• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.027 seconds

New proposal for skin grafts on tendon-exposed wounds

  • Um, Jung Hwan;Jo, Dong In;Kim, Soon Heum
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.86-90
    • /
    • 2022
  • Performing a skin graft is not feasible for tendon-exposed defect reconstruction because tendons are fibrous connective tissues with relatively poor blood supply. This study proposes a method to effectively perform skin graft surgery in tendon-exposed wounds. A 48-year-old male patient with diabetes mellitus had a very large left dorsal foot defect (8×8 cm). The wound bed had healthy granular tissue, with tendon exposure. The tendons were turned over so that the posterior side would behave as the anterior side. The edge of the paratenon was then fixed together to the surrounding granulation tissue or dense remnant fascia using absorbable sutures, and the close granulation tissue was approximated and buried. A split-thickness skin graft was performed after 1 week. The graft site was stably taken on postoperative day 3. A small disruption was then observed at the graft site within 1 week postoperatively, but conservative treatment was continued for 1 month, after which the defect site was completely restored. This technique can increase the success rate of skin grafts for defects with tendon exposure.

Characteristics of Core Sedimentary Facies at the Ulleung Basin in the East Sea of Korea (한국 동해 울릉분지 코어 퇴적상 특성)

  • Lee, Byoung-Kwan;Lee, Su-Woong;Kim, Hong-Tae;Kim, Seok-Yun
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.829-837
    • /
    • 2011
  • A study on the grain size change, sedimentary facies and age indicator of volcanic tephra was analysis through four cores (P1 ~ P4) at the Ulleung Basin in the East Sea of Korea. The two cores (P1 and P2) were collected in the northeastern side of the Ulleung Basin (about 2,000 m in water depth), while the other two cores (P3 and P4) with the water depth of about 1,500 m and 1,700 m, respectively, were collected from the continental slope of the southwestern and western side of the Ulleung Basin. Four sedimentary facies and eight sedimentary subfacies were identified. The four facies were massive sand, bioturbated mud, homogeneous mud, and laminated mud. The eight subfacies were further divided as pumiceous ash massive sand, scorieaous massive sand, plain bioturbated mud, pyrite filamented bioturbated mud, distinctly laminated mud, indistinctly laminated mud, thinly laminated mud and homogeneous mud. The homogeneous mud was not found in the core of P3 which is located in the western side of Ulleung Basin (close to the Korean coast). In the case of laminated mud facies, the thinly laminated mud facies was dominated in the lower part of core sequences of the Ulleung Basin (P1 and P2), while the indistinctly laminated mud were overally distributed in the core sequences from the continental slope of Ulleung Basin. The Tephra layers from the core sequences of central Ulleung Basin were more dominated and distinctive than those from the core sequences of continental slope. This is related to the distance from the volcanic source and the amount of sediment supply. The core locations of Ulleung-Oki Tephra layers in the central Ulleung Basin were in the upper part of core sequences, while those in the continental slope were in the lower part of core sequences. This is indicated that the amounts of sediment supply in the continental slope after the Ulleung-Oki eruption were very high and different sedimentary environment between upper and lower of Tephra layer.

Experimental Study of the Heat Transfer Rate of the Plate Fin-Tube Condenser for a Household Refrigerator (냉장고용 판형 핀-관 응축기의 열전달 성능에 관한 실험적 연구)

  • Son, Young-Woo;Lee, Jang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4802-4808
    • /
    • 2014
  • A plate-fin tube type heat exchanger has a lighter weight, approximately 30%, than the conventional circular-fin type condenser of household refrigerator. Because the low weight means low cost, it can have significant effects on the growth of related businesses if similar performance can be guaranteed. To check the possibility of the use of such a plate fin-tube condenser, experimental evaluations were performed in this study. Four different condensers including a conventional circular fin-tube condenser were used for the test. A well designed refrigerant supply system was used to supply similar conditions with a refrigerator, and the heat transfer rate and pressure drops of air side were measured precisely. As a result, the plate fin-tube type condensers showed a lower heat transfer rate of more than 13% than the conventional circular fin-tube type condenser, but the air side pressure drop was reduced and the heat transfer per unit weight was increased. Therefore, it shows the possibility of the use of a plate fin-tube type condenser after optimizing the air flow path and increasing the air flow to make a similar heat transfer rate.

The Study For a New Positioning Strategy For the Performance Arts (공연예술 수요개발 촉진을 위한 포지셔닝(Positioning) 전략 제안)

  • Park, Joon Hyoung
    • Review of Culture and Economy
    • /
    • v.20 no.3
    • /
    • pp.87-114
    • /
    • 2017
  • The Supply side of performance arts has been pretty much developed since the establishment of ARCO. The development level of the demand side, however, was much lower than that of supply side. This unbalance make it difficult to achieve the goal and to complete the mission of ARCO's assistant to the performance arts. Unlike the existing research for solving this problem, this study suggests the positioning strategy of a new value of performance arts for solving this problem. This positioning is, instead of meeting the experiential and symbolic needs, targeting the functional needs to solve the life problems to be faced with aging, for example, the problems from education, human relationship and health. The new positioning will make the demand for the performance arts belong to the top priority group in the expenditure list of consumers because the perceived concept of performance arts will be changed from the "Wants" consumption to "Should be" consumption like a expenditure of private education for children and that of health problems. Therefore, this new positioning is surely expected that the development of new demand from the new position is pretty much higher than that of present positioning. This study also suggests practical strategies, PR and cross functional management system for the implementation of this new positioning.

