• Title/Summary/Keyword: Superimposition

Search Result 167, Processing Time 0.02 seconds

Experimental panoramic positioning errors for inducing condylar cutoff and superimposition of cervical vertebrae on the mandibular ramus (하악과두 잘림과 경추의 하악지 겹침을 야기하는 파노라마방사선촬영 오류)

  • Kang, Byung Cheol;Kim, Min Jong;Park, Hye Sun;Hwang, Sel Ae;Yoon, Suk Ja;Lee, Jae Seo
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.134-141
    • /
    • 2018
  • Purpose: To measure the head tilting angle creating initial condylar cut-off and to find the head position inducing the superimposition of the cervical vertebrae over the mandibular ramus on panoramic radiograph. Materials and Methods: The panoramic radiographs were taken with Didactic skull on cervical spine model (Scientific GmbH, Hamburg, Germany) using Kodak 8000c Digital Panoramic radiography. For the inherent radiolucency of the plastic skull model, radiopaque 1 mm diameter lead wires were attached along the margin of the mandibular condyle, ramus, mandibular body, cervical vertebrae, and FH plane of the skull model. For measuring the head tilting angle creating the condylar head cutoff, panoramic radiographs were taken by tilting the FH plane downward in 5 degree increments. For finding the distance between transverse process of the third cervical vertebra and gonion inducing superimposition of cervical vertebrae on the mandibular ramus, panoramic radiographs were taken by decreasing the distance in 0.5 cm increments. Result and Conclusion: The condylar cutoff began to appear when the head of skull model was tilted downward by 15o. As the head tilting angle increasing, the condylar cutoff became more prominent. The superimposition of cervical vertebrae over the mandibular ramus began to appear when the distance between the gonion and third cervical vertebra was 1.0 cm. As the distance decreasing, the superimpostion became more prominent.

  • PDF

Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear

  • Choi, Jin-Il;Cha, Bong-Kuen;Jost-Brinkmann, Paul-Georg;Choi, Dong-Soon;Jang, In-San
    • The korean journal of orthodontics
    • /
    • v.42 no.5
    • /
    • pp.235-241
    • /
    • 2012
  • Objective: The purpose of this study was to evaluate the validity of the 3-dimensional (3D) superimposition method of digital models in patients who received treatment with rapid maxillary expansion (RME) and maxillary protraction headgear. Methods: The material consisted of pre- and post-treatment maxillary dental casts and lateral cephalograms of 30 patients, who underwent RME and maxillary protraction headgear treatment. Digital models were superimposed using the palate as a reference area. The movement of the maxillary central incisor and the first molar was measured on superimposed cephalograms and 3D digital models. To determine whether any difference existed between the 2 measuring techniques, intra-class correlation (ICC) and Bland-Altman plots were analyzed. Results: The measurements on the 3D digital models and cephalograms showed a very high correlation in the antero-posterior direction (ICC, 0.956 for central incisor and 0.941 for first molar) and a moderate correlation in the vertical direction (ICC, 0.748 for central incisor and 0.717 for first molar). Conclusions: The 3D model superimposition method using the palate as a reference area is as clinically reliable for assessing antero-posterior tooth movement as cephalometric superimposition, even in cases treated with orthopedic appliances, such as RME and maxillary protraction headgear.

Comparision of two cephalometric superimposition methods - Nasion-sella line method and Anterior cranial base method (두가지 두부 방사선 사진 중첩 방법의 비교 - Nasion-Sella line 중첩과 Anterior cranial base 중첩)

  • Kyung, Seung-Hyun;Moon, Yon-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.633-641
    • /
    • 1997
  • Spatial change of craniofacial structures from growth or orthopedic force is usually evaluated by cephalometric superimpositions at different points in time.As the evaluation cu be changed according to cephalometric superimposition method,selettion for correct superimposition method is very important.Double registration of nineteen pairs of female lateral head films,their growth period is average 3.7 years and age is overage 10.7 years,were performed by two observers.Comparisions was made between two methods and the results revealed the following, 1. NS line and ACB superimpositions ate not markedly different in reliability due to almost same registration error of them. 2. The investigation was undertaken to examine interobserver difference.In NS line method, there is no significance in all measurements. In ACB method,significant difference was revealed in 4 measurements of 7 measurements was 3. In the investigation of intermethod difference, there is no significance between NS line and ACB superimpositions

  • PDF

Evaluation of mechanical and projective standardization in digital subtraction radiography (디지털 공제 방사선 촬영술에 있어서 기계적 및 투사적 규격화의 평가)

