• Title/Summary/Keyword: Superimposition

Search Result 168, Processing Time 0.027 seconds

Analysis of the Types of Fractal Dimension Appeared in Fashion (패션에 나타난 프랙탈 디멘션의 유형분석)

  • Song, Arum;Kan, Hosup
    • Journal of Fashion Business
    • /
    • v.22 no.1
    • /
    • pp.135-147
    • /
    • 2018
  • Since the 20th century, there has been a growing interest in the new concept of fractals, a combination of mathematics and art, and the attempt to study the creative spatial aspects of the concept is being made. The purpose of this research is to examine artistic characteristics of fractal dimension and then analyze the types of fractal dimensions expressed in the fashion. Previous literature on fractals and dimension, and visual data on art and fashion collected over the Internet were used for analysis. Fractal dimension refers to the spatial concept of structural dimension of geometrical self-similarity. An analysis of the types of fractals seen in fashion revealed spatial expansion, the repetition in continual figures, superposition accordant to different sizes, and shades of different shapes. The aesthetic characteristics of fractal dimension appearing in fashions were examined based on analyses of fractal dimension types; the inherent characteristics of self-similarity, superimposition, and atypicality were found. Results obtained from this study are expected to be used as basic materials for the application of the design of fractal dimension into various perspectives of fashion.

Experimental study on concrete-encased composite columns with separate steel sections

  • Xiao, Congzhen;Deng, Fei;Chen, Tao;Zhao, Zuozhou
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.483-491
    • /
    • 2017
  • This paper presents an experimental study on the behavior of concrete-encased composite columns with multiseparate steel sections subjected to axial and eccentric loads. Six 1/4-scaled concrete-encased composite columns were tested under static loads. The specimens were identical in geometric dimensions and configurations, and the parameter of this experiment was the eccentricity ratio of the applied load. Each two of the specimens were loaded with 0, 10%, and 15% eccentricity ratios. The capacity, deformation pattern, and failure mode of the specimens were carefully examined. Test results indicate that full composite action between the concrete and the steel sections can be realized even though the steel sections do not connect with one another. The concrete-encased composite columns can develop stable behavior and sufficient deformation capacity by providing enough transverse reinforcing bars. Capacities of the specimens were evaluated based on both the Plain Section Assumption (PSA) method and the superimposition method. Results show that U.S. and Chinese codes can be accurate and safe in terms of bending capacities. Test results also indicate that the ACI 318 and Mirza methods give the best predictions on the flexural stiffness of this kind of composite columns.

Comparative evaluation of the fitness of anterior and posterior interim crowns fabricated by additive manufacturing (적층가공 방식으로 제작한 전치와 구치 임시보철물의 적합도 비교)

  • Park, Young-Dae;Kang, Wol
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.153-159
    • /
    • 2021
  • Purpose: The purpose of this study was to assess the fitness of anterior and posterior interim crowns fabricated by three different additive manufacturing technologies. Methods: The working model was digitized, and single crowns (maxillary right central incisor and maxillary right first molar) were designed using computer-aided design software (DentalCad 2.2; exocad). On each abutment, interim crowns (n=60) were fabricated using three types of additive manufacturing technologies. Then, the abutment appearance and internal scan data of the interim crown was obtained using an intraoral scanner. The fitness of the interim crowns were evaluated by using the superimposition of the three-dimensional scan data (Geomagic Control X; 3D Systems). The one-way analysis of variance and Tukey posterior test were used to compare the results among groups (α=0.05). Results: A significant difference was found in the fitness of the interim crowns according to the type of additive manufacturing technology (p<0.05). The posterior interim crown showed smaller root mean square value than the anterior interim crown. Conclusion: Since the fitness of the posterior interim crown produced by three types of additive manufacturing technology were all within clinically acceptable range (<120 ㎛), it can be sufficiently used for the fabrication of interim crowns.

Diagnosis of Coxofemoral Joint Luxation in a Whooper Swan (Cygnus Cygnus) Using Computed Tomography and Radiography

  • Jinho Jang;Jong-pil Seo;Hyohoon Jeong;Seyoung Lee;YoungMin Yun
    • Journal of Veterinary Clinics
    • /
    • v.41 no.2
    • /
    • pp.139-142
    • /
    • 2024
  • A wild Whooper swan (Cygnus Cygnus) with limping due to an injured left pelvic limb in an accident was rescued on the seashore and transferred to the Jeju Wildlife Rescue Center on November 23rd, 2020. On physical examination, its body condition score was 1 out of 5 due to starvation and dehydration. The left coxofemoral joint was also examined by careful palpating and estimating the damage. Moderated soft tissue swelling and crepitus surrounding the hip joint were confirmed. Radiography and computed tomography (CT) were used together for an accurate diagnosis of the joint. By radiographs readings, it was difficult to accurately confirm the condition of the proximal femur due to superimposition of the synsacrum and internal organs. However, signs such as avulsion fracture of the femoral head and a few fragments around the joint were revealed by CT imaging. Besides, through three-dimensional (3D) image analysis of CT, the dislocated area and condition of the left hip joint could be accurately and easily confirmed. The diagnostic process showing in this paper could be used as a good reference for diagnosing coxofemoral joint luxation in wild swan.

Spatio-temporal Visualization of PM10 Flow Pattern Using Gravity Model (중력모델을 적용한 미세먼지 흐름 패턴 시공간 시각화)

  • Lee, Geon-Woo;Yom, Jae-Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.417-426
    • /
    • 2019
  • Conventional visualization of PM (Particulate Matter)10 flows applies superimposition of concentration distribution maps and wind field maps. This method is efficient for small scale maps where only macro flow trends are of interest. However, in the case of urban areas, local flows are difficult to model at micro level using wind fields, and therefore different methods of flow extraction is deemed necessary. In this study, flow information is extracted and visualized directly from the PM10 density data by using the gravity model. This method has the advantage that additional information such as wind field is not necessary for estimating the intensity and direction of PM10 flow. The extracted spatio-temporal flow patterns of PM10 are analyzed with relation to traffic information.