Comparison of Main Circuit Type Characteristics of LED Driver for Output Ripple Reduction (출력 리플 저감을 위한 LED 드라이버의 주회로 방식 특성 비교)

  • Park, Dae-Su;Kim, Tae-Kyung;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.491-499
    • /
    • 2019
  • Recently, there has been increasing demand for power quality in power supply devices. The IEC 61000-3-2 standard requires that the AC / DC power supply for lighting meet the specifications for the power factor (PF) and total waveform distortion (THD). In addition, advanced countries in Europe are regulating the ripple rate as 15 ~ 30% for the flicker phenomenon caused by the change in the amount of foot energy due to the change in current of the output terminal. Therefore, domestic standards and regulations are being updated. This study adopted the Flyback converter to satisfy the PFC standard, and has the circuit first and second insulation function. To reduce the low frequency ripple of the LED current, Flyback, Coupled Inductor, LC parallel resonance filter, LLC resonance filter, and Cuk were simulated by PSIM to mimic each LED driving circuit. A coupled LC resonant circuit with a coupled inductor on the primary side and LC resonance on the secondary side was also proposed for output side ripple reduction.

STUDY ON THE THERMAL-FLUID ANALYSIS OF CRYOGENIC CHAMBER FOR COLD CLIMATE TEST OF LARGE WIND TURBINE PARTS (대형 풍력발전기 부품의 극한 환경 시험을 위한 극저온 챔버의 열유동 해석에 대한 연구)

  • Kim, M.K.;Kang, Y.H.;Park, W.G.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.8-14
    • /
    • 2015
  • More and more, spaces are decreasing which satisfy multiple requirements for wind power plants. However, areas which have excellent wind resources and are free to civil complaints occupy a large space, although they are exposed to the cryogenic environment. This study conducted a thermal-fluid analysis of a cryogenic chamber for testing large wind turbine parts exposed to the cryogenic environment. The position of supply air is placed to the upper area to compare each cooling performance for each location of various outlets in mixing ventilated conditions. The study carried out CFD analysis for the chamber both with and without a test object. For the cases without the test object, the air temperature of the upper supply and down extract type chamber was cooled faster by 5-100% than the others. However, for the cases with the test object, the object temperature of upper supply and center extract on the opposite side type chamber was cooled faster by 33-132% than the others. The cooling performance by the air inside the chamber and the test object did not show the same pattern, which implicates the need to consider the cooling performance by not only the air but also the test object in the large cryogenic chamber design for testing large parts.

Model of the RFID-based Product Traceability Service in u-SCM (u-SCM에서 RFID 기반 제품 추적 서비스 모델)

  • Shin, Myeong-Sook;Song, Gi-Beum;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.954-957
    • /
    • 2007
  • The u-SCM to persue unification of the whole Supply Chain through ubiquitous computing and technical interface is raised its head for enterprise to secure endless competitive advantage and grow up constantly. This can be especially a matter of primary concern for business process elevation on various industry. The other side, The Traceability Service propelled both nationally and internationally is propelled specific industry to offer visibility and traceability of each manufacture on supply chain related to induce RFID, but standard Traceability Service Architecture isn't decided yet. This paper propose Model of Product Traceability Service which is based on EPCglobal Network to be the whole world standard architecture for the sake of efficient and perfect manufacture management on entire supply chain based on RFID.

  • PDF

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

A Study on the CFD Analysis and Estimation of the Energy Efficiency of Cryogenic Chamber for Extreme Climate Test (극한 환경 시험을 위한 극저온 챔버의 CFD 해석 및 에너지 효율 평가에 관한 연구)

  • Kang, Yul-Ho;Kim, Min-Kyu;Park, Warn-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.81-88
    • /
    • 2016
  • There are many types of national and international standards for low temperature tests depending on the products. This study conducted CFD analysis and estimation of the energy efficiency of the chamber both with and without a test object by considering variations of COP and specific volume according to temperature. The supply air was located in the upper area to compare the cooling performance for each location using various outlets in mixed ventilated conditions. For cases without the test object, the air temperature of the upper supply and center extract on the opposite side type chamber cooled faster than other areas by 4.3~29.8%. However, for cases with the test object, the object temperature of the upper supply and lower extract type chamber cooled faster than the other areas by 7.2~31.5%. The cooling efficiency of the air inside the chamber and the test object did not show the same pattern, which indicates the need to consider the cooling performance by not only the air but also the test object in the cryogenic chamber design for testing.

A Study on the Inverter Type Neon Power Supply Using a Piezoelectric Transformer (압전 변압기를 이용한 인버터식 네온관용 변압기에 관한 연구)

  • 변재영;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.504-511
    • /
    • 2003
  • In this paper, inverter type neon power supply using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed neon power supply is composed of basic circuit and blocks, such as rectifier part, frequency oscillation part and piezoelectric transformer and resonant half bridge inverters. In this paper for complement the low power limitation, piezoelectric transformer at parallel connected driving by inverter is studied for noon tubes system of high power. When piezoelectric transformer is connected with parallel, LC filter connection method with parallel and selection of inductance L and capacitor C of primary side is suggested for reduce unbalanced current at the terminal of each transformer. Piezoelectric transformers use piezoelectric ceramic devices. Thus it is wireless therefore it has high power density, high Isolation level, low loss, more light, and miniaturization. In addition, high voltage transfer ratio is expected because there is no leakage inductance. Also, it has economic merit that the electrical loss Is low because structure is simple, small and tighter weight.