  • Choi Bong-In;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.215-224
    • /
    • 1998
  • The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleling technique with Rinn XCP only and with occlusal bite registration for geometric standardization using bilateral mandibular premolar and molar regions of two dry human skulls. 1. The SD of the overall subtraction images of the premolars and molars of the non-reconstructed, that is, the manual superimposition showed statistically significant difference between the non-registered and registered groups. 2. In non-reconstructed and non-registered cases, the quality of the subtraction images were improved when superimposition was focally done and this was more evident in areas where the radiographic images tend to be distorted due to anatomic reasons. 3. In non-reconstructed and registered cases, the subtraction images were consistent regardless of the anatomic site or the focus of superimposition. This means that the geometric standardization with only occlusal bite registration could produce serial radiographs which is suitable for subtraction. 4. The SD of the overall subtraction images of the premolars and molars of the reconstructed, that is, the automatic superimposition showed statistically insignificant difference between the non-registered and registered groups. This means that using reconstruction, subtraction radiography is possible without occlusal bite registration. 5. In reconstructed and non-registered cases, compatible quality of the subtraction images were obtained regardless of the anatomic site or area of the corresponding points. 6. In reconstructed and registered cases, best subtraction images whose quality showed sensitivity to the areas of corresponding points were obtained.

  • PDF

The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error (중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구)

  • Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models

  • Nalcaci, Ruhi;Kocoglu-Altan, Ayse Burcu;Bicakci, Ali Altug;Ozturk, Firat;Babacan, Hasan
    • The korean journal of orthodontics
    • /
    • v.45 no.2
    • /
    • pp.82-88
    • /
    • 2015
  • Objective: The aim of this study was to evaluate the reliability of measurements obtained after the superimposition of three-dimensional (3D) digital models by comparing them with those obtained from lateral cephalometric radiographs and photocopies of plaster models for the evaluation of upper molar distalization. Methods: Data were collected from plaster models and lateral cephalometric radiographs of 20 Class II patients whose maxillary first molars were distalized with an intraoral distalizer. The posterior movements of the maxillary first molars were evaluated using lateral cephalometric radiographs (group CP), photocopies of plaster models (group PH), and digitized 3D models (group TD). Additionally, distalization and expansion of the other teeth and the degrees of molar rotation were measured in group PH and group TD and compared between the two groups. Results: No significant difference was observed regarding the amount of molar distalization among the three groups. A comparison of the aforementioned parameters between group PH and group TD did not reveal any significant difference. Conclusions: 3D digital models are reliable to assess the results of upper molar distalization and can be considered a valid alternative to conventional measurement methods.

A Study on Evaluation Method of Ride Comfort Considering Superimposition of Vertical and Horizontal Curve (종곡선과 평면곡선 경합을 고려한 승차감 평가기법에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Kim, Eun-Kyum;Choi, Il-Yoon;Kang, Yun-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.3
    • /
    • pp.309-316
    • /
    • 2010
  • When the horizontal and vertical curves are superimposed in railway alignments, which affects the running stability, ride comfort, and track maintenance costs. However, when designing new lines or realigning existing ones, there are many cases of superimposition caused by the existing fixed points (bridge, tunnel, turnout, and catenary system, etc) on the conventional lines and undesirable impacts on the environment, etc. In this study, when the horizontal and vertical curves are superimposed, in order to optimize the horizontal curve in aspect of the ride comfort, the object function was developed and verified by vehicle dynamic analysis. Also, the solution algorithm for simplified evaluation method was presented.

Risk factors for external root resorption of maxillary second molars associated with third molars

  • Choi, Jinwoo
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • Purpose: This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images. Materials and Methods: The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients(147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis. Results: The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (P<0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s(P<0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s(P<0.05). Conclusion: ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.

Determination of tunnel support pressure under the pile tip using upper and lower bounds with a superimposed approach

  • Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.587-605
    • /
    • 2016
  • This study aimed to develop upper and lower bounds to predict the tunnel support pressure under the pile tip during the circular tunnel excavation. Most previous studies on the upper and lower bound methods were carried out for the single ground structures, e.g., retaining wall, foundation, ground anchor and tunnel, in the homogeneous ground conditions, since the pile-soil-tunnel interaction problem is very complicated and sophisticated to solve using those bound methods. Therefore, in the lower bound approach two appropriate stress fields were proposed for single pile and tunnel respectively, and then they were superimposed. In addition, based on the superimposition several failure mechanisms were proposed for the upper bound solution. Finally, these upper bound mechanisms were examined by shear strain data from the laboratory model test and numerical analysis using finite element method.

Trial Manufacture of Ozone Generator Using Silent Discharge Type and Improvement Properties of the Water Quality in the Lake (무성방전형 오존발생장치 제작 및 수질 개선 특성)

  • 임헌찬;김진규;우성훈
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.125-129
    • /
    • 2001
  • ln this paper, a ozone generator using superimposition of silent discharge has been designed and manufactured. This type ozone generator is equipped with three electrodes and two gaps. Ozone is generated by superimposition of silent discharge, which is respectively come from two gaps. The maximum values of ozone concentration, ozone generation flow and ozone energy field were obtained 4,750[ppm], 2.37[g/h], 102.3[g/kWh]. Also, the result of reaction of 1,8921ppm] ozone and the sampling water from the lake, the water quality was improved from IV grade to In grade, and obtained 100[%] sterilization rate of Escherichia coli within 5.0(min).

  • PDF