• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.032 seconds

Induction Motor Starting Characterization with Power Factor Correction Capacitors (역률개선 콘덴서를 이용한 유도전동기 기동특성 분석)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.206-212
    • /
    • 2017
  • Induction motor torque is the reactive power is needed which corresponds to the exciting current to generate the magnetic flux as the product of current and flux. For use in the method of supplying the required reactive power to the induction motor power factor correction apparatus using a lot of ways to supply in place of the power supply side, when using a power factor compensation device can reduce the apparent power, the power factor can be improved. However, the distance to the emergency generator transformers or motors from the motor capacity is smaller but short and difficult to maneuver the theory and practice of the operating characteristics of the starting characteristics of the motor used a lot of large industrial plants were measured and analyzed. Therefore, this study investigated the motor starting Analysis and interpretation for the relationship with the large motor starting torque and speed during motor starting.

A Study on the Infrastructure of All-electric Houses in the Viewpoint of Hydrogen Economy (수소경제 관점의 전기에너지주택 보급기반 구축에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyeon-Ju;Kim, Kang-Sik;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.1
    • /
    • pp.100-109
    • /
    • 2012
  • In this paper, some ideas are proposed to establish the infrastructure of all-electric houses which are able to reduce primary energy consumption and $CO_2$ emission by adopting heat pump systems and induction heating cookers excluding the use of fossil fuel energy. This electrification concept is based on the consumption of only one type of energy which means electricity as secondary energy and the conventional fossil fuel energy is just consumed to generate electricity as primary energy. All-electric house is laid on the extension of the hydrogen economy in a long-term viewpoint so that the effectiveness of this new conceptual house is estimated analyzing the reduction of $CO_2$ emission. In this analysis, the balance of electricity supply and demand is considered including the construction of new power plants by renewable energy such as nuclear, IGCC and fuel cell because decarbonization is an essential element of hydrogen technology and economy and this action is accomplished in both supply and demand side of electricity. The results are able to contribute to develop various useful hydrogen policies and strategies and some detail researches are required previously to make the best application of this new conceptual house.

Anomaly of the Radial Artery Encountered During the Excision of Wrist Ganglion: A Case Report (손목 결절종제거술 시 경험한 요골동맥 기형의 치험례)

  • Kim, Chul-Han;Song, Woo-Jin
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.105-108
    • /
    • 2011
  • Purpose: An extensive knowledge of the arterial anatomy of the upper extremity and its variations is indispensable to the hand surgeon. We report a patient with anomalous radial artery, superficial course of two radial arteries, encountered during the excision of volar wrist ganglion. Methods: The patient was a 53-year-old man who had a painful mass on the left volar wrist for 1 year. Under general anesthesia, a curved incision was made around the mass. With the skin flaps retracted, the dome of the cyst was identified. Particular care was taken to identify and protect the radial artery, which was intimately attached to the wall of the ganglion. Two radial arteries completely encircled the ganglion. The pedicle was traced to the volar joint capsule, radiocarpal ligament. The joint was open and the capsular attachments were excised. Results: The patient made an uneventful recovery. There were two arterial pulsations at the volar side of the wrist joint. Compressing this site revealed that the major arterial contributor to blood supply in the hand was the ulnar artery. At angioCT, an anomaly of the radial artery was found with a duplication. The pathway of this aberrant artery was superficial to the original radial artery. It changed its course subcutaneously at the level of the tendon of the brachioradialis muscle, and crossing the wrist lateral to the original radial artery and ending in the deep palmar arch. Conclusion: Authors experienced a case of bifurcating radial artery encountered during the excision of ganglion on the volar of the wrist. Because these duplicated radial arteries make strong contributions to the thumb and index finger as well as to the deep palmar arch, when they are present there may be probably less blood supply to the hand from the ulnar artery. If the radial artery is palpated superficially on the brachioradialis muscle, it is important to remember the kind of anomaly.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Radionuclide Penogram in Diagnosis of Vasculogenic Impotence (혈관성 발기부전의 진단을 위한 방사성핵종 음경촬영술)

  • Lee, Jae-Tae;Kim, Kwang-Won;Ha, Sung-Woo;Lee, Kyu-Bo;Whang, Kee-Suk;Yoon, Yeo-Deuk;Park, Yoo-Kyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.209-214
    • /
    • 1989
  • Yasculogenic impotence is produced by abnormalities of vascular blood supply or drainage, and is the most common cause of various organic impotences. An increasing awareness of vascular causes of impotence has resulted from development of various diagnostic tests, but precise measurement of penile blood flow is difficult. Radionuclide penogram has been introduced recently to diagnose vasculogenic impotence. Forty-one impotent patients and 12 normal men were studied with radionuclide erection penogram using Tc-99m pertechnetate and an intracavernous injection of papaverine. We defined arteriogenic impotence as arterial index less than 0.66, and venogenic impotence as venous index greater than 0.09. By this criteria, the false positive ratio in normal men was 17%, and the false negative ratio in radically cystectomized patients was 0%. Side effects were small purpura of the penile shaft and dull pain during injection of papaverine. The radionuclide erection penogram was noninvasive and gave a dynamic evaluation of the arterial supply, venous drainage, and blood flow in the corporeal bodies. This method should be considered as a valuable adjunct to evaluate patients with vasculogenic impotence.

