• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.023 seconds

A Study on the Methods for Recognition of Working-Career on Use to Heuristic of SEM (SEM(구조방정식모델)의 탐색적 연구를 이용한 근로경력 인정방안에 관한 연구)

  • Park, Jae-Hyun;Na, Hea-Sook
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2008
  • National technical qualification does not recognised degree of working-career in labor market and an industrial field situation. National qualification is supply to nurture expert manpower and accomplish of self-development and a duty accomplishment ability improvement at a side of personal. So, This study is purposed to find that a method for recognition of working-career on the national technical qualification system According to, this study is designed to questionnaire with BSC(Balaced ScoreCard), SEM(Structure Equation Model) with the delphi method, and is analysed using the AMOS 7.0 program package. Finally, This study is suggested growing to qualification standard for an examination a degree of master craftsman only under the change of national qualification systematization as a standard to operation and control.

A Research on Self-excitation and Power Factor Compensation of Induction Motor (유도전동기의 자기여자 및 역률보상에 대한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.236-240
    • /
    • 2014
  • Induction motor requires a rotating magnetic for rotation. Current required to generate the rotating magnetic field is magnetizing current. This magnetizing current is associated with the reactive power. This reactive power must be supplied from source side. Therefore, the power factor of the induction motor is low. So, the capacitor is installed on the motor terminals to compensate for the low power factor. Power supply company has recommended to maintain a high power factor to the customer. If the capacitor current is greater than the magnetizing current of the motor, there is a possibility that the self-excitation occurs. So it is necessary to calculate the optimal capacity capacitor current does not exceed the magnetizing current. In this study, we first compute the no-load current and the reactive power of the induction motor and then calculates the limit of the maximum power factor without causing self-excitation.

Servo Drives State of the Art in Industrial Applications - A Survey

  • Kennel, R.;Kobs, G.;Weber, R.
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2002
  • Servo drives with microcomputer control provide the possibility of using modern and sophisticated control algorithms. As an additional feature it is possible to implement parallel and/or redundant software and hardware structures to realise safe motion or similar security functions. Unfortunately microcomputer control also has some impact on the behaviour of servo drives. Control algorithm, cycle time, sensors and interface have to be perfectly synchronised. Special control schemes are necessary on the line side (power supply) to meet the actual requirements concerning EMC. This contribution presents experiences and results obtained from a modern digital drive system pointing out the influences of low and high accuracy position sensors and the interdependencies mentioned above.

Test of The HTS Power Cable Cooling System (초전도케이블 냉각시스템의 냉각특성 시험)

  • 염한길;고득용;김익생;김춘동;김도형
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.281-283
    • /
    • 2003
  • High temperature superconducting power cable requires forced flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65K and 80K. Subcooler heat exchanger uses saturated liquid nitrogen boiling on the shell side to subcool the circulating liquid nitrogen stream that cools the HTS cable. The paper describes performance tests of the cooling system. The test items are heat exchanging performance of subcooler. pressure drop between supply and return lines, heat transfer coefficient inside former, cable cryostat heat leak and simulation of electrical load of HTS cable.

  • PDF

A Study on the Economic Analysis of LED Lightings in All-Electric Houses Using California Standard Practice Test (캘리포니아 테스트를 이용한 전기에너지주택 LED조명의 경제성 분석에 관한 연구)

  • Hwang, Sung-Wook;Lee, Hyun-Ju;Nah, Hwan-Seon;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.1-7
    • /
    • 2011
  • Recently, all-electric house technology became one of the green growth technologies and is integrated with various areas such as electricity, machinery, architecture, material, and etc. Fossil fuel energy is used for heating and hot water supply in the conventional houses but electricity is adopted in the new conceptual houses to maximize advantages of electricity such as amenity, safety, cleanness, and so on. In this paper, an economic analysis is carried out when LED lightings are adopted using the California Standard Practice Test which has been used to estimate the effects of existing DSM (Demand Side Management) programs. The results are able to contribute to the diffusion of all-electric houses and the establishment of basic data and planning for DSM policies.