Design of Priest Naong's Memorial Area (나옹선사 기념관지구 설계)

  • 홍광표;허상현
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.82-91
    • /
    • 2002
  • The site for this plan is located at the foot of Mt. Unseo at Galcheon-ri, Changsu-myon, Youngdeok-gun. On the site stands Jangyutsa Temple, built by priest Naong in 1355 (in the 4th year of King Gongmin during Koryo Kingdom). The purpose of this plan is to widely publicize and commemorate priest Naong by designing a district centering around the temple. The basic directions of design can be summarized as follows 1) A special Buddhists'pilgrimage and sight-seeing district aimed at commemorating priest Naong will be developed to preserve the historic figure of priest Naong. To this end, a facility will be built to collect, preserve and exhibit materials related with the great priest in order to preserve his legacy and enhance the image of the space. 2) Special fractions which are rare in other districts will be introduced to create an image different from the conventional memorial districts or sight-seeing zones. To this end, the district will be divided into the Jangyuksa Temple area proper and a district memorial area, each of which will have its own unique characteristics with different functions. On the other hand, the two different areas will be related with each other and complemented by each other. Such planning techniques as articulation and superimposition will be used for a synergistic effect. 3) The plan will accommodate various programs centering around historical and cultural assets, and at the same time will allow tourists to have various experiences and access to the natural environment as well as to a variety of events. 4) In order to plan such landscapes as shown in the traditional mountain temples, the traditional tectonic forms will be used for the facilities. It is expected that the district surrounding Jangyuksa Temple will become a popular sight-seeing destination, and with new historical and cultural environments will become a valuable resource to widely publicize the culture of Youngdeok-gun.

A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction

  • Anh, Ji-won;Park, Ji-Man;Chun, Youn-Sic;Kim, Miae;Kim, Minji
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.3-12
    • /
    • 2016
  • Objective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero$^{(R)}$(Align Technology Inc., San Jose, CA, USA) and Trios$^{(R)}$(3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero$^{(R)}$ and Trios$^{(R)}$ systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero$^{(R)}$ scanner (mean deviation, $29.84{\pm}12.08{\mu}m$) proved to be less precise than the Trios$^{(R)}$ scanner ($22.17{\pm}4.47{\mu}m$). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.

Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study (리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.

Pyroelectric Peyformance Evaluation of Pure PZT and Alternately Deposited PZT/PT Thin Films (PZT 순수박막과 PZT/PT 교차박막의 적외선 감지 특성 비교)

  • Ko, Jong-Soo;Kwak, Byung-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1001-1007
    • /
    • 2002
  • To improve the performance of the PZT thin flms, each PZT and PT layer was alternately deposited on a Pt/Ti/Si$_3$N$_4$/SiO$_2$/Si substrate by a modified sol-gel solid precursor technique. For comparison, PZT thin films were also prepared with an identical method under the same conditions. XRD measurement revealed that the diffraction pattern of the multilayer film was due to the superimposition of the PZT and PT patterns. At 1㎑, a dielectric constant of 389 and 558, a dielectric loss of 1.2% and 1.1% were obtained for the PZT/PT and PZT thin films, respectively. If we consider the PT dielectric constant to be 260, it is clear that the dielectric constant of alternately deposited PZT/PT thin films was well adjusted. The PZT/PT thin film showed a low dielectric constant and a similar dielectric loss compared with those of the PZT film. The figures of merit on detectivity for the PZT/PT and PZT thin films were 20.3$\times$10$\^$-6/㎩$\^$-$\sfrac{1}{2}$/, and 18.7$\times$10$\^$-6/㎩$\^$-$\sfrac{1}{2}$/, and the figures of merit on voltage response were 0.038㎡/C and 0.028 ㎡/C, respectively. The high figures of merit for the PZT/PT film were ascribed to its relatively low dielectric constant when compared to the PZT thin films.

Diagnostic Imaging of Nasal Adenocarcinoma in Four Dogs (개에서 비강 샘암종의 영상 진단 증례)

  • Jung, Joo-Hyun;Chang, Jin-Hwa;Oh, Sung-Kyoung;Kim, Kyoung-Min;Lee, Sung-Ok;Lee, Jung-Min;Kim, Hak-Sang;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.355-360
    • /
    • 2006
  • Four dogs with similar respiratory signs were referred to Veterinary Medical Teaching Hospital, Seoul National University. The clinical signs observed in these cases were anorexia, nasal discharge, sneezing, epistaxis, ocular discharge, and exophthalmoses. The routine laboratory tests revealed leukocytosis in two cases. On the skull radiographs, soft tissue density filled nasal cavity with loss of turbinate detail and increased density in frontal sinuses were found in all cases. Lysis of nasal bone was seen in two cases. Lysis of zygomatic arch was seen in one case. On computed tomography scan images, asymmetrical destruction of turbinate and nasal septum, and the superimposition of a soft tissue mass over the turbinate with peripheral contrast enhanced effect were identified in all cases. Destruction of ipsilateral orbital bone and invasion to retrobulbar region were visualized in all cases. In addition, all cases had lysis of cribriform plate. Lysis of nasal bone and destruction of hard palate were seen in two cases. Swelling of submandibular lymph node and salivary gland was seen in a case. Invasion to brain was identified in a case. All cases were diagnosed as nasal adenocarcinoma by cytology with fine needle aspiration and curettage.