• 제목/요약/키워드: Supply Air Temperature

검색결과 475건 처리시간 0.027초

한국에서의 기후변화와 오징어 어획의 확장 (Climate Change and Expansion of Squid Catches in Korea)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.516-524
    • /
    • 2017
  • Objectives: The annual catch of the common squid Todarodes pacificus in Korean coastal waters has gradually increased since the late 1980s. We investigated the long-term effects of climate variability on the variation in catches of the squid in the offshore fisheries of Korea. Methods: Moving average method, correlation analysis, and regression analysis were used to determine the relationship between the environmental factors and fluctuation in the catch of the squid during the past 30 years (1981- 2010). A ten-year moving average was calculated and used for each variable. Results: Squid catches in Korean coastal waters increased over time, and there were significant variations within every ten years (p < 0.001). Air temperature, atmospheric pressure, and wind grade among the meteorological factors, alongside sea surface temperature (SST) and concentrations of phosphate phosphorous, and nitrite/nitrate nitrogen in the sea water increased and were positively related with the catch size of squid (p < 0.001). However, salinity decreased and was negatively related with the catch size (p < 0.001). The increase in air temperature and SST was almost parallel, although there was a time lag between the two factors. Conclusion: These results suggest that there is a causal association between climate change and squid populations. Climate change, especially ocean warming, appears to have been largely favorable for squid range expansion into Korean seas. Although the expansion may be helpful for the human food supply, the safety of the squid caught should be monitored since the concentrations of phosphorous and nitrogen in the sea water increased, which indicates that Korean seas have grown gradually more polluted.

시설농업난방 경유대체유로서 폐타이어오일의 연소 특성 (Combustion Qualities of Waste Tire Oil as Substituting Light Oil for Greenhouse Heating)

  • 김영중;유영선;강금춘;이건중;윤진하
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.481-488
    • /
    • 2000
  • This study was initiated in order to find alternative fuel substituting for light oil the most common fuel for heating greenhouse. The tire oil used in this research was produced by pyrolysis process, one of the final products besides steel string and carbon black in which waste tires as a form of chopped pieces broken by shredding machine are heated up to 200~30$0^{\circ}C$ with maximum restraining of oxygen supply. In order to justify light oil equivalent qualities in tire oil combustion characteristics were defined in the way of comparing kinetic viscosities in the wide range of temperature flame sizes and exhaust gas components in the various combustion conditions. We found that kinetic viscosity of tire oil was lower than light oil by 1 to 2 cSt in the temperature range showing better flowing mobility in the fuel line of the burner and no significant difference in flame size between the two oils in the all combustion treatments. However much more NO and SO$_2$ were detected from the exhaust gases of tire oil than light oil combustions. In fact tire oil contains more nitrogen and total sulfur, by 25 times and 40 times respectively than light oil according to the composition analysis. Tolerable limit for SO$_2$discharge amount defined by the national air pollution standards is under 540ppm so tire oil combustion satisfies the requirement though. It is desirable if sulfur and nitrogen filtering process shall be added in the tire oil production line. Except the exhaust gas components all greenhouse heating qualities of tire oil including hot air temperature are very identical to those of light oil.

  • PDF

열펌프를 이용한 양액베드 냉난방시스템 개발 (Development of Heating and Cooling System with Heat Pump for Nutrient Solution Bed In Greenhouse)

  • Kang, Geum-Chun;Kim, Yeong-Jung;Yu, Yeong-Seon;Baek, Lee
    • Journal of Biosystems Engineering
    • /
    • 제27권6호
    • /
    • pp.565-572
    • /
    • 2002
  • In order to control the root-zone temperature of greenhouse crops in the hydroponics at hot and cold season, heat pump system for cooling and heating was built and tested in this work. The system was air-to-water type and vapour compression type. The heating and cooling mode was selected by the four way valve. Capacity of the compressor was 3.75㎾ and heat transfer area of the evaporator and the condenser were 3.05㎡ and 0.6㎡, respectively. According to the performance test, it could supply heat of 42,360 to 64,372kJ/h depending on the water circulation rate of 600 to 1,500ℓ/h, respectively, when indoor air temperature was 10∼20$\^{C}$. COP of heat pump system was 3.0 to 4.0 in the heating mode. But, COP of the cooling mode was 1.3 to 2.1 at indoor temperature of 20∼35$\^{C}$. The feasibility test in the greenhouse the developed heating and cooling system was installed, showed that the heating cost of the developed system was only about 13% of that of the conventional heating system. The heating cost of the developed system was 367won/day(electric consumption 9.7㎾h/day), while that of the conventional system was 2,803won/day(oil consumption 7.7ℓ/day) at the same heating mode.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

비화재보를 위한 X-ray tube 내 열 유동해석에 관한 연구 (A study on thermal fluid analysis in X-ray tube for non-fire alarm)

  • 윤동민;전용한
    • Design & Manufacturing
    • /
    • 제16권2호
    • /
    • pp.33-38
    • /
    • 2022
  • Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.