Optimal Design Methodology of Zero-Voltage-Switching Full-Bridge Pulse Width Modulated Converter for Server Power Supplies Based on Self-driven Synchronous Rectifier Performance

  • Cetin, Sevilay
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 2016
  • In this paper, high-efficiency design methodology of a zero-voltage-switching full-bridge (ZVS-FB) pulse width modulation (PWM) converter for server-computer power supply is discussed based on self-driven synchronous rectifier (SR) performance. The design approach focuses on rectifier conduction loss on the secondary side because of high output current application. Various-number parallel-connected SRs are evaluated to reduce high conduction loss. For this approach, the reliability of gate control signals produced from a self-driver is analyzed in detail to determine whether the converter achieves high efficiency. A laboratory prototype that operates at 80 kHz and rated 1 kW/12 V is built for various-number parallel combination of SRs to verify the proposed theoretical analysis and evaluations. Measurement results show that the best efficiency of the converter is 95.16%.

Analysis and Design of a Bidirectional Cycloconverter-Type High Frequency Link Inverter with Natural Commutated Phase Angle Control

  • Salam, Zainal;Lim, Nge Chee;Ayo, Shahrin Md.
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.677-687
    • /
    • 2011
  • In this paper a cycloconverter-type high frequency transformer link inverter with a reduced switch count is analyzed and designed. The proposed topology consists of an H-bridge inverter at the transformer's primary side and a cycloconverter with three bidirectional switches at the secondary. All of the switches of the cycloconverter operate in non-resonant zero voltage and zero current switching modes. To overcome a high voltage surge problem resulting from the transformer leakage inductance, phase angle control based on natural commutation is employed. The effectiveness of the proposed inverter is verified by constructing s 750W prototype. Experimentally, the inverter is able to supply a near sinusoidal output voltage with a total harmonic distortion of less than 1%. For comparison, a PSpice simulation of the inverter is also carried out. It was found that the experimental results are in very close agreement with the simulation.

Integrated DC-DC Converter Based Energy Recovery Sustainer Circuit for AC-PDP

  • Park, Jae-Sung;Shin, Yong-Saeng;Hong, Sung-Soo;Han, Sang-Kyoo;Roh, Chung-Wook
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.878-885
    • /
    • 2012
  • A new sustainer with primary-side integration of DC/DC converters and energy recovery(SPIDER) circuits is proposed. The proposed circuit operates as a DC-DC converter during address period and energy recovery circuit during sustain period. Therefore, the conventional three electronic circuits composed of the power supply, X-driver, and Y-driver can be reduced to one circuit. As a result, it has desirable advantages such as a simple structure, less mass, fewer devices and cost reduction. Moreover, since the Zero Voltage Switching (ZVS) of all power switches can be guaranteed, a switching loss can be considerably decreased. To confirm the operation, validity, and features of the proposed circuit, experimental results from a prototype for 42-inch PDP are presented.

Direct Load Control System for Air-conditioner (에어컨부하 직접 제어시스템 실용화 연구)

  • Ko, Sang-Cheon;Lee, Sang-Yun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3051-3053
    • /
    • 1999
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to Demand Side Management. Increasing Electric power consumption, they adopt a direct load management to accomplish low cost and stability of electric supply. Following this trend, KEPCO is researching a Direct Load Control System for Air Conditioner. This Paper presents the development results of the Direct Load Control System to Control electric power consumption of Conditioner in summer period this year.

  • PDF

Estimation of Optimal Target Amount for Efficiency Improvement Program of DSM (효율향상 프로그램의 최적 수요관리목표량 산정)

  • So, Chol-Ho;Park, Jong-Jin;Kim, Jin-O;Cho, Joong-Sam
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.842-843
    • /
    • 2007
  • In this paper, the proper rebate level can be decided in programs of energy savings by solving an optimization problem with an objective function, which satisfies a maximum value of total energy savings. And then, each prevalence amount is estimated by using virtual Bass model which is a function of rebate level, instead of the conventional Bass model. Finally, by cost/benefit analysis of the estimated prevalence amounts, the priority order is obtained for the investment of each program. The priority order obtained in this way may result the improvement of investment efficiency for DSM(Demand-Side Management) programs and the reasonable plan decision for supply and demand in power system.

  • PDF