  • PDF

Development of Synthetic Jet Micro Air Pump (Synthetic Jet 마이크로 에어펌프의 개발)

  • Choi, J.P.;Kim, K.S.;Seo, Y.H.;Ku, B.S.;Jang, J.H.;Kim, B.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.594-599
    • /
    • 2008
  • This paper presents a micro air pump based on the synthetic jet to supply reactant at the cathode side for micro fuel cells. The synthetic jet is a zero mass flux device that converts electrical energy into the momentum. The synthetic jet actuation is usually generated by a traditional PZT-driven actuator, which consists of a small cylindrical cavity, orifices and PZT diaphragms. Therefore, it is very important that the design parameters are optimized because of the simple configuration. To design the synthetic jet micro air pump, a numerical analysis has been conducted for flow characteristics with respect to various geometries. From results of numerical analysis, the micro air pump has been fabricated by the PDMS replication process. The most important design factors of the micro air pump in micro fuel cells are the small size and low power consumption. To satisfy the design targets, we used SP4423 micro chip that is high voltage output DC-AC converter to control the PZT. The SP4423 micro chips can operate from $2.2{\sim}6V$ power supply(or battery) and is capable of supplying up to 200V signals. So it is possible to make small size controller and low power consumption under 0.1W. The size of micro air pump was $16{\times}13{\times}3mm^3$ and the performance test was conducted. With a voltage of 3V at 800Hz, the air pump's flow rate was 2.4cc/min and its power consumption was only 0.15W.

Characteristics of Icing Phenomenon on Injector in a Liquid Phase LPG Injection SI Engine (대형 액상분사식 LPG엔진 인젝터의 아이싱 특성연구)

  • Kim, C.U.;Oh, S.M.;Kang, K.Y.
    • Journal of ILASS-Korea
    • /
    • v.8 no.2
    • /
    • pp.1-6
    • /
    • 2003
  • The liquid phase LPG injection (LPLI) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system However. when a liquid LPG fuel is injected into the inlet duct of an engine, a large quantity of heat is extracted due to evaporation of fuel. This leads to freezing of the moisture in the air around the outlet of a nozzle, which is called icing phenomenon. It may cause damage to the outlet nozzle of an injector or inlet valve seat. In this work, the experimental investigation of the icing phenomenon was carried out The results showed that the icing phenomenon and process were mainly affected by humidity of inlet air instead of air temperature in the inlet duel. Also, it was observed that the total ice formed around the nozzle weighs at about $150mg{\sim}260mg$ after injection for ten minutes. And some fuel species were found in the ice attached at the front side of a nozzle, while frozen ice attached at the back of a nozzle was mostly' consisted of moisture of inlet air. Therefore, some frozen ice deposit. detached from front nozzle of an injector, may cause a problem of unfavorable air fuel ratio control in the small LPLI engine.

  • PDF

A Study on the LCC Type High Frequency DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 LCC형 고주파 공진 DC/DC 컨버터에 관한 연구)

  • Kim, Dong-Hee;Hwang, Gye-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.55-64
    • /
    • 2007
  • This paper represents characteristics and design example of series loaded LCC type high frequency resonant DC-DC converter with variable parallel capacitor in the secondary side of inductive power transformer. In this converter, ZVS(zero voltage switching) technique is applied to reduce turn-off switching losses, and the applied converter used the PFM switching pattern to control output voltage. The operating characteristics of the proposed converter is analyzed using nomalized parameter such as switching frequency and load factor with varing the secondary parallel resonant capacitor. The results of analysis show the operating characteristics and design method of the proposed converter using characteristic values. And the proposed converter can be applied for the contactless power supply with linear transfer system such as dean room facilities of semiconductor and Flat Panel Display.

Flow Analysis of a Engine Manifold with Multiple Injectors Arranged in a Row for Evaluation of Combustion Stability (연소안정성을 평가하기 위한 일렬형 다중 인젝터로 구성된 헤드의 매니폴드 유동해석)

  • Choi, Jiseon;Yu, Isang;Shin, Donghae;Park, Jinsoo;Ko, Youngsung;Kim, Seonjin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.622-627
    • /
    • 2017
  • In this study, the numerical analysis of propellant supply manifold of a sub-scale model combustor with the same combustion and acoustic resonance conditions as the real combustor was carried out. The analysis of the results is based on the shape of the manifold and the number and type of inflow channels. The manifold form of the main propellant was rounded so that the recirculation area was small and easy to manufacture. The liquid oxygen mainfold included a distributor to uniformly supply the flow, and since the kerosene manifold was directly in contact with the flame side, the inflow channel was formed at a radial $360^{\circ}$ so as to minimize the recirculation region. The liquid nitrogen manifold was configured as a radial inflow channel to reduce the velocity difference near the injector.

  • PDF