온도구배야외챔버를 이용한 고온에서의 벼 생육반응 및 수량성 평가 (Evaluation of yield and growth responses on paddy rice under the extremely high temperature using temperature gradient field chamber)

  • 오도혁;류재현;조윤형;김원식;조재일
    • 한국농림기상학회지
    • /
    • 제20권1호
    • /
    • pp.135-143
    • /
    • 2018
  • 온난화에 따른 벼의 생산량 변화는 우리나라뿐만 아니라 동아시아의 식량 수급에 매우 중요한 이슈 중 하나이다. 본 연구에서는 야외 온도보다 $0{\sim}3^{\circ}C$ 높은 환경을 형성해 주는 야외 온도구배챔버(TGFC)를 이용하여 고온이 벼의 생육과 생산량에 미치는 영향을 실험하였다. 챔버는 A, B, C 총 3개를 본 연구에 이용하였으며, C챔버는 출수기 이후 온도구배 처리를 하지 않았다. 벼 품종은 중만생종인 일미를 중묘로 이앙하였으며, 비료는 표준 시비량을 고려하여 N(질소) 9 kg, P(인) 4.5kg, K(칼륨) 5.7kg을 기준으로 처리하였다. A, B, C 모든 챔버에서 영양생장기 동안 고온 조건의 벼가 상대적으로 생육 속도가 빨랐다. 하지만, 출수 후 40일 동안의 평균 온도로 정의한 등숙기 온도가 계속 고온으로 유지될 경우 등숙률과 평균 종실 중이 온도에 비례하여 점진적으로 감소하였다. 특히 2016년 기상 조건을 기점으로 등숙기 온도가 증가함에 따라 불임이 증가하여 등숙률은 급격히 감소하였고, 그 영향으로 단위 면적당 수량도 크게 낮아졌다. 결국 동화산물의 분배 불균형을 초래해 출수 이후에도 잎의 엽록소 함량이 낮아지지 않았으며 비정상적인 늦이삭이 출현하였다. 하지만 늦이삭의 생산량이 고온으로 인해 감소한 정상 이삭의 생산량을 만회하기에는 매우 부족한 정도였다. 향후 지구 온난화로 인한 벼 생육기간의 고온은 벼의 생육을 촉진시키고, 출수 및 개화시기를 단축시키며 등숙기에도 고온이 지속 될 시 등숙률과 평균종실의 무게를 감소시켜 최종적으로 벼의 생산량 및 품질을 감소시킬 것으로 예측된다.

스테인리스-아세톤 히트파이프의 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of Stainless-Acetone Heat Pipe)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.489-496
    • /
    • 2000
  • This study was conducted in order to find an ideal working fluid kind and a proper filling amount in the heat pipe as well as an inclined angle of heat pipe when they are placed to recover exhaust gas heat in the hot air heater. Followings are the findings of this research. 1. Of the four different working fluids-gasoline kerosene distilled water and acetone-acetone filled heat pipe showed the best performance giving out more homogeneous temperature profile on the radiating part than the kerosene and gasoline heat pipe an carrying out heat transmitting function better than the distilled water heat pipe by 10~2$0^{\circ}C$ higher on the radiating part. Acetone would be a good choice for recycling of exhaust gas heat in the hot air heater. 2. Of the filling amount of working fluid inside the heat pipes dry-out situations possible caused by insufficient filling were found in the filling amount of 5, 7.5 and 10% heat pipes as heat supply rate increases gradually in the range of 50 to 15kJ/sec. but no dry-out and stabilized heat transmitting performance occurred in the heat pipes of 12.5 and 15% filling at the same heat supply rate. It recommends that filling amount shall exceed 12.5% at least with the working fluids of this experiment. 3. The test revealed that the heat transmitting performance of heat pipe was more affected by filling amount rather than inclined angle.

  • PDF

LPG 엔진에서 수소첨가에 따른 배기 성능과 열효율에 미치는 영향 (Effects of hydrogen-enriched LPG fuelled engine on exhaust emission and thermal efficiency)

  • Kim, jinho;Cho, unglae;Choi, gyeungho
    • 한국수소및신에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.169-176
    • /
    • 2001
  • The purpose of study is to obtain low-emission and high-efficiency in LPG engine with hydrogen enrichment. The test engine was named heavy-duty variable compression ratio single cylinder engine (VCSCE). The fuel supply system provides LPG/hydrogen mixtures based on same heating value. Various sensors such as crank shaft position sensor (CPS) and hall sensor supply spark timing data to ignition controller. Displacement of VCSCE is $1858.2cm^3$. VCSCE was runned 1400rpm with compression ratio 8. Spark timing was set MBT without knocking. Relative air-fuel ratio(${\lambda}$) of this work was varied between 0.76 and 1.5. As a result, i) Maximum thermal efficiency occurred at ${\lambda}$ value 1.0. It was shown that thermal efficiency was increased approximately 5% with hydrogen enrichment at same ${\lambda}$ value. ii) Engine-out carbon monoxide (CO) emissions were decreased at a great rate under LPG/hydrogen mixture fuelling. iii) Total hydrocarbon (THC) emission was much exhausted in rich zone, same as CO. But THC was exhausted a little bit more in lean zone. iv) Finally, engine-out oxides of nitrogen (NOx) was increased with ${\lambda}$ value 1.0 zone at a greater rate with hydrogen enrichment due to high adiabatic flame temperature.

  • PDF

지역난방 열사용시설 자동제어시스템 개선을 통한 회수온도 저감 연구 (The Decrease of Return Temperature by Improvement of the Consumer's Control System in District Heating)

  • 하승규;김연홍;이훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.245-251
    • /
    • 2006
  • The main idea of this study is to turn attention on the question of good cooling ability of customer substations in large district heating networks. The main reason for that is based on our experience that the optimization of district heating very often is directed toward production, whereas questions of optimal distribution are neglected if only the necessary load can be supplied and the customer's request for comfort is met. Our view is that low return temperature(operational temperature differences, ${\Delta}T$) in district heating systems is an Important feature for efficient net operation and gives both economic and operational benefits to the district heating supplier Furthermore, it is as well a prerequisite for meeting the customers demand for reliable supply of the heat load. However, in many practical cases we have seen that district heating return temperatures are higher than necessary. Hence, the aim of the study is to propose and verify a method for detection of the most critical consumers of the net and to identify the reasons for resulting high return temperature. From the results, temperature control system is presented as one of the most important reason of high return temperature in DH networks.

  • PDF

급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구 (A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser)

  • 임석영;장현재
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.