물에 대한 열전달 및 난류유동의 수치해석)

  • 정효민
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.107-119
    • /
    • 1995
  • Turbulent flow characteristics and heat transfer in a three-dimensional room with a desk-type heat generating obstacle have been investigated numerically by the k-$\varepsilon$ two equation turbulence model. The room mole has one supply opening on the ceiling and two exhaust openings on the side walls. Th results of the flow structure and heat transfer have been represented for air for the inlet velocities in the range 0.1-10.0m/s. As the results of the three dimensional simulations, the relationships between mean Nusselt number and Reynolds number are clarified.

  • PDF